Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.8 CrAccepted-AOC | ₹11.8 Cr Quoted ₹12.0 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹12.2 CrRejected-AOC 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹12.2 Cr | 2 | Rejected-AOC Being not L1 |
| 3 | 3₹13.9 CrRejected-AOC | ₹13.9 Cr | 3 | Rejected-AOC Being not L1 |
| 4 | 4₹14.1 CrRejected-AOC | ₹14.1 Cr | 4 | Rejected-AOC Being not L1 |
| 5 | 5₹20.1 CrRejected-AOC | ₹20.1 Cr | 5 | Rejected-AOC Being not L1 |
Tender Value
₹11.6 Cr
EMD Value
₹9.1 L
Closing Date
22 Sept 2021, 6:00 pmClosed
CE R N D Secunderabad
CE R N D Opp JBS Picket Secunderabad
SPECIAL REPAIRS TO BALANCE PORTION OF PERIMETER SECURITY WALL AND CONSTRUCTION OF ADDITIONAL WATCH TOWERS AT PASHAN PUNE
2021_MES_470592_1
CERD/PSN/TOKEN/57 OF 2019-2020
Open Tender
Civil Works
540 days
Pashan Pune
As per NIT
7 documents required · 7 mandatory
₹3,000
GEI R N D Pashan, Pune
₹9.1 L
Yes
28 Oct 2021
25 Aug 2021
27 Sept 2021
25 Aug 2021
22 Sept 2021
8 Sept 2021
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of watch tower with RCC frame structure (G+2) complete all as shown on drawings and as specified.
Schedule 'A' Part - II (EXCAVATION, EARTHWORK AND SITE CLEARANCE) This Schedule (contains under mentioned Sl. item No. 2.01 to 2.14) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. the unit rates quoted against item No. 2.01 to 2.14 is deemed to be included execution of work either manually or by mechanical means.
Surface excavation not exceeding 30cm deep and averageging 15cm deep and getting out in hard/ dense soil, complete all as specified and directed.
Surface dressing n exc 15 cm deep and getting out hard/dense soil complete all as specified and directed.
Excavation over area exc 1.50 m and n exc 3.00 m deep and getting out soft/distegarated rock complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundations, cesspits, manholes and sewage lines, etc. or for laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft /loose soil, including trimming the sides and forming bottom surface to the required level / slope etc., complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and exceeding 1.5metre but not exceeding 3.0 metre in depth; for foundations, etc., or for shafts, wells, cesspits, manholes, pier holes, etc., not exceeding 10 sq m on plan and getting out in soft /loose soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundations, cesspits, manholes and sewage lines, etc. or for laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard / dense soil, including trimming the sides and forming bottom surface to the required level / slope etc., complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundations, etc.,or for shafts, wells, cesspits, manholes, pier holes, etc., or sewage lines, etc. or for laying of water pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock, including trimming the sides and forming bottom surface to the required level / slope etc., complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundations, etc.,or for shafts, wells, cesspits, manholes, pier holes, etc., or sewage lines, etc. or for laying of water pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard rock, including trimming the sides and forming bottom surface to the required level / slope etc., complete all as specified and directed.
Returning, filling in, in any type of soils, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removing surplus excavated material (soils) to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Removing surplus excavated material (soils) to a distance exceeding 50metre and not exceeding 250 metre, depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Removing surplus excavated material (soils) to a distance exceeding 250metre and not exceeding 500 metre, depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Labour only for spreading riddled earth as obtained from excavation work in trenches/ ducts for electric cable protection complete as specified and directed by Engineer-in-Charge. Note : Riddledationed earth specification shall be as per IS 1255.
Material and labour for shingle filling as in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled, and blinded with earth and rammed including watering, etc., complete all as specified and directed.
Lump sum price worked out by the Contractor for “ROAD , PATH AND HARD STANDING” as listed in Schedule ‘A’ Part - III representing _______ % ______________ percent Above / Below the lump sum price of `28,14,868.35 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “COMPOUND WALL ” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of `11,59,99,664.54 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `3,33,458.95 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - VI representing _______ % _________________ percent Above / Below the lump sum price of `9,26,072.18 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part - VII representing ______ % _________________ percent Above / Below the lump sum price of 67,13,296.24 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VIII representing ______ % _________________ percent Above / Below the lump sum price of `31,590.88 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of `56,230.43 inserted by the MES in Schedule ‘A’ Part - IX
Schedule 'A' Part - X This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 11.00 to 38.00
INTERNAL ELECTRIFICATION Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of cast iron /pressed steel terminal box of suitable sizes of 1.6mm thick duly painted on both side with anti corrosive paint, and with plasic laminated sheet cover 3mm thick fixed with brass screws, cup washer for mounting switches, sockets, regulators etc., and including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light point controlled by one, one way switch.
All as per Sl. Item No. 11 here-in-before but for one fan/ exhaust point controlled by one, one-way switch.
All as per Sl. Item No. 11 here-in-before but for one 3 pin socket outlet 5 Amp (independent) point controlled by one, one way switch.
All as per Sl. Item No. 11 here-in-before but for one 3 pin socket outlet 5 Amp point on the same board controlled by one, one way switch.
Point wiring complete with 2.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, and including provision of cast iron /pressed steel terminal box of suitable sizes of 1.6 mm thick duly painted on both sides with anti corrosive paint, and covered with plasic laminated sheet cover 3mm thick fixed with brass screw, cup washer for mounting switches, sockets, regulators etc., and including 2.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for 3-pin socket outlet, combination 5/15 Amp on independent board, complete all as specified and directed.
Supply and fix environment friendly, ltra modern, energy saving, surface mounted, decorative, oval, bulk head, edgelit LED luminaire comprising of high brightness LED 10 Watt with polycarbonate housing integrated electronic driver complete with all accessories including internally prewired, complete all as specified and directed.
Supply and fix LED tube light fittings 1X18 Watt, 4 fleet long wall mounted anodised aluminium extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries LED as light sources housing complete with all accessories including up with twin core twisted flexible copper cable of suitable size all as specified and directed.
Supply and fix ceiling fan complete with electronic type regulator and accessories 230 V, 1200 mm sweep, complete all as specified and directed.
Supply and fix exhaust fan metal type 300 mm sweep AC 230 Volts with all accessries and lovers, complete and including for provision of making hole through wall and making good the disturbed surfaces of wall complete all as specified and directed.
Supply and fix LED building security luminaries 20 watts pressure die cast aluminium housing IP-66 and replaceable integrated electronic driven as light sourcing houses complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, fix, conneting, testing and commissioning of high intensity, long range, auto swivel, LED search light, beam range 500 metres (min.), 1 x 200 W, singe, LED light, Efficiency>130 lm/w, PF>0.95, CCT 5500K-6500K, optical grade PMMA-PC lens, anti-UV oxidation, narrow beam 8 degree, die cast LM6 body with air fins, fully powder coated, working voltage 150-270, 50 Hz, constant current, reflector/ lens efficiency>90%, average lux level at 5 meter - 9000 (min.) with circle of approx 600mm, IP-65, confirming to LM79/ LM 80. This search light should be installed on disc of revolving mechanism with suitable motor-gear unit and design such to rotate 360º continuosly over the right in horizontal plane with speed controller (1 to 10 rpm) & R/F buttons and inbuilt push to tilting option upto 45 degrees. A separate wall mounted wire control panel (consist of MCBs, V-meter, Fuse, LED indicators) is supplied for smooth & safe operation remotely. The revolving mechanism is fully covered with weather & rust proof fiber box with maintenance window/ door and provision of 4 Nos. foundation holes at bottom for proper installation. Cat No. MRSL-LRFLL-25PC201, Make : Kalin or equivalent.
Taking down old unserviceable flood light fittings from the existing pole complete all as specified and directed.
Material and labour for painting of steel tubular LT poles with two coats of aluminium paint including painting to cross arms and clamps, etc., preparation of surfaces by scrubbing and cleaning with wire brush and renumbering the existing number of the pole as existing and as directed.
Supply and fix pole junction box sheet moulded compound (SMC) type with hinged door and locking arrnagement of size 300 x 200 x 105 mm ( internal) comprising one No. MCB single pole of capacity 6 Amps 240 Volts and one No. terminal for loop in & loop out suitable for three phase street light system including nuts and botlts connecting up complete, MS clamp fabricated from 25 x 3mm MS flat iron all as specified and directed. Make : Syntex or equivalent techno & commercial
Supply and fix new generation energy saving environmental friendly LED street light/ road way luminaries 70 watts presssure die cast housing with toughned glass and individual high power LEDs with secondary optics, with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges, high/ low voltage cutoff, open/short circuit protection and high powr factor LEDs as light source including fittings & connecting on existing and new street light pole brackets complete all as specified and as directed.
Material and labour for cutting the existing road/ hard standing surfaces to a depth of 60 cm and 50 cm width and getting out for laying under ground cable including returning, filling in, watering, well rammming in layers not exceeding 25 cm in soils and filling the top 15 cm thick with PCC 1:2:4, type B1 and finishing the top surface complete all as specified and directed.
Supply and fix in repairs of street light bracket made out of 40mm dia medium grade GI pipe of 1.5 M long bend to shape fixed with FI clamps with bolts, nuts and washers and painted with single coat of aluminium paint over a coat of red oxide primer painting complete.
Supply, install, test and commissioning LT cubical street light timer panel out door type (CPRI approved) confirming to relevant IS factory fabricated made out of 3 mm thick CRCA sheet duly powder coated and suitable size to accomodate all accessories/ fittings with 10 sqmm connecting copper power wire, suitable angle iron frame inlcuding foundation for fixing angle iron frame for panel, comprising of the following:- a) Digital 24 hrs timer b) Power contactor 63 Amps A3 - 01 No. c) MCB TPN 63 Amps 10 KA three pole 415 Volts - 01 No. d) Bakelite fuse cut out single phase, 63 Amps - 03 Nos. e) Indication lamp RYB - 01 set
Material and labour for Earthing in repairs with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly into the ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5metres below normal ground level connected to GI earth strp 32 x 6 mm by means of nuts, bolts, check nuts, washers, earth lead protected by 40mm dia GI pipe light grade and connected main distribution board/ earthing test point all as shown in electrical plate No. 3 of MES SSR Part - I and all as specified incuding testing on completion. Notes : The unit rate quoted by the tender shall be deemed to be inlusive of earth work excavation in any type of soil, PCC 1:3:6 Type C1 as in chamber, 40mm thick RCC 1:2:4, type B1 as in cover slab reinforced with 8mm dia TMT bars @ 150mm c/c both ways, GI funnel with GI watering pipe 20mm dia medium grade, wire mesh, GI earth stip 32 x 6 mm, protection pipe 40mm dia GI pipe light grade for earth lead upto 7.5m long
Material and labour for Earthing in repairs with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground, earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5metres below normal ground level connected to GI earth wire 4mm by means of nuts, bolts, checking nuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part - I connected to earthing test point including taking down the existing earthing plate, etc., excation/ earthwork in any type of strata, watering pipe with funnel, PCC Chamber with PCC cover slab without GI protection pipe all as specified and as directed.
EXTERNAL WATER SUPPLY Supply, install, test and commissioning of Pumping Set, centrifugal, electric driven, 3 PH, 415 V, 50 HZ, 5 HP inclusive of starter panel, cabling from panel board, foot valve, gate valves, non return valve of suitable dia, suitable dia of suction and dischage GI pipe including PCC foundation, etc., complete all as directed and as specified.
Material and labour for boring and tapping on existing DI/ CI pipe line and fixing 25 mm ferrule for taking out let connection for watch tower water supply, including earth work, complete all as directed and as specified.
Material and labour for cutting existing GI pipe line,taking out, cutting and threading for inserting union, GI Tee reducing on existing pipe line 50 mm dia GI line for taking out let connection of 25mm dia for watch tower water supply, inculding earth work and rela;ying of 50 mm dia line, complete all as specified and as directed.
SECURITY WALL Dismantling of barbed wire of any dia and guage complete all as specified and directed.
Dismantling of concentina coil of any dia and guage complete all as specified and directed.
M&L for Razor concertina coil, 610 mm dia, (50 spirals per coil), consisting of 2.6 mm dia heavy galvanised high tensile spring steel wire as per IS -4454, Barb (Barb length 24 + or - 1 mm, pitch between two barbs 35 + or - 1 mm) made of 0.5 mm thick low carbon heavy galvanised cold rolled steel sheet as per IS-513, heavy duty steel clip as per IS-2062 and Epoxy resin coating for anti-corrosion complete all as specified and directed.
Material and labour for preparing newly plastered surfaces of wall and applying two coat of exterior emulsion over a coat of primer after preparation of surfaces at any height including necessary scaffolding etc complete all as specified and as directed.
INTERNAL WATER SUPPLY Supply and fix brass chromium plated, 15mm bore health foucet, flexy type, 1.00m long of make as approved by GE, complete all as specified and directed.
Mehta Construction Co.
N. H. Saluji & Associates
surendra infrastructure pvt ltd
S. A. Yadav
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid