Executive Engineer Elect. Div PWD B and R Hisar
Executive Engineer Elect. Div PWD B and R Hisar
SPECIAL REPAIR FOR ADMN. BLOCK NO. 1 IN MINI SECTT. AT SIRSA (PDG. S/R TO E.I ONLY).
2022_HRY_233864_1
Elect-GGN/Elect-HSR/100349
Open Tender
Electrical Works
Works
120 days
Hisar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹25,930
12 Nov 2022
12 Aug 2022
29 Aug 2022
12 Aug 2022
26 Aug 2022
12 Aug 2022
Amount
Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge. (HSR 20.71)
Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. (HSR 20.72)
COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED (HSR 23.5) 23.5.1: Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. (HSR 23.5.1) Group C (HSR 23.5.1.3)
Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required. (HSR 23.5.4) Group C (HSR 23.5.4.3)
Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling, including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required . (HSR 23.5.5) Group C (HSR 23.5.5.3)
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. (HSR 23.5.6) 1 run of Size 1.50 Sqmm(1/1.40mm). (HSR 23.5.6.1)
1 run of Size 4 Sqmm(1/2.24mm) (HSR 23.5.6.3)
FITTING AND ACCESSORIES (HSR 23.8) Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. (HSR 23.8.1) Switch 5 amp. on existing sheet.(HSR 23.8.1.1)
Wall socket 5 amp on existing sheet. (HSR 23.8.1.2)
15 amp. switch on existing sheet. (HSR 23.8.1.3)
6 pin 15 multi socket on existing sheet (HSR 23.8.1.4)
Call bell 220/230 volts musical type (HSR 23.8.1.6)
Bakelite angle/straight button holder large size (HSR 23.8.1.12)
Socket size rotary step type Electronic regulator for A.C. ceiling fan. (HSR 23.8.1.13)
Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. (HSR 23.8.2) 5 mm thick (HSR 23.8.2.1)
Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required. (HSR 23.12)
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required. (HSR 23.20)
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. (HSR 23.22) Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. (HSR 23.22.1) TRIPLE POLE MCCB 200 to 250 Amp, 25 KA (HSR 23.22.1.5)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- (HSR 23.22.5) 6 amp. to 32 amp Single Pole. (HSR 23.22.5.1)
40 amp to 63 amp. MCB's FOUR POLE. (HSR 23.22.5.8)
Non Schedule Items:- Supply and Erection of 40 W LED Batten 4' long with aluminium base heat shink complete of Dura Batten 50000 Bussiness Hours, 4600 Lumens. complete with all accessories and labour to complete the job upto the entire satisfaction of Engineer-in-charge of the work. (Make:- Havell's/ Bajaj/ wipro/ Philips/ Hallonix).
Deduct - Deduct amount for Dismentled Ceiling Fan
Deduct -Deduct amount for Dismentled Exhaust Fan
The Darba Kalan Shila Coop L/C Society Ltd.
Rajesh Electric Works
Shri Mahdev & Company
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .