Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.7 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.9 L+₹1.3 L (2.62%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹51.0 L+₹2.3 L (4.81%)Rejected-Finance DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹71.5 L+₹22.8 L (46.9%)Rejected-Finance 121004 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | Rejected-Technical THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | - | Rejected-Technical DUE TO NOT ENLISTED IN PARTICULAR CATEGORY AS PER NIT |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
23 Jan 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
COMPREHENSIVE MAINT OF AIR COMPRESSOR SERVO VOLTAGE STABILIZERS FOR BALANCED UNBALANCED LOADS FREQUENCY CONVERTER RECTIFIER LIFT FIRE FIGHTING SYSTEM FIRE ALARM SYSTEM EOT CRANE UPS AND OTHER CONNECTED ITEMS AT AFS SULUR
2019_MES_309638_1
GE(AF)/SUL/Token/47 of 2019-2020
Open Tender
Miscellaneous Works
Item Rate
334 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
21 Feb 2020
26 Dec 2019
24 Jan 2020
26 Dec 2019
23 Jan 2020
9 Jan 2020
26 Dec 2019 - 8 Jan 2020
Amount
SCHEDULE A BOQ
Taking down old unserviceable scroll type compressor of capacity 7.5 TR and material and labour of scroll type compressor of capacity 7.5 TR and model of compressor, Model No. ZR72KCE-TFD-422 of Emerson Climate Technologies Make or equivalent suitable make for CRRW and SEW AC Plant. Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Taking down old unserviceable scroll type compressor of capacity 4.25 TR and material and labour of scroll type compressor of capacity 4.25 TR and model of compressor, Model No. ZR61KCE-TFD-422 of Emerson Climate Technologies Make or equivalent suitable make for T-51 (Avionics Lab) AC Plant. Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Comprehensive maintenance of Electric Powered Screw Air Compressor (EPSAC) Part No : E110-11AC, Free air delivery 16.9 cum/min, working pressure : 10.2 Kg/sqcm, Compressor drive motor -110 KW/ 147.5 HP, RPM-1485 of Make ELGI 3 phase including checking of airflow line, oil change, pressure switch setting, setting of safety valves, vibration and abnormal noise check, oil check/ oil consumption check, cleaning of air filters, checking functioning of valves, checking of gauge by the original manufacturer complete all as specified and directed. Location – LCA ETB Bldg.
Comprehensive maintenance of Air compressor 5 HP of Make ELGI 3 Phase including checking of airflow line ,oil change, pressure switch setting, setting of safety valves, vibration and abnormal noise check, oil check/oil consumption check, cleaning of air filters, checking functioning of valves, checking of gauge by the original manufacturer complete all as specified and directed, Location AVRO Hangar (02) Nos
Comprehensive maintenance of Screw Air compressor (ATLAS) Part No GA110-10, compressor drive motor-110 KW, 10 bar Make : Atlas Copco, 3 phase assembled with Air filter, compressor element, air receiver/ oil separator, air cooler, oil cooler, drive motor, gear casing, unloader, Elektronikon control system, air dryer with bypass valves etc including checking of airflow line, oil change, pressure switch setting, setting of safety valves, vibration and abnormal noise check, oil check/ oil consumption check, cleaning of air filters, checking functioning of valves, checking of gauge by the original manufacturer complete all as specified and directed. Location – LCA ETB Bldg.
Comprehensive maintenance of Air compressor 5 HP of Make Shakti 3 Phase including ,checking of airflow line ,oil change, pressure switch setting, setting of safety valves, vibration and abnormal noise check, oil check/oil consumption check, cleaning of air filters, checking functioning of valves, checking of gauge by the original manufacturer complete all as specified and directed, Location - 33Sqn New Hangar
Note for Item No 4 to 7:- (a) The above, maintenance shall be done through authorised person of OEM. The contractor shall make AMC contract with the original manufacturer of Air compressor and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to servo stabilizer noticed during the period 11 months by providing materials and labour.
Comprehensive maintenance of 40KVA true online UPS system with SMF batteries, with input supply of 3 phase 415V,50HZ . of Make Aplab including attending day to day complaints , isolating UPS from system,Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. Location generator set room(02 no), (i) Any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of 40KVA static frequency converter with input supply of 3 phase 415V,50HZ with output of 115 V,400HZ. of Make Aplab including attending day to day complaints , isolating converter from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carried out through the original manufacturers only. Location Generator Room(i) Any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of 30KVA static frequency converter with input supply of 3 phase 415V,50HZ with output of 115 V,400HZ. of Make Aplab including attending day to day complaints , isolating converter from system,Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carried out through the original manufacturers only. Location Generator Room (i) Any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of DC power supply (Rectifier)28 Volts DC Output,20 KW with input supply of 3 phase 415V,50HZ. of Make Aplab including attending day to day complaints, isolating converter from system,Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. Location Generator Room, (i) Any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of 25KVA true online UPS system with SMF batteries,20 KW with input supply of 3 phase 415V,50HZ . of Make Aplab including attending day to day complaints , isolating UPS from system,Opening up,examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge. Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. Location Instrument Rotable, generator set room,(i) Any minor items to be replaced is included in the item rate quoted.
Comprehensive maintenance of 3 phase oil cooled servo stabilizer with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 125KVA of Make Power One including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system as directed by the Engineer -in-charge Note:-(a) The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. Location SRE bldg
Comprehensive maintenance of 25KVA static frequency converter with input supply of 3 phase 415V,50HZ with output of 115 V,400HZ. of Make Aplab including attending day to day complaints , isolating converter from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. as directed by the Engineer -in-charge, Note:-(a) The contractor shall make AMC contract with the original manufacturer of the equipment and the repairs/maintenance shall be carried out through the original manufacturers only. Location Generator Room,(i) Any minor items to be replaced is included in the item rate quoted
Note For item No 9 to 15 :- (a) (a) The above, maintenance shall be done through authorised person of OEM. The contractor shall make AMC contract with the original manufacturer of Air compressor and the repairs/maintenance shall be carried out through the original manufacturers only. (b) Payment shall be made thrice in a year proportionately, for compehensive mantenance for the period of 11 months.
Sealed Maintenance Free (SMF) battery of capacity 12 V, 65 AH, suitable for existing 3 phase online UPS as required at location including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide of model No. EP 65 or equivalent in Amar raja (Power Zone)/ Amaron Note :- (i) The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Chare throughout the currency of contract.
Periodical Examination, normal and routine maintenance ,as per manufacturer’s instructions, Repair and periodical maintenance of indoor ,single Girder heavy duty electrically operated travelling (EOT) over head crane capable of handling 2.00 Tonnes capacity – 01 No, suitable for 415 volts, 50 Hz 3 phase, 4 wire, AC supply with clear hook height of 3.5 Mtrs from FFL including floor operated movable pendent control by means of push buttons independent of crab trolley position with protective panel with down shop lead (DSL) trailing cables and earthing etc, complete comprise of (a) class of Duty-CLII as per IS 807 & IS 3938 indoor, (b) Crane span-8.10Mts (c) Longitudinal travel shall be limited to 1.0 m away from the walls on both ends. (d) EOT crane shall be provided with the following electrically controlled. (i) Longitudinal Travel speed-20mpm (100%)-2mpm (10%), (ii) Cross travel speed -12 mpm (100%)-1.20mpm (10%), (iii) Hoisting speed – 6 mpm(100%) – 0.60 mpm (10%), (iv) Longitudinal Travel motor – 2X0.5 HP (SQC), (v) Cross travel motor – 0.33 HP (SQC), (vi) Hoisting motor – 4 HP (SQC) installed at Location – LCA ETB Bldg. Make :- Stanmek Ingenieurs Notes : - (i) The contractor shall make AMC contract with the authorised dealer of the equipment and the repairs/ maintenance shall be carried out through the authorised dealer only. (ii) Any minor items to be replaced is included in the item rate quoted. (iii) The contractor shall provide four visit of authorised dealer for servicing of the eqpt and eight visit on phone call visit for attending emergency brake downs during the entire contract period.
Periodical Examination, normal and routine maintenance ,as per manufacturer’s instructions, Repair and periodical maintenance of indoor ,single Girder heavy duty electrically operated travelling (EOT) over head crane capable of handling 3.00 Tonnes capacity – 01 No, suitable for 415 volts, 50 Hz 3 phase, 4 wire, AC supply with clear hook height of 3.5 Mtrs from FFL including floor operated movable pendent control by means of push buttons independent of crab trolley position with protective panel with down shop lead (DSL) trailing cables and earthing etc, complete comprise of (a) class of Duty-CLII as per IS 807 & IS 3938 indoor, (b) Crane span-8.38Mts (c) Longitudinal travel shall be limited to 1.0 m away from the walls on both ends. (d) EOT crane shall be provided with the following electrically controlled. (i) Longitudinal Travel speed-20mpm (100%)-2mpm (10%), (ii) Cross travel speed -12 mpm (100%)-1.20mpm (10%), (iii) Hoisting speed – 6 mpm(100%) – 0.60 mpm (10%), (iv) Longitudinal Travel motor – 2X0.75 HP (SQC), (v) Cross travel motor – 0.5 HP (SQC), (vi) Hoisting motor – 5 HP (SQC) installed at Location – LCA ETB bldg. Make :- Stanmek Ingenieurs Notes : - (i) The contractor shall make AMC contract with the authorised dealer of the equipment and the repairs/ maintenance shall be carried out through the authorised dealer only. (ii) Any minor items to be replaced is included in the item rate quoted. (iii) The contractor shall provide four visit of authorised dealer for servicing of the eqpt and eight visit on phone call visit for attending emergency brake downs during the entire contract period.
Calibration of load testing with certification through Govt authorised dealer for Electrically operated single girded EOT Crane 2.0 Ton capacity with power supply of 3 phase 415V, 50 Hz suitable for 8.10 Mtr span and 3.5 Mtr height of lift hooks, pendent type operation Make- Stanmek Ingenieurs as directed by Engineer-in-Charge.
Calibration of load testing with certification through Govt authorised dealer for Electrically operated single girded EOT Crane 3.0 Ton capacity with power supply of 3 phase 415V, 50 Hz suitable for 8.38 Mtr span and 3.5 Mtr height of lift hooks, pendent type operation Make- Stanmek Ingenieurs as directed by Engineer-in-Charge.
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. 3 phase and neutral 350 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/ DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 60 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :- (a) MCCB, with thermal magnetic release , 4 Pole, 250 Amps, 36 KA, 415 Volt, 50 Hz - 1 No. (Make of switch gear :- L&T, Schnieder, ABB). Make of LT Panel/ FPB shall be as mentioned in list of makes (PS)
Supply and fixing of DC MCCB 125 amps 25 KA 4 pole suitable for 28V DC power supply of Make LEGRAND/ L&T/ Siemens .
Comprehensive maintenance of 3 phase oil cooled servostabilizer of Make BEC with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 150KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location DWR BLDG
Comprehensive maintenance of 3 phase oil cooled servostabilizer with input variation between 340V to 400V with output stabilized at 415 Volts of capacity 250KVA with all spares including isolating stabilizer from system, Opening up, examining the accessories parts,cleaning,soldering as required and testing and connecting back with the system. periodical maintenance as recommended by the original manufacturer complete all as specified and directed. Location Rubber store
Note for Item No 24 & 25:- (a) The above, maintenance shall be done through authorised person of OEM. The contractor shall make AMC contract with the original manufacturer of servo stabilizer and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to servo stabilizer noticed during the period 11 months by providing materials and labour.
Supply only Microprocessor board of servostablizer of capacity 50KVA to 250KVA and including taking existing one all as specified and as directed.
Supply only DC Capacitor suitable for 5 to 50KVA true online UPS and including taking existing one of all as specified and directed. Make - Aplab
Supply only Cooling fan suitable for 40 to 50KVA Frequency converter and including taking existing one of Make - Aplab all as specified and directed.
Comprehensive maintenance of 680 Kgs/10 passengers capacity, passenger lift of Make: Johnson to serve ground floor plus four floors, operation, Examining, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell, etc complete all as specified and directed. Machine No of Lift - L/C 7489, Location: SRE Building at 43 wing Air force station Sulur. Note: (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to lift noticed during the period by providing materials and labour.
Comprehensive maintenance of passenger lift to carry goods of 2000 kg capacity with a speed of 0.5 metre/sec, of Make : Johnson to serve ground floor and three upper floors with AC variable voltage & variable frequency drive(VVVF DRIVE) system, microprocessor based control system all as per IS 14665 hall position indicators on all floors, car position indicators in cabin, battery operated alarm bell and emergency lights including cabin light & fan over load switch, auto revelling, intercom facility with centre opening, stainless steel power operated sliding doors, operation, Examining, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell , etc. complete all as specified and directed. Machine No of Lift (L-H8229), Location : DWR Building at 43 wing Air force station Sulur Note: (a) The contractor shall make AMC contract with the original manufacturer of lift and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to lift noticed during the period by providing materials and labour.
Comprehensive maintenance of passengers lift to carry 8 passengers (544 Kgs) capacity with a speed of 1 metre/ sec, of Make: OTIS to serve ground floor and 4 upper floors with AC variable voltage and variable frequency drive (VVVF DRIVE) system, micro processor based controol system all as per IS 14665 hall position indicators on all floors, car position indicators in cabin, battery operated alarm bell and emergency lights including cabin light and fan over load switch, auto revelling, intercom facility with centre opening, stainless steel power operated sliding doors, operation, examining, adjusting, lubricating and repairs as required to machine motor, controller parts, safety devices, governors, repair/ replacement as required to alarm bell, indicators, emergency light, emergency components, including low voltage protection relay, call bell, etc. complete all as specified and directed. Machine No of Lift (MG055702), Location : New ATC Building at 43 Aing Air Force Station Sulur - 02 Nos. Note: (a) The contractor shall make AMC contract with the authorised service agency of lift and the repairs/ maintenance shall be carried out through the authorised service agency only. (b) The rate quoted shall be deemed to include for carried out all repairs to lift noticed during the period by providing materials and labour.
Sealed Maintenance Free (SMF) battery of capacity 12 V, 120 AH, suitable for existing 3 phase online UPS as required at location including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide of model No. EP 65 or equivalent in Amar raja (Power Zone)/ Amaron Note :- (i) The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation. (ii) The contractor shall supply SMF battery as per requirement given by Engineer-in-Charge throughout the currency of contract.
Comprehensive maintenance of fire fighting system comprising of Main pump of capacity not less than 60HP, Jockey pump not less than 10 HP, Diesel driven pump 60HP controlled by auto control panel and SCADA panel, pressure gauges for automatic operation of fire pumps and fire hydrants etc. periodical maintenance as recommended by the original manufacturer including replacement of minor spares not mentioned here-in-before complete all as specified and directed. Location SRE Bldg
Comprehensive maintenance of firefighting system comprising of Main pump of capacity not less than 60HP, Jockey pump not less than 10 HP, Diesel driven pump 60HP controlled by auto control panel and SCADA panel, pressure gauges for automatic operation of fire pumps and fire hydrants etc. periodical maintenance as recommended by the original manufacturer including replacement of minor spares not mentioned here-in-before complete all as specified and directed. Location DWR Building. Note For item no.173 & 174: (a) The contractor shall make AMC contract with the original manufacturer of firefighting and the repairs/maintenance shall be carried out through the original manufacturers only. (b) The rate quoted shall be deemed to include for carried out all repairs to firefighting system noticed during the period by providing materials and labour.
Supply only fire hydrant valve single headed 63mm dia, with ISI marked complete all as specified and directed
Supply only RRL hose type-A suitable for fire hydrant 63mm dia, with ISI marked complete all as specified and directed.
Supply and install External Wireless Siren Strobe– A Fully Supervised Power Code Outdoor (IP55) Wireless Siren and Strobe Light. Designed For External Installation .Wirefree Connection between Control panel and Siren,Covenient and Rapid No-Mess installation, Separate Fire Alarm Signals, 98db Piezo Siren and High Power Strobe Light , Weather – Resistant IP55 , Two- Way Communication , For Local & Remote Diagnostics, Plug-in Power Supply, NIMH Rechargeable Backup Battery, Transmits Status , Tamper, Low Battery Supervisory and AC Loss Messages to the Control Panel, Tri- State Tamper Switch Identifies Screw Manipulation Removal of Cover or Prying from the Wall.Model/make:-Ceasefire / Visionic / Apollo / Siemens / Honeywell (Morley). Location : T-45, T-46, T-31, T-5, T-6, T-7, T-8 Hangers and Radiography Hanger, DWR, SRE & New ATC
Supply and install wireless repeater to extend the communication range of detectors by relaying data between receiver and remote wireless transmitters up to 16 auxiliay repeaters can be positioned between the farthest group of receiver transmitter and receiver transmitter, receive type-super-regenrative, modulation tyep-100% ASK, Power Input Ranges- 13 - 20 VDC, or 11 - 16 VAC, 100 mA min.,.Backup Battery- 9 V-style rechargeable Ni-Cd or Ni-MH. Battery Backup Duration (with fully charged 120 mA/h battery and 1:1 standby/transmit ratio): 2 hours (315 and 433.92 MHz units),LED indicator-Lights during transmission,Compliance with Standards-Meets FCC Part 15, MPT 1340 and directive 1999/5/EC, including adapter-AC/DC 12VAC, 1Amp, battery-9 V rechargeable Ni-Cd or Ni-MH ; 300mAh, 5 hours (315 and 433.92 MHz units).Model/make:-Ceasefire / Visionic / Apollo / Siemens / Honeywell (Morley). Location : T-45, T-46, T-31, T-5, T-6, T-7, T-8 Hangers and Radiography Hange, DWR, SRE & New ATC
Comprehensive maintenance of addressable fire alarm system installed at New ATC Bldg including testing functionality of all components, testing of smoke detector (using insence stick), heat detector (using hot air blower), beam detector (using obstracle method) and cleaning of all devices, replacement of defective spares/ components, comprising of following all as specified and directed. Make – HONEYWELL (MORLEY-IAS) (i) Fire alarm control panel panel micro processed based intelligent four loop upto 200 Detectors in modules. (ii) Multisensory with heater smoke Detector – 262 Nos (iii) Heat detector – 02 Nos (iv) Manual call point – 30 Nos (v) Sounder cum strobe-46 Nos (vi) Response indicator – 67 Nos (vii) Control module – 1 No (viii) Isolator – 12 Nos (ix) Battery backup 7 AH,12 V, Make- MORLEY-IAS -2 Nos.
Supply and install Smoke detector – cover range-50-100 cubic meters(1770-3530 cubic ft) Fully supervised smoke Detector Photoelectric Detection Technology for superior Detection sensitivity, sound and Transmitted Alerts For Smoke, Tamper and Low Battery, works on Power code Protocol, Easy Programming and Enrolling to the control panel, Long Life 9 Volt Alkaline or Lithium Battery- type-3V Cr 123A, operating temperature- -10 ͦC to 50 ͦ C (14 ͦ Fto 122 ͦ F), Simple ceiling , Mount installation with Separate Installation bracket . Model/make:- Ceasefire / Visionic / Apollo / Siemens / Honeywell (Morley). Location : T-45, T-46, T-31, T-5, T-6, T-7, T-8 Hangers and Radiography Hanger, DWR, SRE & New ATC bldg
Supply, Installation, Testing and Commissioning of Conventional Photoelectric Smoke Detector. Features including removable, High performance chamber, Automatic Sensitivity Window Verification (ASWV)- Drift compensation technology, remote indicator output, wide voltage range (9.5-30 V dc), low profile design with one piece outer cover, single fire LED-360° viewing ,approved by LPCB. Make:- Ceasefire / Visionic / Apollo / Siemens / Honeywell (Morley). Location : T-45, T-46, T-31, T-5, T-6, T-7, T-8 Hangers and Radiography Hanger, DWR, SRE & New ATC bldg
Supply, Installation, Testing and Commissioning of convetional manual call point features approved to with EN 54-11:2001,terminals can accomodate upto 2.5mm solid conductor,approved by LPCB. Make. Ceasefire / Visionic / Apollo / Siemens / Honeywell (Morley). Location : T-45, T-46, T-31, T-5, T-6, T-7, T-8 Hangers and Radiography Hanger, DWR, SRE & New ATC bldg
Servicing/ comprehensive maintenance of fire fighting system and fire alarm system comprising of Smoke detection control panel (to accommodate and sensing signals from wireless smoke detectors), Smoke detector (Photoelectric detection Technology), External wireless siren strobe, wireless repeater to extend the communication range of detectors, Conventional Fire Alarm control panel, IR3 Infra Red flame detector, conventional manual call point with EN 54-11 : 2001 and LPCB, conventional sounder etc by attending fault testing of system, quarterly checking of system including preventive maintenance by replacing small spare parts complete all as specified and directed. Location : T-45, T-46, T-31, T-5, T-6, T-7, T-8 Hangers and Radiography Hanger - 8 Nos.
Note :- (a) The contractor shall make AMC contract with the authorised service agency of any make for fire fighting equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The rate quoted shall be deemed to include for carried out all repairs noticed during the period by providing materials and labour. (c) The authorised service agency must be attended as and when called for urgent nature of repair of the fire fighting equipments. (d) Checking of Alarm signal should not lost when primery power failure untill the alarm signal processed. (e) Checking of audio amplifiers and tone genrating equipment. (f) Checking of smoke detector sensibility (g) Checking of all speaker circuit and loops.
eurekaenterprises
Sreekrupa Enterprises
Neptune Engineers and Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .