Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹10.0 L+₹79,399 (8.59%)Rejected-Finance | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not having appropriate category as per NIT criteria |
Tender Value
₹9.4 L
EMD Value
₹18,800
Closing Date
5 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander
HQ 137 Works Engrs PIN 914137 C O 99 APO
SPECIAL REPAIR REPLACEMENT TO EXTERNAL ELECTRIFICATION HT LT OH LINES AND UG CABLES AT ZAKHAMA MIL STN
2021_MES_431155_7
8544/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Zakhama
Class E and Category b(ii)
2 documents required · 2 mandatory
₹500
AGE I Zakhama
₹18,800
10 May 2022
12 Feb 2022
7 Mar 2022
12 Feb 2022
5 Mar 2022
19 Feb 2022
60 days
Amount
Dismantling undersize/defected cross arms of M.S. channel or angle of any sections complete all as specified and as directed.
Materials and labour for cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Dismantling of unserviceable insulator of any size/type, complete all as specified and as directed.
Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade confirming to IS-2486 complete all as specified and as directed.
Supply and fixing shackle type Porcelain, vitreous, white, brown or green insulator of size 75mm hieght, 90mm dia (maximum), including galvanised mild steel straps of section 31 x 3mm , washers, insulator bolts of 12mm dia, washers and nuts, suitable for working pressure 1100 volts grade complete all as specified and as directed.
Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed.
Material and labour for shifting of serviceable step down O/D distribution transformer of capacity 250KVA including its panel board from one site to another site (distance not more than 4KM) by disconnecting all HT & LT connections and re-installing the same at new location by providing new PCC foundation of suitable size and including making all cable connection, earth connection etc and testing complete all as specified and as directed. Note:- (a) Shifting must be perform carefully. Any damage to the transformer will be realized from contractors dues. (b) Cost for PCC foundation shall be measured and paid separately under respective item. (c) Cost for handling and transportation for shifting of transformer shall be inclusive in quoted rates.
Supply and fixing and connecting single pole zinc oxide (gapless surge type) heavy duty station class, self supporting outdoor type lightning arrestor having rated voltage 11KV (RMS) discharge current 30KA suitable for rated system voltage of 12KV supply system with maximum continuous operating voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resister made of zinc oxide in hermetically sealed container complete with metal base insulator and suitable terminals for ground connection and pressure relieving arrangement and including taking down old unserviciable lightning arrestor complete all as specified and as directed.
Supplying, Laying connecting & testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor) of size 16 Sqmm, 2 core, 1100 Volts(Earthed) grade, confirming to IS-7098 (Part-I) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item.
Supplying, Laying connecting & testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3 core, 11000 Volts(Earthed) grade, confirming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs including taking down old unserviciable existing HT UG cable complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item.
Dismantling of old unservicable/damaged stay assembly embedded in concrete including demolition of PCC upto ground level and removing unserviceable materials from site of work complete all as specified and as directed.
Material and labour for Stay assembly complete with all accessories as shown in electrical plate No. 1 of SSR Part-I (loop type insulator, stay clamps, excavation and concrete shall be measured separately) diameter of stay rod in 16mm complete all as specified and as directed.
Material and labour for restringing, tightening of loose/broken ACSR conductor of any size and type, maintaining standard sag including binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc on HTover head lines complete all as specified and as directed.
Supply and fixing HT 11 KV (Earthed) grade cold shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. Note:- Taking out of existing cable, cutting faulty ends if required are deemed to be included in the quoted rates.
Supply and fixing framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-410 Gde E-250 quality A complete all as specified and as directed.
Supply and fixing mild steel plates, plain or chequered, 5mm thick or over in thickness, including cutting and making in to sizes conforming to Fe-410 Gde E-250 quality A complete all as specified and as directed.
Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
Dismantling of existing unserviceable/undersize ACSR conductor (of any size) , jumper from overhead line, removing unserviceable materials from site of work complete all as specified and as directed.
Materials and labour for Aluminum conductor steel reinforced (ACSR) conductor as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed.
Material and Labour for HT cable route indicator of 80mm dia CI plate duly engraved (cable MES HT 11 KV), bolted with 40x6mm flat MS angle iron member of height 0.6 mtr and embeded in PCC (1:3:6) Type C-2 (using 40 mm graded aggregate) of size 30cm x 30cm x 60cm block (30Ccm below groung and 30cm above ground) including necessary earthwork complete all as specified and as directed.
Supply and laying of GI tubing 80mm bore light grade with fittings laid in trenches or for road crossing for protection of underground LT/HT cables complete all as specified and as directed.
Materials and labour as in repair for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised Strip of 32x6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Materials and labour as in repair for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Supply and fixing as in repair for Danger notice plate of 25x20cm size and 1.6mm thick mild steel sheet, vitreous enamelled white, with letters(Local & Hindi language), figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT pole complete all as specified and as directed.
Excavation in trenches n. exc 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed.
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of under ground cable including spreading and punning down complete all as specified and as directed. Note:- Punned down thickness shall be measured.
Supply, laying and spreading of 40mm graded course aggregate complete all as specified and as directed.
Materials and labour for 10 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
Material and labour for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping and like including necessary formwork complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in coping and like including necessary formwork complete all as specified and as directed.
Materials and labour for brick protection cover to underground cables with sub class ‘B’ brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed.
PERFECT BUILDERS AND SUPPLIERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .