Tender Value
₹5.3 Cr
EMD Value
₹10.7 L
Closing Date
4 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECT.GEN.
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB(available in GCC), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Calculation of required minimum average annual contractual turnover- V = Rs. 53437005, N= 9 months = 0.75 year, V/N= 53437005/0.75 = Rs. 71249340, V is less than V/N, Hence, required minimum average annual contractual turnover = Rs. 53437005
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note: (1) Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate
Defination of Similar Work :- Electrification / Rewiring of Service or Residential building / Yard / HT / LT substation work / HT / LT cable work / street lighting / platform or building lighting management / circulating area Lighting / Electrical overhead power supply work / Electrical pump work etc.
13 conditions · 7 needing a document upload
The registration of contractors working under Railway departments with ESIC is mandatory (if applicable as per current Law / Act)
In case a tenderer is participating as Sole Proprietor in a tender, it is mandatory for him to submit an undertaking on suitable stamp paper to this effect clearly mentioning PAN number also along with tender document at the time of submission of tender.
The tenderer may submit scanned copy of partnership deed if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor shall ensure all precautions during digging work close to Rly signaling, telecom electrical cables etc. Penalties to be imposed for damages to any cable as per Railway board letter no. 2021/Tele/5(2)/3- Part(1)/(3425647) dtd 12.06.2023
Electrification work in connection with Mobility improvement and capacity augmentation in Igatpuri - Asvali section (26.00 Km) and Asvali - Nashik section (25.61 Km) by providing Automatic Block Signalling for handling Kumbh Mela 2027 traffic.
BSL-L-W-T-25-2026
BSL-L-W-T-25-2026
Open
Works - General
9 Months
Jalgaon, Maharashtra
₹0
₹10.7 L
4 May 2026
9 Apr 2026
20 Apr 2026
284 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,61,63,104 | ||
| — | Breakup | for details. | — | ||
| Supply and fixing of double pole upto 25A 30mA RCCB/RCBO in already erected MCB DB as per specification | — | — | — | 2,20,000 | |
| — | Breakup | for details. | — | ||
| Supply and fixing of double pole 40A 30mA RCCB/RCBO in already erected MCB DB as per specification | — | — | — | 2,50,000 | |
| — | Breakup | for details. | — | ||
| Supplying, fixing and commissioning 2 pole RCBO 63A, with overcurrent, rated short circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 5,06,700 | |
| — | Breakup | for details. | — | ||
| Supplying, fixing and commissioning 4 pole RCBO up to 25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indications per specification | — | — | — | 4,79,300 | |
| — | Breakup | for details. | — | ||
| Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 4,97,000 | |
| — | Breakup | for details. | — | ||
| Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short- circuit breaking capacity (10 kA) and earth leakage protection, with 30 mA sensitivity and short circuit and earth leakage trip indication as per specification | — | — | — | 5,61,700 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 70%-30% Lighting panel consisting of the following items: One No. of 3-pole power contactor MNX 70 (Make : L&T, BCH, Siemens), One No. of Electronic timer 120 DT( Make : L&T, BCH, Siemens), One no. of 3 pole MCB 63 A, Two nos. of terminal 4-way ( Make : Indigenous ), One No. of Auto / Manual switch (Make : Indigenous), One No. of push to on switch ( Make: Indigenous ) ,One no. of MS BOX with powder coated paint size500mm x 350mm x150mm(make : Indigenous), One no. of plug type relay 2CO-230V ( Make : PLA, LA, L&T ) with fixing material and fixing charge per panel. | — | — | — | 73,524 | |
| — | Breakup | for details. | — | ||
| SETC ofOutdoor type LT panel as per IEC 61439 with double door powder coated consisting of 2 Nos x 125 A MCCB as I/C & 1 Nos x 125 A 4P Automatic Transfer switch, 2 Nos x 125 A 4P MCCB as O/G along with Digital timer with microcontroller based, ELR with CBCT for each MCCB, Power quality analyser, 3 ph Energy meter, Multifunctional meter, indication lamp, Copper Busbar and all other associated accessories. All MCCB are Microprocessor based (completely wired with suitable communication cable to fetch data from each compartment functional Unit (ACB/MCCB/SFU etc) / Multifunction Meter) | — | — | — | 21,33,188 | |
| — | Breakup | for details. | — | ||
| PVC insulated & sheathed 3 core flexible copper cable size 0.75 sq mm | — | — | — | 64,000 | |
| — | Breakup | for details. | — | ||
| Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material | — | — | — | 16,816 | |
| — | Breakup | for details. | — | ||
| Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 25 to 50 sq mm., with necessary material | — | — | — | 20,360 | |
| — | Breakup | for details. | — | ||
| Provision of Cable Jointing Kit suitable for 16/25 sqmm cable | — | — | — | 78,608 | |
| — | Breakup | for details. | — | ||
| Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification | — | — | — | 52,352 | |
| — | Breakup | for details. | — | ||
| Supply of LT XLPE Armoured 4 Core 50 Sqmm Aluminium cable as per relevant IS. | — | — | — | 11,14,400 | |
| — | Breakup | for details. | — | ||
| Supply of 4 core 25 sqmm armoured XLPE Cable. | — | — | — | 5,85,600 | |
| — | Breakup | for details. | — | ||
| Supply of 4 core 16 sqmm armoured XLPE Cable. | — | — | — | 5,23,600 | |
| — | Breakup | for details. | — | ||
| Trenching & refilling of LT/HT/ Various sizes of PVC / XLPE cables- Along the Road (Size - 900mm x 300mm) | — | — | — | 10,55,000 | |
| — | Breakup | for details. | — | ||
| Digging of cable trench 300/450 mm x 1000 mm in RCC/PCC/hard soil & refilling as per specification and requirement at the site. | — | — | — | 7,36,000 | |
| — | Breakup | for details. | — | ||
| Transportation, Laying, Installation, terminating, testing and commissioning of LT/HT cable of sizes 10 sqmm to 400 sqmm in existing trench, pipe or on structure. | — | — | — | 2,10,000 | |
| — | Breakup | for details. | — | ||
| Erection,testing and commissioning of cables other than trench i.e.Wall/Truss including clamp, GI wire and hardware | — | — | — | 72,000 | |
| — | Breakup | for details. | — | ||
| Supply & laying of GI pipe Class B, ISI marked under road /Clamping with erecting pole or wall as per technical specification & drawing for passing cable. | — | — | — | 20,200 | |
| — | Breakup | for details. | — | ||
| Supply,installation, testing & commissioning of HDPE Pipe 110 mm Nominal Dia as per IS-4984-1995. | — | — | — | 1,50,000 | |
| — | Breakup | for details. | — | ||
| Supply and laying of RCC half round pipe 150 mm ID & 1 mtr length. | — | — | — | 6,43,304 | |
| — | Breakup | for details. | — | ||
| Supply and laying of RCC Hume Pipe of size 6"(150mm) dia 2 mtr. Length. | — | — | — | 27,180 | |
| — | Breakup | for details. | — | ||
| Supply, erection of RCC Type cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. | — | — | — | 69,860 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of RCC warning cover of size 18" X 7"X1.5" in an approve manner | — | — | — | 11,480 | |
| — | Breakup | for details. | — | ||
| Supply, fabrication, fixing and erection of MS Work of miscellaneous size and for cable tray etc. including painting complete. | — | — | — | 42,800 | |
| — | Breakup | for details. | — | ||
| Supply, fabrication, laying welding and connection of GI Flat of size 25x3 mm from earth pit with GI nut Bolt suitable size. | — | — | — | 45,600 | |
| — | Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of maintenance free earth as per RDSO specification no. RDSO/PE/SPEC/ PS/0109-008(REV '0') with improved earthing enhancing compound and exothermic welding | — | — | — | 4,20,364 | |
| — | Breakup | for details. | — | ||
| Supply of Digital Megger 500 V. | — | — | — | 1,69,800 | |
| — | Breakup | for details. | — | ||
| Supply of Digital Clamp on Earth Tester. | — | — | — | 7,04,808 | |
| — | Breakup | for details. | — | ||
| Supply of Digital Clamp on Meter (Tong Tester). | — | — | — | 49,936 | |
| — | Breakup | for details. | — | ||
| Supply of Aluminium telescopic ladder, heavy duty with holding rubber, foldable with equal steps, 12 to 13 Feet height with push button type system ladder | — | — | — | 55,272 | |
| — | Breakup | for details. | — | ||
| Analog Earth Tester, 4 terminal (Dual Range), metal Body, and Rated Ohms 0-10-100 Ohms, as per IS Specification 9223/1989 suitable for measuring Earth Resistance along with accessories -- 4 Nos. M.S. spikes, (Not less than 15 mm diameter and 750 mm in length with suitable terminal in one end and tapering at the other end). -- 4 Nos. reels of flexible wire, hammer, 1 No. high quality canvas bag/carrying case. | — | — | — | 29,676 | |
| — | Breakup | for details. | — | ||
| Supplying and erecting metal clad changeover switch 2 pole, 240 V, 32A erected on provided angle iron/GI frame and duly connected with suitable wire leads complete as per specification. | — | — | — | 6,708 | |
| — | Breakup | for details. | — | ||
| Supply of Insulation paint and painting of Octagonal poles / tubular poles/High Mast with 03 coats of insulation paint so as to achieve 05 KV insulation. The work also includes cleaning and scrubbing of pole before application of paint. Upon testing no leakage current should be found upon the painted surface | — | — | — | 94,000 | |
| — | Breakup | for details. | — | ||
| Supply of Insulation tape and application of the insulation tape on Octagonal poles / tubular poles/High Mast so as to achieve 05 KV insulation. The work also includes cleaning and scrubbing of pole before application of paint. Upon testing no leakage current should be found upon the painted surface. {1 Per Unit = 1 Roll of 5.0 CM (Width) x 33 M (Length)} | — | — | — | 10,420 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of Panel mounted (96 x 96 mm) Earth leakage relay for current range (30mA- 30A), 240-415 VAC/DC, 1 C/O (Pre-alarm) + 1 C/O (Fault) | — | — | — | 2,59,740 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of DIN mounted earth leakage relay for current range (30mA- 30A), Auto/Manual rest. | — | — | — | 2,37,300 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type A & AC Current, 38 mm ID & current range (30mA- 30A). | — | — | — | 27,180 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type A & AC Current, 57 mm ID & current range (30mA- 30A). | — | — | — | 36,740 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type A & AC Current, 70 mm ID & current range (30mA- 30A). | — | — | — | 41,700 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type A & AC Current, 92 mm ID & current range (30mA- 30A). | — | — | — | 45,660 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type A & AC Current, 120 mm ID & current range (30mA- 30A). | — | — | — | 47,640 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type A & AC Current, 210 mm ID & current range (30mA- 30A). | — | — | — | 89,760 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type AC Current, 38 mm ID & current range (30mA- 30A). | — | — | — | 20,360 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type AC Current, 57 mm ID & current range (30mA- 30A). | — | — | — | 22,780 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type AC Current, 70 mm ID & current range (30mA- 30A). | — | — | — | 24,100 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type AC Current, 92 mm ID & current range (30mA- 30A). | — | — | — | 32,240 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of CBCT (Moulded case) for type AC Current, 120 mm ID & current range (30mA- 30A). | — | — | — | 37,400 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of Rectangular CBCT (Moulded case) for type AC Current, 300 x 50 mm ID & current range (30mA- 30A). | — | — | — | 1,79,300 | |
| — | Breakup | for details. | — | ||
| Supply, Erection, Testing & Comissioning of Rectangular CBCT (Moulded case) for type AC Current, 350 x 150 mm ID & current range (30mA- 30A). | — | — | — | 2,18,020 | |
| — | Breakup | for details. | — | ||
| SETC of Earth Leakage Current monitoring relay of power supply 230 V AC, Frequency 50 - 60 Hz, True RMS measurement, confirming to IEC 60947 - 2, along with core balancing current transformer, 30 mA - 30 A dia 35 mm. Make SELEC Model No. 900ELR-2 with core balancing transforming model No. CBCT 35-1 or M/s. General Industrial controls relay catalogue Id: 17G715GF2 with core balancing transformer catalogue Id: 17H7NNN0. Make acceptable : SELEC, GIC OEM or authorized dealer only to quote with documentary evidence Firm's offered make: SELEC ( Warranty Period : Upto 12 months from the date of supply) For each MCCB in Panel. | — | — | — | 80,220 | |
| — | Breakup | for details. | — | ||
| Supply, Installation & pogramming charges includes panel cutout, meter fixing, programming of power analyser with bidirectional MFM with datalog, LCD display, accuracy class 0.5s, paramaeter- V, A, F, KVA, KVAr, kWh, kVAh, kVArh, PF(Trure and Displacement), Run hr, On hr, Interrupts, Phase angle, Total Harmonic Distortion, Neutral current, Max Demand (with RTC) K Factor, Export / Import & events with high-low time stamp. | — | — | — | 1,48,680 | |
| — | Breakup | for details. | — | ||
| Providing & erecting/replacement 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ tripalarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification. (Microprocessor based) | — | — | — | 5,16,000 | |
| — | Breakup | for details. | — | ||
| Providing & erecting/replacement 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification. (Microprocessor based) | — | — | — | 4,48,800 | |
| — | Breakup | for details. | — | ||
| Providing & erecting/replacement 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification.(Microprocessor based) | — | — | — | 4,35,200 | |
| — | Breakup | for details. | — | ||
| Providing & erecting/replacement 4 Pole MCCB, 415V, 125 A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification.(Microprocessor based) | — | — | — | 2,99,200 | |
| — | Breakup | for details. | — | ||
| Providing & erecting/replacement 4 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification. (Microprocessor based) | — | — | — | 2,22,400 | |
| — | Breakup | for details. | — | ||
| Providing & erecting/replacement 4 Pole MCCB, 415V, 63 A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification. (Microprocessor based) | — | — | — | 2,22,400 | |
| — | Breakup | for details. | — | ||
| Supply and Erection of 7.5 KVA 110 V DC, Sine Wave Inverter with PWM Technology, Micro Controller IGBT Technology and Digital Display. Input -90-140 V DC, Output- 230V AC, 50 Hz. Protections -Fuse at Output, DC Low,DC High, and Over Load. Transformer - As per IS 6297, 1973, Inverter as per IS 13314 of 1992. Note: Suitable for Indoor locations. Accepted offer: Model Number: Numax legendary DII series 7.5KVA/6KW 110VDC to 220VAC Converter. Accepted make/brand:Numax legendary DII series. (Warranty Period : Upto 30 months from the date of delivery.) | — | — | — | 6,68,728 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tenderdocument252026.pdf
ATTACHMENT
GCCApril2022dt.27.04.2022.pdf GCC Apr 2022
ATTACHMENT
ACS1to6ofGCC.pdf
ATTACHMENT
ACS7to10ofGCC.pdf
ATTACHMENT
ACS11toGCC.pdf
ATTACHMENT
GCCApril2022dt.27.04.2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .