Loading…
Loading…
Tender Value
₹5.8 Cr
EMD Value
₹11.5 L
Closing Date
21 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER
17 conditions · 4 needing a document upload
Financial Eligibility Criteria: The Tenderer shall be eligible only if he fulfills the following Standard Financial Eligibility Criteria FOR WORKS COSTING ABOVE Rs.50.00 LAKHS: Client certificate from other than The tenderer must have minimum average annual contractual turnover of V OR V/N crores whichever is less where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India. No Technical and Financial credentials are required for tenders having value up to Rs.50 lakh. For tenders costing more than Rs.20 crore, eligibility criteria include bid capacity also as specified in clause 10.3 of IRSGCC- April2022 - PART I - "Regulations for Tenders and Contracts - For the Guidance of Engineers & Contractors for Works Contracts." The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI. The tenderer will be qualified only if it's available bid capacity is equal to or more than the total bid value of the present tender
BID CAPACITY: Bid Capacity shall be governed in terms of clause 10.3 of IRSGCC 2022. The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI of IRSGCC 2022. The Bid Capacity is applicable for works costing more than Rs.10 Crores and details regarding Bid Capacity shall be submitted along with the tender in Proforma-2 duly verified and certified by the Chartered Accountant.
A) Technical eligibility criteria for non-composite works costing above Rs.50.00 lakhs As per clause 10.1(a) of IRGCC-2022( part-1) :. (a)The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: 1.Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, Or 2.Two similar works each costing not less than the amount equal to 40% of advertised value of the tender or 3.One similar work each costing not less than the amount equal to 60% of advertised value of the tender B ) Technical eligibility for composite tender: 1.Each component of value more than 2 Crs shall be taken for evaluation of technical eligibility as per 10.1(b) of IRSGCC-2022. 2.In case single completion certificate containing more than one component is submitted by the tenderer, value of each component is to be specified in that completion certificate. Separate completed works of minimum required values for each component shall also be considered for fulfillment of technical eligibility criteria 3.In case tenderer fails to submit completion certificate with component wise value bifurcation of work for evaluation of technical eligibility, the certificate shall be treated Incomplete and invalid and shall not be considered for evaluation of technical eligibility. 4.Technical eligibility shall be fulfilled by tenderer or any member having minimum 26% share in case of JV as per clause 10. 1.(b) (i) of IRSGCC- 2022 (Part- I) and 17.15.1(b) of IRSGCC-2022 (Part- I) for the component/components of value of more than 50% of tender value or by Sub- contractor as per clause 7(a)(ii) of GCC (Part-II) for the other component/ components of value less than 50% of tender value. Each other member of JV shall have technical capacity of minimum 10% of advertised value of any component. 5.If the Tenderer proposes to sub- contract any component/components as per item 4 above , which is less than 50% of tender value, then a formal agreement duly notarized, legally enforceable in the court of law, shall be executed by the sub- contractor(s) and shall be submitted along with the offer for considering subletting of that scope of work towards fulfillment of technical eligibility as per clause 7(a)(ii) of Part II of IRSGCC 2022. 6.For component less than Rs 2 Cr, technical Eligibility will not be considered in tender evaluation and the documents of sub-contractor need not be submitted along with tender. 7.The contractor will engage an eligible sub- contractor after award of contract with the approval of Chief Engineer in writing subject to complying clause 7 of Part II of IRSGCC 2022 . Note: Tenderers may see Explanation for Para 10 of the Tender Form (Second Sheet) including Para 10.1 to 10.5 - Eligibility Criteria of IRSGCC-2022.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. The work executed by the tenderer for any Govt. /Govt.bodies/PSUs and public listed company shall only be considered for fulfilling of Technical Eligibility Criteria. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Please submit a certificate in the prescribed format (please download the format from the link given below) for verification / confirmation of the documents submitted for compliance of eligibility / qualifying criteria. 1.1.1 Non submission of the certificate, or submission of certificate either not properly filled in, or in a format other than the prescribed format shall lead to summary rejection of your offer. ( Click here to download the Format of Self Certification)
Defination of Similar Work :- Execution of indoor work(hardware/software) of same make of EI as existing one. Note: The tenderer should be either the existing EI's OEM or an OEM- authorised/supported agency. The tenderer shall submit an undertaking from either the OEM or the OEM-authorised/supported agency for installation, testing, and commissioning (including after-sales support during the warranty period).Authorisation required to be submitted existing OEM i.e OEM of Medha EI and OEM of Hitachi EI (AJP station)
111 conditions · 4 needing a document upload
Uploading of Scanned copy/copies of proof (s) of Technically Eligibility Criteria as mentioned in Standard Technical Criteria (asperProforma-1).
Uploading of Scanned copy/copies of proof(s) of Financial Eligibility Criteria as mentioned in Standard Financial Criteria (as per Proforma - 2 A & relevant documents)
Uploading of Scanned copy of Bid Capacity (as per Proforma - 2), and in terms of clause No. 10.3 and 10.5 of IRGCC-2022 (if applicable)
Uploading of Scanned copy of Certificate as per the format for Certificate linked under heading Submission of Certificate.
Uploading of required documents in case of Individual/Proprietary Firm/Concern (or) Partnership Firm (or) Company (or) LLP Firm (or) Registered Society & Registered Trust (or)Joint Venture Firm (or) HUF etc., as mentioned in Commercial Compliance (whichever is applicable).
Uploading of Scanned copy of List of Machinery, Tools & Plants (as per Proforma - 3)
Uploading of Scanned copy of Statement of Bank details, PAN & GST (as per Proforma - 5)
Uploading of Scanned copy of the declaration regarding employment of Retired Engineer / Retired Railway Officer (as per Proforma - 6)
Uploading a scanned copy of the Memorandum of Understanding in the case of a JV firm (as per Proforma - 7)
Uploading of request for grant of Mobilisation Advance (as per Proforma-8), if applicable.
Uploading of Proforma for Self-Certificate in regard to meeting the Minimum Local Content requirements as per Make in India Policy for Procurement Order Value less than of Rs.10 Crores. (as per Clause - 45(a) of Special Conditions of Contract)(as per Proforma-9)
Uploading of Proforma of Certificate on percentage of Local Content as per Make in India Policy for Procurement Order Value more than Rs.10 Crores. (as per clause - 45(b) of Special Conditions of Contract)(as per Proforma-10)
Uploading of Method Statement, if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Any other document required for evaluation of his/their bid as deemed fit by the tenderer.
Scanned copy of Statement of Bank details, PAN&GST(as per Proforma- 5).
Scanned copy of Statement of Bank details
Scanned copy of PAN Card
Scanned copy of GST Registration Certificate
Request for Mobilisation Advance if applicable (as per Proforma- 8).
Proforma 9 for self-Certificate in regard to meeting the Minimum Local Content requirements as per Make in India Policy for Procurement Order Value less than of Rs.10 Crores.
Proforma-10 of Certificate on percentage of Local Content as per Make in India Policy for Procurement Order Value more than Rs.10 Crores.
Uploading of Scanned copy/copies of formal agreement duly executed and notarised by the main tenderer/contractor with the subcontractor for the component(s) of work in a composite work proposed to be executed through subcontractor(s).
In case of Proprietary Firm / Proprietary Concern, the tenderers shall scan and submit with his offer (i)An undertaking that he is not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of opening of bids, either in individual capacity or as a member of the partnership firm or JV in which he was / is a partner/member. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract. (ii)All other documents in terms of explanatory notes in clause 10 of IRSGCC - April -2022-Part-I. (iii)All other documents as per Clause 14 of IRSGCC -April -2022- Part-1.
In case of Partnership Firm, the tenderer(s) shall scan and submit with their offer, the following documents: (i)A notarized copy of partnership deedor a copy of partnership deed registered with registar. (ii)A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract (iv)Other documents as mentioned in terms of cpara 10 tender form (2nd sheet) of IRSGCC April-2022-Part I. (v) All other documents as per Clause 14 and Clause 18 of IRSGCC -April -2022- Part 1.
In case, the Tenderer is a Company, the tenderer(s) shall scan and submit with their offer, the following documents: (i)The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii)A copy of Certificate of Incorporation (iii)A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv)An undertaking that the Company is not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of opening of bids, either in individual capacity or as a member of the partnership firm or JV in which the Company was / is a partner/member. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract. (v)All other documents in terms of 10 of tender form (2nd Sheet) of IRSGCC - 2022 (vi) All other documents as per Clause 14of IRSGCC -April -2022- Part 1.
In case, the Tenderer is a JV Firm, the tenderer(s) shall scan and submit with their offer the following documents: In case one or more of the members of the JV is/are (A)Partnership firm(s), following documents shall be submitted: (i)A notarized copy of the Partnership DeedorCopy of partnership deed registered with registar, (ii)A copy of consent of all the partners or individual authorized by partnership firm, to enter into the Joint Venture Agreement on a stamp paper, (iii)A notarized or registered copy of Power of Attorney in favour of the individual to sign the MOU/JV Agreement on behalf of the partnership firm and create liability against the firm.(iv)An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. In case one or more members is/are (B) HUF, the following documents shall be enclosed: (i) A copy of notarized affidavit on Stamp Paper declaring that his concern is a proprietary concern and he is sole proprietor of the concern or he who is signing the affidavit on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. In case one or more members of the JV is/are (C)Companies, the following documents shall be submitted: (i)A copy of resolutions of the Directors of the Company, permitting the company to enter into a JV agreement, (ii)The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (iii)A copy of Certificate of Incorporation (iv)A copy of Authorization/copy of Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender, sign MOU/JV Agreement on behalf of the company and create liability against the company. In case one or more members of the JV is/are LLP firm/s, the following documents shall be submitted: (i)A copy of LLP Agreement (ii)A copy of Certificate of Incorporation of LLP(iii) A copy of resolution passed by partners of LLP firm, permitting the Firm to enter into a JV agreement.(iv) A copy of Authorization /copy of Power of Attorney issued by the LLP firm (backed by resolution passed by the Partners) in favour of the individual, to sign the tender and/or sign the MOU/ JV agreement on behalf of the LLP and create liability against the LLP. (v)An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders/ contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the contract liable for determination underClause 62 of the Standard General Conditions of Contract.
In case, the Tenderer is a JV Firm (Continued from above), (E)In case one or more members of the JV is/are Society/s or Trust/s, the following documents shall be submitted: (i)A copy of Certificate of Registration (ii)A copy of Memorandum of Association of Society/Trust Deed A copy of Rules & Regulations of the Society (iii) A copy of Power of Attorney, in favour of the individual to sign the tender documents and create liability against the Society/Trust.(F)Other documents as mentioned in terms of para 10of Tender form(2nd sheet) of IRSGCC-April-2022 Part-I. (G)All other documents as per Clause 14 , 17 & 18 of IRSGCC-April2022 -Part 1 are to be submitted.
In case the Tenderer is HUF, the following documents shall be submitted along with the tender: (i)A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii)An undertaking that the HUF is not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of opening of bids, either in individual capacity or as a member of the partnership firm or JV in which HUF was / is a partner/member. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract. (iii)All other documents in terms of Para 10 of Tender form (2nd sheet) of IRS GCC April 2022. (iv) All other documents as per Clause 14 of IRSGCC -April-2022- Part 1.
In case tenderer is a LLP Firm registered under LLP Act-2008, the following documents shall be submitted: (i)A copy of LLP Agreement (ii)A copy of Certificate of Incorporation (iii)A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract (v)All other documents in terms of Para 10 of Tender form(2nd sheet) of IRSGCC- April-2022 Part-I. (vi) All other documents as per Clause 14 of IRSGCC -April -2022- Part 1.
In case the Tenderer is a Registered Society & Registered Trust, the following documents shall be submitted: (i)A copy of the Certificate of Registration (ii)A copy of Memorandum of Association of Society / Trust Deed. (iii)A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) Copy of rules and regulations of the society. (v) All other documents in terms Para 10 of Tender form(2nd sheet) of IRSGCC- April-2022 Part-I. (v) All other documents as per Clause 14 of IRSGCC -April -2022- Part 1.
The tenderer whether sole proprietor/Company or a partnership firm/JV venture (JV) / Registered Society / Registered Trust/HUF etc., if they want to act through agent or individual(s), should submit along with tender, a copy of Power of attorney duly stamped and authenticated by a notary public or by magistrate in favour of specific persion whether he/they be partner(s) of the firm or any other person agreement, receive money, co-ordinate measurement through contractors authorized engineer, witnessed measurement, sign measurements books, compromise, settle, relinquish any claim(s) preferred by the firm and sign " No Claim Certificate" and refer all or any disputes to arbitiration the above power of attorney shall be submitted even if such specific person is authorized for above purpose through partnership deed/memorandum of understanding/Article of Association or such other document, failing which, tender is liable to be rejected.
An undertaking that bidder is not blacklisted or debarred by railways or any other Ministry /Department of Government of India from participation in tender on the date of opening of bids, either in individual capacity or as a member of the partnership firm or JV in which he was/ is a partner/member. Concealment /wrong information in regard to above shall make the contract liable for determination under clause 62 of the General conditions of the contract.
Closure of Interlocked LC gates (Traffic/Engineering) at LC No.46 between TK-MLSA Stations, LC No.58 at bet GBB-NTR stations No.59 Nittur station yard,LC No.56 between Gubbi-Nittur Stations LC No.86 between TTR-HVL stations, LC No.88 between TK-ASK section, LC No.138 between NVF-AJP stations, LC No.35 between KIAT-NDV stations, LC No.38 between KIAT-TK stations, LC No.39 between KIAT-TK stations and LC No.71 between MLU-CPL stations, in lieu of ROB/RUB work over SBC & MYS division.
B-SG-CN-BNC-SNT-LCClosure~SWR
B-SG-CN-BNC-SNT-LCClosure
Open
Works - General
12 Months
Dharwad, Karnataka
₹0
₹11.5 L
22 Aug 2026
22 Aug 2026
7 Sept 2026
141 items across 1 schedule · ₹3,55,68,197 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of Signal aspect - LED Signal Lighting Unit Red with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest. | Numbers 10.00 | — | 9,409 | 94,090 |
| 2 | Supply of Signal aspect - LED Signal Lighting Unit Yellow with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest. | Numbers 10.00 | — | 9,846 | 98,460 |
| 3 | Supply of Signal aspect - LED Signal Lighting Unit Green with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest. | Numbers 5.00 | — | 10,737 | 53,685 |
| 4 | Supply of Colour light Signal Pole 140mm dia, 4.6m tall as per latest specification IRS:S 6-81 Rev.3 or latest. | Numbers 2.00 | — | 7,388 | 14,776 |
| 5 | Supply of CLS ladder with Platform and Shoes to suit CLS pole 4.6m, as per latest specification. | Set 2.00 | — | 6,974 | 13,948 |
| 6 | Supply of CLS ladder with Platform and Shoes to suit CLS pole 3.6m, as per latest specification. | Set 8.00 | — | 6,726 | 53,808 |
| 7 | Supply of Surface Base to suit CLS Signal Pole 140mm dia as per latest specification. | Numbers 8.00 | — | 8,966 | 71,728 |
| 8 | Supply of FRP 2 aspect color light unit assembly as per RDSO Spec. No. RDSO/SPN/194/2006 Rev .2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 08 Nos) | Numbers 7.00 | — | 34,696 | 2,42,872 |
| 9 | Supply of FRP 3 aspect color light unit assembly as per RDSO Spec. No. RDSO/SPN/ 194/2006 Rev.2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 12 Nos) | Numbers 1.00 | — | 37,009 | 37,009 |
| 10 | Excavation of pit, casting concrete foundation as per Drg.No.SG/SWR/052 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation bolts, cement, river sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 10.00 | — | 11,255 | 1,12,550 |
| 11 | Erection of surface base, signal pole, mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of speed limit board wherever necessary,termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. ['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Collar-rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor]. | Numbers 12.00 | — | 12,131 | 1,45,572 |
| 12 | Supply and fixing of Retro-reflective type Goods Warning Board as per practice & SEM (Angle/Rail is to be supplied by Railway). | Numbers 4.00 | — | 9,560 | 38,240 |
| 13 | Supply and fixing of retro-reflective type Calling- On/STOP/BSLB/Legend boards as per practice & SEM (Angle/Rail is to be supplied by Railway). | Numbers 4.00 | — | 7,856 | 31,424 |
| 14 | Dismantling and releasing of Existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling. | Numbers 10.00 | — | 3,630 | 36,300 |
| 15 | Breaking of Concrete and releasing of STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly at a place as instructed by Railway representative at site. Also, the resultant pits shall be resurfaced and consolidating by ramming and levelling. | Numbers 4.00 | — | 1,860 | 7,440 |
| 16 | Casting concrete foundation and erection and painting of boards with LEGEND such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm, and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this item. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, river sand, cement, M.S.Flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 10.00 | — | 3,570 | 35,700 |
| 17 | Supply of apparatus cases Full size as per latest specification/drawing. | Numbers 6.00 | — | 24,248 | 1,45,488 |
| 18 | Supply of apparatus cases Half size as per latest specification/ drawing. | Numbers 40.00 | — | 17,320 | 6,92,800 |
| 19 | Supply of PBT terminals 25mm centre, as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest | Numbers 800.00 | — | 92 | 73,600 |
| 20 | Supply ARA Terminal block 6 Way, 25 mm Centre, made up of PBT as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest. | Numbers 150.00 | — | 381 | 57,150 |
| 21 | Supply of PBT terminals 60mm centre as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest. | Numbers 150.00 | — | 112 | 16,800 |
| 22 | Supply of 60mm center PBT Fuse blocks as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest. | Numbers 50.00 | — | 153 | 7,650 |
| 23 | Supply of 'E' type locks of different wards as per requirement with key per E type lock to Drg. No. SA.3376IM/Latest and RDSO Specn. No. IRS. S.30/64. Rev.0. | Numbers 75.00 | — | 903 | 67,725 |
| 24 | Supply of hylam sheet, resin bonded, 6mm thick, grade P3, to IS specification IS: 2036 of 1974 or latest and size 2400mm X 1200mm of colour approved by the site incharge. | Numbers 18.00 | — | 8,265 | 1,48,770 |
| 25 | Excavation of pit, casting concrete foundation and erection of Apparatus Case Full size as per Drg. No. SG/SWR/055 and fixing of 2 nos of "E" type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red oxide and two coats of aluminium paints, along with painting of termination and equipment particulars on the doors of apparatus cases as per instructions of railway representative at site. (Supply of apparatus case is not included in this item). [ Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the contractor]. | Numbers 6.00 | — | 21,778 | 1,30,668 |
| 26 | Excavation of pit, casting concrete foundation and erection of Apparatus Case Half size as per Drg, No.SG/SWR/056, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this item). [Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor] | Numbers 40.00 | — | 15,363 | 6,14,520 |
| 27 | Excavation of pit in and around the existing Full location boxes very carefully without damaging the working cables and Shifting and turning the Full location boxes (Apparatus Cases) to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. [All materials required for the work shall be supplied by the Contractor]. | Numbers 6.00 | — | 5,786 | 34,716 |
| 28 | Excavation of pit in and around the existing Half location boxes very carefully without damaging the working cables and Shifting and turning the Half location boxes (Apparatus Cases) to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. [All materials required for the work shall be supplied by the Contractor]. | Numbers 40.00 | — | 3,830 | 1,53,200 |
| 29 | Termination of main, tail, signalling and power cables on25/60mm PBT terminals on phenolic sheet and internal wiring on terminal in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). { cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 -1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, river sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) | Numbers 1500.00 | — | 205 | 3,07,500 |
| 30 | Termination of main, tail, signalling and power cables on PBT fuse block on phenolic sheet and internal wiring on fuse blocks in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). ( cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 -1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) | Numbers 50.00 | — | 250 | 12,500 |
| 31 | Termination of main, tail, Signaling and power cables of Cables on 25/60mm PBT terminals and internal wiring by fixing additional terminals on the Existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this item). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. | Numbers 500.00 | — | 173 | 86,500 |
| 32 | Termination of new main/tail cables on the existing terminals/ fuse blocks in apparatus cases/ battery boxes/ CT boxes/ cable termination racks as per approved circuit diagram. The terminal particulars to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry of new cables in the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks with cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, sand and all other required miscellaneous materials shall be supplied by the contractor]. | Numbers 200.00 | — | 87 | 17,400 |
| 33 | Manufacture and Supply of M.S. Relay Frames of suitable size to Hold up to 4 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. | Set 2.00 | — | 5,849 | 11,698 |
| 34 | Painting of existing apparatus case - Full size without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 4.00 | — | 2,529 | 10,116 |
| 35 | Painting of existing apparatus case - Half size without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 6.00 | — | 2,419 | 14,514 |
| 36 | Strengthening of foundations of Signals, Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank. | Numbers 10.00 | — | 5,708 | 57,080 |
| 37 | Alterations to painted termination/ wiring particulars of functions in the Existing apparatus cases-Full Size, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re- numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 10.00 | — | 1,746 | 17,460 |
| 38 | Alterations to painted termination/ wiring particulars of functions in the Existing apparatus cases- Half Size, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re- numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 50.00 | — | 916 | 45,800 |
| 39 | Releasing of existing apparatus cases (Full/ Half/ Quartersize) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipment's, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site. | Numbers 10.00 | — | 3,434 | 34,340 |
| 40 | Filling earth around location boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming. The earth shall be taken from Railway premises as instructed by Railway representative at site. | Numbers 10.00 | — | 196 | 1,960 |
| 41 | Supply of Universal locks with one key for every ten locks. | Numbers 2.00 | — | 187 | 374 |
| 42 | Alteration to existing track circuits at Feed end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re- wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers 5.00 | — | 4,702 | 23,510 |
| 43 | Alteration to existing track circuits at Relay end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re- wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers 5.00 | — | 4,341 | 21,705 |
| 44 | Releasing of existing TLJB boxes with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers 20.00 | — | 157 | 3,140 |
| 45 | Installation, wiring, testing and commissioning of electrical/mechanical lifting barrier as per requirement. | Set 7.00 | — | 35,218 | 2,46,526 |
| 46 | Supply of Electric Key Transmitter - Rotary type of required ward Nos. with keys, as per specification/ No. IRS S.21/2001 Rev.1.0 or latest. | Numbers 8.00 | — | 9,315 | 74,520 |
| 47 | Supply and Fixing of Normal/Crank Handle Box/Emergency Key Box at Interlocked LC Gates, made of Teak wood with Glass fronted door as per specification. Polishing on all exposed surface and for with EKT inside the box. Micro push switch of suitable make with 2NO+2NC contacts and veeder counter non-reset type and wire them as per the approved circuit diagram. The box should have hinges and pad locking arrangements with one Lock with duplicate keys and key chain with label. (All materials except EKT are to be supplied by the contractors.) | Numbers 10.00 | — | 7,694 | 76,940 |
| 48 | Fixing of EKT instrument with (or) without crank handle or on suitable fixtures at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire PVC 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting. (Supply of electric key transmitter and crank handles is not covered in this item). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility by using 25mm thick teakwood, bolts and nuts, paints, push switches, padlocks and other miscellaneous materials required for this work shall be supplied by the contractor]. | Numbers 8.00 | — | 5,522 | 44,176 |
| 49 | Fixing and wiring of Two Nos. of Electronic Gate Warning equipment for each level crossing gate, one on each road warning signal, amplifier in the apparatus case with wire PVC 3/0.75mm and 16/0.2mm copper, and painting. (Electronic Gate Warning Equipment and amplifier will be supplied by Railways). [All wiring, fixing and painting materials shall be supplied by Contractor]. | Set 7.00 | — | 4,877 | 34,139 |
| 50 | Design, fabrication and supply of Gate Indication Panel of 16 SWG, powder coated MS sheet of size 450mm x 300mm x 100mm approximately consisting of different colour LEDs with holders suitable to work on 24VDC supply. Indications on the front panel shall be as per typical diagram supplied by Railways. All descriptions on the front panel have to be neatly painted. The Panel shall then be wired using wire PVC 16/0.2mm copper as per the approved circuit diagram and installed in the gate lodge as instructed by Railway representative at site. [All materials required for the work shall be supplied by the Contractor]. | Numbers 4.00 | — | 15,879 | 63,516 |
| 51 | Installation of LC control panel cum illuminated diagram board at Level Crossing gate lodge and wiring the same including interconnections and painting. (Supply of LC control panel cum illuminated diagram board is not included in this item). [Wire PVC 16/0.2mm copper, soldering materials, LEDs, resistances and all other required miscellaneous materials shall be supplied by the Contractor.] | Numbers 4.00 | — | 6,703 | 26,812 |
| 52 | Supply of Sliding Boom Type Gate as per E.Rly/Signal Workshop /HWH's Drg. No. BSA/29/730, BSA/29/731, BSA/29/737. This includes supply of 5 nos 'E' type Lock with Key as per IRS Spec. No. IRS:S- 30/64 with Latest Amdt and as per Drg. No. SA-3376/M with latest admt. Ward No. to be decided by the site engineer. 'E' type lock to be fixed on MS Plate as per Site requirement (Gate = LC Gate) | Per Gate 6.00 | — | 1,09,517 | 6,57,102 |
| 53 | Fixing in position and commissioning of Sliding Barrier Boom Set (one set will consist of two sliding barrier booms, one for either side of track) this include carry out civil masonary work at site like digging of pits for foundations, casting of RCC foundation and fixing of foundation bolts (12 nos. in each site of size 18"x18"x36"). This also include loading, unloading and leading of all the material to site of work from the store of Concerned SSE/Sig/ Incharge (One set at each location) This include complete sliding gate in working order as per instruction of Railway Engineer at site and painting of sliding boom type barrier of LC gate with metallic paint, similar to Asian paint or better .All materials except sliding boom gate & 'E' type lock with key to be supplied by the contractor. (Gate = LC Gate) | Per Gate 6.00 | — | 43,111 | 2,58,666 |
| 54 | Supply and Installation of Wire Insulator for wire operating level crossing, lifting barriers/ signals as per latest specification No. IRS S47-74 | Numbers 8.00 | — | 3,492 | 27,936 |
| 55 | Supply and Installation of Insulator of Point Rodding at function end and lever end as per instruction of site engineer. | Numbers 6.00 | — | 2,607 | 15,642 |
| 56 | Excavation of pit, concreting 'A' type foundation and fixing ground lever frames single/double as per Drawing, complete with ground connection. The work includes concreting of 'A' type foundations and fixing of HP lock and connecting the ground lever frame with the HP lock using MS rod as instructed by Railway representative at site. (Supply of ground lever frames, hand plunger locks and A- type base are not covered in this item). [Cement, sand, stone jelly of size20/25mm, fixing bolts and nuts with washers and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers 10.00 | — | 8,331 | 83,310 |
| 57 | Testing and commissioning the Entire signalling installations jointly with the Railway representative at the LC gates covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this item). (Gate = LC Gate) | Per Gate 10.00 | — | 15,534 | 1,55,340 |
| 58 | Releasing of all the S & T gadgets at LC gates like SM slide instruments, illuminated diagram board, block counter, termination box, telephones, emergency key box, dismantling of ground lever frame along with all connected lever locks, 'E' type locks, HP locks, breaking and removal of concrete foundation, lock rods with rod roller trestles, complete assembly, cranks, compensators, 'A' type concrete foundation on the rod run, transmission wires single wire/double wire accounting and stocking them neatly at a place as instructed by Railway representative at site. After releasing any holes on the walls/ floor are to be filled with cement mortar and plastered. | Set 9.00 | — | 10,665 | 95,985 |
| 59 | Excavation of cable trench as per cable route plan, up to depth of 1.2 Mtr.and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C- 40(NKG), SK/4/95/NKG,SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on South Western Railway and instructions of Railway Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. Of cables head way is not available, 4" of 1:2:4 concreting should be done. Note:-(b-1) payment will be made as per actual work done on pro-rata basis, if required depth is not available at site.(b-2) if the depth of trench is not uniform in a span of 100 mtr. or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment. | cum 2000.00 | — | 300 | 6,00,000 |
| 60 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this item). | Metre 9000.00 | — | 94 | 8,46,000 |
| 61 | Supply and Placing of Polyolefin Cable channel of size, Width 240/340 mm, Height 155/230 internal/external, length 1 m produced of polyolefin with Fire protection class k-1 in accordance with DIN-53438 Part II for laying Signalling/Telecom cables, channel attachable to each other with male- female swallow tail connectors and having suitable detachable cover | Metre 2000.00 | — | 2,521 | 50,42,000 |
| 62 | Supply and Laying of PVC Warning Tape colour Orange, width of 250mm (10") by printing with black letters 'Indian Railway Signal/Telecom/OF Cable' on both sides | Kilometre 13.00 | — | 45,908 | 5,96,804 |
| 63 | Refilling of cable trench 1m depth by 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling | Metre 9000.00 | — | 23 | 2,07,000 |
| 64 | Supply of High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters as per latest specification No. IS 4984: 2016 with latest amendments and Material Grade: PE 80. | Metre 500.00 | — | 763 | 3,81,500 |
| 65 | Laying of HDPE Pipe 110 mm outer Dia, 10mm thickness along with collars in trenches at places of platform cutting etc and wherever required as per the instruction of site engineer. | Metre 500.00 | — | 69 | 34,500 |
| 66 | Digging of cable trench to a depth of not less than 30CMs in rocky terrain, concreting the trench with 150mm thick concrete with 1 cement, 2 sand, 4 grade stone 20mm nominal size. (All the materials are to be supplied by the contractor). | Metre 1000.00 | — | 230 | 2,30,000 |
| 67 | Concreting of cable laid in the trench or GI pipe/DWC/HDPE pipe in which cable is already laid to a size of 300x300mm with 1:3:6 mortar. (All the materials required for the work should be supplied by the contractor). | RMT 1000.00 | — | 624 | 6,24,000 |
| 68 | Laying of Signaling/Power/Telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this item). | Metre 20000.00 | — | 21 | 4,20,000 |
| 69 | Supply and Fixing of PVC casing and capping/PVC pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/ Reservation office / Data logger/FOIS room etc. (All required material for fixing to be arranged by the contractor) | Metre 100.00 | — | 66 | 6,600 |
| 70 | Supply of GI pipes - 100mm dia-4.5mm thick as per latest specification. | Metre 300.00 | — | 1,652 | 4,95,600 |
| 71 | Provision of GI pipes (50/100/150mm dia) for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, the work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre 300.00 | — | 384 | 1,15,200 |
| 72 | Provision of GI pipes (50/100/150mm dia) for cable laying in Hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre 300.00 | — | 335 | 1,00,500 |
| 73 | Supply of Permanently Lubricated High Density Polyethylene Duct (PLB-HDPE), 40/33 mm Dia, along with End Cap, End Plug, Cable Sealing Plug and Couplers, as per RDSO/SPN/TC/45/2013 Rev.2 with Amd 3.0 or latest | Kilometre 9.00 | — | 97,538 | 8,77,842 |
| 74 | Laying of PLB HDPE Duct, 40/33 mm Dia, in the trenches and in the protective works already provided including in HDD portion and supply pulling of Nylone rope through it at different places as per direction of engineer incharge or site engineer | Kilometre 9.00 | — | 14,607 | 1,31,463 |
| 75 | Duct Integrity test for PLB HDPE Duct, 40/33 mm Dia, as per latest specification. | Kilometre 9.00 | — | 2,306 | 20,754 |
| 76 | Blowing of OFC Cable in already laid PLB HDPE Duct, 40/33mm Dia, by using Blowing machine, providing the sufficient loops in loop/joint chambers and other associated works. | Kilometre 9.00 | — | 17,232 | 1,55,088 |
| 77 | Horizontal direction drilling/boring without damage of surface road/track using Auger Machine (HDD machine). The bore shall be upto 200 mm dia& shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different dia DWC-HDPE pipe/GI pipes coupling etc. as per direction of Engineer Incharge. Note:- Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. | Metre 1000.00 | — | 1,531 | 15,31,000 |
| 78 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, laying of DWC/HDPE/RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item). | Metre 1000.00 | — | 459 | 4,59,000 |
| 79 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/HDPE/RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item). | Metre 300.00 | — | 597 | 1,79,100 |
| 80 | Supply of RCC Cable Markers as per DRG.No.SG/SWR/067 or latest guidelines. The lettering on the Cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site. | Numbers 750.00 | — | 366 | 2,74,500 |
| 81 | Digging of pit to a depth of 800mm of size 300mmX300mm, casting of Concrete foundation of size 300mmX500mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing. | Numbers 750.00 | — | 267 | 2,00,250 |
| 82 | Excavation of cable coil pit to a size of 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum 150.00 | — | 1,131 | 1,69,650 |
| 83 | Excavation of Cross trench to a depth of 1M or as per site requirement, for identifying the existing cable path without damaging the working cables. | RMT 750.00 | — | 205 | 1,53,750 |
| 84 | Releasing/shifting of Existing/Already laid Signalling/Telecom cables to facilitate engineering construction works. | Metre 500.00 | — | 16 | 8,000 |
| 85 | Cable armours soldering and earthing as instructed by incharge SSE/JE at site. (Per Unit=Per cable) | Per Unit 100.00 | — | 34 | 3,400 |
| 86 | Cable Route Tracing service using Radio detection make Advanced Cable & Pipe Locator equipment with GPS co-ordinates logging facility) - Equipment model or better to be used for the Cable route tracing service RD8100 PDLG or RD8200G - Report in the form of CSV/KML file (soft copy) to be submitted to Customer within 15 days from the date of work completion at site. | Day 5.00 | — | 29,530 | 1,47,650 |
| 87 | Supply of Double walled corrugated pipe - 103.5mm inner dia& 120mm outer dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as specified in the Tender document. | Metre 500.00 | — | 514 | 2,57,000 |
| 88 | Final location joint survey of proposed cable route plan (Quad / OFC cable) and submission for approval of Railway. The details instruction / guide lines regarding joint survey and preparation of cable route plan are given in Tender document. Contractor will submit two copies of prints with soft copy to checking by Railways. If alterations are suggested by Railways, then again two copies of prints will be provided for advance approval after carrying out all the alterations as suggested / proposed by Railways. Tracing will be provided to approval by Railway. All drawings will be prepared in AUTOCAD. It also includes preparation and submission of final cable route plan on 75-micron standard polyester film which includes details of entire section in which quad / OFC cables are laid. Once Railway has approved and signed tracings for cable route plan then contractor will submit 6 (six) sets of photocopies for cable route plan in proper binding form. | Kilometre 9.00 | — | 1,047 | 9,423 |
| 89 | Carrying out Alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. The work includes painting alterations and releasing the unwanted wires carefully without disturbing the existing wiring. [Wire PVC 16/0.2mm copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay 100.00 | — | 720 | 72,000 |
| 90 | Arranging of sufficient staff by contractor and giving test to the railway in charge in testing of wires drawn point to point using buzzer. (Before and after soldering) | Sheet 50.00 | — | 553 | 27,650 |
| 91 | Incremental rate for vital signalling functions in El SYSTEM over and above 125 functions under item No 09_001 along with spares for the cards/modules/PCB, connectors/couplers, fuses, all relays, crimp contact, convertors etc. to the extent of 10% of item no. 090100& 090200. | Per 82.00 function | — | 91,297 | 74,86,354 |
| 92 | Supply of NON-AC Immunized Relays, Plug-In-Type, style QN1, 8F/8B Contacts, DC Neutral line Relay, working voltage 24V DC, metal to carbon, with plug board, retaining clip and connectors as per RDSO Specification No BRS:930, IRS: S: 34 & IRS: S: 23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABCDF | Numbers 21.00 | — | 3,818 | 80,178 |
| 93 | Supply of AC Immunized Relays, Plug-In- Type style QNA1, 8F/8B Contact, DC Neutral line Relay, working voltage 24V DC, metal to carbon with plug board, retaining clip and connectors as per RDSO Specification No BRS:931A, IRS: S@58<44@ IRS:S:34 & IRS:S:23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABDGH | Numbers 21.00 | — | 5,209 | 1,09,389 |
| 94 | Supply of Track Relays, Plug-in type, Style QTA2 - 9 Ohm, 2F-1B Contacts, metal to carbon with plug boards, connectors and retaining clips as per RDSO specification No. BRS:939A & 966(Appx F2) & IRS:S 23-88 Amdt.1, S34 & 60, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be FGHKX. | Numbers 5.00 | — | 5,360 | 26,800 |
| 95 | Releasing of Secondary cells and battery stands available in the battery room along with connecting strips, wires and terminal boxes carefully without causing any damage to the batteries, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing any holes in the walls/ flooring shall be filled with cement mortar and plastered. | Set 1.00 | — | 5,916 | 5,916 |
| 96 | Releasing of all Power equipment's including equipment stands, terminal boards, power panel etc., in the power room carefully without causing any damage to the equipment's after disconnecting all the supply wires. The released equipment's shall be accounted and stacked at a place as instructed by Railway representative at site. After releasing any holes in the walls/ flooring shall be filled with cement mortar and plastered. | Set 4.00 | — | 13,037 | 52,148 |
| 97 | Supply of Non-deteriorating type Fuse links 6 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006. | Numbers 25.00 | — | 46 | 1,150 |
| 98 | Supply of Non-deteriorating type fuse links 2 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006. | Numbers 25.00 | — | 36 | 900 |
| 99 | Alterations to Operating Panel and Indication Panels wiring, termination of all new alteration wires in the existing Operating and Indication Panels duly carrying out all the required alterations. | Numbers 3.00 | — | 30,428 | 91,284 |
| 100 | Provision of Earth Electrodes as per RDSO Drawing No.SG/SWR/057 and Earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, ASM room for block and control, and earthing of all equipment's in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS of flat 35mm X 6mm or 19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 65.00 | — | 3,967 | 2,57,855 |
| 101 | Supply of Basic material to construct Unit maintenance free earth as per RDSO spec. No. RDSO/SPN/197 Ver.1.0 or latest. consisting of a) copper bonded steel electrode of 3.0m long, 17.0 mm dia with copper bonding thickness mini 250 micron and UL listed and marked--1 no. b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kgs-03 No. c) Copper strip of 150X25x6mm to terminate earth rod-1 No. d) Copper strip of 300X25x6mm (MEEB)-1 No. e) Copper strip of 150X25x6mm (SEEB)-1 nos | Numbers 21.00 | — | 28,342 | 5,95,182 |
| 102 | Installation of Unit Maintenance Free Earth Pit as per RDSO specification No.RDSO/SPN/197 Ver.1.0 or latest and as per Technical Specification | Numbers 21.00 | — | 15,453 | 3,24,513 |
| 103 | Supply of 35 Sq mm Multi-strand Single Core PVC insulated Copper Cable as per IS: 694 for connecting Main Earth Electrode to MEEB in equipment room. Color: Green. | Metre 300.00 | — | 567 | 1,70,100 |
| 104 | Supply of 10 Sq mm Multi-strand Single Core PVC insulated Copper Cable as per IS: 694 for connecting SEEB to all equipment's. Color: Green. | Metre 50.00 | — | 159 | 7,950 |
| 105 | Installation of 35 sqmm single core Cu cable for connecting main earth electrode to equipment room (routing through GI pipe/DWC/HDPE/PVC conduit pipe of suitable size as per site requirement | Metre 300.00 | — | 203 | 60,900 |
| 106 | laying of 16 sqmm Cu cable/10 sqmm Cu cable between BRC and racks. The work includes mechanical connection by providing two Cu lugs and two steel screws, drilling to two holes and removal of powder coating on rack body, thimbles ties, etc. and routing the same as per site requirements. | Metre 50.00 | — | 431 | 21,550 |
| 107 | Supply of 50x6 mm GI Tape for interconnecting earth electrodes. | Metre 100.00 | — | 590 | 59,000 |
| 108 | Laying of 50x6 mm GI Tape for interconnecting earth electrodes. | Metre 100.00 | — | 205 | 20,500 |
| 109 | Carrying out exothermic welding for various conductors as per requirement. | Numbers 61.00 | — | 1,213 | 73,993 |
| 110 | Exothermic welding materials (Cad weld or similar). | Numbers 61.00 | — | 1,949 | 1,18,889 |
| 111 | For a Four-Line Station | Set 7.00 | — | 32,083 | 2,24,581 |
| 112 | For a Four-Line Station | Set 7.00 | — | 17,141 | 1,19,987 |
| 113 | Preparation of Table of Control based on SIP issued in Auto Cad in A3 size. Initially, contractor shall submit 2 sets of documents for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Railways. After carrying out changes, two sets of Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and two sets of final approved drawing in properly bound booklet along its scanned copy. | Per 300.00 Route | — | 1,004 | 3,01,200 |
| 114 | Preparation of Table of Control based on the approved Signalling Plan as per RDSO Sig DATE Format. AutoCAD in A3 size. Initially, Contractor shall submit 2 set of documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by railways. The TOC & Preliminary Check and Certification to be done by the IRSE or IRSTE (license holder). After carrying out necessary changes, two set of 'Hardcopies' are submitted for administrative approval. The final corrected drawings shall be supplied to Railways on 80/90 GSM Tracing film and 2 copies of blue print properly bonded booklets and the soft copy in USB Pen drive. | Per 300.00 Route | — | 1,388 | 4,16,400 |
| 115 | Independent checking, verification & approval of Logic Circuits of stations of up-to 25 routes by IRSE/ IRSTELO License holders. | Station 7.00 | — | 1,34,748 | 9,43,236 |
| 116 | Additional payment for checking, verifying and approval of Interface Circuits / Logic circuits having more than 25 routes by IRSE/ IRSTELO License holders. (Per Unit = Per Route Per Station ) | Per Unit 50.00 | — | 6,338 | 3,16,900 |
| 117 | Design of circuit diagram for Mid-section LC gates including alteration to the existing station circuit, Signalling plan & TOC (a) Preparation of negatives (b) Printing of 6 sets of LC gates circuit diagrams & station in blue prints with binding including location particulars. (c) Supply of soft copies of LC gate CAD circuits. | LC Gate 12.00 | — | 53,693 | 6,44,316 |
| 118 | Submission of all relevant final 'Asmades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back-to-back in one plastic cover) and handed over to Railways. Also, the contractor has to supply one set of As made in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incorporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. On approval 8 copies shall be made for As- made circuit diagrams also as mentioned above. | Sheet 200.00 | — | 409 | 81,800 |
| 119 | Printing, Binding & supply of the following Registers with latest proforma given by in-charge officer each register of 100 pages. Station Asset Register/Deficiencies Book/Officer Inspection book/ Work site orientation classes note book /Station Message book/Infringement measure book fog signal gears/Route cancellation register/Relay room Key register/Cable testing summary/Signal maintenance record register/Power Systems Battery maintenance Register/Mechanical Signalling Register/Axle Counter Maintenance Register/Block instrument Maintenance Register/Track circuit maintenance Register/Lifting barriers maintenance Register/Electrically operated point maintenance Register/Electronic interlocking Maintenance Register/Location box maintenance Register/Earth Testing record Register/Relay room register/Joint Inspection of Points and Crossings register/Block Proving Axle Counter Register/Diesel generator /SoIar panel Register (Per Unit = Per Register) | Per Unit 9.00 | — | 273 | 2,457 |
| 120 | Digital Multimeter 100 KHz (Hand Held) Brand: RISHABH 18S or similar. | Numbers 3.00 | — | 22,816 | 68,448 |
| 121 | Supply of AC/DC Digital Clamp meter Current measurement upto 200A AC/DC True RMS measurement for AC voltage & current. (Large jaw of size of 18mm) Model: FLUKE 362/Rishabh or higher as per specification. | Numbers 1.00 | — | 6,315 | 6,315 |
| 122 | Supply of Digital Megger with range selection of 500V, 100V. Make RISHABH or similar. | Numbers 3.00 | — | 9,624 | 28,872 |
| 123 | Supply of Digtal Earth Tester Det-1 with metal carrying box and auxiliary earthing net Make Wago or better. | Numbers 1.00 | — | 8,459 | 8,459 |
| 124 | Supply of Rodometer (Distance Recorder) as per latest specification. Make Bosch Model No: 1011662 or better. | Numbers 1.00 | — | 4,218 | 4,218 |
| 125 | Supply of insulated tool kit consisting of 1. 3/8" sq Dr Socket 6mm, 2. 1/2"sq Dr Socket 8mm 3. 1/2"sq Dr Socket 18mm, 4. 1/2"sq Dr Socket 19mm 5. 1/2"sq Dr Socket 20mm, 6. 1/2"sq Dr Socket 22mm 7. SP Spanners 10mm, 8. SP Spanners 12mm 9. adjustable Wrench 8" 10. adjustable Wrench 12" 11. 3/8" Sq Dr Ratchet handle 12. 1/2" Sq Dr Ratchet handle 13. T handle 1/2" 14. Short Extension Rod 1/2" 15. Stanley make Water-Proof Medium Nylon Tool Bag 16. Electricians TRMS digital multimeter FLUKE-117 17. MECO Clamp meter 3690 AC/DC 600A 18. Dummy Wheel-1 No Best Indian make electrical hand gloves suitable for 1000V. Make: Friedrich Germany, INSULA or similar. | Numbers 1.00 | — | 67,480 | 67,480 |
| 126 | Providing Services of helping hand man power to carry out miscellaneous/sundry works in the office/field between 08.00 hrs and 20.00 hrs of the day and accompanying Railway staff with all expenses of transportation, accommodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fess, duties, with contractors tools and plants, materials, consumables, labour, crew, machineries with all lead and lift etc., complete as per special conditions, specification, regulation and as directed by Railway Engineer-in- charge. | Man- 300.00 Days | — | 674 | 2,02,200 |
| 127 | Supply of 20 pair CT box with Disconnecting terminals of Wago/Pheonix/Elmex make or similar. | Numbers 11.00 | — | 4,344 | 47,784 |
| 128 | Fixing of 20 Pair CT box with disconnecting terminals of Wago/Phoenix//Elmex make or similar | Numbers 11.00 | — | 3,439 | 37,829 |
| 129 | Supply of Joint kit for Quad cable conforming to RDSO specification No.IRS- TC 77/2012 Rev 3.0 or latest for quad cable. | Numbers 30.00 | — | 4,023 | 1,20,690 |
| 130 | Provision of normal joint of Heat Shrinkable type complete for 6 quad cables. After the jointing the through cable has to be tested for insulation resistance and loop resistance in presents of Railway Engineer and in case of any defects the jointing has to be done at free of cost by the contractor. [Heat Shrinkable jointing kit conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 covered in the supply portion has to be used for this purpose.] The Contractor should supply all other small items free of cost which are required for making a joint. Only gas blower to be used for blowing | Numbers 30.00 | — | 4,013 | 1,20,390 |
| 131 | Excavation of jointing pit without damaging the fiber and provision of joint chamber of 1.2 mtr dia, 60 Cm height and 50 mm thickness with two-piece top cover and bottom cover. with holes for drainage and cable entry (The reinforcement drawing enclosed). This includes backfilling and ramming of the trench after placing the joint closure and cable loop in the chamber without causing any damage to the same and consolidation of soil as well as disposal of soil as per plan and as advised by RailTel Representative. | Numbers 30.00 | — | 4,626 | 1,38,780 |
| 132 | Supply, transport and filling of the RCC joint chambers with dry sand mixed with ant termite chemical as required in specification up to 400mm height and the cover is refixed in position. | Numbers 30.00 | — | 773 | 23,190 |
| 133 | Supply & Provision of Mid- Section/Derivation OFC Joint enclosure including Splicing (24 Fibre) inside already prepared jointing pit. This does not include provision of Joint chamber, top plate & back filling. The joint Enclosure shall be as recommended in the technical specification | Numbers 20.00 | — | 14,908 | 2,98,160 |
| 134 | Supply of 2T V.F Transformers of 470:1120 ohms or 470:600 ohms or 470:470 ohms as per RDSO spec No. IRS- TC-76-2021 or latest. | Numbers 80.00 | — | 5,893 | 4,71,440 |
| 135 | Supply and installation of 48V,200AH VRLA battery bank as per latest specification No.IRS-S93/96A [One set battery bank contains 24 nos of 2v/200AH cells]. | Numbers 3.00 | — | 1,52,118 | 4,56,354 |
| 136 | Supply of Emergency Socket boxes of FRP type, conforming to specification RDSO/SPN/TC/44/2002 Ver. 3.0 or latest. | Numbers 30.00 | — | 5,687 | 1,70,610 |
| 137 | Supply of 6 pin socket flat as per RDSO Spec. No. IRS/TC/42/20 Ver. 1.0 with latest | Numbers 30.00 | — | 784 | 23,520 |
| 138 | Provision of Emergency communication along the railway track. Fabrication of emergency post as per RDSO Drawing No. UBL/SG/CON/6/2004 and fixing of emergency socket post and burying the post to a depth of 1m after entry of cable. The post to be painted with red oxide before installation. This includes termination of derivation cables on termination strip inside the emergency socket, painting of emergency socket post with alternate black and white strips of 6'' width. The paint used should be of standard quality and two coats of paints should be applied. The EMC post should be painted with red oxide base before painting. (rails will be supplied by railways for the fabrication of emergency post) | Numbers 10.00 | — | 5,851 | 58,510 |
| 139 | Drawing of Switch Board/Power cable through PVC pipe/ Casing capping fixed on the walls, as directed by site InCharge. This work includes termination of cables in the krone connector and fixing of IPM and extending earthing to krone box | Metre 100.00 | — | 14 | 1,400 |
| 140 | Transportation of Signalling materials by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. Transportation up to 100 Kms. | MT-Km 6000.00 | — | 24 | 1,44,000 |
| 141 | Transportation of Signalling materials by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. Transportation more than 100 Kms. | MT-Km 20000.00 | — | 16 | 3,20,000 |
| Schedule total | ₹3,55,68,197 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
I_CT_GCC-
ATTACHMENT
ACS9to12-compressed.pdf
ATTACHMENT
Tender Booklet
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
Tender_booklet_LCClosure_ACS9-11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].