Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.9 L+₹4.8 L (28.1%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L2 | Rejected-Finance Rejected being other than L1 | |
| 3 | L3₹21.9 L+₹4.9 L (28.5%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than L1 | |
| 4 | L4₹22.4 L+₹5.3 L (31.1%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L4 | Rejected-Finance Rejected being other than L1 | |
| 5 | L5₹22.4 L+₹5.4 L (31.4%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
1 Jun 2021, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR MAINT OF MAIN DBs SERVICE CONNECTION AND SUB MAIN WIRING AND REPAIR MAINT OF INT ELECT AND PETTY REPAIR WORKS AT TC LSA OFFRS MESS CONNECTING ACCESSORIES UNDER GE 865 EWS
2021_MES_441889_2
865/EWS(NIT-19)/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹80,000
Yes
20 Jun 2021
11 May 2021
3 Jun 2021
11 May 2021
1 Jun 2021
25 May 2021
Amount
Supply and fixing in replacement MCB distribution board double door, regal grey, sheet metal enclosure, SPN 240 volts 12 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc complete all as specified and directed. Make: Cat part No 5076 10 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Supply and fixing in replacement MCB distribution board double door, regal grey, sheet metal enclosure, SPN 240 volts 8 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc complete all as specified and directed. Make: Cat part No 5076 11 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Supply and fixing MCB distribution board Double door, sheet metal box, SPN, Regal Gray, 4 Way 240Volt 50Hz with complete accessories, concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc incl taking down old DBs complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 5076 10 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
S & F in replacement sheet metal enclosures 'A' frame panel board (MCCB distribution board when MCCBs to be used 4 way 415 Volt,double door with neutral link earth bar, din rail , necessary blanking plates, including provision for one incomer MCCB upto 250 Amps and MCBs SP/SPN fixing DB flushed in wall complete all as specified and directed . Make: Cat part No. DHDLVDRWAOF004 of HAVELLs or equivalent of Legrand/ABB/L&T/Schneider Note : MCCB/MCB and acceossories will be measured and paid seperately.
S&F replacement of sheet metal enclosures with socket plug top and single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amps 240volt. Make : Havells/HPL/Legrand/ABB/L&T/Schneider
S & Fin replacement factory made epoxy powder coated Distribution Board double door TP & N 4 ways (TPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standrad DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with suitable for one MCB T.P.N, 415 V, 63/40 Amps, 10 KA as incomer and 12 SP MCBs / 3TPN MCBs outgoings complete all as specified and conforming to IS : 8623. complete all as specified and directed . Make : Legrand Cat No. 6077 15 or equivalent model of Havells/C&S/L&T/Schneider/ABB/Siemens
Sub main wiring with four runs of 16 Sqmm (4x16 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC conduit of suitable dia, ISI marked with all accessories etc with two run of 10 Sqmm (2x10 sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 4 runs of 16Sqmm (4x16sqmm), two run of 10 Sqmm (2x10 sqmm) cable and one metre of PVC conduit will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB Make of Conduit : PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
Sub main wiring with four runs of 10 Sqmm (4x10 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC conduit of suitable dia, ISI marked with all accessories etc with two run of 6 Sqmm (2x6 sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 4 runs of 10 Sqmm (4x10 sqmm), two run of 6 Sqmm (2x6 sqmm) cable and one metre of PVC Conduit caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB Make of Conduit : PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
Sub main wiring with four runs of 6 Sqmm (4x6 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC conduit of suitable dia, ISI marked with all accessories etc with two run of 6 Sqmm (2x6 sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 4 runs of 6 Sqmm (4x6 sqmm), two run of 6 Sqmm (2x6 sqmm) cable and one metre of PVC Conduit caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB Make of Conduit : PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
Sub main wiring with two runs of 10 Sqmm (2x10 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6 Sqmm (1x6 sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 10 Sqmm (2x10 sqmm), one run of 6 Sqmm (1x6 sqmm) cable and one metre of PVC Conduit caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB Make of Conduit : PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
Sub main wiring with two runs of 6 Sqmm (2x6 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6 Sqmm (1x6 sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6 Sqmm (2x6 sqmm), one run of 6 Sqmm (1x6 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB Make of Conduit : PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
Sub main wiring with two runs of 4 Sqmm (2x4 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 4 Sqmm (1x4 sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down of old sub main wirings complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 4 Sqmm (2x4 sqmm), one run of 4 Sqmm (1x4 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB Make of Conduit : PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
S&F in replacement MCB 'C' series triple pole and neutral (TPN) 100Amps 415Volt all as specified and directed. Make : Cat part No. DHMJCTPF100 of Havells or equivalent of ABB/ Legrand/L&T
S&F in replacement MCB 'C' series triple pole and neutral (TPN) 63Amps 415Volt all as specified and directed. Make Cat part No. DHMGCTPF063 of Havells or equivalent ABB/ Legrand/L&T
S&F in replacement MCB 'C' series triple pole (TP) 40 Amps 415Volt all as specified and directed. Make : Cat part No. DHMGCTPF040 of Havells or equivalent ABB/ Legrand/L&T
S&F in replacement MCB 'C' series Single pole and neutral (SPN) 63Amps 240 Volt all as specified and directed. Make : Cat part No. DHMGCSNF063 of Havells or equivalent ABB/ Legrand/L&T
S&F in replacement MCB 'C' series Single pole and neutral (SPN) 40Amps 240 Volt all as specified and directed. Make : Cat Part No. DHMGCSNF040 of Havells or equivalent Legrand/ ABB/L&T
S&F in replacement MCB 'C' series Single Pole 6 to 32 Amp 240 Volts all as specified and directed. Make : Cat part No. DHMGCSPF006-032 of Havells or equivalent Legrand/ ABB/L&T
S&F in replacment PVC flat twin core 16 sqmm aluminium cable complete all as specified and directed by Engr-in-Charge. Make : Havells/Finolex/Plaza/Polycab
S&F in replacment PVC flat twin core 10 sqmm aluminium cable complete all as specified and directed by Engr-in-Charge. Make : Havells/Finolex/Plaza/Polycab
S&F in replacment PVC flat twin core 6 sqmm aluminium cable complete all as specified and directed by Engr-in-Charge. Make : Havells/Finolex/Plaza/Polycab
Supply only flexible twin twisted copper wire two core of size 23/0.0076mm Make : Havells/Finolex/Plaza/Polycab
S&F in replacement for industrial busbar chambers 100 amps Capacity 4ways complete including taking down old u/s busbar chambers all as specified and directed by Engr-in-Charge. Make : Cat part No.IHBC010004 of Havells or equivalent of Indo Asian /Standard/HPL
S&F in replacement for industrial busbar chambers 200 amps Capacity 4ways complete including taking down old u/s busbar chambers all as specified and directed by Engr-in-Charge. Make : Cat part No. IHBC020004 of Havells or equivalent of Indo Asian /Standard/HPL
S&F in replacement for industrial busbar chambers 250 amps Capacity 4ways complete including taking down old u/s busbar chambers all as specified and directed by Engr-in-Charge. Make : Cat part No. IHBC025004 of Havells or equivalent of Indo Asian /Standard/HPL
S&F in replacement bollard light CONE - IP65 Cone series, 8 watts, acts as a imposing street furniture.The elegant yet minimalsitic design acts a silent observer and giving light, diffuser at the upper portion acts a beacon of path guidance in a landsacpe environment. Make. Havells Cat part No CONEBL8WLED857SSYMTOPC or equivalent of Phlips/Bajaj/C&S
S&F in replacement building security light ENDURA PEARL NEO New generation energy saving and environmental friendly long life LED street light 48 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. Make : Havells (ENDURAPEARLNEOSL48WLED757SASYTOPC) or equivalent of Phlips/Bajaj/C&S
S&F in replacement building security light ENDURA PEARL NEO New generation energy saving and environmental friendly long life LED street light60 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. Make : Havells (ENDURAPEARLPLUSSL60WLED757SASYTOPC) or equivalent of Phlips/Bajaj/C&S
Supply, Fixing, connecting and testing and Commissioning of Factory made out door LT Panel with digital Timer switch 24 Hour setting cubical type Pole / floor mounted totally enclosed 2 Frame made out of 3.00 mm thick CRCA powder coated sheet and angle iron base frame of height 2' comprising of 65 Amp contactor ,TPN 63 Amp with digital type timer switch internaly pre wired suitable for 3 Ph power supply complete all as specified and directed. Make- HAVELLS Cat part No IHXTS09120 or L&T / SIEMENS/ABB/ Schneider
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in hard/dense soil and getting out soil, complete all as specified and as directed by Engineer-in-charge.
M&L for sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, including punning upto total 18 cm thick complete all as specified in clause 19.75 of SSR Par-I, complete all as specified. Note : Only punned thickness of 18 cm will be measured and paid.
Supplying and laying factory made, machine pressed un-reinforced precast concrete cable cover, Class LV, Type-I, flat, size 300mmx180mmx40mm, complete all as specified and directed.
S&L galvanized iron tubing 'light grade' 40 mm bore, with all fittings, laid in trenches or under road crossing as protection pipe, or fixed alongwith walls/poles with clamps including bolts, nuts & washers, including taking down old UG cable complete all as specified and directed. Make : Jindal/TATA/BST/Prakash Surya
S&L galvanized iron tubing 'light grade' 50 mm bore, with all fittings, laid in trenches or under road crossing as protection pipe, or fixed alongwith walls/poles with clamps including bolts, nuts & washers, including taking down old steel tubing and connections complete all as specified and directed. Make : Jindal/TATA/BST/Prakash Surya
Returning, filling in. including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in hard/dense soil complete all as specified.
Removing excavated surplus materials (soil) to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Supply and laying cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with standed aluminium conductor of following sizes 10 sqmm 2 Core laid in trenches or passing through pipe, ducts or fixed to wall/poles including taking down old cable complete all as specified and directed. Make : Cable corporation of India/Havells India Ltd/Universal Cables Ltd/ Polycab/RPG Cables/Gloster/KEI
Supply and laying cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with standed aluminium conductor of following sizes 10 sqmm 4 Core laid in trenches or passing through pipe, ducts or fixed to wall/poles including taking down old cable complete all as specified and directed. Make : Cable corporation of India/Havells India Ltd/Universal Cables Ltd/ Polycab/RPG Cables/Gloster/KEI
Supply and laying cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with standed aluminium conductor of following sizes 16 sqmm 4 Core laid in trenches or passing through pipe, ducts or fixed to wall/poles including taking down old cable complete all as specified and directed. Make : Cable corporation of India/Havells India Ltd/Universal Cables Ltd/ Polycab/RPG Cables/Gloster/KEI
Supply and laying cable XLPE Insulated screened PVC bedded galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with standed aluminium conductor of following sizes 25 sqmm 4 Core laid in trenches or passing through pipe, ducts or fixed to wall/poles including taking down old cable complete all as specified and directed. Make : Cable corporation of India/Havells India Ltd/Universal Cables Ltd/ Polycab/RPG Cables/Gloster/KEI
Supply and fix in replacement of Euroload On load Change over with advance neutral, 415 Volt in sheet metal inclosure 4 Pole of capacity 125 Amps with connecting acessories complete all as specified and directed. Make : Havells cat part No : IHCNFE0125 or equivalent of HPL/C&S/Legrand/ABB/Schneider/Siemens
Supply and fix in replacement of Euroload On load Change over with advance neutral, 415 Volt in sheet metal inclosure 4 Pole of capacity 160 Amps with connecting acessories complete all as specified and directed. Make: Havells cat part No :IHCNFE0160 or equivalent of HPL/C&S/Legrand/ABB/Schneider/Siemens
Supply and fix in replacement of Euroload On load Change over with advance neutral, 415 Volt in sheet metal inclosure 4 Pole of capacity 200 Amps with connecting acessories complete all as specified and directed. Make : Havells cat part No : IHCNFE0200 or equivalent equivalent of HPL/C&S/Legrand/ABB/Schneider/Siemens
Supply and fix in replacement Loadline MCCB 160 Amp, 25 kA (Conforms to IS/IEC:60947-2) MCCB G Frame, Four pole, 415 volt with fixed Thermal & Fixed Magnetic setting | Ics = 50% of Icu Make : Havells Cat part No. IHLGHF0160 # or equivalent of HPL/C&S/Legrand/ABB/ Schneider/Siemens
Supply and fix in replacement Loadline MCCB 250 Amp, 35 kA (Conforms to IS/IEC:60947-2) MCCB G Frame, Four pole, 415 volt with fixed Thermal & Fixed Magnetic setting | Ics = 50% of Icu Make : Havells Cat Part No IHLFNF0250 # or equivalent of HPL/C&S/Legrand/ABB/ Schneider/ Siemens
Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point etc including taking down of old u/s earthing set complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order (iii) Item includes the cost of Charcoal and commercial salt
Horizon Construction Company
M.S Sharma Enterprises
R B TRADERS
M/S ADHISH ENGINEERS
SUMEET TRADING CORPORATION
S S BUILDERS
Mehar Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .