| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC 581 PHASE I RAM DARBAR CHANDIGARH | ₹18.5 L Quoted ₹11.4 L | L1 | Accepted-AOC agency found L1 |
| 2 | L2₹12.4 L+₹99,639.43 (8.75%)Rejected-Finance 1627 SECTOR 26 PANCHKULA | ₹12.4 L+₹99,639.43 (8.75%) | L2 | Rejected-Finance Agency not found L1 |
| 3 | L3₹12.5 L+₹1.1 L (9.49%)Rejected-Finance M S A K ENTERPRISES C P DIVISION NO 6 SECTOR 9 D U T CHANDIGARH B 12 2723 ADARSH NAGAR NAYA GAON MOHALI PUNJAB | CHANDIGARH | CHANDIGARH | 160001 | ₹12.5 L+₹1.1 L (9.49%) | L3 | Rejected-Finance Agency not found L1 |
| 4 | L4₹13.6 L+₹2.2 L (19.2%)Rejected-Finance 105 B MOTIA CITI ZIRAKPUR 140603 | S A S NAGAR | PUNJAB | 140603 | ₹13.6 L+₹2.2 L (19.2%) | L4 | Rejected-Finance Agency not found L1 |
| 5 | L5₹13.7 L+₹2.3 L (20.0%)Rejected-Finance 621 A KAJHERI SECTOR 52 CHANDIGARH | ₹13.7 L+₹2.3 L (20.0%) | L5 | Rejected-Finance Agency not found L1 |
Tender Value
₹18.5 L
EMD Value
₹36,972
Closing Date
24 Jul 2026, 2:00 pmClosed
Executive Engineer C P Division No 5 Chandigarh
Executive Engineer C P Division No 5, Deluxe Building Ground floor Sector 9 D Chandigarh
Facia Repair and Pointing on Brick Work on Boundary Wall in Civil Hospital, Sector 45, Chandigarh.
2026_CHD_94104_1
EECP5/2026/2962767 dated 17.07.2026
Open Tender
Civil Works
Percentage
90 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹36,972
8 Sept 2026
17 Jul 2026
24 Jul 2026
17 Jul 2026
24 Jul 2026
17 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 112 mm cement plaster of mix DSR 13.1 | |||||
| 1.01 | :1:6 (1 cement: 6 fine sand) DSR 13.1.2 | 828.89 | sqm | 324.34 | ₹2,68,842.18 |
| 2Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: N DSR 13.47 | |||||
| 2.01 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ .90 kg/10 sqm) DSR 13.47.1 | 1,607.58 | sqm | 166.48 | ₹2,67,629.92 |
| 3Finishing walls with Acrylic Smooth exterior paint of required shade DSR 13.111 | |||||
| 3.01 | Old work (One or more coat applied @ 0.90 ltr/10 sqm). DSR 13.111.2 | 1,637.68 | sqm | 78.47 | ₹1,28,508.75 |
| 4 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done DSR 14.72 | 929.02 | sqm | 329.11 | ₹3,05,749.77 |
| 5 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead DSR 15.56 | 828.89 | sqm | 53.17 | ₹44,072.08 |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved DSR 15.60 | 12.43 | CUM | 256.82 | ₹3,192.27 |
| 7 | Repair of detiorarted RCC Surface having exposed rusted reinforcement consisting of following operation a) Chipping of concrete surfaced 25mm thick average depth afterwards removal of loose concrete and exposing the steel bars. Cleaning the surface properly to remove dust particles and rust from the steel bars. Complete in all respect ot the entire satisfaction of Engineer-in-charge. b) Moistening the surface properly and applying arcylic polymer (acrocrete/pidilite/master crete) coating mixing with cement for proper bonding of old and new concrete in two coats @ 0.20 kg Polymer per 1 Kg cement c)providing and fixing MS wire mesh by using binding wire and nails. Complete as per directions and approval of Engineer-incharge. d) Placing of cement concrete 1:1.5:3 having thicknesss (3/4" to 1.1/4") mixed with acrylic polymer admixture @ 1 kg per bag of cement . Complete in all respect to the entire satisfaction of engineer-in-charge. NS | 742.47 | sqm | 756.19 | ₹5,61,448.39 |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.47 MB
BOQ_115372.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .