Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹32.7 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹34.9 L+₹2.2 L (6.74%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹35.2 L+₹2.5 L (7.63%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹36.4 L+₹3.7 L (11.4%)Admitted-Finance | L4 | Admitted-Finance | ||
| 5 | L5₹41.4 L+₹8.7 L (26.7%)Admitted-Finance | L5 | Admitted-Finance |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
23 Feb 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER PHED RURAL DN BHILWARA
bhilwara
kunwar ka badiya
2026_PHCJA_536328_2
NIT NO 155-165/2025-26 EE PHED RURAL DN BHILWARA
Open Tender
Civil Works
Percentage
181 days
BHILWARA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
EXECUTIVE ENGINEER PHED RURAL DN BHILWARA
₹84,000
Yes
12 Mar 2026
7 Feb 2026
23 Feb 2026
7 Feb 2026
23 Feb 2026
7 Feb 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: -conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.
b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.
c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.
d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall.
e) Successfully hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab.
g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container.
i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab. | - | - | - | - |
| 2 | Rates for RCC OHSR,SBC 7 T/sqm, SEISMIC ZONE-II & STAGING 15 M | - | - | - | - |
| 3 | 75 KL capacity | 75,000 | kg | 34.38 | ₹25,78,500 |
| 4 | Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. | - | - | - | - |
| 5 | 100 mm | 80 | Mtr | 2,259 | ₹1,80,720 |
| 6 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .
Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
Supply may be in coil or straight length in 6 M/12 M. | - | - | - | - |
| 7 | HDPE PE-80 PN-10 | - | - | - | - |
| 8 | 110 mm dia | 1,100 | RMT | 675 | ₹7,42,500 |
| 9 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: | - | - | - | - |
| 10 | All kinds of soil | 363 | CUM | 200 | ₹72,600 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_955415.xls
BOQ • 0.29 MB
156.pdf
Tender Documents • 18.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .