Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹69.8 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹70.3 L+₹49,431.61 (0.71%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹80.3 L+₹10.5 L (15.1%)Admitted-Finance G 15 PKT 2 NARAINA VIHAR NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | L3 | Admitted-Finance | ||
| 4 | L4₹87.3 L+₹17.5 L (25.1%)Admitted-Finance F 2 87 88 ROHINI NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L4 | Admitted-Finance |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
23 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE,ELD-9,DDA
EE,ELD-9,DDA
Supply of EandM material to TPDDL for removal of dark spots under Rohini Zone.
2026_DDA_934642_1
33/ EE/ ELD-9/ DDA/ NIT/ 2026-27
Open Tender
Electrical Works
Works
15 days
Rohini
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹2.4 L
25 Nov 2026
17 Nov 2026
23 Nov 2026
17 Nov 2026
23 Nov 2026
17 Nov 2026
75 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing of MCCB of following Rating and Breaking Capacity with Thermomagnetic Release and Terminal Spreaders etc. complete as required. | |||||
| 1.01 | 4-Pole MCCB, 100 A, 30 KA | 11 | Each | 7,707 | ₹84,777 |
| 1.02 | 4 pole MCCB, 160A, 36kA | 9 | Each | 28,294 | ₹2,54,646 |
| 2 | Supply of Digital Timer Switch etc. complete as required. | 8 | Each | 2,008 | ₹16,064 |
| 3Supply of following Rating Power Contactor conforms to IS/ IEC: 60947-4-1 & IEC 60947-4-1 for Electric Main/ Service Feeder Pillar testing etc. complete as required. | |||||
| 3.01 | 4-Pole Power Contactor of AC-1 Rating 105 Amp | 15 | Each | 14,562 | ₹2,18,430 |
| 3.02 | 4-Pole Power Contactor of AC-1 Rating 200 Amp | 1 | Each | 30,766 | ₹30,766 |
| 4 | Supplying & fixing of 3 x 1.5 sq. mm FRLS PVC insulated Copper Conductor, Single Core Cable for the Existing Surface/ Recessed Steel/ PVC Conduit as required. | 1,550 | Meter | 104 | ₹1,61,200 |
| 5 | Supply of SMC Junction box of inner dimension 250x200x105 in mm with IP-65 protection having provision of terminal board for 3 phase and neutral cable along with holes for incoming and outgoing cables to be fixed on pole with clamps,I-Hooks, nut bolt complete as required. | 488 | Each | 1,433 | ₹6,99,304 |
| 6LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying & testing of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P.F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K(As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Fittings unsuitable to fit in up to 65mm dia pipe shall be summarily rejected. | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.97 MB
BOQ_982159.xls
BOQ • 0.32 MB
NIT33.pdf
Tender Documents • 2.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .