Loading…
Loading…
Tender Value
₹9.6 Cr
EMD Value
₹6.3 L
Closing Date
20 Apr 2026, 2:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECTRICAL
16 conditions · 3 needing a document upload
Financial Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. For JV (if applicable): The JV shall satisfy the requirement of Financial Eligibility mentioned at para above. The financial capacity of the lead member of JV shall not be less than 51% of the financial eligibility criteria mentioned at para above. The arithmetic sum of individual "financial capacity" of all the members shall be taken as JV's financial capacity to satisfy this requirement. Note: Contractual payment received by a Member in an earlier JV shall be reckoned only to the extent of the concerned member's share in that JV for the purpose of satisfying compliance of the above mentioned financial eligibility criteria in the tender under consideration.
No Technical and Financial credentials are required for tenders having advertised value up to Rs 50 lakh.
Technical Eligibility Criteria: (1)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works, each costing not less than the amount equal to 30% of advertised value of the tender, Or Two similar works, each costing not less than the amount equal to 40% of advertised value of the tender, Or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. For JV firms (if applicable): The technical eligibility for the work as per para 1 above, shall be satisfied by either the 'JV in its own name & style' or 'Lead member of the JV'. Each other (non-lead) member(s) of JV, who is/ are not satisfying the technical eligibility for the work as per para 1 above, shall have technical capacity of minimum 10% of the cost of work i.e., each non-lead member of JV member must have satisfactorily completed or substantially completed during the last 07 (seven) years, ending last day of month previous to the one in which tender is invited, one similar single work for a minimum of 10% of advertised value of the tender.
No Technical and Financial credentials are required for tenders having advertised value up to Rs 50 lakh.
Definition of Similar Work :- Supply, installation, testing and commissioning of overhead transmission line work of 11kV & above.
42 conditions · 9 needing a document upload
Whether cost of earnest money deposited.
Whether cost of tender document deposited.
Whether valid electrical contractor license and valid supervisor license submitted.
Whether document related to technical eligibility submitted.
Whether document related to financial eligibility submitted.
Whether photocopy of Pan Card submitted.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Payment of Earnest money deposit (EMD) & Tender Document cost (TDC) in respect of e-tendering should be accepted through net banking or payment gateway only.
Due to implementation of GST by government of India with effect from 01-07-2017, All the Bidder / Tenderers are advice to ensure that they are GST compliant and their quoted tax structures/rates are as per GST law. The quoted rate should include all applicable taxes as per GST law and no claims will be entertained after the closing date of the tender.
In case the successful tenderer is not liable to be registered under CGST / IGST / UTGST / SGST act. The Railway shall deduct the applicable GST from his / Their Bills under Reverse Charge Mechanism (RCM) and deposit the same to the concerned tax authority.
Those tenderer/bidder who wish to get payment through LC are requested to follow the related rules mentioned in tender contract documents. For getting payment through letter of Credit (LC) and uploading duly filled up as per Annexure - O & Annexure P, attached with the tender documents.
Address of Firm: The tenderer should upload scanned copy in PDF format of the complete address of the Firm to which all correspondences shall be made by Railways.
Tender Form: The tenderer should upload scanned copy in PDF format of duly filled up "Tender Form" available at Appendix-IV of the attached tender document.
GSTIN: The tenderer should upload scanned copy in pdf format of the GSTIN in favor of the company.
Modification of 33 KV, 11 KV & LT overhead lines infringing with construction of new Railway line from Kokrajhar Railway Station to Gelephu Railway Station
ELC-RE-MLG-06-25-26
ELC-RE-MLG-06-25-26
Open
Works - General
18 Months
Kamrup, Assam
₹0
₹6.3 L
20 Apr 2026
18 Mar 2026
6 Apr 2026
132 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 9,61,90,245 | ||
| — | 80.00 | — | — | ||
| To conduct survey of the locations of infringement and submit drawings showing plan, elevation, CSD & BOQ prepared in AutoCad or similar platforms. Approval to be obtained from concerned SEB officials after approval of Railways. All coordination with SEB for approval of drawings shall be done by the contractor. Two set drawings of every location shall be submitted to Railways after final approval. | — | — | — | 80,000 | |
| — | 230.00 | — | — | ||
| Supply of galvanized tubular pole 12 mtr long type 410SP-66 with step length 5.80- 3.10-3.10 mtr sectional dia 219.1x193.7x165.1 mm sectional thickness 5.9x4.85x4.5mm as per IS 2713-1980 including suitable size base plate and cap on top. | — | — | — | 66,26,300 | |
| — | 170.00 | — | — | ||
| Supply of galvanized tubular pole 9 mtr long type 410SP-33 with step length 5.00- 2.00-2.00 mtr sectional dia 165.1x139.7x114.3 mtr sectional thickness 5.4x4.5x3.65 mm as per IS 2713-1980 including suitable size base plate and cap on top. | — | — | — | 23,52,460 | |
| — | 400.00 | — | — | ||
| Erection of tubular pole 9-12 Mtr.long including digging the pit 1/5th. of total length. | — | — | — | 2,44,000 | |
| — | 120.00 | — | — | ||
| Supply and execution of CC foundation work in ratio 1:3:6 by cement, sand and chips of size 19mm & down. The size of the CC block will be 30cm dia with height upto the pole depth below GL and 30Cm above GL including tie muffing of DP. | — | — | — | 2,47,200 | |
| — | Breakup for | details. | — | ||
| Supply & fixing of GI channel size 100x50x50x6mm bracket of following length clamped with above pole made by GI flat 50x5mm with 50x16mm GI bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting. As required as per direction of Engineer in charge. | — | — | — | 44,512 | |
| — | Breakup for | details. | — | ||
| Supply & fixing of GI channel size 75x40x40x6mm bracket of following size clamped with pole made by MS flat of size 50x5mm with 50x16mm bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting . | — | — | — | 5,84,832 | |
| — | Breakup for | details. | — | ||
| Supply & fixing of GI angle size 65x65x6mm bracket of following sizes clamped with above pole made by GI flat 50x5mm with 50x16mm GI bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting. As required as per direction of Engineer in charge. | — | — | — | 6,78,408 | |
| — | Breakup for | details. | — | ||
| Supply & fixing of GI angle size 50x50x6mm bracket of following size clamped with above pole made by MS flat 50x5mm with 50x16mm bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting . | — | — | — | 4,42,244 | |
| — | 4.00 | — | — | ||
| Suply and erection of 3 Nos. Zinc Oxide Station Class-I lightning arrestor suitable for 3 wire 33KV with rated voltage 30KV(RMS) and a normal discharge current rating of 10KA as per IS:4004 (1985), complete with galvanised clamping arrangement, GI bolts, nuts, washer etc. (3 Nos in a set). | — | — | — | 1,01,960 | |
| — | 44.00 | — | — | ||
| Supply and erection of 3 Nos station class - 1 Zinc oxide Lightening arrestor suitable for 3 wire 11 KV OH with rated voltage 9 KV (RMS) with normal discharge current rating of 10 KA and complete with galvanized clamping arrangement, GI bolts, nuts, washer as required conforming to IS 3070-III-1993. | — | — | — | 8,45,064 | |
| — | 12.00 | — | — | ||
| Supply and erection of 3 Nos. Zinc Oxide distribution class lightning arrestor with rated voltage 9KV (RMS) and a normal discharge current rating of 5KA as per IS:3070-III (1993) suitable for 3 wire 11KV, complete with galvanised clamping arrangement, GI bolts, nuts, washer etc. (3 Nos in a set). As required as per direction of Engineer in charge. | — | — | — | 23,568 | |
| — | 30.00 | — | — | ||
| Supply & erection of 2P composite polymer 33 KV ball & socket type Disc insulator ( 90 KN) with minimum creepage distance 900mm & sectional length 510mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rodand sealed to the hot dipped galvanised carbon steelend fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or asper IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting | — | — | — | 81,240 | |
| — | 24.00 | — | — | ||
| Supply & erection of 2P composite polymer 33 KV Pin insulator (10 KN) with minimum creepage distance 980mm & sectional length 415 mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731(1971) & 2488 (Pt-II) 1974 complete with hardware fitting | — | — | — | 39,648 | |
| — | 660.00 | — | — | ||
| Supply & erection of 2P composite polymer 11 KV ball & socket type Disc insulator ( 70 KN) with minimum creepage distance 320 mm & sectional length 300 mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rodand sealed to the hot dipped galvanised carbon steelend fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or asper IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting | — | — | — | 4,81,800 | |
| — | 396.00 | — | — | ||
| Supply & erection of 2P composite polymer 11 KV Pin insulator (10 KN) with minimum creepage distance 340mm & sectional length 235 mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731(1971) & 2488 (Pt-II) 1974 complete with hardware fitting | — | — | — | 2,01,564 | |
| — | 272.00 | — | — | ||
| Supply& erection of LT shackle insulator of size 75x90 mm along with "D" clamp and full threaded 8"long 1/2" dia MS bolt and nut with all accessories for tensioning. | — | — | — | 8,976 | |
| — | 60.00 | — | — | ||
| Supply and fixing of pin insulator of size 80x105 mm complete with 50X5mm MS 'D' clamp, Nuts & Bolts. | — | — | — | 1,380 | |
| — | 1.00 | — | — | ||
| Supply & erection of 33 KV Gang Operated Air breakoff load disconnecting switch - 400Amp 3 Pole Rcking type each pole consist of galvanised steel base, HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arching horns | — | — | — | 19,337 | |
| — | 1.00 | — | — | ||
| Supply and erection of 33KV DO fuse double stack channel type 200 Amps. capacity | — | — | — | 13,731 | |
| — | 8.00 | — | — | ||
| Supply & erection of 11 KV Gang Operated Air breakoff load disconnecting switch - 400 Amp 3 pole rocking type each pole consist of galvanised steel base, HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arching horns of adequate sections to break magnetising current of the transformer horizontal Gi pipe of adequate length for phase separation and 25mm dia, 3.65mm thickness GI pipeof adequate length for operation from ground level and operating handle complete in both ON & OFF positions. | — | — | — | 83,240 | |
| — | 6.00 | — | — | ||
| Supply and erection of 11KV DO fuse double stack channel type 200 Amps capacity. | — | — | — | 39,360 | |
| — | 600.00 | — | — | ||
| Supply, stringing & binding of ACSR conductor Raccoon of size 6/1/ 4.09 mm conforming to IS : 398-Pt.II-1976 | — | — | — | 42,000 | |
| — | 10560.00 | — | — | ||
| Supply, stringing & binding of ACSR conductor Rabbit of size 6/1/ 3.35 mm conforming to IS : 398-Pt.II-1976 | — | — | — | 4,11,840 | |
| — | 8976.00 | — | — | ||
| Supply, stringing & binding of ACSR conductor,Weasal of size 6/1/ 2.59 mm conforming to IS : 398-Pt.II-1976 | — | — | — | 1,34,640 | |
| — | 11928.00 | — | — | ||
| Supply & stringing, binding of GI wire 8 SWG for guarding | — | — | — | 47,712 | |
| — | 2982.00 | — | — | ||
| Supply & stringing, binding of GI wire 10 SWG for guarding | — | — | — | 8,946 | |
| — | 228.00 | — | — | ||
| Supply & erection of Galvanised stay set for HT OH line comprising of 20 mm dia with 1.8 mtr long stay rod, anchor plate of size 30x30cmx6mm/45x45x7.5mm, turn buckle (20mmx600 mm), 20mm thimble , stay clamp, 7/10mm dia GI stay wire, Guy strain insulator of size 85 x140 mm as per ref. IS 5300/1969, and cc foundation with ratio 1:3:6 including excavation, refilling etc. | — | — | — | 2,30,508 | |
| — | 170.00 | — | — | ||
| Supply & erection of Galvanised stay set for LT OH line comprising of 20 mm dia. 1.8 mtr long stay rod, anchor plate of size 23x23cmx 6mm dia thick, thimble,stay clamp, 7/12SWG GI stay wire strain insulator etc.in cc foundation with ratio 1:3:6 including excavation, refilling etc | — | — | — | 1,24,440 | |
| — | 400.00 | — | — | ||
| Supply & erection of danger board size 8"x6" on MS clamp made of 20x3mm for 33/11 KV showing the voltage grade, skull symbol etc. | — | — | — | 12,800 | |
| — | 400.00 | — | — | ||
| Supply & erection of barbed wire upto height 2.5m to be fixed on pole with 2 nos. of clamps of suitable size and as per direction of Engineer In charge at site. | — | — | — | 66,000 | |
| — | Breakup for | details. | — | ||
| Supply & fixing of 6 mtr long ISI marked following High Density Polythylene pipe of Working pressure 6Kgf./Cm2 (IS:4984/1995) clamped with the bracket by 50mm wide M.S. flat clamp & G.I. nut bolt of size 50x12mm with washer as per direction of engineer in charge at site. Each cables outside the pipe length are also to be clamped with the brackets by MS flat and G.I. nut/bolt/washer. | — | — | — | 9,69,744 | |
| — | 10.00 | — | — | ||
| Supply & erection of 33 KV heat shrinkable outdoor type cable termination kit including all accessories for Single core 400 Sqmm screened XLPE Cable | — | — | — | 44,280 | |
| — | 10.00 | — | — | ||
| Supply & erection of 33 KV heat shrinkable outdoor type cable termination kit including all accessories for Single core 630 Sqmm screened XLPE Cable. | — | — | — | 51,150 | |
| — | 440.00 | — | — | ||
| Supply & erection of 11 KV heat shrinkable outdoor type cable termination kit including all accessories for Single core 240-300 Sqmm screened XLPE Cable. | — | — | — | 9,00,240 | |
| — | 96.00 | — | — | ||
| Supply & erection of LT 1.1 KV heat shrinkable outdoor type XLPE/PVC/PILC cables termination kit including all accessories :- 4 core70/95/120/150 mm2 | — | — | — | 1,16,544 | |
| — | 24.00 | — | — | ||
| Supply & erection of LT heat shrinkable outdoor type cable termination kit including all accessories for 4 core 150/185mm2 LT cables. As per direction of EIC at site. | — | — | — | 43,344 | |
| — | 16.00 | — | — | ||
| Supply & erection of LT heat shrinkable outdoor type cable termination kit including all accessories for 4 core 240/300mm2 LT cables. As per direction of EIC at site | — | — | — | 29,264 | |
| — | 2000.00 | — | — | ||
| Construction of cable trench of desired depth below the ground level for laying cable/pipes as per direct laying method and direction of site Engineer and filling & compacting of trench with soil with watering and ramming after laying of cable and disposal of garbage form site within a distance of 50 mtr. | — | — | — | 8,34,000 | |
| — | 96.00 | — | — | ||
| Supply and laying of standard Bricks as per procedure for cable protection | — | — | — | 2,30,688 | |
| — | 520.00 | — | — | ||
| Horizontal boring of size 100/150/200/250/300 mm dia hole across railway embankment / Road at a depth of 1.5Mtr below GL by HDD Machine at Contractor's own arrangement as per direction of Engineer in charge at site. | — | — | — | 29,62,440 | |
| — | 66.00 | — | — | ||
| Supply & laying of class LA type CI pipe 300 mm dia of measureable length 5.5 mtr each length for passing of cable conforming to ISS : 1536-1989, 1.6m below ground level as per direction of Engineer In charge at site. | — | — | — | 2,84,724 | |
| — | 22.00 | — | — | ||
| Supply & laying of class LA type CI pipe 250 mm dia of measureable length 5.5 mtr each length for passing of cable conforming to ISS : 1536-1989, 1.6m below ground level as per direction of Engineer In charge at site | — | — | — | 83,974 | |
| — | 1760.00 | — | — | ||
| Supply & laying of class LA type CI pipe 200 mm dia of measureable length 5.5 mtr each length for passing of cable conforming to ISS : 1536-1989, 1.6m below ground level as per direction of Engineer In charge at site | — | — | — | 43,89,440 | |
| — | 396.00 | — | — | ||
| Supply & laying of class LA type CI pipe 150 mm dia of measureable length 5.5 mtr each length for passing of cable conforming to ISS : 1536-1989, 1.6m below ground level as per direction of Engineer In charge at site | — | — | — | 5,25,096 | |
| — | 935.00 | — | — | ||
| Supply & laying of class LA type CI pipe 80 mm dia of measureable length 5.5 mtr each length for passing of cable conforming to ISS : 1536-1989, 1.6m below ground level as per direction of Engineer In charge at site | — | — | — | 7,78,855 | |
| — | 120.00 | — | — | ||
| Supply and laying of HDPE pipe of size 8 inch (200mm outside dia), 6kgf/cm2, 6.0 mtr each length, PE-100 Grade conforming to IS : 4984/1995 | — | — | — | 87,600 | |
| — | 180.00 | — | — | ||
| Supply and laying of HDPE pipe of size 6 inch (160mm outside dia), 6kgf/cm2, 6.0 mtr each length, PE-100 Grade conforming to IS : 4984/1995 | — | — | — | 70,920 | |
| — | 240.00 | — | — | ||
| Supply and laying of HDPE pipe of size 4 inch (110mm outside dia), 6kgf/cm2, 6.0 mtr each length, PE-100 Grade conforming to IS : 4984/1995 | — | — | — | 64,320 | |
| — | 800.00 | — | — | ||
| Supply & fixing of cable marker (metalic) showing the details of cable size, voltage grade and number of cables on ground by CC foundation. | — | — | — | 1,32,000 | |
| — | 16.00 | — | — | ||
| Supply and erection of earthing by 50 mm GI pipe, 3mtr long 4.05mm thickness including construction of earth pit, RCC earth cover slab with filling/mixing of salt, charcoal etc of required quantity and earth continuty by 25x3mm GI strip with GI nuts bolts washer etc.including welding, earth resistance flag etc. as per Drg.No. NFR/CEE/CON/GS/10(earthingsystem)/04/2016 & as perTechnical Specification No.NFR/ELECT/GS/10(EARTHINGSYSTEM). | — | — | — | 27,728 | |
| — | 488.00 | — | — | ||
| Supply and erection of earthing by 50 mm GI pipe IS:1239/1990 (Pt-I) of 3.60mm thickness 3mtr long including construction of earth pit, RCC earth cover slab with filling/mixing of salt, charcoal etc of required quantity and earth continuty by 25x3mm GI strip with GI nuts bolts washer etc. including welding, earth resistance flag etc. | — | — | — | 8,38,384 | |
| — | 4.00 | — | — | ||
| Supply & erection of maintenance free earthing NFR/CEE/CON/GS/10(Earthingsystem)/06/2016, & as per Technical NFR/ELECT/GS/10(EARTHINGSYSTEM). | — | — | — | 27,576 | |
| — | — | — | as per DRG/No:- Specification No. | ||
| — | 5040.00 | — | — | ||
| Supply and laying of GI Strip including suitable size hole, GI nuts & bolts, washer or welded in joints wherever required as per direction of Engineer in charge at site of size 25 mm x 6 mm | — | — | — | 2,52,000 | |
| — | 120.00 | — | — | ||
| Supply & laying of earth continuity by 6 SWG GI wire for earth continuity | — | — | — | 9,120 | |
| — | 320.00 Each | Span | — | ||
| Dismantling of over head alignment like conductor, insulator, bracket etc. The released materials to be deposited to SEB's office/store/designated place by Contractor's own arrangement. | — | — | — | 53,440 | |
| — | 480.00 | — | — | ||
| Uprooting of existing pole without damaging the bottom of the pole. The released materials to be deposited to SEB's office/store/designated place by Contractor's own arrangement. | — | — | — | 1,32,000 | |
| — | Breakup for | details. | — | ||
| Supply of XLPE insulated, 1.1 KV grade, PVC inner & outer sheathed, stranded aluminium conductor, armoured cable conforming to IS 7098 part II along with provision of socket, lugs, nut, bolt, washer, cable tag and other accessories required for commissioning as per requirement at site of the following sizes: | — | — | — | 1,55,20,360 | |
| — | Breakup for | details. | — | ||
| Supply of Aluminium HT Cables, Stranded Compacted Circular Aluminium Conductor, Conductor Screen with Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with Extruded Semi Conducting Compound in Combination with Copper Tape, AL Flat Strip Armoured, & Overall PVC Sheathed Cable Conforming to IS 7098 (Part- 2) 2011 with upto Date Amendments along with provision of socket, lugs, nut, bolt, washer, cable tag and other accessories required for commissioning as per requirement at site of the following sizes: | — | — | — | 5,07,19,464 | |
| — | 800.00 | — | — | ||
| Laying of 33 KV grade single core 400/630mm2 XLPE insulated armoured aluminium cable partly through protection pipe partly underground 1.5 mtr below GL as per direction of Engineer In charge at site | — | — | — | 73,600 | |
| — | 4800.00 | — | — | ||
| Laying of 11KV grade single core 240mm2 XLPE insulated armoured aluminium cable partly through protection pipe partly underground 1.5 mtr below GL as per direction of Engineer In charge at site | — | — | — | 3,40,800 | |
| — | 12800.00 | — | — | ||
| Laying of 11KV grade single core 300mm2 XLPE insulated armoured aluminium cable partly through protection pipe partly underground 1.5 mtr below GL as per direction of Engineer In charge at site | — | — | — | 10,62,400 | |
| — | 1120.00 | — | — | ||
| Laying of 1.1KV grade 4 core 185/240mm2 XLPE insulated armoured aluminium cable partly through protection pipe partly underground 1.5 mtr below GL as per direction of Engineer In charge at site | — | — | — | 62,720 | |
| — | 2560.00 | — | — | ||
| Laying of 1.1KV grade 4 core 120mm2 XLPE insulated armoured aluminium cable partly through protection pipe partly underground 1.5 mtr below GL as per direction of Engineer In charge at site | — | — | — | 1,12,640 | |
| — | 1280.00 | — | — | ||
| Laying of 1.1 KV grade LT 4 core 70 mm2 XLPE insulated Aluminium armoured cable partly through protection pipe and partly underground 1.5 mtr below GL as per direction of Engineer in charge at site. | — | — | — | 39,680 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC 2022
ATTACHMENT
ACS-1_1.pdf
ATTACHMENT
ACS-2.pdf
ATTACHMENT
ACS-3.pdf
ATTACHMENT
ACS-4.pdf
ATTACHMENT
ACS-5.pdf
ATTACHMENT
ACS-6.pdf
ATTACHMENT
ACS-7.pdf
ATTACHMENT
ACS-8.pdf
ATTACHMENT
ACS-9.pdf
ATTACHMENT
ACS-10.pdf
ATTACHMENT
AdditionalTermsandConditions.pdf Terms and Conditions
ATTACHMENT
GCC_IndianRailways-April-2022.pdf
ATTACHMENT
AdditionalTermsandConditions.pdf
ATTACHMENT
corrigendum.pdf
CORRIGENDUM
Tenderdocument.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .