Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 CrAccepted-AOC 4 243A LAKSHMI NAGAR ACHIPATTI PANCHAYAT POLLACHI COIMBATORE TAMILNADU 642002 | COIMBATORE | TAMIL NADU | 642002 | ₹1.7 Cr Quoted ₹1.8 Cr | 1 | Accepted-AOC 1st Lowest |
| 2 | 2₹1.8 Cr+₹2.4 L (1.39%)Rejected-AOC NO 71 N1 5TH CROSS ARANI HOUSE ROAD KILODAPPAMUND STONE HOUSE HILL OOTY THE NILGIRIS DISTRICT 643 002 | THE NILGIRIS | TAMIL NADU | 643002 | ₹1.8 Cr+₹2.4 L (1.39%) | 2 | Rejected-AOC 2nd Lowest |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-Encumbrance certificate not uploaded properly |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
27 Dec 2023, 3:00 pmClosed
SPECIAL CHIEF ENGINEER
SPECIAL CHIEF ENGINEER, PWD, BUILDINGS CONSTRUCTION AND MAINTENANCE CIRCLE, COIMBATORE
Construction of Additional Steam Laundry building for modernization of equipments in Coimbatore Medical College Hospital at Coimbatore District.
2023_PWD_396719_1
29BCMCBE28112023
Open Tender
Civil Works - Buildings
Lump-sum
275 days
Coimbatore Medical College Hospital at Coimbatore
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹1 L
23 Jan 2024
6 Dec 2023
27 Dec 2023
6 Dec 2023
27 Dec 2023
6 Dec 2023
Amount
EARTH WORK EXCAVATION for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift upto 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
CEMENT CONCRETE 1:5:10 [One Cement, Five Crushed Stone Sand and Ten hard broken stone jelly] using 40 mm gauge hard broken granite stone jelly for FOUNDATION including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.
Supplying and filling in foundation and basement with Filling Crushed Stone Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement with CONVEYED GRAVEL not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
BRICK WORK in Cement Mortar 1:5 [One Cement and Five crushed stone Sand] using best quality chamber burnt Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].
For Foundation & Basement
BRICK WORK in Cement Mortar 1:6 [One Cement and Six crushed stone Sand] using best quality Fly Ash Bricks of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. [Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost].
For Foundation and Basement
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as COLUMN FOOTINGS, COLUMN PEDESTALS, PLINTH BEAMS, GRADE BEAMS, STAIRCASE STEPS, etc., which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. [Payment for centering shall be given after the concrete is laid].
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height For plane surfaces as detailed below , in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid).
RCC FLOOR SLAB, ROOF SLAB, RECTANGULAR BEAMS, ELL BEAMS, LINTELS, LANDING WAIST SLAB, CONAPY SLABS BED BLOCKS etc.,
FOR PLANE SURFACES SUCH AS VERTICAL SLAB, SIDE SLABS OF BOXING, VERTICAL DROPS, FACIA, VERTICAL WALL, ETC.
FOR PLANE SURFACES SUCH AS RECTANGULAR OR SQUARE RCC COLUMNS, SUNSHADES, TOP AND BOTTOM SLAB OF RCC BOXING, etc.,
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/ms and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retad setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu'm') 7670 kg. of cs sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
Supplying, fabricating and placing in position MILD STEEL / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. [Contractor has to make his own arrangements for the supply of steel and binding wire].
CEMENT CONCRETE 1:5:10 [One cement, Five CS sand and Ten hard broken stone] using 40 mm gauge hard broken jelly for FLOORING including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. [The rate is inclusive of necessary planking for panelling wherever necessary and complete complying with standard specification and as directed by the departmental officers.
PLAIN CEMENT CONCRETE 1:2:4 [one cement, two crushed stone Sand and four hard broken stone jelly] using 12 mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. [In Ground Floor].
Supplying and fixing in position best approved of BIS quality of following dia PVC RAIN WATER DOWN FALL PIPES having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
110mm dia (One Floor)
160mm dia (Two Floor)
DADOOING walls with printed design colour glazed tiles of size 300 mm x 600 mm x 10 mm sizes set in Cement Mortar 1:2 [One Cement and Two Crushed Stone Sand] 10 mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg/m2 neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for Staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100x100x6mm MS base plate encased in the base concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges etc., complete.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Openable Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
Supplying and fixing M.S. Grill of approved design for open courtyard, grill, grill works to doors and window opeings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
Supplying and erecting Manually operated pull and push type rolling shutter with ISI make of approved Gear operated type (from 8 m2 to 12 m2 area) and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc..
Painting NEW IRON works such as steel doors, windows, ventilators, window bars, balustrades etc., with TWO COATS of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. [The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.]
Manufacturing supplying and fixing of STEEL DOOR [SINGLE LEAF] with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x6mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of hinges in case of single leaf and 6nos. of hinges in double leaves shutter to be provided 6nos. of holdfasts 120 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts
2nos. one at the top and the other at the bottom are provided 1no. Aldrop is provided incase of double leaf door at lock rail section in the door in single leaf door, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter to conceal the gap between the two shutters at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specifications and as directed by the departmental officers.
Providing ANTI-TERMITE treatment to soil adjacent under building foundation, plinth periphery of the building by applcation of chemicals of ISI 6313-1981 part I to IV in stages to suit the progress of work as per the detailed specification (Measurements taken for the plinthe area for the purpose of payment) including breaking of termite mounds, making holes with clow bar, closing the holes after the treatment and incliding cost of chemicals, labour charges, transport and storing etc., complete complying with the standard specification and as directed by the departmental officers.
Stage.I. spraying anti- termite treatement chemicals solution for foundation concrete surface laying the foundation concrete bottom and sides of the foundation. Stage.II. Spraying anti-termite chemical solution to the grade beam level, spraying for the grade beams, brick, masonry in superstructure in contact with the back fill earth. Stage.III. Spraying anti-termite treatment, chemicals solution on sand for the flooring before laying the flooring zone, Treatment has tobe carried out by making crow bar holes at an interval of 12" to a depth of 8" on the sand filling in basement and after levelling operation is over. Stage.IV. Spraying anti-termite treatment chemicals solution around the building (out side) by making crow bar holes at an interval of 12" to a depth of 8" in the periphery of building and chemical poured inside the holes and closed after the treatement.
SPECIAL CEILING PLASTERING and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers.
PLASTERING with Cement Mortar 1:5 (One cement and Five p.sand), 12mm thick mixed with Bonding agent Cebex112, Zydex -Zycrete 2X or other Equalent compound conforming to BIS at 200ml of One cement bag (50kg) for increased workability and air entrainment used finishing in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
Providing GRANOLITHIC FLOOR finish of following thickness with Plain Cement Concrete 1:2:4 [One Cement, Two Crushed Stone Sand and Four Aggregate] using 10 to 12 mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc., complete complying with standard specification and as directed by the departmental officers. [The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers].
40mm thick
25mm thick
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including through scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., through scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
WEATHERING COURSE concrete in brick jelly lime concrete using broken brick jelly of size 20 mm uniform gauge in pure slaked lime [no sand to be used] to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
In First Floor
In Second Floor
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three C.S Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, UPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. INTERNAL WATER SUPPLY - ABOVE GROUND LEVEL
20mm dia UPVC Pipe
40mm dia UPVC Pipe
Supplying and fixing in position UPVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the UPVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The UPVC specials should be got approved by the Executive Engineer before use on works).
20mm dia Elbow
20mm dia Tee
20 x 15 mm dia Reducer
20 x 15 mm dia Reducer eblow
20 mm dia Union
40mm dia Union
Supplying and fixing in position PVC SPECIALS of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. [The PVC specials should be got approved by the Executive Engineer before use on works].
75mm dia PVC Elbow
75mm dia PVC Elbow with Door
75mm dia PVC Tee
110mm dia PVC Elbow
110mm dia PVC Bend
Supplying and fixing in position first quality and approved variety of Gun metal GATE VALVE with BIS make of the 20mm dia including cost of shellac, thread balls, etc., complete complying with standard specifications [for both internal and external water supply arrangements]. The valves to be used on work shall be got approved by the Executive Engineer before use on work.
40mm dia
Supplying and fixing in position 15 mm dia CP SCREW DOWN TAP [heavy duty] of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. [Taps should be got approved by the Executive Engineer before use on the works].
Supplying and fixing of PVC ready made WATER TANK 2000 litres of best and approved quality with ISI specification and having inlet,outlet, overflow and clearing pipe arrangements and labour charges for fixing in position with all necessary accessories and transporting at site of work etc., complete complying as directed by the departmental officers.
Supplying and fixing in position best quality and approved make Indian made WHITE GLAZED EARTHERNWARE WASH HAND BASIN of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Construction of INSPECTION CHAMBER of clear sizes 900 X 900mm including earth work excavation, CC 1:5:10 of 10cm thick and brick work in cement mortar 1:5 [one cement and five cs sand] using best quality of Fly Ash Bricks of size 23 x 11 x 7cm with plastering with cement mortar 1:3 [one cement and three p. sand] 12mm thick to inner and outer sides and wearing coat 1:3:6 [one cement, three cs sand and six aggregate] 15cm thick and covered with precast slab 5cm thick etc., complete complying as directed by the departmental officers as per standard specification.
Supplying and fixing in position best quality PVC SOIL / WASTE PIPES of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry. RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. [The PVC pipes should be got approved by the Executive Engineer before use on works]. The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid.
160mm dia
110mm dia
75mm dia
50mm dia
M/s. LJK Constructions
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .