GE 861 EWS
GE 861 EWS C/O 56 APO
REPAIR TO DRAINS, PCC PATH, FENCING, HARD STANDING, PERIODICAL SERVICES AND OTHER MISC WORKS AT KHUNMOH GRN UNDER GE 861 EWS.
2020_MES_378555_1
GE 861 EWS-50/2020-21
Open Tender
Civil Works
Item Rate
180 days
UNDER GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹70,000
Yes
28 Oct 2020
18 Sept 2020
15 Oct 2020
18 Sept 2020
13 Oct 2020
1 Oct 2020
Amount
Demolition of cement concrete (unreinforced) in ground floors & pavings n.exc 15 cm thickness (below or above ground level), complete all as specified and directed
Demolition of brick work or stone / boulder masonry, built in cement mortar, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed
Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Dismantling plain or corrugated steel sheeting , any gauge and thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc. 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m, in hard/dense soil and making good surfaces, complete all as specified and directed
M&L PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
M&L cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed.
M&L mild steel work in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed
S&F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as directed. Note : (each line of wire to be measured)
S&F Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
M&L preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M&L 150mm PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as in flooring over sub base finished even and fair without using extra cement, laid in alternate bays including necessary formwork, complete all as specified and directed
M&L forming of 20mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade 'A' in 150mm thick flooring, complete all as specified and directed.
M & L for forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A', complete all as specified and directed.
M&L 100mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in sub base of floor, complete all as specified and directed.
M&L 75mm thick, PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of floor, complete all as specified.
M & L Machine pressed precast concrete interlocking paver block laid in floor , any shape and size conforming to IS-15658-2006 of 100mm thickness M-50 grade with grey cement & pigment, laid over and including 50mm thick sand cushion and compacted with mechanical vibrator complete all as specified and directed.
M&L chequered cement concrete tiles of size 300 x 300 x 25 mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M & L Machine pressed precast concrete interlocking paver block laid in floor , any shape and size conforming to IS-15658-2006 of 60mm thickness M-35 grade with grey cement & pigment, laid over and including 50mm thick sand cushion and compacted with mechanical vibrator complete all as specified and directed.
M & L Machine pressed precast concrete interlocking paver block laid in floor , any shape and size conforming to IS-15658-2006 of 80mm thickness M-40 grade with grey cement & pigment, laid over and including 50mm thick sand cushion and compacted with mechanical vibrator complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
M&L walling of random rubble masonry with best quality stone, uncoursed, well bonded, bedded and solidly hearted and built in CM 1:4, all as specified.
All as per the description of item No 23 here-in- before but but except stones.
M&L Plain cement concrete M-10, 1:3:6, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in soft/loose of soil, complete all as specified and directed.
Taking down cement plaster on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M &L rendering 15mm thick on brick or concrete surfaces in CM 1:4 finished even and smooth without using extra cement including mixing of water proofing compound in the proportion as mentioned in manufacture's instructions complete all as specified. Note: Water proofing compound shall be measured and paid for separately.
M&L Rendering 10 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L peparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of alkali-resistant priming paint, complete all as specified and directed
M&L preparation of old plastered/unplastered wall surfaces and applying two coats of cement base paint including complete removal of existing treatment, complete all as specifed. and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n. exc 20mm for lime or sand stone & dressing of face beds & joints as specified, of random random rubble walling, uncoursed or brought upto courses, complete all as specified and as directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:4 complete all as specified and as directed.
All as per the description of item No 33 here-in- before but except bricks, complete all as specified and directed.
M&L Flush pointing to random rubble masonry, uncoursed or brought upto courses in CM 1:3, complete all as specified and directed.
Supply only Integral water proofing compound of approved quality, complete all as specified and directed
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in surface channel and drains, complete all as specified and directed
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed
M & L for 40mm thick ,plain cement concrete, 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in floors finished even and smooth without using extra cement, complete all as specified and directed.
Supply only, glass diving strips 38mm wide 3mm thick laid as in desired design, complete all as specified and directed.
Preparation to old plastered/unplastered wall surfaces incl brooming down or steel wire brushing , scraping down, smooke soot, moulds, moss & efflorescent salts and trading oil and greasy spots etc and applying one coat of white wash, complete all as specified and directed.
All as per the description of item No 43 here-in- before but as on ceiling, complete all as specified and directed.
Preparation to old plastered/unplastered wall surfaces including cornices by brooming down or steel wire brushing , scraping down, smooke soot, moulds, moss & efflorescent salts and trading oil and greasy spots etc and applying one coat of colour wash, complete all as specified and directed.
Preparation to old plastered/unplastered wall surfaces including cornices by brooming down or steel wire brushing , scraping down, smooke soot, moulds, moss & efflorescent salts and trading oil and greasy spots etc and applying one coat of distemper oil emulsion, complete all as specified and directed.
Complete removal of existing treatment of walls and preparing the surface to receive 3mm thick wall care putty and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
Preparation to old plastered/unplastered wall surfaces including cornices by brooming down or steel wire brushing , scraping down, smooke soot, moulds, moss & efflorescent salts and trading oil and greasy spots etc and applying one coat of cement base paint, complete all as specified and directed.
Preparation to old plastered/unplastered wall surfaces including cornices by brooming down or steel wire brushing , scraping down, smoke soot, moulds, moss & efflorescent salts and trading oil and greasy spots etc and applying two coats of cement base paint, complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of weather coat exterior emulsion paint over a coat of primer, complete all as specified and directed.
Preparation of old painted wooden surcaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified.
Preparation of old painted steel surcaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in patches not exceeding 3.00 Sqm each patch on brick or concrete surfaces of ceiling in CM 1:3 finished the surface even and smooth without using extra cement, complete all as specified and directed.
Preapration of new plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of primer, complete all as specified and directed.
Preapration of new plastered or unplastered surfaces of wall to receive 3mm thick wall care putty and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash,complete all as specified and directed.
M&L Obliterating old writing of any description, n exc 0.1 sq. m, with paint to match existing work, complete all as specified and directed .
M&L Writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high, complete all as specified and directed.
M&L Stops, commas, short lines, dashes, hyphens, brackets, etc., complete all as specified and directed. (NOTE for Srl item No 48 to 61: The cost of scaffolding for safety precaution required for works in height shall be deemed to be including while quoting rates by Contractor.)
M/S ZEA CONSTRUCTIONS
M/S LATIF AHMAD BABA CONSTRUCTION
M/S ABDUL HAMID RATHER
M/S U.K. ENTERPRISES
M/S AK ENTERPRISES
M/S Haji Mohammad Sultan Sofi
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .