Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹47.4 L+₹4.4 L (10.3%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹48.0 L+₹5.0 L (11.7%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹48.2 L+₹5.3 L (12.3%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹49.8 L+₹6.8 L (15.9%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹46.9 L
EMD Value
₹93,800
Closing Date
23 Dec 2021, 6:00 pmClosed
GE I R AND EAST BANGALORE
GE I RD East Bangalore 560093
REPAIR REPLACMENT TO AREA LIGHTS CABLES CONDUCTORS INSULATOR BOX EARTHING AND CONNECTED WORKS UNDER AGE EM R D EAST BANGALORE
2021_MES_491971_1
8191
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND EAST BANGALORE
D b (i)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND EAST BANGALORE
₹93,800
Yes
17 Mar 2022
2 Dec 2021
25 Dec 2021
2 Dec 2021
23 Dec 2021
18 Dec 2021
3 Dec 2021 - 11 Dec 2021
Amount
Excavation in tranches n.exc 1.5 mtr wide and n. exc 1.5 mtr in depth and getting out in soft/loose soil for laying of UG cable complete all as directed
All as per item No 1 here-in-before, but for each additional 1.5 mtr or part thereof in depth beyond the first 1.5 mtr for foundation of poles complete
Removal of surplus soil to a distance n.exc 50mtr a part and depositing where directed n.exc 1.5 mtr above the starting point all as directed.
Returning filling and including spreading leveling ,Watering and well ramming in layers n.exc 25cm in soft loose soil all as directed
Material and labour for Sand cushioning to under ground cable providing with a layer 8cm thick before laying the cable and 15 cm thick after laying the cable complete all as specified and as directed Note: Punned thickness only will be measured for the purpose of payment.
M&L for common burnt clay building bricks sub class 'B' laid in trenches over sand cushioning for protection of UG cable in trenches complete
Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1:2:4, type B-1 100mm thick complete all as specified and directed by Engr-in-Charge. Note :- PCC shall be measured separately.
M&L PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) for making good the disturbed portion of road/floor/platform etc including form work compaction etc all as specfied and as directed by Engineer-in-Charge.
Taking down the old unserviceable existing LT UG cable of any size from 2 /3 /3.5/4 core 25 sqmm to 240 sqmm in trenches / pipes / pole for attanding the repair, refixing / relaying back in trenches fixed on poles with complete connection all as specified and directed by Engineer-in-Charge.
Note-: a). Excavation and earth work will be measured and paid seperately under relevant item. b) Sand & Brick to be safly / properly stagnated and reused as directed by Eng -in- charge. c) If the existing cable become faulty and can not be useful, then cable will be measured and paid separately relevent items.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of the following size complete connection with proper through cable lugs all as directed directed and specified by Engineer-in-Charge.
All as item No. 10 but of size 10 sqmm 4.0 core.
All as item No. 10 but of size 16 sqmm 4.0 core.
All as item No. 10 but of size 25 sqmm 3.5 core.
All as item No. 10 but of size 35 sqmm 3.5 core.
All as item No. 10 but of size 50 sqmm 3.5 core.
All as item No. 10 but of size 70 sq mm 3.5 core.
All as item No. 10 but of size 90 sq mm 3.5 core.
All as item No. 10 but of size 120 sq mm 3.5 core.
All as item No. 10 but of size 150 sq mm 3.5 core.
All as item No. 10 but of size 185 sq mm 3.5 core.
All as item No. 10 but of size 240 sq mm 3.5 core.
M & L for GI pipe medium grade, for road crossing / on wall / on pole for cable protection of following size:-
40 mm dia
50 mm dia
80 mm dia
100 MM dia
Supply & fix cable jointing kit for LT 1100 Volt grade cable for straight through joint complete with jointing material (Epoxy Based ) and accessories suitable for XLPE / PVC armoured with AI conductor cable of following sizes including taking out the loop of defective cable complete all as specified.:- Note : Excavation part will be measured and paid separately
6 to 16 Sqmm 4 Core/3.5 Core
25 to 50 Sqmm 3.5 Core
70 to 150 Sqmm 3.5 Core
185 to 240 Sqmm 3.5 Core
Note :- Excavation & earth work will be measured and paid separately under relevant item.
M & Labour for strengthening and Restringing of LT over head ACSR conductor any size in overhead lines inlcuding removing and replacement of binding wire from insulators before stringing and rebinding of insulators after stringing complete all as specified and as directed by Engineer - in - Charge. Note : (i) If any insulator required then measured and paid separately. (ii) If ACSR conductor required then paid separately. (iii) Four / two wire measures as a each job.
Dismentaling of insulators of any size /rating from pole all as specified and as directed by Engineer-in-Charge.
M & L for pin type porcelain vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washer and one galvansied iron nut, 100 mm height, 65 mm dia suitable for working pressure 1100 volts including nut bolt complete all as specified and directed by Engineer - in - Charge.
M & L for shackle type porcelain, vitreous, white brown or green insulators 100 mm height 115 mm dia including galvanised mild steel straps, washers, insulators bolts, etc suitable for working pressure 1100 volts including nut bolts complete all as specified and directed by Engineer - in - Charge.
Dismanlting of old jumper, including supply and fixing new jumper connection at out point on LT over head line with suitable size of ASCR conductor 6/ 1x 2.56 mm (weasel) PG Clamps, alkathine sleaves complete of required length not exceeding 2 mtr including testing on completion complete all as specified and as directed by Engineer - in - Charge.
Dismantling of ACSR conductor service feeder 'or' distributor span ,Jumpers complete all as directed by Engineer-in-Charge.
M&L for LT ACSR conductor drawn of on existing steel tublar pole, including Binding wire, jumpers with alkathine pipe, PG clamps etc, complete all as directed by Engineer-in-Charge.
Dismantling of old steel tubular pole/RCC pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation, earth work as reqd & removing the same from site complete all as specified and as directed.
M & L steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410 SP-31(9.0 metre long)including painting with two coats of synthetic aluminium paint complete all as specified and as directed Make:Jindal/Calcutta Tubes.
M & L for PCC (1:3:6) type C2 using 40 mm graded aggregrate for pole foundation including compaction etc all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:2:4 type B1 (using 20 mm graded stoneaggregrate) for pole coping incl form work compaction etc all as specified and directed by Engineer-in-Charge.
Dismentaling of Stay assembly of any size /rating from site all as specified and as directed by Engineer-in-Charge.
M & L for fixing L T Pole Stay assemblies shall comprise of stay clamp, stay wire( 7/ 2.24MM ), stay insulator, stay grips, thimble staybow, on existing 20 mm dia stay rod excluding excavation ,concrete & stay plate ) complete
Dismantling of GI earth/guard wire of any size and remiving unserviceable GI wire from site complete all as specified and as directed.
M & L for galvanised steel wire, 3.15 or 4 mm dia fixing, stringing on pole, including winding, fixed directly on pole or used as cradles including taking down existing rusted GI wire complete all as specified and as directed by Engineer - in - Charge.
Cutting / Tiriming of Tree branches which are touching to HT over head lines and clearing the same up to 4 meter radius for span length not exceeding 45 to 55 meter complete all as specified and as directed by Engineer - in - Charge. (Note: Each span of 30-55 Mtrs will be considered as one length of span for payment purpose)
S & F GI Strip 32 x 6mm including joining complete with necessary GI bolts, nuts, washers etc laid in trench fixed on walls/poles complete including dismantling of existing u/s earth strips.
M & L for Painting of LT steel tubler swaged pole & bracket of any type and any size with one coat of aluminium paint with 2" height strip of black and yellow paint (each strip height is 2") at the height of 1 mtr above the ground level including marking of pole number over the coloured strip (height of the pole number 2") in black paint and to fix the radian streep / night reflector with trimming 1 mtr radius the street light pole complete all as specified and as directed by Engineer-in-Charge. Note: No any additional cost to be provide the contractor for T & P.
M & L for Painting of GI pipe suitable for posttop lanteen of any type / size with one coat of existing paint and cleaning the PCC area and minior repair the bottom portion by brush and after two coat of white wash complete all as specified and as directed by Engineer-in-Charge. Note : If PCC required then measured and paid separately.
Repair / Maintenance of the street light fittings / High bay light fittings/Flood light fittings on pole or building / Workshop (any height) by replacing the spares as given below:- Note : (i) The measurement of payment shall be made as per actual replacement of accessories, no extra cost will be paid to the contractor for T&P and tradesmen as required. (ii) Taking down the fitting as required for maintenance for cleaning or minor repairs such as screw, wires including taking down etc. (III) The cost of the same is deemed to be included in the rate quoted. (iv) The contractor shall depute one electrician and two helper on all working days in MES complaint cell for attending the complaint regarding the street light.
S & F in replacment of LED driver suitable for LED street light / flood light fittings (as requirment at site) of capacity upto 70 Watts of existing make complete as specified and as directed by Engineer-in-Charge.
S & F in replacement of LED driver suitable for LED street light / flood light fittings (as requirment at site) of capacity upto 70 to 150Watts of existing make complete as specified and as directed by Engineer-in-Charge.
S & F in replacement of LED driver suitable for LED street light / flood light fittings(as requirment at site) of capacity upto 150 to 250 Watts of existing make complete as specified and as directed by Engineer-in-Charge.
Taking down the High mast light fitting safely electrically /mannually from the pole at site and cleaning after minor repair and checking of all electric connections and remove the old unserviceable LED light fitting from the pole and replacement the drive (as required at site ) after replacement of drive complete checking connection and again reassamble complete all as specified and as directed by Engineer-in-Charge. Note :(i) Minior repairs are include the cost. (ii) If driver replacement requirment then measured and paid separately.
Supply and fixing LED street light fitting 20 Watt 230 V AC outdoor type with new generation energy saving and envirment friendly long life LED street light made up of pressure dia cast aluminium hausing with high power LED as a light source complete with driver, complete with IP 65/66 protection complete with all fixing arrangement including taking down old one. Make - Havells/CG /Surya
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with all fixing arrangement including taking down old one. Make - Havells/CG /Surya
Supply and fixing LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with all fixing arrangement including taking down old one.Make - Havells/CG /Surya
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with all fixing arrangement including taking down old one.Make - Havells/CG /Surya
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with all fixing arrangement including taking down old one. Make - Havells/CG /Surya
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with all fixing arrangement including taking down old one. Make - Havells/CG /Surya
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with all fixing arrangement including taking down old one.Make - Havells/CG /Surya
Supply and fixing LED flood light 200/210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with all fixing arrangement including taking down old one. Make - Havells/CG /Surya
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete with all fixing arrangement including taking down old one.
S & F in replacement of post top lantern light fitting with LED 16 Watts energy saving environmental friendly, long life aesthetically designed die cast aluminium landscape luminaire for download lighting with high power LED as light source with all accessories and complete fixing arrangement with connection and painting of GI pipes with two coats of gray paint including dismantling old one. Make - Havells Cat No-Mushroom or equivalent in Havells/Philips
S & F in replacement of post top lantern light fitting with LED 35 Watts design from the renaissance era yet with a moden look using new generation technology in LED to enliven your out door areas in perfect synchonisation with functionlity and aesthetics with all accessories and complete fixing arrangement and painting of GI pipes with two coats of gray paint including dismantling old one. Make - Havells Cat No Victoria equivalent in Havells/Philips
S & F in replacement of post top lantern light fitting with LED 45 Watts design from the decorative indirect post top for garden & landscape lighting with IP 65 Protectionwith resistance to impact and corrosion and anti glare and uniform distribution with all accessories and complete fixing arrangement including dismantling old one. Make - Crompton Cat No -LPTOI-45-CDL equivalent in Havells/Philips
M & L for PVC insulated weatherproof unarmoured sheathed 1100 volts grade stranded twin core copper conductor cable of size 1.5 Sqmm including taking down the old unserviceable street light cables complete all as specified.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of standard conductor 6 sq. mm nominal cross section in service connections of complete connection all as specified and as directed by Engineer-in-Charge.
M & L for replacement of unserviceable MS clamp with new clamp made out of MS flat iron 25 x 5mm including fixing nuts bolts, washers etc and painting with two coats of syntetic enamel paint over a coat of red oxide primer complete all as directed
Dismantling of cross arms of MS channel or angle section etc complete fixed on RCC/steel tubular poles carefully including separating and setting a side serviceable cross-arms for reuse in the work and removing unserviceable cross arms complete all as specified and as directed.
S & F cross arms, bracing, support, clamps etc made out of mild steel channel or angle section of reqd size and shape including clamp, back plate with bolts, nuts & washers drilled for insulator bolts, welding, bending cold or hot in any shape or size including all fixing arrangement on HT over head line and painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed by Engr-in-Charge.
Supply and fix street light end cap bracket (as per sample) fixed on pole with all fixing arrangement including electric connection and dismantling of existing unserviceable bracket complete all as specified and directed by Engineer-in-Charge.
Supply and fix street light bracket made out of 40mm dia GI Pipe medium grade of 1.5 m long bent to shape with all fixing arrangement including dismantling of existing unserviceable bracket complete all as specified and directed by Engineer-in-Charge.
Supply and fix pole mounted junction box (street light boxes) Top hinged Door fixed with hinbges on top of size 275mm x 135 x 110mm made out of FRP sheet with weather proof, locking arrangements vertical operated with one No. 6 /10 Amps MCB SP, EPOXY. Technical connector upto 8 ways, fixed on pole with 25mm x 3mm MS flat iron clamps and painting with two coats of synthetic enamel paint over one coat ofo red oxide primer for fixing clamps all as specified and directed inlcuding dismantling of existing u/s loop-in-box. Make-Syntex/Hensel
M & L for anti-climbing devices spikes type fabricated out of M.S. bars (round, square and flat) including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole including complete painting with two coat of aluminium paint over a coat of red oxide primer all as specified and directed by Engr-in-Charge.
M & L danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, bigures and conventional shull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size of HT 25 x 20 cm size.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion as specified and as directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron streep of size 32 x 6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion as specified and as directed by Engineer-in-Charge.
Supply & fix MES sub station boards of size 4 x 3 feet with SS 50mm pipe support ground aprox 6 feet hight errected in earth with cement concrete, including excavation as required, with superior quality ACP boards with radium/reflective blue letters with maxium 70 letters with maxium size in English with stainless steel frame work complete with fixing of LED fittings inside the board including the complete wiring work with complete connection all as specified and as directed by Engineer - in - charge. Note :- Display letter for the boards will be ' name of installation' and "location" all as directed.
Supply & fix MES sub station boards of size 4 x 2 feet with SS 50mm pipe support ground aprox 6 feet hight errected in earth with cement concrete, including excavation as required, with superior quality ACP boards with radium/reflective blue letters with maxium 70 letters with maxium size in English with stainless steel frame work complete all as specified by directed by Engineer - in - charge. Note :- Display letter for the boards will be ' name of installation' and "location" all as directed.
S & Fix Installation Notice board of size 5 x 4 feet (as per sample) of SS cover in out side including fixing on wall all as specified and as directed by Engineer-in-Charge.
S & Fix Installation of Key box 2 x 2 feet (as per sample) of wooden and for the proper locking arrangement and fixing of glass in front side including fixing on wall all as specified and as directed by Engineer-in-Charge.
Supply and fix astronomical time switches along with timelite DBs without battery backup 3P module , 24 hours programme every 15min , current capacity 16A complete including necessary connectins and make functinal all as specified and directed Make : Indo Asian Cat Part No: TL 040A50
Fixing only LED street light /flood light fittings of any rating / wattage including complete connection with fixing arrangement all as specified and as directed by Engineer-in-Charge including taking down. Note : Street light /flood light fitting will be issued under schdule 'B'
S & Fix PVC Moulded LED strip with water proof and IP 65 protection variant and bendable material of the streep design in pole (Tripple colour )as Indian flag patten/colour makes it ideal for flexible decoration including all fixing arrangement in pole as specified and as directed by Engineer-in-Charge. Make : Crompton or Equilent in Havells/Philips Note :(i) Each colour strip contain length 6.0 Mtr. (ii) No any addl cost to be provided to the contractor.
S & Fix one driver for connection of LED strip suitable for fixing all electric connection with all fixing arrangement as specified and as directed by Engineer-in-Charge. Make : Crompton or Equilent in Havells/Philips
S & F in replacement of bollard fiting with LED energy saving , environmental friendly, long life aesthetically designed die cast aluminium landscape luminaire for download lighting with high power LED as light source of 8 Watts with all accessories complete including dismantling old one of Make - Havells CAT No. BAMBOOBL8WLED757PSYMTOPC or equivalent in Crompton Greaves / Bajaj /Phillilps
RASHMI BUILDERS
eurekaenterprises
ANAND REFRIGERATION
SAPTHAGIRI CONSTRUCTIONS
Teleconcepts (India) Pvt Ltd
Rajapriyaconstruction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .