| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | L1 | Accepted-AOC lowest price | |
| 2 | Rejected-Technical | - | Rejected-Technical technically not qualified | |
| 3 | Rejected-Technical | - | Rejected-Technical technically not qualified | |
| 4 | Rejected-Technical | - | Rejected-Technical technically not qualified |
Tender Value
₹37 L
EMD Value
₹37,000
Closing Date
22 Feb 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive officer
zaminuthukuli town panchayat
Construction of two class room buliding at ward no 5 GNSS PREMISES in zaminunthukuli townpanchayat
2024_DTP_427051_1
972/re1/2023
Open Tender
Civil Works
Works
90 days
zaminuthukuli town panchayat
as per norms
2 documents required · 2 mandatory
₹0
₹37,000
29 Mar 2024
18 Feb 2024
22 Feb 2024
18 Feb 2024
22 Feb 2024
18 Feb 2024
18 Feb 2024 - 22 Feb 2024
Amount
EARTHWORK EXCAVATION for foundation in all soils and sub soils and to full depth as may be directed except in rock requiring blasting, but inclusive of shoring, strutting and baling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of not more than 15cmtghick, well rammed and consolidated and depositing the surplus earth within the compound in places shown by the departmental officers with initial lead and lift etc., complete complying with standard specifications
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
CEMENT CONCRETE 1:4:8 (One cement, Four sand and Eight aggregate) using 40mm gauge hard broken granite stone jelly for FOUNDATION including dewatering if found necessary and laid in layers of not more than 15cmthick, complying with standard specification.
BRICKWORK in cement mortar 1:5 (One cement and five sand) using second class chamber burnt bricks of size 23 x 11cm x 7cm for the following including curing etc., complete complying with standard specifications. a) For Foundation and Basement
b) For Superstructure in Ground Floor
Filling in basement with ExCAVATED EARTH in layers of not more than 15cmthick, well rammed, watered and consolidated, complying with standard specification etc., complete.
Supplying and filling in foundation and basement with FILLING M.SAND in layers of not more than 15cm thick, well watered, rammed and consolidated complying with standard specification etc., complete.
Conveyance of Gravel for filling the sides and basement with a lead of 0 to 8km in layers of not more than 15cm thick, well rammed, watered and consolidated complying with standard specification etc complete.
Supplying and erecting SHUTTERING including necessary supports for plane surfaces in foundation and in all floors for COLUMN FOOTINGS, PLINTH BEAMS, STAIRCASE STEPS etc., using mild steel sheets of suitable size and BG 10 stiffened with welded mild steel angles for boarding supported by Casuarinas props of 10cm to 13cm diameter spaced at suitable intervals etc., complete complying with standard specification and as directed.
SUPPLYING AND ERECTING CENTERING FOR SIDES and soffits including supports and strutting unto 4.30m high for plane surfaces such as RCC SLABS, RECTANGULAR BEAMS, TEE OR ELL BEAMS, LINTELS, BED BLOCKS, STAIRCASE WAIST and landing slabs, landing beams, canopy etc., with all cross bracings using mild steel sheets of size 90cm x 60cm and BG 10 stiffened with welded mild steel angles of size 25mm x 25mm x 3cmfor boarding laid over country wood joists of size 10cm x 6.50cm spaced at about 90cm centre to centre and supported by Casuarinas props of 10cm to 13cm diameter spaced at 75cmcentre to centre etc., complete complying with standard specification and as directed.
Supplying and erecting CENTERING AND SHUTTERING with necessary supports for plane surfaces such as RECTANGULAR COLUMNS, BOxING, SLABS AT TOP AND BOTTOM, SILL SLABS, SUNSHADES etc., with all cross bracings using mild steel sheets of size 90cm x 60cm and BG 10 stiffened with welded mild steel angles of size 25mm x 25mm 3mm for boarding laid over country wood joists of size 10cm x 6.50cm spaced at about 90cm centre to centre and sides supported by Casuarinas props of 10cm to 13cm dial spaced at 75cm centre to centre etc., complete complying with standard specification and as directed.
Providing and laying in position, standardised concrete Mix M-2o Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). In foundation and basement
For Superstructure in Ground floor
Cement Concrete 1:3:6 (One Cement, Three sand and Six broken stone jelly) using 40mm size hard broken stone jelly for dummy columns, excluding cost of centering shuttering reinforcement grills and fabrication charges but including curing etc. complete. (Reinforced Cement Concrete 1:2:4 for slab to be extended upto top of splashing with pressed tiles and future extension rods to be embedded in CC 1:3:6 (One Cement, Three Sand and Six hard broken stone jelly). Dummy columns should be at least 1 metre height) For Superstructure in first Floor
Supplying ,fabricating and placing in position of steel reinforcement using mild steel/Ribbed tor steel rods for all RCC works as per the design given including cost of steel and binding wire in all floors complying with standard specification and drawings.
Supplying and fixing fine polished cuddapah slab of 20 / 30mm thickthickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.
CEMENT CONCRETE 1:3:6 (One cement, three sand and six aggregate) using 20mm gauge hard broken granite stone jelly for FLOORING including consolidating , curing etc., complete and rendering the top rough to take floor finish. The rate is to include necessary planking for panealling into bays wherever necessary and laid in layers of not more than 15cmthick, complying with standard specification.
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three C.S.sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three C.S.sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Plain Cement Concrete 1:2:4 (one cement, two C.S.sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
BRICK PARTITION WALL of the following thickness in cement mortar 1:3 bricks of size 23cm x 11cm x 7cm and complying with standard specification etc., complete in the following floorsNote: Wherever reinforcement is considered necessary by the departmental officers, hoop iron reinforcement shall be provided by the contractor as directed during execution without any extra cost. 11.50cm Thick For Superstructure in Ground Floor
PLASTERING with cement mortar 1:5 (One cement and five sand) 12mm thick in all floors complying with standard specifications
SPECIAL CEILING PLASTERING and finishing all the RCC exposed surfaces such as RCC slabs, sunshades, canopies, staircase steps, landing slabs etc., with cement mortar 1:3 (One cement and three sand) 10mm thick including hacking the surfaces and providing necessary cement mortar nosing beading as per standard size and specification wherever necessary using the same mix as directed by the departmental officers etc., complete complying with standard specification
Providing BLACK BOARD in two layers with first layer in cement morter 1:5 of 20 mm thick and the second layer in combination morter 1:1:6 20 mm thick and providing band all round the black board in cement morter 1:5 of 20 mm thick and 50 mm width including cost of one coat of Black oxide paint of approved quality complying with standard specification and as directed by the departmental officers.
Casting and fixing R.C.C. PRECAST SLAB of the 75mm thick slab thickness in cement concrete 1:2:4 (One cement, two sand and four broken jelly) using 20mm hand broken granite stone jelly and top plastered with cement mortar 1:3(one cement and three sand) 10mm thick ExCLUDING cost of reinforcement but including moulding, curing, finishing fixing in position etc., complete complying with standard specification and as directed by the departmental officers in all floors.
Fabrication and supplying and fixing M.S. STEEL DOOR with MS Equal angles of sizes 40x 20 x6 mm for outer frame using 40 x 6 mm M.S Flat for top 2/3 rd portion grilled and plain glazed and bottom 1/3rd portiion covered with 18 G CRC sheet with stiffermes etc., complete
Fabricating, Supplying and fixng in position of steel sheeted windows ( Three Leaves) with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion 'J' section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made of F7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly.2 numbers of sturdy hinges and one number of handle-cum-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of lenght 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers.All sections should be in confirmed with IS 7452/1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete
Fabricating, supplying and fixing of steel Emergency exitdoor cum, emergency window with the following specification. M.S. angle in size 40x40x6mm are used for the outer frames and M.S. angle of sie 35x35x5mm for the shutter frame, stiffners with 32x6mm M.S. flats provided at required intervals in the shutter frames 18 guage CR sheet is laid as panel and welded instant for 1/3 bottom portion of the shutter, M.S. flat 18x5mm is welded over the 32x6mm M.S flat sandwitching the CR sheet in between additional stiffner with 18x5mm M.S. flat is provided diagonally at the rear-side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 15kg/m2 and the top portion of operation emergency window is to be made of 25x25x3mm M.S. angle welded intact with CR sheet and 25x3mm M.S. flat at diagonally at the near side of the window at required interwals 6 Nos. of hinges to be provided,6 Nos of holdfast 100mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 2 Nos. one at top and the other at the bottom are to be provided one aldrop is provided at an appropriate place in the door 2 Nos. of 'D' type handle for emergency window and 2 Nos of handle for door is to be provided at appropriate places. A tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of materials, labour transportation to side of works, loading, unloading and all other incidental charges etc., complete.
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
PAINTING NEW IRON WORKS for doors, windows and ventilators, iron bars, weldmesh, wiremesh, screen, steel bars, flats and other similar works etc., with two coats of approved first quality of synthetic enamel paint over the existing red oxide primer in all floors. The rate is inclusive of cost of all materials and labour, brushes and scaffolding charges etc., complete complying with standard specification. (The paint to be used should be got approved by the Executive Engineer before use on work)
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Weathering Course with broken brick jelly 20mm size pure slacked lime over R.C.C. roof slab the preparation of 32:12.5 for required depth and slope etc. complete.
Finishing the top of roof with one course of machine pressed tiles 23 C.m x 23 C.m x 2 C.m size using cement mortor 1:3 mix mixed with 2% by weight of Crude Oil and pointing with Cement Mortor 1:3 mix Cost of all materials and labour charges and brick jelly concrete etc., complete as per standard specifications.
Supply and run of 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains (SD 64).
Supply and run of 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains (SD 64).
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) (SD-24).
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .