Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.3 L+₹35,878.50 (6.05%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹6.6 L+₹64,598.75 (10.9%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | - | Rejected-Technical Not enlisted in appropriate category i.e. c (i). |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN-151201
AS PER BOQ/PRICE SCHEDULE
2022_MES_529810_1
GE/BHI/T-57/2022-23
Open Tender
Civil Works
Item Rate
90 days
GE (AF) BHISIANA
AS PER NIT/ TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE (AF) BHISIANA
₹12,000
Yes
12 Aug 2022
9 Jun 2022
21 Jul 2022
9 Jun 2022
19 Jul 2022
25 Jun 2022
15 Jun 2022 - 23 Jun 2022
Amount
S&F Sub-main Wiring (Surface/ Concealed) with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in medium grade PVC CONDUIT/PVC CASING & CAPING, complete all as specified and as directed. Note: (a) 3 Runs of 4 sqmm Copper Wire & 1 Runs of PVC conduit shall be measured as single unit. (b) The disturbed surface of wall for surface box wiring shall be make good by applying cement plaster, putty and colour wash etc to match with the existing surfaces. (c)The quoted unit rate shall include Cuting chases for conduits and sinking's for boxes.
Supply and install invertor based split AC with cordless remote of capacity 1.5 TON (Copper coil Both in door & out door Unit) electric driven single phase, 230 volts, New 5 star rating including all accessories like brackets, rubber tubing, copper tubing as required at site, gas charging, with auto filter clean technology etc including testing and commission with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as directed. Note : (a) All cooling /condensing coil should be copper material. (b) Brackets shall be measured and paid seperately under appropriate item.
Supply and install invertor based split AC with cordless remote of capacity 2.0 TON (Copper coil Both in door & out door Unit) electric driven single phase, 230 volts, New 5 star rating including all accessories like brackets, rubber tubing, copper tubing as required at site, gas charging, with auto filter clean technology etc including testing and commission with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as directed. Note : (a) All cooling /condensing coil should be copper material. (b) Brackets shall be measured and paid seperately under appropriate item.
Supply and install Voltage stablizer copper winding automatic digital type operation single phase naturally air cooled indoor type & designed for input variation between 140 Volts to 280 Volts with output voltage stablized at 230 Volt with accuracy of (+/-) 2.5 percent of capacity 5 KVA.
Supply and install Voltage stablizer copper winding automatic digital type operation single phase naturally air cooled indoor type & designed for input variation between 140 Volts to 280 Volts with output voltage stablized at 230 Volt with accuracy of (+/-) 2.5 percent of capacity 4 KVA.
S&F Flame Proof, Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 25 Amp, 415 Volt, TPN, 2 Pin and Earth Plug, Fully interlocked suitable for installation in hazardous as per IS-2147/ 62 Alluminium alloy/Cast Iron Neoprene Gasket Degree of Protection IP 65 and Certified from BIS with ISI marked , complete all as specified and as directed.
S&F Power unit for 25 amp 1.5 to 2 ton AC modular type, 4 module, 240 volts all as specified and as directed by Eng-in-Charge. Make : Legrand Cat No 6755 58 or Equivalent in anchor Roma/ Crabtree.
Supply and fix PVC rigid conduit pipe ISI Mark 25mm dia including all accessories and necessary saddles with fixing screws, gutties etc. for drain out water all as specified and directed by Eng-in-Charge. Note: The quoted unit rate shall include Cuting chases for conduits and sinking's for boxes and making good to walls, floors etc.
Supply and fix split AC Stand for outdoor unit suitable for 1.5/2 ton including necessary fixing arrangement. Such drilling holes in wall, anchoring in wall, nut, bolts etc all as specified and directed by Engr-in-Charge
S&F Sheeet metal enclosures for TPN DB's suitable to incorporated MCCB 63 Amp 4 Pole with double door (Glazed) for corporating MCBs, IP-43, 4 way with 200 amps rates busbar, 415 volts, as per IS-8623 all as specified and dircted.
S&F MCCB four pole 63 amps 'C' series, breaking capacity 16 Ka 'C' curve 415 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as directed by Engineer in Charge.
S&F MCCB four pole 40 amps 'C' series, breaking capacity 10 Ka 'C' curve 415 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as directed by Engineer in Charge.
S&F MCB SP, 20 Amps to 32 Amps, C Series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as directed by Engineer in Charge.
M & L for Earthing complete with galvanised steel plate electrode, 600 x 600 x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level ) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in para No 4 to the earthing test point all as specified and as directed. Note :- The cost of Excavation and Earth work PCC pit and Cl cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed including in the unit rate for earthing as as specified and as directed by Engr-in-Charge
S&F LCD Digital type AC timer for cyclic operation of 02 any type of Air Conditioner with displaying AC 1/AC2 on indication & 1 to 24 hours programmable to take load upto 2 Ton window/split AC with auto/manual facility at site all as specified & directed.
Supply & Fixing/Laying XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross sectional area 50 Sqmm 3½ Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified as and directed. Note: Earth work shall be measured and paid seperately under appropriate items,
Supply & Fixing/Laying XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross sectional area 25 Sqmm 3½ Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified as and directed. Note: Earth work shall be measured and paid seperately under appropriate item.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for Foundation etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm thick in Soft/Loose Soil, complete all as specified and as directed.
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply and laying reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40 mm all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including non Rigid PVC concealed Conduit except beam,column and RCC roof and chases cutting including suitable for modular switch and socket (Sunken box) incl MS sheet pressed terminal box (recessed) with modular couver plate for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
Supply and fixing LED light fitting 2x16Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engineer in Charge
S&F Switch Flame Proof Rotary type with Termination Box in LM6, 16 Amp, Single Pole, 250 Volt , complete all as specified and as directed.
M/s Vee Kay Associates
M/s Luxmi Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .