Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | ₹1.0 Cr | L1 | Accepted-AOC QUOTED LOWEST |
| 2 | L2₹1.0 Cr+₹1.1 L (1.04%)Rejected-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹1.0 Cr+₹1.1 L (1.04%) | L2 | Rejected-AOC Not admitted |
| 3 | L3₹1.1 Cr+₹8.9 L (8.74%)Rejected-AOC 1ST FLOOR SIDDHI PUJA BUSINESS SQUARE SONY PAITHANI CHOWK NASHIK MAHARASHTRA INDIA PIN 422 002 | NASHIK | MAHARASHTRA | 422002 | ₹1.1 Cr+₹8.9 L (8.74%) | L3 | Rejected-AOC Not admitted |
| 4 | L4₹1.1 Cr+₹12.4 L (12.2%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹1.1 Cr+₹12.4 L (12.2%) | L4 | Rejected-AOC Not admitted |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
5 Oct 2020, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS TO BUILDING NO P-07 DSC LINE AT INS TANAJI UNDER GE NW MANKHURD
2020_MES_367730_1
8852/E8
Open Tender
Civil Works
Item Rate
300 days
INS TANAJI
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹2.2 L
Yes
6 Nov 2020
27 Aug 2020
9 Oct 2020
27 Aug 2020
5 Oct 2020
25 Sept 2020
Amount
Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed
M&L for 20 mm thick polymer modified ready mix cement based plaster in two layers (12 + 8 mm) on the wall surfaces, top layer of 8 mm mixed with liquid water proofing compound in the proportion as per manufacturer’s instructions and including finishing the surfaces of the top layer even and smooth, complete all as specified and directed, Make : Easy plast from M/s wall plast or chemplast or Readiplast from ultratech. Notes : (i) The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with the ready mix plaster and nothing extra shall be payable on this account. (ii) WPC shall be paid for separately.
M&L for 5 mm thick polymer modified ready mix cement based plaster on surfaces of ceiling including finishing the surface even & smooth without using extra cement, complete all as specified and as directed. Make : Easy plast from M/s wall plast or chemplast or Readiplast from ultratech. Note: The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with the ready mix plaster and nothing extra shall be payable on this account.
M&L for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surfaces even and smooth, complete all as specified and directed, Make : Easy plast from M/s wall plast or chemplast or Readiplast from ultratech. Note : The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with the ready mix plaster and nothing extra shall be payable on this account.
Supply only integral water proofing compound, complete all as specified and directed.
Chipping, removing carefully loose/damaged concrete incl plastering from RCC surfaces of columns, beams, soffits of slabs etc by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land, complete all as specified and directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement wire/ rotary wire brush, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 6 hr between the coats, and applying protective coating IPNET-RB complete all as specified and directed.
M&L for applying anti corrosive coating IP Net-RB in two coats with time interval of 6 hours, the application shall be done by brush after cleaning/wire brushing the exposed steel surfaces complete all as specified and directed.
Providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster confirming to ASTM-C-882-91 (Arizona Slant Shear test ) to ensure bond between and new concrete by brush application complete all as specified and directed.
M&L for Drilling and rohibb teflon nozzles in RCC members, including drilling holes of 12 mm dia, 50 to 10 mm deep holes in structural members at the intervals of 500 centre to centre in staggered manner or as directed in RCC structural element work shall be carried out as under:- (i) Cleaning of holes, clean the holes by air bowler prior to fixing nozzles. (ii) Fixing of nozzles, Insert 12 mm dia Rohibb Teflon nozzles in cleaned holes, External end of nozzles to be machince to recive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum 12 hrs
M & L for Grouting injecting low viscosity high moleculer weight thermosett /monopol or equivalent polymer by pressure and using injecter with accessorises till nozzles refused the accept the grout incliding , mixing of materials , mixing material components quantities as per mfg instruction by weight batching grouting fill the grouting gun with material maintain desired pressure in the gun air by compreser maintion thr pressure at exit ( 3 to 4 kg / cm2 ) by monitering pressure gauge at exit ., gout the material through pre fixed nozzles in the structurel elements till its refusal . seal the nozzles with putty after the refusal , moniter leakages through other nozzles while grouting and seal them as per requirement complete all as specfied and directed.
M&L for building up the profile of structural members by using Polymer Modified mortar (PMM) of Krishna Concem or HB mortar of Dr Fixit while the bonding agent is still sticking upto 20mm thick incl levelling profile complete all as specified and directed.
M&L for building up the profile of structural members by using Polymer Modified mortar (PMM) of Krishna Concem or HB mortar of Dr Fixit while the bonding agent is still sticking upto 40mm thick incl levelling profile complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 40mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from M/s. Krishna Conchem (Molith MC) or equivalent of Dr. Fixit as approved by GE at any level and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing, laying, levelling, finishing, curing etc as per manufacturer's specifications complete all as specified and directed. (Note : For payment purposes, actual weight of mircoconcrete used shall only be considered). all as per manufacturer instruction.
M & L for RCC M-30 (Design Mix) as in repair concrete mix with admixture super con 100 of krishna conchem or equivalent suitable for free flow including necessary formwork all as specified and directed
M & L for TMT bars any dia in various structural RCC element like column, beam, slab etc incl cutting, bending fix the bar with welding as required at site and all revavent works like anchiring of the bars in existing RCC members complete all as specified and directed
M & L for making up lost section of concrete/mortar with thixotropic repair mortar is one component thixotropic dual shrinkage compensated fiber reinforcement formulation for structural members. Built up section by hand packing as per manufacturers specification, applied by mean of hand gloves by expert applicator, the rehabilitated surface should be fre from air gaps, voids should be in line with existing required line and line with existing surface, incl curing, cleaning the area etc, complete. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of aualified supervisor etc... complte all as specified and directed. (Make : SPconcare/Sika/Krishna Conchem)
M & L for siingle ply undirectional carbon fibre of 400 GSM inclusive of surface preparation, priming and saturant application as per the dry lay up precess and sprinkling of sand on the wet final saturant coat for giving protection screed o the top complete all as specifed and directed.
M & L for 10 mm effective dia carbon fiber anchore including drilling holes of 12 mm dia. 100 mm deep hole across the width and length span to fiber glass treatment , of readymade glass fiber anchore with spread of 100 mm. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of aualified supervisor etc complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying three coat of white wash mixed with glue/Fevicol and blue, complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper with roller over one coat of primer over a coat of 1.5 mm thick putty finished complete all as specified and directed.
M & L for preparation of old plastered surfaces of wall and applying one coat of white wash mixed with glue/Fevicol and blue, complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceilling and applying three coat of white wash mixed with glue/Fevicol and blue, complete all as specified and directed.
M & L for preparation of old plastered surfaces of ceiling and applying one coat of white wash mixed with glue/Fevicol and blue, complete all as specified and directed.
M&L for complete removal of existing treatment of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down water etc. apply two coats of oil bound distemper with roller over 3mm thick wall care putty complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15 cm thick (above or below ground level) and removing the retrieved debris outside MD land, complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, mechanically sweeping clean and washing down with water to remove dust etc
All as per item No 27 above, but as in skirting, complete all as specified and directed.
M&L for providing 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement and making joint, filling sealing compound, complete all as specified and directed.
M&L for providing 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in flooring, surfaces finished even & smooth without using extra cement including necessary form work etc, complete all as specified and directed.
M & L for prepolished Chequered cement concrete tiles 30cm x 30cm x 20mm thick, set, jointed and pointed in near cement slurry in floors with grey cement and pigments over and including 20 mm screed bed or bedding layer in CM 1:6 complete all as specifed and directed.
Dismantling boarding any description fixed in any position with nails complete all as specified and directed .
S & F for hot dipped GI imposed grid with 24mm wide T section exposed flanges powder coated frame work comprising of main runner made from 0.33 mm thick GS sheet of size 24mm x 32mm x 3000 mm @1200 mm C/C GI wire 4mm dia fixed by rawl plug,level adjusters and screws etc flush fitting of 1200mm long cross tee interlocked between main runners @ 600mm c/c to form 1200mm x 600mm modules cross tee longer than 600 mm to be supported independently 600mm x 600mm modules shall be formed by fitting 600 mm long cross tee centrally between 1200mm cross tee ,perimeter wall angle shall be GS of size 19mmx19mm and 0.45 mm thick 300mm long including 600mm x 600mm x 8 to 10mm thick armstrong gypsum reinforced board with painting with two coat of plastic emulsion paint over primer complete all as specified.
Dismantling floor, hearth or wall tiling and stone slabs including cement mortar bedding (but not backing), removing rubbish off the premises outside MD Land complete all as specified and directed.
M&L for coloured Non-skid ceramic tiles 7 to 8mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.11 Sqm but not exceeding 0.16 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
M&L for coloured Non-skid ceramic tiles 7 to 8mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
M&L for coloured 300 x 200 x 7mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick cement mortar backing coat in CM 1:4 etc, complete all as specified and directed.
Demolition of lime concrete or lean concrete from sunken floor including floor tiles, hacking of surfaces after cleaning with wire brush (floor and adjoining walls) and disposing off debris outside MOD land complete all as specified and directed.
M & L for filling of lean concrete 1:5:10 type E2 (using 40 mm graded stone aggregates) in sunken portion, as per requirement complete all as specified and directed.
M & L for special treatment for sunken portion of WCs/Bath & toilet etc executed in following stages : Stage 1: Providing 15mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr.Fixit or Shalicrete 'R' of STP Ltd in the proportion/quantity all as per manufacturer's instructions. State 2 : Primer-Mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces. Stage 3 : Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) @ 1Kg/Sqm by brush all as per manufactuer's instructions. Stage 4: Laying fyber glass cloth (weight not less than 50gram/ Sqm) over the 1st coat while the coated surface is still sticky. Stage 5: After 6 to 7 hours interval, apply second coat i.e. final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/ Sqm by brush as per manufacturer's instructions. Stage 6: Providing 10mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250ml/50 Kg cement all as per manufacturer's instructions. Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. NOTE : (i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid . (ii) The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
Taking up or down steel water tubing and connections of size 15mm bore complete all as specified and directed.
Taking up or down steel water tubing, fittings and connections of size 20mm bore complete all as specified and directed.
Taking up or down steel water tubing, fittings and connections of size 40mm bore complete all as specified and directed.
Taking up or down steel water tubing, fittings and connections of size 50mm bore complete all as specified and directed.
Supply & fix 16mm outer dameter of pipe of 3-layer PP-R Poly propylene random cpolymer concrelaed pipes SDR 7.4 (PN-16) UV stabilized and anti microbial fusion welded having thermal stability for hot & vold water supply incl all PP-R plain & brass threaded polyproplene random fittings fixed complete to walls, ceilings or in floors complete all as specified and directed.
All as per item No 45 above, but 20 mm bore.
M&L for providing and applying Concrete Curing Compound (comply with ASTM C309-90) over the plastered surface. The curing compound shall be a white, low viscosity wax emulsion incorporating a special alkali reactive emulsion breaking system. This impervious film prevents excessive water evaporation which in turn permits more efficient cement hydration, thus reducing shrinkage and increasing durability. It shall have a specific gravity of 1.02 and the minimum application temperature shall be 10°C and shall have a coverage of 8-10m² /litre /coat complete all as specified and directed. Make ;-Thermax Ltd /SNI Infra/M/s Sika India Pvt Ltd/M/s Fosroc Chemicals/ M/s Krishna konchem or equivalent.
Supply & fix 40 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Supply & fix 50 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S & F 75 mm dia outlet PVC (SWR) floor trap plain with grating including jointing with solvent cement
S&F in repair PVC connections 15 mm size with PTMT nuts of length 600 mm, complete all as specified and as directed.
S & F in repairs flushing cistern, 10 Ltrs. Capacity, PVC valveless, syphonic action type with dual flushing system, low level,white with inlet, ball valve,float and handle including brackets, flush pipe of polyethylene of low or high density or PVC, 32 mm dia, complete all as specified and directed.
S&F 15 mm bore bib taps, cast copper alloy with crutch or butterfly handle, fancy type, chromium plated, screwed for iron pipe or for brass ferrule, complete all as specified.
S&F pillar taps, cast copper alloy, chromium plated, screwed down, high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe of 15mm bore, complete all as specified and directed.
S&F Stop valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore, complete all as specified and directed.
S&F in repair Grating doom 125 mm dia with waste hole of PTMT (Minimum Weight 40 gram), complete all as specified and directed.
S&F in repair Swivel shower of PTMT any colour for fixing with 15mm bore pipe (Minimum weight 40gms), complete all as specified and directed.
S&F in repairs Vitreous China white wash hand basin, flat back, size 550 mm x 400 mm including mild steel angle brackets,CP brass fittings, waste, union, cutting for and pinning ends of brackets, complete all as specified and directed .Note :Pillar tap/ mixer will be measured and paid separately under respective item.
Demolition of stone slabs and tiles laid beded and pointed in any mortar of any description or thicknes in floors , aprons etc
M&L for 20 to 22 mm thick Black Jet, premium quality, Granite Slab (table rubbed and polished) as in cooking platforms, floors and the like and including provision of 15 mm thick cement mortar 1:4 bedding layer, pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc, complete as specified and directed.
M&L for providing 18 to 20 mm thick Kota stone of single peice as required size as in window cills and jambs etc (to the full width of walls) over and including 10 mm thick cement mortar 1:4 bedding layer, jointed and pointed with grey cement paste and slurry, complete all as specified and directed.
M&L for half rounding to one edge of stone slabs as in steps,cooking platform and other similar situations, complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25 mm thick over 20 mm thick cement screed base CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L for Machine cut kota stone slab flooring 20-25 mm thick in riser of steps, skirting, dado and pillar over 20mm thick cement screed base CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
Taking down carefully existing aluminium sliding window shutters, taking down of existing broken 5 mm thick plain sheet glass from aluminium sliding window shutters including existing rubber gasket complete, supply and fixing 5 mm thick plain sheet glass with and including provision of new rubber gasket and re-fixing the shutters in existing position, complete all as specified and directed.
Taking down carefully existing aluminium sliding window shutters, taking down of existing stainless steel wire mesh from aluminium sliding window shutters including existing rubber gasket complete, supply and fixing stainless steel wire mesh of dia 0.36 mm and average width of aperture 1.40 mm with and including provision of "U" clip, re-fixing the shutters in existing position, complete all as specified and directed.
S&F in repair sheet glass 5mm thick ordinary quality for wooden shutters in any position with and including new wooden beads as required for securing, complete all as specified and directed.
Taking down carefully aluminium sliding window shutters from the frames or chowkhat and supply and fix New locking arrangement in place of old one and re-fixing the same shuters in existing position etc, complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc, complete all as specified and directed.
S&F mild steel Framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, framework of water tanks and similar work conforming to Fe -290 Grade -E-165, complete all as specified and directed.
S&F 20 mm dia brass chromium plated tubuler towel rail 'D' type 600 mm long between flanges, complete all as specified and directed.
M&L for leakage / seepage proof coating consisting of preparing the surfaces of existing exterior walls, parapet walls, chajjas, etc. with wire brush to remove all loose dirt, oil grease, etc. and cutting and filling cracks above 5mm thickness with Pidicrete URP of M/s Dr Fixit or with Plaster Seal of M/s STP Ltd or Chemistic Crack Seal Caulking compound (Acrylic Sealent) of M/s Chemistic and filling cracks less than 5mm with Crack X paste of M/s Dr Fixit or with Plaster Seal of M/s STP Ltd or Chemstic Crackseal Caulking compound (Acrylic Sealent) and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8 hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100 microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Note: Item No. 01 shall not be operated for the locations of Item No. 06 (ii) The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
S& F in repairs brass chromium plated curtain rod 20 mm dia, complete all as specified and directed.
S&F in repair brass chromium plated bracket for 20 mm dia curtain rod, complete all as specified and directed.
Demolition of brick/cement concrete (unreinforced) from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retreived debris out side MD land, all as specified and directed.
M&L for PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope including making rounded or chamfered on edges complete all as specified and directed.
M&L for cement plaster (1:4) with 10 mm thick to be finished smooth without using extra cement mixed with WPC @ 3% by weight of cement, and Recron 3 S fibre @ 0.5% of wt of cement complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
Supply only polyester triangular fibres as secondary in all type of concrete & and mortars complete all as specified and directed.
M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqcm using butane torch by torch application with 10cm side lap and 15cm end lap. Including one coat of solar reflective epoxy paint. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650 N/Sqcm and transverse not less than 450 N/Sqcm (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%. (xi) Over the membrane provided a finishing with solar reflective bitumen aluminium paint @ 0.10 Kg/ Sqm as prescribed by manufacturer. complete all as specified and directed.
M&L for rendering 10 mm thick on brick masonry or concrete surfaces as in parapet wall, coving of pillars in CM 1:4 mixed with WPC @ 2% by weight of cement mixed with Recon 35 fiber @ 0.5% by weight of cement including finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. (Note: WPC will be measured and paid 3S to be measured separately).
Taking down existing Rain Water Pipe of any description and in lieu S & F of 110 mm bore UPVC (SWR) soil, waste, ventilating pipe type 'A', single socketed, (ISI Marked) in any length with and including ruber ring joints, complete fixed to wall with necessary stay clamps/laid in trenches/floor etc, complete all as specified and directed.
Taking down existing Rain Water Pipe of any description and in lieu S & F of 75 mm bore UPVC (SWR) soil, waste, ventilating pipe type 'A', single socketed, (ISI Marked) in any length with and including ruber ring joints, complete fixed to wall with necessary stay clamps/laid in trenches/floor etc, complete all as specified and directed.
S&F in repairs, vitreous China Ist quality squatting pan (Orissa pattern), of size 580x440 mm, white, with and including 'P' or 'S' trap, integral foot rests, lime concrete bedding inlcuding dismantling existing lime concrete bedding, unserviceable connections etc and connecting up, complete all as specified and directed.
S&F 110 mm bore UPVC (SWR) branch piece, single (single Y) equal or unequal with and including rubber ring joints complete all as specified and directed.
Removing plant/growth including its roots upto 1.00 m of plant height at any location/at any storey and of any description and treating the surfaces with Acid (HCL) and making good surfaces with cement mortar 1:4, complete all as specified and directed.
S&F in repairs, white vitreous China wash down water closet pan (pedestal pattern), Ist quality inlcuding plastic water closet seat white, closed pattern with flat bottom and cover and Mild Steel CP or aluminised hinging device, complete all as specified and directed. Note: Flushing cistern, flush pipe will be measured separately.
S&F 110 mm bore UPVC (SWR) Bends with and including rubber ring joints, complete all as specified and directed.
S&F 75 mm bore UPVC (SWR) branch piece single (Single Y ) equal or unequal with and including rubber ring joints, complete all as specified and directed.
S&F 75 mm bore UPVC (SWR) Bends with and including rubber ring joints, complete all as specified and directed.
S&F 110 mm bore UPVC (SWR) branch piece single (Single T ) equal or unequal with and including rubber ring joints, complete all as specified and directed.
S&F 75 mm bore UPVC (SWR) branch piece single (Single T ) equal or unequal with and including rubber ring joints, complete all as specified and directed.
S&F 75 mm bore UPVC (SWR) branch piece double (double Y ) equal or unequal with and including rubber ring joints, complete all as specified and directed.
S&F 110 mm bore UPVC (SWR) branch piece double (double Y ) equal or unequal with and including rubber ring joints, complete all as specified and directed.
Taking down chowkats or frames, exc 1.5 Sqm but not exc 4 Sqm each with shutters (Without taking of shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces, complete all as specified and directed.
S&F Second class Hard Wood (SAL/Hollock/Kalasiris) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints etc complete all as specified and directed.
S&F factory made Glazed and skelton shutters, 35 mm thick of Second class hard wood open rebated and prepared to receive glass, gauge etc without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), complete all as specified and as directed.
S&F Factory made Plain framed, panelled shutters, 35 mm thick of second class hard wood (Hollock) (any numbers of panels) with panels of 12 mm thick veneered particle board exterior grade medium density with commercial veneering on both faces with sheesham wood beading all round the panel made out of 20 by 15 mm , on one side and fitted to chowkhats complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width or aperature 1.40 mm for fixing to wooden door/ window shutters in any position with new beads/ steel section as required for securing including dismantling of old jalli and painting to match with existing complete all as specified and as directed.
Taking down chowkats or frames, not exc 1.5 Sqm each with shutters (Without taking of shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces, and making good disturbed surface complete all as specified and directed.
S & F factory made solid PVC Door Frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and shown in drg for SI No. 8095 on ser page No. 160 in SSR-2010 (Pt-II).
S&F Factory Made Solid Panel PVC Door Shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet shall be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, as per specification & drawing for SI No.8080 on ser page No.156 in SSR-2010 (Pt-II) all as specified.
Supply and fix stainless steel butt hinges of size 100mm, complete all as specified and directed.
S&F 100 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 100 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 150 mm long aluminium extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet,cast or extruded section and fixing bolt of extruded section or cast aluminium alloy complete all as specified and directed.
S&F hold fasts etc and similar small articles made out of mild steel Flat etc of grade Fe-290 Gde - E-165 etc complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of surfaces of wood and wood based materials/steel and iron work new or old and treating ends of posts, back of chowkat etc with tar black paint area tarred exc 0.10 sqm but not exc 0.50 sqm each etc complete all as specified and directed.
All as per item No. 111.00 above but treating small articles such as stopper, covers, hold fast etc area not exc 0.10 Sqm each etc complete all as specified and directed.
Demolition of brickwork built in cement mortar including disposal of debris, etc outside MD land complete all as specified and directed.
M&L for brick work with sub class B old size bricks and of class designation 35, straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
S&F aluminium anodised Grills of approved design for window / ventilators and fixing with F/U channel including drilling as required in RCC sections in rectangular or architectual type balcony opening in existing building, complete all as specified and directed. Note: The Grills shall be of Model DG-102/DG-104 of Make Deco or equivalent make as approved by the GE.
Taking down existing aluminium grills from balcony/ any locations complete all as specified and directed.
Taking down existing aluminium joinery of any description (frame/ shutters) with all fittings (but excluding grills) complete all as specified and directed.
S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes, shall be measured and paid separately as supply only under respective item.
Supply only Stainless steel wire cloth.0.36 mm nominal dia of wireand average width of aperture 1.40mm and fixed with stainless steel wire staples in aluminium windows or along with 'F' section complete all as directed by EIC.
Disconnecting 1000 litres to 2000 liters capacity existing tanks, stacking safely for re-use ( or lowering if required) and hoisting, reconnecting and refixing in position including making connections etc, complete as specified and directed.
M & L for RCC M-30 (design mix) in aggregate in slabs supported on walls beams and columns in floors ,roofs, landings, balconies, canopies, desk slabsand in shelves and the like complete all as specified and directed.
M & L for formwork to soffits of suspended slabs such s slabs, floor slabs, landings and similar work : not exceeding 200 mm thick complete all as specified and directed.
Mild steel deformed/TMT bars 10 mm dia, cut to length, bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with mild steel wire, annealed not less than 0.9 mm dia or securing with clips complete all as specified and as directed
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges
Providing and injecting chemical emulsion for post construction Anti-termite treatment along external wall using chemical emulsion @7.5 lit/Sqm of the vertical surfaces of the sub structure to a depth 350 mm all as specified.
Treatment of soil under existing floor using emulsion @ 1.00 liter per hole 300 mm apart including drilling holes with CM (1:2) to match with existing wall/floor, complete all as specified and directed.
S & F Vitreous China urinals, half stall type (back to corner wall type), complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F stainles steel sink with drainage board, One mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers including CI cantilever bracket, connecting union etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm including supply and fixing bib tap CP with long body screwed for iron pipe complete all as specified and directed. Make : Nirali, Bule star ISI marked.
S & F for framed brackets of angles or tees with web and flanges cut to shape , drilled and counte sunk for screw, incl bending and welding angles, as necessary , guset plates, riveting etc, n.exc 10 kg each brackets conforming to Fe. 290. Gde-E-165 (brackets over 10 kg each to be measured under 'strucutural steel complete all as psecified and directed.
S & F for pre -laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
Taking down copper/ aluminum point wiring (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc.
Taking down of Old MCCB, MCB DB Metal clad sockets with MCB of any rating. Complete all as directed.
M & L for point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm (02 run, one for phase and other for neutral), PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn in and including PVC casing caping (minimum 25mm width) fixed on the surfaces with all accessories, fittings, PVC junction boxes etc, sunk pressed steel boxes not less than 2 mm thick, 50 mm deep terminal boxes covered with 3mm thick plastic laminated sheet top cover fastended with chromium plated brass screws, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light / fan / bell point controlled by one switch
All as per item No 134 but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches.
All as per item No 134 but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board.
All as per item No. 134 above but wiring complete with 2.5 Sqmm for 3 pin 15 A socket multipurpose on independent board
Supply & Fix switch piano single pole 5 Amps, 240 Volt, one way
Supply & Fix switch socket combination 2 in 1 , 5 Amps multipurpose flush type.
Supply & Fix switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal.
Supply & Fix Ceiling rose surface bakelite three terminal, 240 V.
Supply & Fix electronic regulator Step type 2 module type 240V suitable for ceiling fan.
S&F in repairs Surface, hanging and wall mounted batten suitable for LED tube 20/22 watts, 230 volts alongwith tube rod 22 watt (double side connection), including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core PVC insulated copper conductor cable including fixing arrangements complete all as directed. Make : Havells /Crompton/Bajaj
Taking down ceiling fan/exhaust fan, sealing cable end dismantling blades and removing fan and blaes and keeping in safe custody for refixing at site.
M & L for spray Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
M & L for Hanging of ceiling fan including provision of cable from ceiling rose or connector to fan complete.
S & F MCB DB 12 way SPN, double door, vertical type, IP - 43 with 200 Amps rated bus bar, AC and connecting up complete all as specified.
S&F sheet metal enclosure TP&N MCCB DB 4 way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 with provision of MCCB 63 Amps (as incomer), fixed properly on / in concealed/surface position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires all as directed.
S & F MCB SP 6 to 32 Amps, 240 Volts, 50 Hz, 'B' series,10 KA Breaking capacity complete.
S & F MCB SPN 40-63 Amps, 240 Volts, 50 Hz, 'C' series, 10 KA Breaking capacity complete.
M&L for MCB TPN 32 Amps, 415 Volt, 50 Hz, 'C' series, 10 KA Breaking capacity complete.
Supply & Fix Single Pole & neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 16 Amps complete.
Supply & fix triple pole & earth enclosure with a three pin & earth plug with socket complete with one triple pole MCB 32 Amps complete.
Supply & lay XLPE insulated 4 Core 4 Sqmm PVC insulated FRLS multistranded copper conductor armoured cable 660/1100 volts grade including saddles & spacers for clamping the cables along the wall etc complete including taking down old unserviceable cable. Make - Havells/Polycab/Finolex/Plaza/KEI
Supply & lay XLPE insulated 2 Core 4 Sqmm PVC insulated FRLS multistranded copper conductor armoured cable 660/1100 volts grade including saddles & spacers for clamping the cables along the wall etc complete including taking down old unserviceable cable. Make - Havells/Polycab/Finolex/Plaza/KEI
Supply & lay XLPE insulated 2 Core 2.5 Sqmm PVC insulated FRLS multistranded copper conductor armoured cable 660/1100 volts grade including saddles & spacers for clamping the cables along the wall etc complete including taking down old unserviceable cable. Make - Havells/Polycab/Finolex/Plaza/KEI
M & L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers all as shown in Electrical Plate No.3 of SSR Part- I connected to earthing test point all as specified or indicated including testing on completion.
M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 4.25 M deep below normal GL) with top edge of the plate not less than 3.5M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.
S&F GI strip size 25 x 4 mm all as directed including welding brazing and taking down of old copper strips as required at site
Supply & fix in repairs UPVC panel trunking of size 100 mm X 100 mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision / Presto Plast/Finolex
Supply & fix in repairs UPVC panel trunking of size 25 mm X 25mm including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed Make - Precision /Presto Plast/Finolex
Vishal Builders
M/s Mohd Altaf Hanif Qureshi
Parmatma Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .