Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹32.2 L+₹6.3 L (24.1%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹37.3 L+₹11.3 L (43.7%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
22 Apr 2021, 6:00 pmClosed
Chief Engineer Lucknow Zone
HQ CE Lucknow Zone, 17, cariappa marg, Lucknow 226002
REPAIR /MAINT OF EXTERNAL ELECTRIFICATION AT CANTT UNDER GE (I) KANPUR
2021_MES_431095_2
CELZ/KAN/T-25 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Kanpur
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) Kanpur
₹96,000
Yes
28 May 2021
1 Apr 2021
24 Apr 2021
1 Apr 2021
22 Apr 2021
8 Apr 2021
Amount
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, foundation filling of poles or stays and for rerouting of cables complete all as specified and directed.
Description all as per item No 01 here-in-before but depth exc 1.5 mtr and not exc 3 mtr complete all as specified and directed.
Returning, filling in, well ramming including spreading, watering, leveling n.exc 25 cm layers using soil obtained from excavation complete all as specified and directed.
Removing excavated material (soil) to a distance n.exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as specified and directed.
M&L for sand cushioning to U/G cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, in trenches complete all as specified and directed. Note: - Only punned thickness shall be measured.
Brick covering width equal to length of cable for mechanical protection to cable with well burnt sub class 'B' bricks laid dry flat complete all as specified and directed.
Laying only bricks any size/type obtained from srl item No 1 above, over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed.
M & L for un-reinforced precast concrete cable cover class HV type 1, flat, size 300mmx180mmx40mm in trenches for protection of cable complete all as specified and directed. Note: Purchase voucher and manufacturer test certificate shall be submitted by contractor while claiming payment.
M&L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate for foundation filling of poles as mass concrete complete all as specified and directed .
M & L for Plain cement concrete (1:3:6) type C-2, using 40mm graded crushed stone aggregate in foundation filling of stays complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground, floors or pavings not exceeding 15 cm thick below or above ground level complete all as specified and directed.
M & L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor / hard-standing, surface finished even and smooth without using extra cement to match with the existing surface complete all as specified and directed.
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection of cable & pipe upto 80 mm bore complete all as specified and directed. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
Taking out carefully unserviceable LT UG cable of size 6 Sqmm to 35 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as specified and directed. Note: Earth work, sand, bricks will be measured and paid separately.
Taking out carefully unserviceable LT UG cable of size 50 Sqmm to 240 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as specified and directed. Note: Earth work, sand, bricks will be measured and paid separately.
Taking out carefully unserviceable HT UG cable of size 70 Sqmm to 185 Sqmm from trenches and relaying same after repairs in same or other indicated location and testing complete all as specified and directed. Note: Earth work, sand, bricks will be measured and paid separately.
Disconnecting electrically and taking out old unserviceable LT UG cables any type of size 6 Sqmm to 25 Sqmm 2 core complete all as specified and directed.
Supply and laying to wall or poles or fixing or passing through pipe, in replacement of 1100 volts grade heavy duty cable with XLPE insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sq. mm nominal cross section 2 core in service connections complete all as specified and directed. Note : The rate quoted shall be deemed to including making good all distributed wall surfaces/ flooring /tilling to match with existing specification.
Description all as per item No 18 here-in-before but of size 10 sq mm 2 core complete all as specified and directed.
Description all as per item No 18 here-in-before of size 6 sq mm 2 core complete all as specified and directed.
Description all as per item No 18 here-in-before but of size 25 sq mm 2 core complete all as specified and directed.
Disconnecting electrically and taking out old unserviceable LT UG cables any type of size 25 Sqmm to 95 Sqmm 3.5 core complete all as specified and directed..
Disconnecting electrically and taking out old unserviceable LT UG cables any type of size 120 Sqmm to 240 Sqmm core complete all as specified and directed.
Supply and laying in trenches or fixing to wall/pole or passing through pipe in replacement of XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 25 Sqmm 3.5 core complete all as specified and directed. Note : The rate quoted shall be deemed to including making good all distributed wall surfaces/ flooring/ tilling to match with existing specification.
Description all as per item No 24 here-in-before but of size 35 sq mm 3.5 core complete all as specified and directed
Description all as per item No 24 here-in-before but of size 70 sq mm 3.5 core complete all as specified and directed
Description all as per item No 24 here-in-before but of size 95 sq mm 3.5 core complete all as specified and directed
Description all as per item No 24 here-in-before but of size 120 sq mm 3.5 core complete all as specified and directed
Description all as per item No 24 here-in-before but of size 150 sq mm 3.5 core complete all as specified and directed
Description all as per item No 24 here-in-before but of size 185 sq mm 3.5 core complete all as specified and directed
Description all as per item No 24 here-in-before but of size 240 sq mm 3.5 core complete all as specified and directed
S&F in replacement of Cable jointing kit for 1100 volt grade cable for outdoor/indoor termination end joint heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 16 to 35 Sqmm 3.5/4 core. complete all as specified and directed
Description all as per item No 32 here-in-before but of size 6 to 25 sq mm 2 core complete all as specified and directed
Description all as per item No 32 here-in-before but of size 50 to 95 sq mm 3.5 core complete all as specified and directed
Description all as per item No 32 here-in-before but of size 120 to 185 sq mm 3.5 core complete all as specified and directed
Description all as per item No 32 here-in-before but of size 225 to 300 sq mm 3.5 core complete all as specified and directed
S&F in replacement of cable jointing kit for 1100 volt grade cable for straight through termination heat shrinkable type complete with jointing material and accessories suitable for XLPE/PVC armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5/4 core. complete all as specified and directed
Description all as per item No 37 here-in-before but of size 25 to 50 sq mm 3.5 core complete all as specified and directed
Description all as per item No 37 here-in-before but of size 70 to 150 sq mm 3.5 core complete all as specified and directed
Description all as per item No 37 here-in-before but of size 185 to 240 sq mm 3.5 core complete all as specified and directed
Disconnecting electrically and taking out old unserviceable HT UG cables any type of size 70 to 185 Sqmm 3 core complete all as specified and directed .
Supply, laying in trenches or passing through pipe/ducts, fixed to wall or poles XLPE insulated screened XLPE sheathed galvanized steel strip or wire armoured electric power cable with alumn conductor of cross sectional area 95 Sqmm 3 core 11 KV rated suitable for earthed system including testing and commissioning all as specified and directed. Note : Excavation and earth work, sand cushioning brick covers and GI pipe etc shall be measured and paid separately.
Description all as per item No 42 here-in-before but of size 120 sq mm 3 core complete all as specified and directed.
Description all as per item No 42 here-in-before but of size 185 sq mm 3 core complete all as specified and directed.
Supply and fixing in replacement of cable straight through jointing kit for 11 KV grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed.
Supply and fixing in replacement of cable straight through jointing kit for 11 KV grade cable termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed.
Supply and fixing cable end jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm omplete all as specified and directed.
Supply and fixing cable end jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed.
Supply and fixing cable end jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed.
Supply and fixing cable end jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed
Dismantling from insulators and taking down ACSR conductor of any size from HT/LT over head lines and depositing to MES store yard complete all as specified and directed.
Dismantling earth wire/cradles wire any size from eye hooks/insulators etc from HT/LT over head lines and depositing to MES store yard complete all as specified and directed.
Dismantling insulator any type and any size from LT over head lines and fixing other side or depositing to MES store yard complete all as specified and directed.
Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside all as required at sitecomplete all as specified and directed.
Dismantling stay assy complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate and depositing iron item to MES store yard and removing of PCC from site complete all as specified and directed.
Dismantling PCC/steel poles any type and any size including excavation for taking out pole, breaking of PCC block with due care and setting aside for reuse or depositing to MES stores yard complete all as specified and directed.
Unbinding from insulators ACSR conductor any size of LT/HT over head line for repairs. Re-stretching of ACSR conductor to achieve proper sag and rebinding to the insulators using alumn/GI binding wire and making all existing cable connections complete all as specified and directed.
S&F Aluminium conductor of any size with steel reinforced complete all as specified and directed.
Supply and fixing galvanized steel wire any size to LT over head line as continuous earth or fabrication of guarding cradles complete all as specified and directed.
S & F cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed.
Supply, erecting and installation of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) duly painted with two coat of black bituminous paint through out, internally and externally up to planning depth and painting remaining portion of pole with two coat of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making/painting three Nos circular strips each of 30 cm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking pole number with black paint complete all as specified and directed. Note : Excavation, earth work, PCC work shall be measured and paid separately under respective items.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Description all as per srl item No 62 but fixing only retrieved from srl item no. 54 here in before after painting with one coat of aluminium paint complete all as specified and directed.
Disconnecting electrically, dismantling from foundation with due care and setting aside LT/HT feeder pillar box any type any size with all accessories complete all as specified and directed..
Supply and installation, connecting eclectically & commissioning in replacement of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door open able with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 200 amps rated copper bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 Volt, 35 KA complete all as specified and directed.
M&L for stay assy complete with MS stay plate of size 300x300x6mm thick, stay rod 16mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I of 1991 complete all as specified and directed. Note : Excavation, PCC, and loop type insulators will be measured separately.
M&L for loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and directed.
Fixing only insulator any type and any size from HT/LT over head lines received from item No 53 here in after complete all as specified and directed.
S&F in replacement of Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed.
S&F in replacement of GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed. Note :Clamps for fixing pipe, nuts, bolts washers shall be measured separately.
Description all as per item No 70 here-in-before but of size 50 mm bore complete all as specified and directed.
Description all as per item No 70 here-in-before but of size 40 mm bore complete all as specified and directed.
S&F in replacement of bus bar chambers 300 mm long iron clad with 4 Nos 200 Amp rated copper strips complete fixed flush wall and making good the disturbed wall surfaces all as a required at site or directed complete all as specified and directed.
Description all as per item No 73 here-in-before but 2 Nos 100 Amp complete all as specified and directed.
S & F in replacement of in position retro reflective sign board cut to sizes/shape made out of 3 mm thick high density aluminium sheet fixed on wall with aluminium frame work with all weather effected duly riveted with vinyl sheet based of blue colour base by hot process including letter/number as directed fitted on wall with proper arrangement complete all as specified and directed.
S&F in replacement of line diagram of electric/water supply or chart any type fabricated of 3mm thick acrylic sheet fibre board any weather effeced of size 1.5 mtr x 1.5 mtr incl writing figure (letter/number/shapes) all as directed and providing with 6mm thick plywood support by aluminium beading complete and fixing on wall of any type with rawal plug and screws etc complete all as specified and directed.
Repair, maint and of broken doors for LT panel and bus bars by welding and incl fixing of new hinges and other material as required at site complete all as specified and directed.
S&F in replacement of notice board made out of plywood board with fixing of cloth of best quality green colour supported by aluminium beading complete of size 1.5 mtr x 1.5 mtr fixing on wall with necessary arrangement complete all as specified and directed.
Removal of unwanted vegetation/bushes/small plants shrubs around the water/electric supply installations/ inside the valve pit and surface excavation not exceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M complete all as specified and directed.
M & L for cutting, trimming of branches along the OH conductor of LT/ HT line within 2 mtr distance along both side of line and strictly all branches in one place complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 400 Amps 35/36 KA, thermal magnetic release S1 -01 No (incoming) complete all as specified and directed.
Description all as per item No 81 here-in-before but MCCB 250 Amps 35/36 KA complete all as specified and directed.
Description all as per item No 81 here-in-before but MCCB 100 Amps 25 KA complete all as specified and directed.
Description all as per item No 81 here-in-before but MCCB 160 Amps 36 KA complete all as specified and directed.
Description all as per item No 81 here-in-before but MCCB 63 Amps 25 KA complete all as specified and directed.
Detection of any type of fault in HT under ground Line (laid in soil at plane area or forest area) with the help of Cable fault locator machine. Cable fault locator with carrying vehicle will be brought by the cable fault detection agencies. Span of faulty cable will be trace out by the agencies by meggering HT cable. Note : 1. Detection of fault in one span of length will be measured as one Job either machine placed from one side or both side of the cable. 2. Technicians will be employed by the working agencies. 3. Earth work and taking out will be measured and paid seperately. 4. Material for repair and replacement measured and paid saperately. 5. One job shall be measured if the fault has successfully identified by the fault locator machine or removing moisture in the cable if required complete all as specified and directed. .
Taking down carefully transformer any capacity, any make, any type from pole / plinth by dismantling, disconnecting HT & LT sides, earthings of transformer, supporting angles / cross arms, shifting / transporting transformer carefully from the site and shifting/refixing at other location under GE (I) Kanpur after cleaning and making all electrical/earthing connections complete all as specified and directed.
Disconnecting electrically, dismantling from foundation with due care and setting aside old unserviceable LT panel box any type any size with all accessories complete all as specified and directed.
M & L for replacement of existing unserviceable LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron frame fixed on RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 250 Amps 4 pole 35/36 ka, four Nos 100 Amps 4 pole 25 ka, two Nos 63 Amps 25 ka as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site complete all as specified and directed. Note:- Drawing of LT panel/busbar shall be submitted by firm for approval.
Description all as per item No 89 here-in-before but for copper bus bar 600 Amps 3 phase 4 wire and for one incoming MCCB 400 Amps 4 pole 35/36 ka, outgoing two No 250 Amps 4 pole 35/36 ka, two Nos 100 Amps 4 pole 25 ka, two Nos 63 Amps 25 ka and MCB DP 63 Amps- 06 Nos. complete all as specified and directed. Note:- Drawing of LT panel/busbar shall be submitted by firm for approval.
S&F HT 11 KV bus bar outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made, using angle iron 40mm x 40mm x 6mm and 500mm high, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, insulator & bus bar color code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work complete all as specified and directed. Note:- Drawing of LT panel/busbar shall be submitted by firm for approval.
M&L in replacement of Earthing complete with galvanized earth plate electrode 600 x 600 x6.3 mm thick buried directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel wire 4mm dia as earth lead Earth plate to pole test point including 25mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 50mm thick cover in 1:2:4 Type B-1 reinforced with 8mm dia TMT bars @ 8mm c/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specified and directed.
M & L in replacement of Earthing complete with galvanized earth plate electrode 600 x 600 x6.30 mm thick buried directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel Strip of size 32 x6 mm as earth lead Earth plate to bldg test point including 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 50mm thick cover in 1:2:4 Type B-1 reinforced with 8mm dia TMT bars @ 8mm c/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specified and directd.
M & L in replacement of earthing strip 32 x 6 mm aluminium strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified & directed.
Bharat Sales Corporation
S B ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .