Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹28.1 L+₹2.3 L (9.09%)Rejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L2 | Rejected-Finance Other than
lowest
bidder | |
| 3 | L3₹29.4 L+₹3.6 L (14.1%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L3 | Rejected-Finance Other than
lowest
bidder | |
| 4 | L4₹29.8 L+₹4.0 L (15.6%)Rejected-Finance UGLING ROAD OPP FIRE BRIDGE OFFICE LEH 194101 | LEH | LEH | LADAKH | 194101 | L4 | Rejected-Finance Other than
lowest
bidder | |
| 5 | L5₹32.7 L+₹6.9 L (26.8%)Rejected-Finance 1308 MAIN ROAD BABINACANTT DIST JHANSI 284 401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | L5 | Rejected-Finance Other than
lowest
bidder |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
27 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Babina
GE Babina, Babina Cantt-284401
REPAIR MAINTENANCE OF EXTERNAL LT ELECTRIC SUPPLY INSTALLATIONS FEEDER PILLARS CABLES SWITCHES ETC AT BABINA CANTT
2023_MES_577795_1
8083/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Babina
Class D Cat b(I)
8 documents required · 8 mandatory
₹500
Yes
GE Babina
₹66,000
Yes
8 Apr 2023
28 Jan 2023
1 Mar 2023
28 Jan 2023
27 Feb 2023
13 Feb 2023
Amount
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed.
Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm, factory made of specified make , complete all as specified and directed.
Supply , fix in repairs , commissioning and testing factory made LT feeder pillar , outdoor type pedstal type , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified.LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011, Type Test certificates for Short Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA.The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following ( The contractor should submit all Certificates before executing the job.) Panel drawings to be approved by GE before supply of panel on site.
M & L for earthing in repairs complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 2.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt upto 1.5 meter depth all around the earth plate and connected to earth lead of GI strip 24x4 mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanized iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. 2. Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit . On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.
S & F in replacement of change over switch with advanced neutral, OFF LOAD, 315 Amps, 4 pole, AC 415 Volt, side handle operated complete all as specified and directed.
S & F in replacement of change over switch with advanced neutral, OFF LOAD, 200 Amps, 4 pole, AC 415 Volt, side handle operated complete all as specified and directed.
S & F in replacement of change over switch with advanced neutral, OFF LOAD, 100 Amps, 4 pole, AC 415 Volt, side handle operated complete all as specified and directed.
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 16 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 10 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 6 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 4 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections etc complete all as specified and direcetd.
S&F in replacement KIT KAT TPN 415 Volt 50 Hz 3 P with HRC fuse suitable for interior mounting in panel of capoacity 100 Amp etc complete all as specified and direcetd.
Supply & fixing of MCCB of capacity 415 volts 3 pole 63 to 100 Amps 16 KA with fixed thermal & magnetic settings including taking out unserviceable MCCB from panels & connections of cables with thimbles etc incl. taking out cable from loop complete all as directed and specified.
Supply & fixing of MCCB of capacity 415 volts 3 pole 160 to 200 Amps 25 KA with fixed thermal & magnetic settings including taking out unserviceable MCCB from panels & connections of cables with thimbles etc incl. taking out cable from loop complete all as directed and specified.
Supply & fixing of MCCB of capacity 415 volts 3 pole 250 Amps 35 KA with fixed thermal & magnetic settings including taking out unserviceable MCCB from panels & connections of cables with thimbles etc incl. taking out cable from loop complete all as directed and specified.
Supply & fixing of MCCB of capacity 415 volts 3 pole 400 Amps 35 KA with fixed thermal & magnetic settings including taking out unserviceable MCCB from panels & connections of cables with thimbles etc incl. taking out cable from loop complete all as directed and specified.
Supply & fixing of MCCB of capacity 415 volts 3 pole 630 Amps 35 KA with fixed thermal & magnetic settings including taking out unserviceable MCCB from panels & connections of cables with thimbles etc incl. taking out cable from loop complete all as directed and specified.
Supply,laying and testing in replacement of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 50 sqmm x3.5 core as per IS 7092 Pt-I complete all as specified and as directed.
Supply,laying and testing in replacement of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 35 sqmm x3.5 core as per IS 7092 Pt-I complete all as specified and as directed.
Supply,laying and testing in replacement of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 16 sqmm x4 core as per IS 7092 Pt-I complete all as specified and as directed.
Taking out under ground, HT/LT cables, any sizes, by excavation and earth work in any type of soil, removing bricks or PCC tiles of any size, re-laying in the same trenches for re-routing /after rectification of fault as required complete all as specified and directed NOTE:- (i) Additional bricks, sand shall be measured & paid for separetely. (ii) Retrieved serviceable bricks or PCC cable cover and sand shall be re-laid on the cable & the cost for the same is deemed to be included in the unit rate. (iii) Cost for excavation, R&F, removing shall be included in quoted rate.
S&F for replacement & testing commissioning of outdoor type bus bar panel weather proof MS cubical panel board made of 3 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 300 Amp capacity with MCCB 4 pole of Capacity 200 Amp 25 KA (Ics =Icu=100%) including one coat of redoxide and two coat of enamel paint powder coated, mounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed.
M/S Kharya Associates
SHRI HARI CONSTRUCTION
J K Enterprises
M/S RAJ KUMAR SINGH
BHARADWAJ BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .