| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC 12 138 MANAS NAGAR BARA REWA POST OFFICE BANSAGAR COLONY REWA | REWA | REWA | MADHYA PRADESH | 486001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹36.4 L+₹5.6 L (18.2%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹37.1 L+₹6.4 L (20.7%)Rejected-Finance T 16 1 SHETTY HOTEL OLD NAVY NAGAR COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹37.3 L+₹6.5 L (21.2%)Rejected-Finance 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹47.0 L+₹16.3 L (52.9%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
6 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NAVY NAGAR COLABA MUMBAI
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINTENANCE OF MAIN RISING OF HIGH LOW RISE BUILDINGS AND ASSOCIATED WORKS AT RS AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2024_MES_652771_1
8374/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹98,000
Yes
12 Jul 2024
7 May 2024
8 Jun 2024
7 May 2024
6 Jun 2024
24 May 2024
7 May 2024 - 30 May 2024
Amount
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/ loose soil complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified. Note : For item No 1.00 and 2.00 above rate deemed to be included for earth work and form work required as per site requirement & as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removing debris out side MD land all as specified.
M&L cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in support of CI pipes, foundation and hardstanding finishing even and fair without using extra cement all as specified.
Removing excavated material outside MD land all as specified and directed.
Supply/ Fixing in repair/replacement of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note (1)Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece of full length. (2) Rate of scafolding in high rises building up to 15th floor and terrece including clipping of GI pipe shall be included in quoted rates
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and laying in replacement of spigot and socket ductile iron water tubing,class K-9, cement mortar lining on inner surface and one coat of bituminous paint over exposed surface ISI marked, IS No. 8329: 2000, including rubber joint of suitable size laid on roof/floor/trenches with proper alignment as per site requirement and carryout testing against leakage before filling the trenches etc complete all as specified and directed.
300 mm bore.
200 mm bore.
150 mm bore.
100 mm bore.
Taking up/down of existing Motor Actuated ball Valve of following size from existing line and refixing the same after cleaning/ servicing on the new pipe line and where directed including wiring/termination all as specified and directed.
150 mm bore
100 mm dia
50 mm dia
80 mm dia
S& F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, welding of size Fe 410-W(GdeE- 250) quality A incl dismantling old one complete all as specified and directed by Engineer-in-Charge.
M & L for DI specials confirming to IS - 9523, spigot /socket or flanged fitting I.e. bend, tee, collar, flanged/ socket /spigot, Tappers and tails pieces etc suitable for 100 /150/200/300 mm bore pipes (joints and joining material shall be measured and paid seperately)
Dismantling old valve pit chamber and construction of valve chamber of size 1.2 x 1.2 x 1.2m (internal dimension) (above GL 0.30 mtr) , 15cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hardcore of broken stone, 23cm thick brick walls built in cement and sand mortar 1:4, 15mm thick internal and external plaster including top of floor in cement and sand mortar 1:3, 15mm thick, finished even and smooth, without using extra cement, 5 mm thick plate cover over complete chamber on 50mm x 50mm x 6mm MS angle frame embeded in PCC 1:2:4 type B-1coping, having rectangular, hinged, opening of size 150 x 100mm with locking arrangements, hold fasts, etc, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of debris outside MD land complete all as specified. Note :- Rates for removing of old plasters, broken stones/bricks, PCC of any type, earth work, new M S Chanel and MS Plate including nut, bolt, washers, welding e.t.c are deemed to be inclueded in the quoted rated.
M & L for Cutting existing DI pipes and reducing for insertion of DI fittings to required length in position for following sizes :-
300 mm bore.
200 mm bore.
150 mm bore.
100 mm bore.
S&F sluice valves flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class PN 1.6, confirming to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers including taking down old unserbiceable complete including pumping out accumulated water all as specified and directed by Engr-in-Charge of following size.
300 mm bore
250 mm bore
200 mm bore
150 mm bore
100 mm bore
S&F in repair Rotational moulded multylayer ( minimum three layer) polyethylene water storage tank confirming to IS12701(1996) hoisting and fixing in position at any location removing existing distmantling RCC/PCC OHT and including making new foundation as well as disconnecting all incoming & out going connection, provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection complete all as specified and directed.
5000 Ltr capacity
2000 Ltr capacity
Supply and fix in repair CI foot valve threaded type or flanged type or swing and lift type confirming to IS 4038 (1986) in existing location or new position or location in the sump of any capacity including making of flanged joints, nut bolts washers rubber gasket welding work etc and repair making good distrubed surface to match existing PCC surface of following sizes :-
300 mm bore
250 mm bore
200 mm bore
150 mm bore
80 mm bore
Supply and fix in repair of CI Non return valve confirming to IS 5312-1/2 (2004) PN 16 including nut, bolts, washer, flanges, gaskets, wleding works etc of the following sizes :-
300 mm dia
250 mm dia
200 mm dia
150 mm dia
100 mm bore
Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :-
40 mm bore
50 mm bore
80 mm bore
S& F in repair 3-layer PP-R Polypropylene random copolymer) pipes of following sizes SDR 11 UVstablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R plain & brass threaded polypropylene random fittings laid in trenches, on walls, ceillings, floors, or use as riger on G+14 bldgs etc. Note: Rates are deemed to include the following:- (a) All safety measures shall be taken by the worker/plumber while carrying out the work at G+14 bldgs . (b) Making of scaffolding.
S& F in repair 3-layer PP-R Polypropylene random copolymer) gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :- etc.
Supply and fix in repairs PTMT bib tap with crutch or Duro or butterfly handle screwed both ends suitable for GI tubing/CPVC pipe 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles complete all as specified and directed by Engr-in-Charge.
Supply, Installation Testing & Commissioning in repair of Motor Actuated ball Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 150 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Direct/indirect on valve
Supply, Installation Testing & Commissioning in repair of Motor Actuated ball Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 100 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Direct/indirect on valve
Supply, Installation Testing & Commissioning in repair of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 80 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Direct/indirect on valve
Dismantling of existing connection and taking out pressure reducing valve of size 25 mm bore cleaning servicing and refixing at existing location in high rise buildings (G+14) including provision of fittings, I.e. union, elbow, bend, nipple, etc. complete to make the line functional all as specified:- (a) All safety measures shall be taken by the worker/plumber while carrying out the work. (b) Rate of scaffolding shall be included in the quoted rate.
Taking down GI tubing fixed to wall at location cleaning and refixing the same with clamping on wall including provision of necessary fitting in high rise building (G+14 stories) for the following:- (a) All safety measures shall be taken by the worker/plumber while carrying out the work. (b) Rate of scaffolding shall be included in the quoted rate.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
Supply and laying in repair/ replacement of CPVC pipes 20 mm nominal bore SDR 11 & Plain CPVC SDR 11 fittings such as nipple, union, socket, elbow, bends, tee, adopter e.t.c fixed to wall/floors/ceiling including work to be done up to 15 th floor in high rise buildings and low rise buildings in short piece/length all as specified and directed by Engineer-in-charge.
M & L for calibration and testing of Ultra sonic water flow meter of size 450mm dia from NABL accredited independent testing lab approved/recommended by BMC at site including manually opening of flow meter pit chamber cover, cleaning of chamber & pipe by rubbibg and brushing making arrangement of fixing testing chain under pipe etc complete all as specified and directed by Engr-in-Charge. Note: The test report should be submitted to the Engr-in-Charge within 6 working days from the date of testing.
SHRI SAI ENTERPRISES
Shetty Construction Co
Unity Enterprises
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .