| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.9 L+₹1.4 L (6.82%)Rejected-Finance PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹25.2 L+₹4.7 L (23.0%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹29.5 L+₹9.0 L (43.9%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹33.4 L+₹13.0 L (63.3%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Rejected-Finance Being L5 |
Tender Value
₹46.6 L
EMD Value
₹93,200
Closing Date
26 Jun 2020, 6:00 pmClosed
GE (AF) PALAM, DELHI CANITT-10
GE (AF) PALAM, DELHI CANITT-10
CA NO. GENP-06/2020-21 MANNING AND OPERATION OF CENTRAL AC PLANT IN 3WG TECH AREA AND AFCNWP AND STATION MEDICARE CENTRE AT AF STATION PALAM DELHI CANTT-10
2020_MES_347946_1
GENP-06/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) PALAM
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹93,200
Yes
17 Jul 2020
28 May 2020
27 Jun 2020
29 May 2020
26 Jun 2020
12 Jun 2020
Amount
Operation and Maintenance of central AC Plant of capacity 2 x 15 TR ment for Donier Chitra Laboratries to maintain the required temperature i.e. 20 degree Centigrade + 02 degree Centigrade with relative humidity 50% plus Minus 5% through out the year (7 days in a week round the clock 24 Hrs by deploying one operator ITI Qualified having minimum two years experience in operation of Central AC Plant in three shifts, each shift of eight hours for cooling during summer season. checking and attending normal repair and proper functioning of plant components etc complete all as specified and as directed by Engr-in-Charge. Petty items required for maintenance i.e. cotton waste dausthi white grease/lubricating oil for external moving parts are deemed to be included in the item rates. The plant comprising of the following:- (i) Compressor 13 TR SMC - 4 - 65 with 15 HP electric Motor - 02 Nos (ii) Water circulating pump set mono block 5HP Motor Make: Beacon-02 Nos. One running at a time. (iii) AHU with blower motor 7.5 HP including ducting one lot. (iv) Electrical control panel comprising of starter single phase preventor and inter locking system including cabling - one lot (v) Cooling Tower FRP induced draft round bottle type with CT Motor-One Note:- (i) Maintenance to be carried out as specified and the maintenance record to be submitted to Engr-in-Charge in every month. (ii) Daily log sheet to be maintained as per Appx-A attached.
Operation and Maintenance of central AC Plant of capacity 2 x 50 TR ment for AFCNWP to maintain the required temperature i.e. 20 degree Centigrade + 02 degree Centigrade with relative humidity 50% plus Minus 5% through out the year (7 days in a week in two shifts from 0600 hrs to 2200 hrs by deploying one operator ITI Qualified having minimum two years experience in operation of Central AC Plant in each shift of eight hours for cooling during summer season. checking and attending normal repair and proper functioning of plant components etc complete all as specified and as directed by Engr-in-Charge. Petty items required for maintenance i.e. cotton waste dausthi white grease/lubricating oil for external moving parts are deemed to be included in the item rates. The plant comprising of the following:- Central Type AC Plant 2 x 50 TR (AF CNWP) (i) Scroll Compressor 4 x 12.5 TR with condensers & chiller complete set with controls- 02 Nos. (ii) Water circulating pump set 12.5 HP 02 Nos. (iii) Electric hot water generator Make Rapid Cool - 01 No (iv) Monoblock hot water pump 7.5 HP Make Kirlosker - 02 Nos (v) Monoblock chiller water pump 10 HP - 02 Nos (vi) Monoblock Condenser water pump 10 HP - 02 Nos. (vii) Floor mounted air handling unitof capacity 9000 CFM Make- Air Flow - 01 No. (viii) Floor mounted air handling unitof capacity 10000 CFM Make- Air Flow - 01 No (ix) Ceiling mounted air handling unitof capacity 5000 CFM Make- Air Flow - 05 Nos. (x) Air curtain centrifugal recirculating type of size 2 m wide Make -Superior Alcon - 02 Nos. (xi) LT panel indoor type fitted with MCCB of different rating & starters Make - Advance - 01 No. (xii) LT panel indoor type for AHU units fitted with MCCB of 63 Amps & DOL starters Make - Advance - 07 No. (xiii) Duct made out of GI sheet metal rectangular type with gauge 24/22/20 SWG. - 01 Lot. (xiv) Mild steel water pipe line of size 125/100/80 to 40 mm with fittings - 01 Lot. Note:- (i) Maintenance to be carried out as specified and the maintenance record to be submitted to Engr-in-Charge in every month. (ii) Daily log sheet to be maintained as per Appx-A attached.
Operation and Maintenance of Package type AC 4 x 10 TR meant for AF Signal Section to maintain the required temperature i.e. 20 degree Centigrade Plus Minus 02 degree Centigrade with relative humidity 50% plus Minus 5% through out the year (7 days in a week Two shifts from 0600 hrs to 2200 hrs by deploying one operator ITI Qualified having minimum two years experience in operation of Central AC Plant in each shift of eight hours for cooling during summer season. checking and attending normal repair and proper functioning of plant components etc complete all as specified and as directed by Engr-in-Charge (Supply and fixing of any spare parts required shall be provided by the department through other sources separately). Petty items required for maintenance i.e. cotton waste dausthi white grease/lubricating oil for external moving parts are deemed to be included in the item rates. The plant comprising of the following:- Package Type AC Plant 4 x 10 TR ( AF Signal Section) (i) Air cooled package air conditioner unit cooling capacity 10 TR scroll type compressor complete indoor and outdoor unit make Blue Star - 04 Nos (ii) LT panel with control switches -01 No. (iii) Air duct made out of 24/22/20 SWG - 01 Lot. Note:- (i) Maintenance to be carried out as specified and the maintenance record to be submitted to Engr-in-Charge in every month. (ii) Daily log sheet to be maintained as per Appx-A attached
Operation and Maintenance of Central AC Plant of capacity 3 x 24 TR meant for Donier FTD Bldg to maintain the required temperature i.e. 20 degree Centigrade + 02 degree Centigrade with relative humidity 50% plus/ Minus 5% through out the year (7 days in a week in one shift from 0600 hrs to 1400 hrs by deploying one operator ITI Qualified having minimum two years experience in operation of Central AC Plant in each shift of eight hours for cooling during summer season. checking and attending normal repair and proper functioning of plant components etc complete all as specified and as directed by Engr-in-Charge. Petty items required for maintenance i.e. cotton waste dausthi white grease/lubricating oil for external moving parts are deemed to be included in the item rates. The plant comprising of the following:-. (Central type AC Plant 3 x 24 TR ( Donier FTD Bldg) (i) Scroll type hermetically sealed compressor 2x12 TR each set - 03 Nos. (ii) Chilled water pump capacity 4.9 lps at 26 mtr Make Kirlosker - 03 Nos. (iii) Condenser pump capacity 7 lps at 20 mtr head Make Kirlosker - 03 Nos. (iv) FRP Cooling Tower with all accessories - 01 No. (v) Air handling unit capacity 23600 CFM with filter section, cooling coil of copper tubes heating strip of capacity 3 x 12 KW and 3x6 KW, steel pan humidifier to maintain humidity and ducting - 01 Lot. (vi) LT Panel with incoming 200 Amps MCCB, TPN 35 KA, busbar TPN MCB 16 A, TP -01 No, Starter DOL - 08 Nos, Star delta starter - 03 Nos. (vii) APFC panel of capacity 30 KVAR 415 Volts 50 Hz 4 step complete - 01 No. (viii) Water make up PVC tank capacity 5000 Ltrs 01 No and expansion PVC tank 1000 ltrs. - 01 Set. (ix) Piping chilled and condenser water mild steel class 'C' 100 mm dia, 80 mm dia, 65 mm dia, 25 mm dia - 12 RM - 01 Lot. (x) Valves and accessories - 01 Lot Note:- (i) Maintenance to be carried out as specified and the maintenance record to be submitted to Engr-in-Charge in every month. (ii) Daily log sheet to be maintained as per Appx-A attached.
Operation and Maintenance of Central AC Plant of capacity 3 x 75 TR meant for SMC to maintain the required temperature i.e. 20 degree Centigrade + 02 degree Centigrade with relative humidity 50% + 5% through out the year (7 days in a week round the clock 24 hours by deploying one operator in three shifts of 08 Hrs each. ITI Qualified having minimum two years experience in operation of Central AC Plant in each shift of eight hours for cooling during summer season. checking and attending normal repair and proper functioning of plant components etc complete all as specified and as directed by Engr-in-Charge. Petty items required for maintenance i.e. cotton waste dausthi white grease/lubricating oil for external moving parts are deemed to be included in the item rates. The plant comprising of the following:-. (Central type AC Plant 3 x 75 TR (SMC) (i) Scroll compressor 4X12.5 TR with condensers & chiller complete set with controls-02. (ii) Water circulating pump set 12.5 HP -02 Nos. (iii) Electric hot wwater generator Make Rapid Cool-01 No (iv) Monoblockhot water pump 7.5 HP Make Kirloskar -02 Nos. (v) Monoblock chiller water pump 10 HP -02 Nos. (vi) Monoblock Condenser water pump 10 HP -02 Nos. (vii) Floor mounted air handling unit of capacity 9000 cfm Make-Air Flow-01 No. (viii) Floor mounted air handling unit of capacity 10000 cfm Make-Air Flow-01 No. (ix) Ceiling mounted air handling unit of capacity 9000 cfm Make-Air Flow-01 No. (x) Air curtain centrifugal recirculating type of size 2 m wide Make-Advance -01 No (xi) LT panel indoor type fitted with MCCB of different rating & starters Make-Advance-01 (xii) LT panel indoor type for AHU units fitted with MCCB of 63 Amps & DOL starters Make-Advance 07 Nos (xiii) Duct made out of GI sheet matal rectangular type with gauge 24/22/20 SWG. 01 Lot (xiv) Mild steel water water pipe line of size 125/100/80 to 40 mm with fittings-01 Lot Note:- (i) Maintenance to be carried out as specified and the maintenance record to be submitted to Engr-in-Charge in every month. (ii) Daily log sheet to be maintained as per Appx-A attached.
Notes for item No 01 to 05 (Contd...) : - Note for item No 1.00 to 5.00 of BOQ (i) The cost of petty items required for smooth functioning of installation such as cotton waste, dhoti, grease/lubricating oil, broom for sweeping, uniform to operators, stationery for upkeep of records etc are deemed to be included in the quoted rate of above items. (ii) The contractor shall maintain the attendance register of personnel deployed for the work and the same shall be put upto the Engineer-In-Charge as and when asked. (iii) A complaint register will be maintained by the contractor and obtain the signature of JE/ AGE E/M. Two mobile Nos and one email ID to be maintained by the contractor to communicate the complaints/breakdown. After attending the complaints the contractor will obtain the signature from the AGE E/M every day as token of complaints attended. (iv) The operator should be ITI qualified with 02 years of experience. (v) Contractor shall submit police verification certificates of personnel employed before commencement of works. (vi) Contractor shall provide uniform to the personnel employed without any extra cost to the Deptt. and cost of the same is deemed to be included in the rate quoted of above items and for non wearing of uniform by the personnel employed by the contractor a penalty of Rs. 500.00 shall be levied per person per shift. (vii) The contractor shall ensure proper functioning of safety devices. (viii) The contractor shall stick/paste safety instructions at inside the plants with the contact number of operator/mechanic. (ix) Working hours of a particular team of workers shall not exceed 08 hours per day and no workman shall be allowed to work beyond 08 hours. (x) All the provision of Contract Labout Act shall be strictly adhered to.
Notes for item No 01 to 05 (Contd...) : - (xi) Prior to commencement of work, copy of valid Electrical License in the name of the contractor or copy of agreement in the agency having valid Electrical License alongwith agencies Electrical Licenses shall be submitted by the contractor to the Accepting Officer through Engineer-in-Charge. In case contractor does not possess valid Electrical License & he intends to get such work executed through agency having valid electrical license & whom he has agreement, prior approval of such agency shall be got done from Accepting Officer. Copy of license shall be kept on record by Engr-in-Charge for future reference (xii) For absence of manpower on any manning day a recovery of twice the amount of existing minimum fair wages of the particular category shall be recovered from the contractors dues. (xiii) The contractor/firm will have to make payments to their staff / employees by cheque or through NEFT in their bank account. No payment to contractor / firm will be made, unless proof of payment of wages through bank account is submitted by the contractor / firm. (xiv) The Government of India vide their Notification No F.No 1/36(3)/2019-LS-II dated 23 Sep 2019 has notified minimum fair wages to be paid to the labour. The rate analysis has been done based on minimum fair wages which is kept in the office of GE. If the contractor quotes rates less than minimum fair wages, then the fixed deposit of the difference amount rounded up near one thousand i.e. Amount based on Rate Analysis prepared on minimum wages Minus (-) Quoted Rates by the contractor, will be deposited for a period of 05 years before Acceptance in favor of GE (AF) Palam, Delhi Cantt. The Accepting Officer has full power to accept any tender as per rates in vogue. The rates quoted by the tenderer shall include the above provisions and nothing extra will be paid on these accounts.
M/s Durga Traders
SM CONSTRUCTION COMPANY
airstack india
M/s Adhikari construction co.
M/s KUNDU CONSTRUCTION
M/S MAISUR CONSTRUCTION COMPANY PRIVATE LIMITED
SNOWY ENGINEERING INC
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .