| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAdmitted-Finance B 80 ANAND VIHAR ANAND VIHAR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | L1 | Admitted-Finance | |
| 2 | L2₹14.0 L+₹3,540 (0.25%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Powersure Technologies L1 | APURV ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.01 | SITC of full bore electromagnetic flow meter, working on faradays law of electromagnetic induction and should be having two parts the flow sensor (primary head) and Flow transmitter / converter. The Flow sensor shall have 2 built in sensing electrodes of SS 316. The liner material shall be strictly PTFE or Hard Rubber with drinking water approval from CFTRI. The liner approval should be submitted with the offer. The flow meters should be calibrated at 3 points with water as medium at the manufacturer in house NABL accredited volume flow calibration facility in India. In case the flow meter manufacturer facility is not NABL accredited then flow meter calibration should be compulsory done at FCRI Palakkad only. Operating pressure : Max pressure 10 Kg/cm2 g, Operating temperature: 0 °C to 60 °C max , Fluid: Water, FLOW SENSOR ( PRIMARY HEAD), Type : Pulsed DC excitation, MOC of Flow tube/Meter Tube: SS 304, Lining material : Hard Rubber or PTFE, Measuring Electrode material: SS 316. Meter Flange type & MOC : Fixed Welded Flanges in CS. (Lap joints flanges or Wafer Design not acceptable), Meter Flange Pressure Rating: ANSI 150#, Flow Sensor Coil housing type & MOC: Fully Welded Construction., Material: SS 316, Junction Box MOC: SS 316 or Die Cast Aluminium, Earthing Type. Grounding Ring of SS 316 on both sides of the meter, Ingress Protection: IP 67. FLOW TRANSMITTER (CONVERTER), Type: Microprocessor based, Remote/compact Version, Power supply: Universal…100…230 VAC (-15% / +10%), 50/60 Hz OR 24 VDC suitable for Solar system, Type of display: 2 Line Backlit LCD display, Display parameter: Instantaneous Flow, Sum Totalizer Flow, Forward / Reverse Totalizer, Flow Direction, Status symbols, Measuring accuracy: ±0.5% of the measured value for velocity > 0.5 m/S, Input: From flow Sensor, Outputs: 1 X 4-20mA ( HART), 1 X Pulse,1 X MODBUS RS 485,1 X Status (For Diagnosis),Communication Interface:,1 X MODBUS RS 485, 1 X HART, Application Diagnostic Functions: Empty Pipe Detection, Flow Exceeding Limit, Device/ Hardware Error, Totalizer Overflow, High Electronics Temperature. Enclosure MOC: Die Cast Aluminium, Enclosure protection class: IP 67, Programming: Keypad or Magnetic or Optical, Cable Glands: 4 nos. M20 X 1.5 Polyamide cable glands. The job involves removing the existing eviation - ? 2 mm, Beam angle - 4° , Measuring frequency- W-band (80 GHz technology), Output signal - 4 … 20 mA/HART, Mounting connection Thread G1, 1 NPT, R1, Process pressure -1 … +3 bar (-100 … +300 kPa), Process temperature -40 … +80 °C (-40 … +176 °F) Ambient temperature - 40 … +80 °C (-40 … +176 °F), Bluetooth standard - Bluetooth 5.0, Effective range - Bluetooth typ. 25 m (82 ft), Operating voltage - 12 … 35 V DC, Protection rating - IP66/IP68 (3 bar) acc. to IEC 60529, Type 6P acc. to UL 50. The system will have one no. Digital Radar Level Sensor, One no. Digital Remote Display, Required signal cable, Enclosure (if required) for Sensor, Power Cable etc. plus installation, testing and commissioning charges. Make : VEGA/SIEMENS/EIP. Flow meters, placing them in DJB store, Installing and commissioning of the flow meter and accessories. The flow meter should be IP 68 to stop damage by ingression of water/seepage. Custody and responsibility of the above system will be in customer's scope after commissioning. In case of foreign manufacturers who do not have manufacturing facility in India the Flow meter 3 point water calibration should be compulsory done at FCRI Palakkad only. The accuracy of manufacturer's in house volume flow calibration lab should be at least 3 times better than accuracy of the flow meter. Accuracy of manufacturer's in house volume flow calibration lab should be mentioned in NABL accreditation and should be less than +/- 0.1%. Testing of meters: Magnetic flow meter manufacturer should carry out the following test on every single flow meter during the manufacturing process and below test certificates should be provided for review during inspection and finally all certificates supplied along with the material: Three Point Water calibration certificate, Hydro test certificate, Material test certificate for Electrode, Coil housing & flow tube, Test and Guarantee Certificate. 0Separate Transmitter panel, LPU, FIT, MCB, power cable and signal cable of reputed make should also be provided. Make Forbes (Krohne) Marshall /Siemens /EIP/ Any DJB Approved make . 300 mm PN 10 | 1 | No. | 11,80,000 ₹13,92,400 Lowest | 11,83,000 ₹13,95,940 |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
25 Jul 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Office of the Ex. Eng. (E and M) M-II
Pocket-A, Dilshad Garden, Delhi-110095
SITC of FBFM at delivery line at W-I ranney well near sangam raw water at Wazirabad road. (Re-invite)
2025_DJB_275741_9
NIT No. 08 (25-26)
Open Tender
Miscellaneous Works
Works
60 days
Wazirabad road.
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Ac No. 50448339804
₹28,000
25 Sept 2025
19 Jul 2025
25 Jul 2025
19 Jul 2025
25 Jul 2025
19 Jul 2025
SITC of full bore electromagnetic flow meter, working on faradays law of electromagnetic induction and should be having two parts the flow sensor (primary head) and Flow transmitter / converter. The Flow sensor shall have 2 built in sensing electrodes of SS 316. The liner material shall be strictly PTFE or Hard Rubber with drinking water approval from CFTRI. The liner approval should be submitted with the offer. The flow meters should be calibrated at 3 points with water as medium at the manufacturer in house NABL accredited volume flow calibration facility in India. In case the flow meter manufacturer facility is not NABL accredited then flow meter calibration should be compulsory done at FCRI Palakkad only. Operating pressure : Max pressure 10 Kg/cm2 g, Operating temperature: 0 °C to 60 °C max , Fluid: Water, FLOW SENSOR ( PRIMARY HEAD), Type : Pulsed DC excitation, MOC of Flow tube/Meter Tube: SS 304, Lining material : Hard Rubber or PTFE, Measuring Electrode material: SS 316. Meter Flange type & MOC : Fixed Welded Flanges in CS. (Lap joints flanges or Wafer Design not acceptable), Meter Flange Pressure Rating: ANSI 150#, Flow Sensor Coil housing type & MOC: Fully Welded Construction., Material: SS 316, Junction Box MOC: SS 316 or Die Cast Aluminium, Earthing Type. Grounding Ring of SS 316 on both sides of the meter, Ingress Protection: IP 67. FLOW TRANSMITTER (CONVERTER), Type: Microprocessor based, Remote/compact Version, Power supply: Universal…100…230 VAC (-15% / +10%), 50/60 Hz OR 24 VDC suitable for Solar system, Type of display: 2 Line Backlit LCD display, Display parameter: Instantaneous Flow, Sum Totalizer Flow, Forward / Reverse Totalizer, Flow Direction, Status symbols, Measuring accuracy: ±0.5% of the measured value for velocity > 0.5 m/S, Input: From flow Sensor, Outputs: 1 X 4-20mA ( HART), 1 X Pulse,1 X MODBUS RS 485,1 X Status (For Diagnosis),Communication Interface:,1 X MODBUS RS 485, 1 X HART, Application Diagnostic Functions: Empty Pipe Detection, Flow Exceeding Limit, Device/ Hardware Error, Totalizer Overflow, High Electronics Temperature. Enclosure MOC: Die Cast Aluminium, Enclosure protection class: IP 67, Programming: Keypad or Magnetic or Optical, Cable Glands: 4 nos. M20 X 1.5 Polyamide cable glands. The job involves removing the existing eviation - ? 2 mm, Beam angle - 4° , Measuring frequency- W-band (80 GHz technology), Output signal - 4 … 20 mA/HART, Mounting connection Thread G1, 1 NPT, R1, Process pressure -1 … +3 bar (-100 … +300 kPa), Process temperature -40 … +80 °C (-40 … +176 °F) Ambient temperature - 40 … +80 °C (-40 … +176 °F), Bluetooth standard - Bluetooth 5.0, Effective range - Bluetooth typ. 25 m (82 ft), Operating voltage - 12 … 35 V DC, Protection rating - IP66/IP68 (3 bar) acc. to IEC 60529, Type 6P acc. to UL 50. The system will have one no. Digital Radar Level Sensor, One no. Digital Remote Display, Required signal cable, Enclosure (if required) for Sensor, Power Cable etc. plus installation, testing and commissioning charges. Make : VEGA/SIEMENS/EIP. Flow meters, placing them in DJB store, Installing and commissioning of the flow meter and accessories. The flow meter should be IP 68 to stop damage by ingression of water/seepage. Custody and responsibility of the above system will be in customer's scope after commissioning. In case of foreign manufacturers who do not have manufacturing facility in India the Flow meter 3 point water calibration should be compulsory done at FCRI Palakkad only. The accuracy of manufacturer's in house volume flow calibration lab should be at least 3 times better than accuracy of the flow meter. Accuracy of manufacturer's in house volume flow calibration lab should be mentioned in NABL accreditation and should be less than +/- 0.1%. Testing of meters: Magnetic flow meter manufacturer should carry out the following test on every single flow meter during the manufacturing process and below test certificates should be provided for review during inspection and finally all certificates supplied along with the material: Three Point Water calibration certificate, Hydro test certificate, Material test certificate for Electrode, Coil housing & flow tube, Test and Guarantee Certificate. 0Separate Transmitter panel, LPU, FIT, MCB, power cable and signal cable of reputed make should also be provided. Make Forbes (Krohne) Marshall /Siemens /EIP/ Any DJB Approved make . 300 mm PN 10
APURV ENTERPRISES (BID ID -1605452)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .