Supply installation testing and commissioning of fire detection and alarm system at different buildings of Calcutta Pavlov Hospital
2019_WBPWD_250242_1
WBPWD/EE-I/CKHED/NIT-28/19-20
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Calcutta Pavlov Hospital
as per NIT
4 documents required · 4 mandatory
₹50,000
EE CKHED P12 CIT Road 1st floor Kolkata 700014
19 Mar 2021
25 Oct 2019
4 Dec 2019
25 Oct 2019
2 Dec 2019
2 Nov 2019
31 Oct 2019
Amount
The panel shall have in-built rectifier, Loop cards, interface card for connecting external serial printer, 4 line, 40 charecter/line alphanumeric LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working or capable of operating the system for 2 hours during alarm condition, with integral battery charger complete as required. The panel shall have extra loop card to serve as stand by in case of burntout or malfunctioning of any operating loop cards. The FACP shall be capable of being networked with other similar FACP located at different part of the premises through ethernet (LAN). The panel should have necessary Ethernet card installed in it for bidirectional communication with 3rd party BMS/Scada and 3rd party public address system. All necessary memory map (incl. device address) should be provided. Minimum 4 potential free spare contacts should be provided with the panel. The system must be preloaded with licenced software. ( Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls / Securiton).
2 Loops panel with one additional loop, expandable upto 4 Loops.
Supply, Installation, Testing & Commissioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detectors sensor with decentralize intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard. [Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost].(Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls / Securiton)
Supplying, installation, testing and commissioning of soft Addressable Heat Detector (Fixed temperature cum rate of rise) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard [Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for each addressable devices (Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost]. (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Contros/ Securiton )
Supply, Installation,Testing & Commisioning of soft Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo/ Morley / System Sensor / Johnson Controls / Securiton ).
Supply, Installation, Testing & Commissioning of soft Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base ( VDS / UL / FM / ULC approved) . (Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls / Securiton ).
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL / FM / ULC approved) having red coloured LED lamps including connections etc.( Approved Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls/ Securiton ).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / Polycab / RR Kabel) with 20 mm NB PVC rigid conduit pipe(Make: Precisson-Medium) on the surface of the wall.
Supply & Laying of 2 Core 2.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex / Polycab / RR Kabel ) with 20 mm NB PVC rigid conduit pipe(Make: Precisson/Polycab-Medium-FR) on the surface of the wall.
NOTE : 1. The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
TESTS: 1.The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system under active monitoring of OEM. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. Before taking up the work necessary building drawing/ floor plan with layout should be prepared and to be approved from the fire safety Cell of PWD according to the prevailing fire safety policy. After commissioning, necessary testing to be done in presence of fire safety cell.
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
NILEX FIRE PROTECTION SYSTEMS
SAFE GUARD (INDIA)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .