Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹21.7 L+₹37,102.50 (1.74%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹35.9 L+₹14.6 L (68.6%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Tughlakabad
HQ CWE (AF) Tughlakabad
CA NO. CWE/TKD/TOKEN-15/2020-21
2020_MES_354579_1
CA NO. CWE/TKD/TOKEN-15/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Tughlakabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) Tughlakabad
₹60,000
Yes
24 Aug 2020
20 Jun 2020
18 Jul 2020
20 Jun 2020
16 Jul 2020
4 Jul 2020
60 days
Amount
M&L in replacement for 1 loop networkable surface mounting FACP certified by a notified body to EN54-2/EN54-4 norms, having networkable capability of up to 64 panels with 500 software zones. Large with 8x40 character LCD. In order to facilitate re-configuration and system extension, the allocation of addresses to devices shall be independent of their physical arrangement on the loops and sensitivity adjustment and drift compensation. The FACP shall be capable to analogue addressable wired and wireless sensors & modules up to 127, plus 127 analogue base sounder/ Beacon for total 254 point shall be configured on each addressable loop. The FACP shall have an event log capable of storing the last 500 events that have occurred. Loop powered sounders incorporated as a sensor bases shall be available.
Contd.. Srl Item No. 1.00 here-in-before... The FACP shall have the capability to support sub-addressing of addressable modules. The FACP shall monitor all critical system components and interconnections, internal and external, such that a failure, which would prevent the correct operation of the alarm functions, causes the FAULT indicator to light and a message to be given on the alphanumeric display within 60 seconds of occurrence. The FACP shall support minimum four access levels, flash EPROM, programmable sounder circuits. The FACP shall be housed in MS Power coated cabinet, complete with exclusive notification circuits, and with fire, fault and auxiliary relays. The panel shall support programmed as a node on a peer to peer network with other panels , complete all as specified and directed.Make:- Hochiki/Ceasefire
Supply, installation, testing and commissioning in replacement of microprocessor based 8 Zone conventional fire alarm control panel robustly designed and easy to operate, fully compliant with and tested to BS EN 54-2 and BS EN 54-4, Compatible for use on BS5839, Part 1, 2002 installation, 2 wire repeaters and ancillary boards, fully programmable using simple menu options, simple, single board construciton, installer friendly, compatible with Hochiki, conventional range of devices, two monitored sounder outputs, 3 Amp power supply, auxiliary power output, The control must be EN 54 approved, complete all as specified and as directed. Make : Ceasefire/Honeywell/LTS/Agni
Supply, installation, testing and commissioning in replacement of microprocessor based 4 Zone conventional fire alarm control panel robustly designed and easy to operate, fully compliant with and tested to BS EN 54-2 and BS EN 54-4, Compatible for use on BS5839, Part 1, 2002 installation, 2 wire repeaters and ancillary boards, fully programmable using simple menu options, simple, single board construciton, installer friendly, compatible with Hochiki, conventional range of devices, two monitored sounder outputs, 3 Amp power supply, auxiliary power output, The control must be EN 54 approved, complete all as specified and as directed. Make : Ceasefire/Honeywell/LTS/Agni
M&L in replacement for Analogue Addressable photo Electric smoke sensor having high performance chamber with twin fire LED's allowing 360 degree viewing, lock mechanism (sensor to base), can adjust sensitivity range between 1% to 4.5% obs/mtr at any level, electronically addressed, approved by LPCB. Flat response technique which nullifies the need for having ionisation detectors, Devices include high performance optical chamber for effective and accurate analysis of causes of fire. Fast addressing technique flexible (programmed in any sequence), automatic (stored in EEPROM), complete all as specified and directed.Make:-Hochiki/Ceasefire
Supply, installation, testing and commissioning in replacement of (multi criteria) type detector with base combination of both heat and smoke detection arrangement of the same make as of fire alarm control panel. Detector should have a third terminal to provide an integral remote indicator output, removable high performance chamber, remote indicator output, wide voltage range (9.5 to 30V d.c) low profile design with one piece outer cover, twin fire LED's allow 360 degree viewing, range of mounting bases, approved by LPCB complete all as specified and as directed. Make : Ceasefire/Hochiki/LTS/Agni
M&L in replacement for Analogue addressable manual call point having status LED for alarming and standby mode, inbuilt short circuit isolator, electronically addressed approved by LPCB as EN54-11 : 2001. Rapid response using operation of a call point to the system indicating fire condition is typically less than 1.5 seconds FAST addressing technique flexible (programmed in any sequence), Automatic (stored in EEPROM), Secure (cannot be changed easily) and time saving, complete all as specified and directed.Make:-Ceasefire/Hochiki/LTS/Agni
M&L in replacement for Analogue addressable water proof heat sensor with IP67 rating, having removable high performance chamber with twin fire LED's allow 360 degree viewing, lock mechanism (sensor to base), employ two heat sensing elements with different thermal characteristics to provide a rate of rise dependent response. Electronically addressed, approved by LPCB. Flat fast addressing technique flexible (programmed in any sequence), Automatic (stored in EEPROM). (EN-54 approved), complete all as specified and directed.Make:-Ceasefire/Hochiki/LTS/Agni
M&L in replacement for Analogue addressable single main rated relay loop powered output for the control of devices such as dampers, extractors or plant and equipment shutdown. The monitored input can used for local power supply fault monitoring or as general-purpose input which allow 2 independently controlled change over relays, relays contact rated at 250V ac @ at 5 Amps (resistive) & 48V dc & 2 amp( resistive) having auxiliary monitored input, followed by Analogue addressable protocol, electronically addressed, approved by LPCB. (AHU Tripping) (supplied with front cover back plate and inbuilt short circuit isolator), complete all as specified and directed.Make:-Ceasefire/Hochiki/LTS/Agni
M&L in replacement for Analogue addressable single relay monitor output to be connected to the loop. The unit incorporates a volt-free relay contact that can be configured as either N/O or N/C, the relay contact is rated to 30 V dc (max), 1 A (resistive load). Approved by LPCB, complete all as specified and directed.Make:-Ceasefire/Hochiki/LTS/Agni
M&L in replacement for Analogue addressable a single relay monitored input to be connected to the loop. Approved by LPCB, complete all as specified and directed.Make:-Ceasefire/Hochiki/LTS/Agni
Supply, installation, testing and commissioning in replacement of LPCB approved beam detector with transmitter and receiver unit having distance range from 5-100 Mtr, automatic signal strength adjustment, automatic contamination compensation, feature of latching on non-latching fault relay. Emitter can be directly powered from Loop or Zone (complete with accessories to make addressable), complete all as specified and directed.Make:-Ceasefire/Hochiki/LTS/Agni
M&L in replacement for single sampling pipe up to 50m in length (still air) Aspirating smoke detector with dock station shall be designed to provide very high sensitivity smoke detection provided by laser based forward light scatter by using 3D3 laser dust discrimination (LDD) technology. Detector should have capability of measurement range (obs/m) 0.03% to 25% full scale deflection (FSD) and 0.0015% to 25% sensitivity resolution by detection principal of laser light scattering mass detection and particle evaluation, complete all as specified and directed.Make:-Ceasefire/Hochiki/LTS/Agni
Supply and laying and fixing in replacement on wall or in trench/ducts, 2 core 1.5 sqmm armoured cable copper conductor including steel saddles, screw for fixing of cable on wall and ducts in PVC heavy duty conduit ISI marked of size 25mm dia complete all as specified and as directed.Make : Havells/Finolex/Plaza Note : Rate of PVC conduit, conduit steel saddle are deemed to be included in the quoted rate.
Supply and laying in replacement of 2 core 1.5 sqmm armoured cable copper conductor in existing conduit (concealed type) complete all as specified and as directed.Make : Havells/Finolex/Plaza
Disconnecsting, dismantling and taking out the non functional microprocessor based upto 8 Zone conventional fire alarm control ( main control panel) of with battery charging circuit, Transformer, power supply unit having provision for Audio indications for FIRE, FAULT, OPEN/SHORT EARTH CIRCUIT & battery set for eight hours continuous back up in case of mains failure. reassembling and testing complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item.
Supply only in replacement of Battery 7 AH suitable for FACP panel complete all as specified and as directed.
Supply only in replacement of PCB suitable for FACP circuit incl wiring kit of existing capacity complete all as specified and as directed.
Labour only tracing out the fault and functiong the microprocessor based upto 8 Zone conventional fire alarm control system by highly skilled trades man, reassembling and testing complete all as specified and directed.
Supply & fixing in replacement fire hydrant landing valve type B ( double head outlet) of 63 mm dia conforming to IS 13039-1991 along with 2 Nos cast iron hand wheel , 2 Nos female Instantaneous outlet, 2 Nos ABS blank cap and chain complete all as specified and directed. Make: Padmini/DSS/Newage.
Supply and fixing in replacement hose box wall mounting type for keeping 2 Nos hose pipe of length 15 meter each, branch pipe,nozzle, coupling etc made out of 18 gauge mild steel sheet size 800mm x 600mm x 250mm , acrylic fronted double door with lock , 2 keys and a break glass recess for Key, painted fire red complete all as specified and directed..Make: Padmini/DSS/Newage.
Supply and fixing in replacement 63 mm dia SS branch pipe with 20 mm nozzle conforming to IS 903 complete all as specified and directed.Make: Padmini/DSS/Newage.
Supply and fixing in replacement 63 mm dia 15 meter long CP hose conforming to IS 636 complete with male and female coupling conforming to IS 903 complete all as specified and directed. Make: Padmini/DSS/Newage.
Supply and fixing in replacement fire hose reel drum 30 m long, as per IS : 3844-1989 with all accessories including gun metal valve 15 mm with nozzzle and fixed on wall. complete all as specified and as directed. Make: Padmini/DSS/Newage
Taking out heavy duty RCC duct 1.2mx0.7mx0.2m weighing 300 kg (approx) (cover from duct for cleaning of mud/stone whichever is their and refixing the duct cover after taking out pipe line and refixing the same of any size and capacity in the duct complete all as specified and as directed.
Taking out heavy duty MS duct cover 1.2m x 0.7m x 0.008m weighing 60 kg approx for cleaning of mud/stone whichever is their and refixing the duct cover after taking out pipe line and refixing the same of any size and capacity in the duct complete all as specified and as directed by Engr-in-charge
M&L for cutting of Hardstanding/road by mannual method upto 1000mm deep and width approx 400 mm for pipe line complete including filling with ready mix/ PCC and making good distrubed surface complete all as specified and as directed.
M&L for boring holes 2 mtr deep (trench less) in soil for under-reamed piles, 250mm dia pipe, getting out and disposal of spoil to a distance of not exceeding 50 mtr and making good distrubed surface complete all as specified and as directed.
M&L for dismantlling joints of flanged pipes in position including removing old gasket, nut ,bolts etc upto size 150mm dia complete all as specified and directed.
M&L for joints of flanged pipes in position including new rubber or fiber board gasket, nut ,bolts washers etc upto size 150mm dia complete all as specified and directed.
Taking up unseviceable CI water main(incl all fitting) with flanged ends incl disconnecting pipes and fittings complete of size 150 mm bore for laying /rerouting of serviceable pipe after cleaning complete all as specified and as directed.
Material and labour for laying of CI pipes of size 150 mm bore with flanged ends centrifugally cast class A in any length laid in trenches/on surface/ over masonary pillar and connection to old or new position complete all as specified and as directed.Make:- Jindal/ kesoram/electro steel). Note: CI fitting /gasket joint will be measured and paid seperately all the dismanted / demolished /taking down materyal shall be removed from site.
M&L in replacement CI special like bend any type radius and angle tapers any type straght bend increacing decreacing single or double branch etc) tee pipe single branch y juction double branch cross(all end flanged of the following size upto 150 mm dia complete all as specified.
Taking out existing unserviceable NRV of size 150 mm bore complete all as specified and as directed.
Suply and fixing in replacement cast iron NRV flanged end of size 150 mm dia with all fitting and accessories . Make:Zoloto or equivalent in Kirloskar/Kartar.
Taking out existing U/S CI sluice valve of any size any pattern up to 150 mm bore complete all as directed.
Supply & fixing in replacement Cast Iron sluice valve of size 80 mm bore class PN-1.6 IS : 14846 with SS spindle, both ends flanged with holes, provision of nuts, bolts, washers, rubber gasket etc. with CI wheel, fixed to CI water mains , and including testing complete all as specified and directed.Make:Zoloto/Kirloskar/Sant
All as per item 38 her -in -before but 150 mm dia bore.
M&L for opening of fire Jokey Pump type 30 LPS for repair and replacement of following unserviceable parts including re-fixing of all the same and testing and commissioning complete all as specified and as directed. (a) Replacement of gun metal impeller. -01 Nos (b)Replacement of gun metal bush -02 Nos (c) Replacement of ball bearing.Make: SKF - 02 Nos. (d) Replacement of oil seal -01 Nos. (e) Replacement of gland -01 Job
M&L for rewinding of burnt Jokey pump motor of capacity upto 30HP, 30 LPS, 3 phase ,415 V, 50 Hz of any make with copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface and water proof jointing for cable 3 core, with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc complete all as specified and as directed.
M&L in replacement for fixing of Single phase preventor VSP 2 auto/manual reset of any size , 415V complete all as specified and as directed. Make:-AE/L&T/SG/Minilec/Motif.
M&L in replacement for MCCB 4 pole 250 amps, 50 KA, of make- Legrand or equivelent of Havells cat Part No IHLFHF0250# / L&T/Standard.
M&L in replacement for MCCB 4 pole 400 amps,50 KA, of make- Legrand or equivelent of Havells Cat Part No IHLLNFBF0400 / L&T/Standard.
M&L in replacement of Power contactor 3 pole Type CN5 50 AC 50 Amp rating complete all as specified and as directed.Make:- Havells Cat part No IHPAA050511/ L&T /Siemen/ABB
M&L in replacement of Power contactor 3 pole Type MNX 70 AC 3 rating 70A. Make:- Havells, L&T Cat part No CS97076 /Siemen/ABB
M&L in replacement for laying of chequered plate MS with minimum thickness 8 mm suitable to take load of 10 ton vehicle for keeping over trench as duct work. Work includes making of angle iron frame to support MS plate suitable width and suitable length, and necessary joinning work like welding complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregate on side face of duct including necessary form work complete all as specified and as directed.
S&F in repair Cast iron foot valve of size 150mm dia heavy duty with necessary fixing arrangement like nut , bolts washer packing sheet etc including taking out existing unserviceable footvalve complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, test point of phosphorous bronze / gun metal of size 75 mmx 75 mm x25 mm, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI medium grade earth lead protection pipe including nessary earth work, complete all as specified and directed. NOTE : Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Bus Bar chamber comprising of 4 Nos Copper strip bus bars air insulated and PVC sheathed capacity 250 Amp for R,Y B phases and 200A for neutral and mounted on PVC insulated with colour coding.
Phase indicating LED lamps (RYB) - 3 Nos Make: AE/Legrand/Havells/ABB
MCCB 160 Amps, 35KA, 4 Pole, 415 V, 50 HZ AC with thermal and magnetic release - 01 No ( for incoming). Make: Legrand/Havells/ABB
MCCB 100 Amps, 25 KA, 4 Pole, 415 V, 50 HZ with thermal and magnetic release - 01 Nos ( for outgoing) . Make: Legrand/Havells/ABB
MCCB 63 Amps, 25 KA, 4 Pole, 415 V, 50 HZ with thermal and magnetic release - 02No ( for outgoing) - Make: Legrand/Havells/ABB
MCB SPN 240V 32A , 10KA , C curve -04, Make: Legrand/Havells/ABB
Automatic star delta starter capacity 60 Hp-01 Nos
On load Change over switch 4 Pole 160 Amp -01 No Make: Legrand/Havells/ABB
Disconnecting, taking out, removing old existing unserviceable underground cable and Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed of size 3.5 core 35 sqmm. Make :- Havells/Polycab/Gloster/Finolex.
Excavation in trenches not exceeting 1.5 Mtr wide and not Exceding 1.5 Mtr in depth and getting out in Hard/Dense soil for laying cables complete all as specified and directed
Returning, filling in including spreading, levelling, watering and ramming in layers not exc. 25 cms complete all as specified and directed
Removing excavated material not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
Supply and fill dry river sand in trenches for cable cushioning complete all as specified and directed .
Supply and laying bricks subclass B designation 75 for cable protection complete all as specified and directed.
M&L for construction of valve chambers with MS cover 3 mm thick of valve pit of size 1200x1200x1200 MM( internal dimensions) including necessary excavation, earth work, 150 mm thick PCC 1:4:8 Type D2 as in foundation, 230 mm th. Brickwork in cement mortar1:4PCC 1:2:4 Type B1 in coping plastering 15 mm thick in cm 1:4, and angle iron frame 50x50x06 mm and locking arrangement including painting with coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed.
M&L for cutting of existing CI pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including necessory excvation and earthwork, dewatering etc, complete all as specified and directed for 50 to 150mm bore of pipes
Supply and fixing in replacement SS Jet branch nozzle suitable for 63mm hose conforming to IS 903. Make: Padmini/DSS/Newage.
Taking out existing unserviceable MS pipe line of size upto 80 mm bore complete all as specified and directed.
Supply, laying , jointing, welding & testing in replacement of MS pipe ( Heavy duty Class 'C') including fitting as required of following sizes laid in treches or laying on floor for connecting to various accessories and to connect outgoing air pressure main complete all as specified and as directed. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate of this item
20 mm bore
25 mm bore
50 mm bore
80 mm bore
S&F in replacement Ball valve brass with iron handle screwed both ends for iron pipe and fixed of the following sizes :- Make-Zoloto/Leader/Castle
Dia of pipe 20mm
Dia of pipe 25mm
M&L for sub main wiring concealed completely with 4 Sqmm wire (nominal area) (PVC insulated, multi stranded) FRLS copper conductor cable unsheathed and include PVC conduit with all fittings, medium grade, ISI Marked and PVC insulated FRLS copper conductor cable of size 4 sqmm as earth wire , connected to common earth dolly suitable for mounting modular switches includind fixed modular metal flush boxes and modular face plate complete all as specified and as directed.Two runs of 4 sqmm and one run of 04 sqmm including PVC conduit shall be measured as one RM The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate complete all as specified and as directed.Make of cable:- Finolex/Havells/Kallinga, PVC conduit - Presto Plast/Kalinga/Plaza
Note: 1. Part of the work will be carried out inside false ceiling the cost of labour for removing and re fixing of false ceiling will be deemed to be included in the quoted rates. Tenderer is advised to visit site of work before quoting his rates. Quoted rate is deemed to be inclusive of all this. The work shall be executed as approved by GE.
AMIR ENTERPRISES
Continental Engineers and contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .