Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC SANTOBI MATA GALI MURSAN HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | L1 | Accepted-AOC Accept | |
| 2 | L2₹6.2 L+₹2.4 L (60.3%)Rejected-AOC GIJJROLI AGRA ROAD HATHRAS UTTAR PRADESH 204101 INDIA | HATHRAS | HATHRAS | UTTAR PRADESH | 204101 | L2 | Rejected-AOC Accept | |
| 3 | L3₹6.3 L+₹2.4 L (62.6%)Rejected-AOC BAMNA HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | L3 | Rejected-AOC Accept | |
| 4 | L4₹6.9 L+₹3.0 L (77.7%)Rejected-AOC | L4 | Rejected-AOC Accept | |
| 5 | L5₹9.0 L+₹5.1 L (130.8%)Rejected-AOC | L5 | Rejected-AOC Accept |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
13 Sept 2021, 12:00 pmClosed
SE EDC Hathras
SE EDC Hathras
Work Giving Supply of Oxygen Plants Full Deposit Work under EUDD Hathras
2021_DVVNL_616894_1
EDCH-92/2021-22
Open Tender
Electrical Works
Item Rate
30 days
SE EDC Hathras
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
DVVNL
₹15,000
8 Feb 2022
4 Sept 2021
13 Sept 2021
4 Sept 2021
13 Sept 2021
4 Sept 2021
Amount
Safe Carriage of following material from Electricty store center Hts to Pit site of work through the Kacha and Pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-50 Kms.)
9/11 Mtr. S.T. Poles
33 KV Pole Mounted Metering Units CTR 40/1 Amp
33 KV XLPE cable 3*300 Sqmm
LT XLPE Cable Al 3.5*300 Sqmm
11 KV X-Arms, weasal conductor, G.I wire,Disc Insulators, Pin insulators, clamps Abc Bunch and other required line material, if any.
Safe Carriage of following from Electricty Store center Hathras to Pit Site of Work through the Kacha and Pakka road loading and unloading at the respective ends including the cost of arrangement of labour, T&P, etc. which required for proper completion of work.(Distance 00-70 Kms.)
400 KVA T/F
Errection of following Poles including Cutting of kharanja/mettalic road/concrete portion while digging pit & complete H.T./L.T. fittings as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Double pole with complet fitting
Grouting of ST Pole (wherever required) with cement, sand and brick ballast/stone ballast in ration 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. As per actual site requirement.
Fixing & Jumphering of 33 KV Pole Mounted Metering Units CTR 40/1 Amp
Errection and grouting of stays as per RESPO Norms and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Fixing of earthing rod as per RESPO Norms and as per direction of supervising engineer.
Providing & Fixing of 140mm O/D Pn-4 PE-80 Grade UV Stablized HDPE pipe as per IS: 4984 in 6 Meter
Laying, sagging and stringing and jumpering / binding etc. of new & old ACSR Weasal conductor / GI in 11 KV / LT lines as per RESPO manual and as per direction of supervising engineer.
LT PVC Cable 400 KVA
ACSR Dog / Racoon Conductor
LT XLPE Cable Al 3.5*300 Sqmm
33 KV XLPE cable 3*300 Sqmm
Earthing by way of boring and lowering of "B" class GI Pipe 50 mm dia. Into the ground upto the water level (Minimum 30 meter deep) to the lower end of which a slid copper cone approx 9 inches long and 750 gram in weight providing and screwed in connecting and bringing out continuous copper wire 8 SWG from the cone to the ground surface where it will be bolted to the MS Earth Strip of T/P neutral connection. The earth strip will be welded to the GI pipe. The work also includes providing cap and clamp for pouring water, the cost of all material with all labour and T&P etc. complete in all respect.
Construction of plinth of size 5' * 5 * 4' above ground level one ft below the ground level of 9" After Exavation of 4 "earth brick ballast shall be provided and rammering will be done properly After ballast shall be provided and rammering will be done properly After that a retaining wall 9"width by fist class brick in ratio 1:4 of cement & sand shall be made . The earth shall be filled up to one ft.below the top of the plinth After this brick ballast shall be provided upto 6"from the earth level and proper rammering shall be done one No. jall of 12 mm MS tor shall be fixed in the hollow of plinth and one ft. thick RCC in ratio of cement sand & stone ballast shall be laid on the top of the plinth. The 12 mm thick plastering shall be done all round the plinth in 1:4 ratio of cement and sand.
Earthing of medium Power Transformers
Net Fencing Shall be 1150*1200 mm made of 35*35 mm MS Angle covered by expended netal 14 SWG up to full Height 1200 mm duly steftened by MS flat by an 8 SWG dia bolt & nut
INSTALLATION OF LIGHTENING ARRESTORS With Structure:- Assembling and installation/mounting of 3 Nos lightening arrestors on the LA structure/Terminal Gantry complete with making earth connections (separate) and line connections. The work also includes providing & fabrication of 3 nos MS plates of size 300x450 mm, 10 mm thick for placing lightening.
INSTALLATION OF POST INSULATOR/C.T.s With Structure:- Installation of 3 Bis Post insulators/C.T.s on the structures. The work also includes providing & fabrication of 3 Nos MS plates of size 300x450 mm, 10 mm thick for placing post insulation/CTs if required.
INSTALLATION OF FUSE SET:- Assembling and installation of fuse set on the fuse set structure. The work includes fabrication of proper fixing if required.
Terminal gentry to line isolator through lightening arrestors/33 KV post insulators.
Providing & Fixing of Philler Box
Construction of cable trench having internal size 230 x 230 mm with 115 mm brick wall (Ist class) in ratio 1:6 Cement mortor both side upto 230 mm height including excavation of earth and 75 mm CC work in foundation ratio 1:6:12 including plastering on both sides of the brick wall and upper side CC foundation in 1:2:4 M.S. flat of size 35x6 mm be fixed at a height of 150 mm after fabrication by cutting & drilling of 2 Nos holes 6 mm dia. The top cover shall be provided over the trench with 40 mm thick stone plate (patia) resting on both sides of trench.
Fixing of following accessories.
33 KV Disc Insulator with fitting.
33 KV Pin with insulator
Danger Board
Cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer
Installation of following T/F on newly constructed double pole in proper alignment direction & making HT/LT connection.
400 KVA T/F
Providing and Fixing of 33 KV Cable Jointing Kit as per site requeriment
Laying of 33 KV XLPE Cable in the Cable Trunch and Filing the earth after Completion of Job
PAINTING OF STRUCTURE:- Painting of the following structures with one coat of ready mixed primer and two coats of Aluminium paint of good quality including cost of material, labour and T&P complete in all respect.
Isolator Structure
L.A./Post Insulator/C.T./Fuse Set Structure.
Round Pole Plinth
Installation of extra ''T'' on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, T&P etc, required for proper completion of work. The "T" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material.
SUMIT ENGINEERING
Bobby Electricals
SHRI GANESH ENTERPRISES
ABG ENGINEERS
Divy Electrical Engineering
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .