Executive Engineer Electrical
602 6th floor BSNL Bhavan Hillfort Road Adarshnagar Hyderabad
Dismantling shifting and ITC of 4 Nos 7TR Precision Package AC units from TE Musheerabad to STR TBN Hyderabad SH ITC of 4 Nos 7TR Precision Package AC units at STR 3rd floor Telephone Bhavan, Hyderabad
2020_BSNL_53585_1
29/BEDH-II/2020-21
Open Tender
Electrical Works
Item Rate
30 days
Hyderabad
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹11,048
30 Jul 2020
22 Jul 2020
30 Jul 2020
23 Jul 2020
29 Jul 2020
23 Jul 2020
Amount
Dismantling of existing outdoor units of 7 TR Package AC units including refregerant line and other related items at 3rd floor Telephone Bhavan and shifting to suitable location in the same floor to provide space for new condensers etc as reqd
Installation of existing 7TR Precision Package type AC units complete with all components and air cooled condenser on existing PCC foundation/ floor /existing MS structure etc as required.
Testing & commissioning of existing 7TR Package type AC units as per the instructions of Engineer-In-Charge & as per standard testing procedures (Note: Testing & Commissioning of the units shall be done by M/s Stulz representative only, Liasoning with M/s stulz has to be done by the agency.Commissioning report of Stulz shall be submitted)
Providing gas Charging for Package AC units with 407C Refrigerent along with vaccumisation, nitrogen pressure testing, leak testing with halide torch, arresting leaks etc as required.
Supplying and fixing of copper refrigerant piping of minimum 18 G (1.2 mm) thickness of following sizes with all accessories including cutting, bending, jointing, brazing & painting etc. for hot gas and liquid lines of a single circuit, on existing GI perforated tray including insulating the refrigerant lines inside AC area with suitable fire retardant polythene foam complete as per specifications attached.
(a) Hot Gas Line, 7/8" nominal dia.
(b) Liquid Line, 1 1/8" nominal dia.
Supply and fixing of 1.1 KV grade PVC/XLPE insulated PVC sheathed copper conductor armored cable of the following size on the existing MS angle tray (with saddles) & end termination of cable with glands/lugs etc. as required. a). 3 x 2.5 sq. mm (for condensers)
Supplying and laying 25x5mm GI strip on surface or in recess for earth extension etc.,as required.
Supplying and Laying of 10Sq.,mm size of Copper cable for Extension of Earthing from GI earth strip to equipment body etc., as required.
Providing copper lugs for 10Sq mm Copper wire including crimping etc., as required.
Providing plumbing work for humidification circuits and drainage requirements including supply of ISI marked Class-II SDR-13.5 CPVC Pipes (Chlorinated Polyvinyl Chloride material as per IS-15778) with threaded fittings such as bends, reducers, adapter, elbows, tees, unions, coupler, end caps, flanges etc. for water connection of various components of the system complete with plumbing work by applying cleaner, solvent cement, primer, teflon tape & various size of metal clamps for fixing pipes etc as reqd.
a). 25 mm dia (Humidification package)
b) 2" dia (Drain line)
Supply, installation, balancing and commissioning of GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
a) Thickness 0.80 mm sheet (22 gauge)
b) Thickness 0.63 mm sheet (24 gauge)
Providing MS structure for Outdoor Units / referigerant pipe & cables made out of solid channels / angles/flats etc i/c cutting, welding, grouting, fixing with hardware & painting etc as required.
Supply and fixing of 1.1 KV grade PVC/XLPE insulated PVC sheathed copper conductor armored cable of the following size on the existing MS angle tray (with saddles) along with 2 x 2.24 mm dia. bare copper wire for loop earthing & end termination of cable with glands/lugs etc. as required. a). 4 x 16 sq. mm (for pr pkg unit)
Laying of the recovered cable Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) from 7th floor AC plant along with removing and relaying along with end termination etc as reqd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .