Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.2 LAccepted-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹10.0 L+₹61,244.55 (6.55%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹10.7 L+₹1.4 L (14.7%)Rejected-Finance | 3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
18 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I)
AGE (I) MES FATEHGARH
PROVISION OF CERTAIN B/R and E/M REVENUE WORKS / LBW WORKS/MINOR WORK UNDER AGE(I) FATEHGARH.
2020_MES_405006_3
GE/FAT/ET-26 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
120 days
AGE (I) MES FATEHGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE (I) FATEHGARH
₹20,000
Yes
10 Apr 2021
2 Mar 2021
20 Mar 2021
2 Mar 2021
18 Mar 2021
2 Mar 2021
60 days
Amount
M&L for excavation in trenches for foundation/under ground cable in soft / loose soil n exc 1.5 m wide and n exc 1.5 m in depth complete all as specified and directed.
M&L cement concrete 1:4:8 Type D2 ( 40 mm graded aggregate) as in foundation complete all as specified and directed.
M&L for Reinforced Cement concrete (nominal mix) (20 mm graded aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced Cement concrete (nominal mix) (20 mm graded aggregate) in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Reinforced Cement concrete (nominal mix) (20 mm graded aggregate) in beams, cantilevers, bressumers, lintels over 1.5 m span complete all as specified and directed.
M&L for Reinforced Cement concrete (nominal mix) (20 mm graded aggregate) in slabs supported on walls, beams and columns , in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns , raft nd raft beams, sides and soffits ( if any) of foundation and plinth beams; and similar work; vertical or to better fair finished smooth surfaced of councrete. complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions to fair finished smooth surfaced of councrete complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders,bresumers, lntels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc. to better fair finished smooth surfaced of councrete.complete all as specified and directed.
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia. Or securing with clips quality conforming to complete all as specified and directed.
M&L for Mild steel TMT bars 8mm dia. and over up to and including 10 mm dia. in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips quality conforming to complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6m mean radious built in CM 1:6 etc complete all as specified and directed.
M&L Rendering 15 mm thick in CM(1:6) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete as all specified.
M&L for rendering on walls 15mm thick in cement mortar (1:4) on fair faces of brick work with WPC as per manufacturer instruction surface finished even and fair with out using extra cement complete all as specified and directed. Note : WPC will be paid separtely.
M&L Rendering 5 mm thick in CM(1:3) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement complete as all specified and directed
M&L Rendering 20 mm thick in CM(1:3) on fair faces of brick work or concrete surfaces of roof to be finished even and smooth without using extra cement with WPC @ as per manufacturer instruction complete all as specified and directed. Note : WPC will be paid separtely.
Supply only integral water proofing compound
M&L for sand filling under floor for in foundation including watering and consolidation complete all as specified and directed
M&L broken stone hard core of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rolled/ rammed to a true surfaces complete all as specified and directed.
M&L Cement concrete type D-2 , 1:4:8 (40 mm graded aggregate) 100 mm thick in sub floor complete all as specified and directed.
M&L 100mm thick Cement concrete type B-2 , 1:2:4 (40 mm graded aggregate) finishing cement concrete surface using extra cement even and smooth including necessary form work, laid in alternate bays, and joints filled with mixture of sand and bitumen complete all as specified and directed.
S&F glazed coloured ceramic tiles of sizes 350x250x7mm thick/ 450x300x7mm thick on vertical surface over 10mm thick rendering in CM 1:4 complete all as specified and directed.
M & L Two coats of Oil bound distemper on new plastered wall suerfaces over a coat of alkali resistant primer over 3mm thick wall putty including preparation complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceilling complete all as specified and directed.
M & L for two coats of Cement based paint over a coat of alkali resistant primer on new plastered wall surfaces including preparation complete all as specified and directed.
S&F mild steel framed work of angle or any other section (grade 410 - 0 or Fe 310-0) as in door and door frame, gates of angle frame work etc including necessary welding etc complete all as specified and directed.
S&F Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces,etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of and similar work con- forming to Gde Fe-410 complete all as specified and directed.
S&F 0.80mm thick Mild steel, plain, black sheet in hearths ; covering to door shutters; covering to door chowkhats ( frames); chullah hoods ; water tanks; water troughs; ducts;urinal troughs and funnels, etc. cut to size , edges beaded if directed, holes punched; including round headed screws , clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams, including bending, turning up, mitred angles, stopped ends, outlets , etc. as required
M & L for PCC 1 : 3 : 6 type C1 using 20 mm graded stone aggregate as in fixing of hold fast including necessary form work complete all as specifed and directed.
S&F for Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks all as specified
M&L 75 mm thick PCC 1:3:6 type C-2 using 20 mm graded aggregates as in plinth protection and finishing even & smooth without using extra cement laid in bays complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil complete all as specified and directed.
Returning, filling in including spreading, leveving, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material exc 250 m but not exc 500 m and depositing where directed complete all as specified and directed.
M&L for point wiring one light/fan/exhaust fan point controlled by one switch with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed steel conduit with fittings (ISI marked) not less than 20 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover ISI marked suitable for housing/ fixing flamproof switches etc complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
...ditto as above But for point wiring for one 15 Amp 6 Pin switch socket out let on independent board with using 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded cable ….dito….
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply and fixing in replacement MCB distribution board SPN 240 Volt 4 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
S&F in replacement of MCB SPN 16-40 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F MCB in replacement of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor,6 sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm uspension wire, one twin core cable flat complete all as specified and directed.
S&F surface and wall mounted flameproof fitting LED Single tube,1x28 w, 230v Energy efficient T5,Surface mounted DECORATIVE MIRROR OPTIC TYPE, with electronic ballasts, bipin holders, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) complete all as directed incl dismantling of exsisting earthing. ( Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
S & F House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos 90 degree bends. M.S. hook and stay or guy complete all as specified and directed
Supply, installation, testing and comissioning of water cooler storage type, ISI marked, Electric driven 230 Volt, 50 Hz, Single Phase Supply complete with all internal accessories, stainless steel body and tank, power saving PUF insulation, adjustable cold water thermostat, 10 degree to 25 degree centigrade auto cut off facility, overload protection, stainless steel front panel, extended plastic legs, eco-friencly version with non CFC refrigerant, energy efficient conforming to relevant IS and PF shall not be less than 0.85 compressor and approx storage capacity of 80 litres and nominal cooling capacity of 40 litres per hour and including writing MES No. complete all as specified and as directed.
S&F 16 Amp switch socket combination 6 Pin 2 in 1, flush type 240 Volt complete.
M&L for sub main wiring with two single core 4.0 Sqmm FRLS copper conductor PVC insulated unsheathed cable rade including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 1.5 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 4 sqmm FRLS and one run of 1.5 sqmm FRLS copper conductor shall be measured as one unit length.)
M&L for Cutting Screwing existing size of pipe 25 to 32 mm steel tubing for alteratio or additions (Each cut measured or lengthening screw on pipe to from connector) complete all as specified and directed
S&F of 15 mm stop valves, fancy type chromium plated with long shank and cup (concealed type) complete all as specified and directed
S&L of 15 mm GI tubing medium grade galvanised with all fitting and fixed complete to wall and ceilings or laying in floos complete all as specified and directed
S&F of isolator DP 20 Amps rating complete all as specified and as directed
S&F sheet metal enclosures 2-way DB 240 V complete all as specified and as directed .
S&F pvc connection heavey duty with brass/PTMT nuts of reqd length not exceeding 300 mm with rubber & PVC washer suitable for 15 mm bore GI pipe complete all as specified and as directed
M&L for sand cushioning to U/G cable in layers of 23 cm thick( 8 Cm before laying the cable and 15 Cm thick after laying the cable) in trenches complete all as specified and directed. Note :- Only Puned down volume shall be measured.
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 70 Sqmm 3.5 core complete all as specified and as directed.
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
S&F of 50 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified and directed.
S & F on load changeover switches 4 pole, 63 Amp complete with enclosures complete all as specified and directed.
S & F MCCB 100 Amps , 4 pole, 415 volts , 50 Hz , 16 KA breaking capacity with adjustable thermal magnetic release, with spreader links on both sides complete all as specified and directed.
S&F in replacement of Busbar chamber in sheet metal enclosure 200 Amp, 8 way TPN 415 Volt of aluminium busbar drilled holes including cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed.
Supply and fixing of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 Sqmm 4 core complete all as specified and directed.
M&L steel tubular swaged pole type 410 SP 55 (11 Mtr. Long) complete with cast iron base plate/final taper plug, bolt, nuts and washers including excavation earth work in any type of soil , PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in plinth block ,copping PCC 1:2:4 , including two coats of aluminium painting over a coat of red oxide primer on external surface and black bituminous paint on internal surface of pole and external surface upto planting depth as specified in SSR 2009 Part-I including writing pole numbers with white lettering on black background and marking black & yellow strips upto 1.5 mtr height complete all as specified and directed.
M & L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
S&F 120 Watt powder coated (PDC) aluminium LED flood Light fitting with sealed toughened glass cover , SMD LED with secondary lens complete all as specified and as directed.
M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10 sqmm 4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 04 Nos of single pole MCB SP 0.5-3Amp 'C' series inside the box and all specified and directed.
S&F PVC insulated standard copper cable (round) wire lead 3 core 1100 volt grade of size 1.5 sqmm etc complete all as specified and directed.( Make: Havells/Plaza/Polycab.)
MS. BK BROTHERS AND CO
M/S S P CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .