Executive Engineer, ED-3rd Srinagar
Office of Executive Engineer, ED-3rd Srinagar
Shifting of 630 kVA Substation at Noorbagh Baghwanpora near the Gate of SMC Marriage Hall falling under the jurisdiction of ESD Nawakadal, ED 3rd (Turnkey Basis)
2025_PDD_298249_1
ED-III /29 of 2025-26, Dated - 15-12-2025
Open Tender
Electrical Works
Turn-key
15 days
Office of Executive Engineer, ED-3rd Srinagar
Refer SBD, Technical Specification, Drawings
7 documents required · 7 mandatory
₹200
Executive Engineer, ED-3rd Srinagar
₹7,560
1 Jan 2026
15 Dec 2025
27 Dec 2025
15 Dec 2025
26 Dec 2025
18 Dec 2025
18 Dec 2025 - 25 Dec 2025
Shifting of 630 kVA Substation at Noorbagh Baghwanpora near the Gate of SMC Marriage Hall falling under the jurisdiction of ESD Nawakadal, ED 3rd (Turnkey Basis).
Supply, Installation, testing and commissioning (including loading/ unloading/ carriage from Divisional store to site) of S.T. poles 9.0 Meter long swaged Type conforming to ST 410 SP-33, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
Supply, Installation, testing and commissioning (including loading/ unloading/ carriage from Divisional store to site) of S.T. poles 8.0 Meter long swaged Type conforming to ST 410 SP-15, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 15). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
Supply,installation, testing and commissioning of Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arrestor Set Heavy duty with Plymer Housing, Station type conforming to IEC-99-4 Capable of withstanding Maximum continuous operating voltages (M.C.O.V)
Supply, installation, testing and commissioning of 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) conforming: IS-2544, IS: 5340 (Part-III) and SS: 9921 (Part-I -V)
Supply, installation, testing and commissioning of 11 KV Horn, Gap (fuse 3-phase 200A) as per Relevant IS.
Supply, laying, installation, testing and commissioning of 400 mm² Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type including lugs/thimbles/Clamps
Supply and fixing of G.I Pipe of 150 mm dia 2 mtr long for Pole Butts (6") along with cement concreting
Supply, fabrication & installation of GI Channel/Angle/Flat of sizes including clamps for 1. L.A Set/G.O Set/Horn Gap 2. Transformer Pad/G.I Channel Bedding
Supply, installation, testing and commissioning of 11KV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply, installation, testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing and laying of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Supply,installation, testing and commissioning of DLT Fuse Set for Distribution Transformers (Customised) as per KPDCL Drawing no. CE/P&P/DRG/2023/LTFS/001 adjustable
Providng and laying of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts, including baby insulators, refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply and fixing of Danger Plate With Clamps as per Standards wih writing in English & Urdu.
Supply and fixing of Wedge Connectors/PG Clamps
Supply and fixing of Anti Climbing devices(GI Barbed Wire (12 SWG)
Supply and fixing of Nuts and Bolts full thread of sizes Galvanized as per IS
Providing and painting of poles with single coat of red oxide an two coats of Aluminum Paint
Supply, laying, installation, testing and commissioning of 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
Supply, laying, installation, testing and commissioning of 70 mm² AB Cable (3x70+1x16+1x50 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
Supply and fixing of Suspension/Tension Clamp with eye hook along with pole Collar/clamps
Shifting (Dismantling & re-erection, Testing and Commissioning-Integration with system) of 630 KVA Distribution Transformer from current site to Proposed Site including carriage, transportation, loading, unloading and integration with system by way of providing Clamps/Jumpers/necessary items required for commissioning.
Dismantling of old Substation Structure along with damaged Lineman Hut with door/window, wooden frame and Tin roof, Stones/Brics complete and carriage of same to Divisional Stores
Dismantling of old Wooden Crosses, Link set, DO Set, damaged LA set and transporting same to Divisional Stores including carriage, transportation, loading, unloading.
Dismantling of old PCC Poles and transporting same to Divisional Stores including carriage, transportation, loading, unloading.
Providing of material and laying of Cement bottoming of poles (1:2:4 Mix as per REC Standards 0.40 M3 per Pole)
Providing of material and laying of Cement bottoming of poles (1:2:4 Mix as per REC Standards 0.48 M3 per Pole)
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Combineapprovedkpdcl.pdf
Other Document • 28.39 MB
BOQ_966722.xls
BOQ • 0.31 MB
SBD29.pdf
Tender Documents • 0.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .