Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Not Admitted-Fee B 2 A FIRST FLOOR EAST VINOD NAGAR EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | - | Not Admitted-Fee Fee not received | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Eligible | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Eligible | |
| 5 | Rejected-Technical DOOR NO 31 T S NO 5 2 LAKE VIEW BUILDING VETTRI NAGAR WATER CANAL ROAD KOLATHUR CHENNAI TAMIL NADU 600099 | CHENNAI | TAMIL NADU | 600099 | - | Rejected-Technical Not Eligible |
Tender Value
₹9.1 L
EMD Value
₹18,236
Closing Date
27 Dec 2019, 6:00 pmClosed
AGM Engg Electrical RHQ NER
AGM Engg Electrical RHQ NER Guwahati.
SITC of Boom barrier
2019_AAI_37883_1
Provision of Boom Barrier for AAI Resdntl colony
Open Tender
Electrical Works
Works
45 days
AAi Residentil Colony Guwahati
As per NIT
3 documents required · 3 mandatory
₹1,120
GM AAI
₹18,236
6 Feb 2020
13 Dec 2019
6 Jan 2020
14 Dec 2019
27 Dec 2019
14 Dec 2019
14 Dec 2019 - 19 Dec 2019
Amount
SH I : Boom Barrier
SITC of electromechanical manual / remote operated traffic aluminium boom barrier of following length complete with main machine controller unit with IP 54 protection enclosure, boom rest, base plate, fixing hub with base plate and fixing bolts & nuts , barrier, photo sensor , warning lights along with all necessary associated accessories including 1 KVA single phase stabilizer etc. suitable for operation on 230 V, single phase, 50 Hz AC Power supply system, installation at the existing entry gate with suitable concrete pedestal, interconnection testing and commissioning etc as required.
a) 3 Mtr length
b) 4 Mtr Length
SH II : S/L of Cable and associated works
Supply of 4C X 16 sqmm size of 1.1 KV grade, XLPE insulated PVC sheathed armoured Aluminium conductor cable confirming to IS 7098(part -I) 1988 amended upto date.
Supplying and making end termination with brass compression gland and aluminium lugs for 4C x 16 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
a) Upto 35 sq. mm
Laying & fixing of one number PVC insulated & PVC sheated/ XLPE power Cable of 1.1 KV grade of size upto 35 sq.mm (clamped with 1mm thick saddle) on wall surface as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size up to 35sq. mm size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Supplying and laying of 50 mm dia. size, PN6 PE80, Rigid HDPE pipe ISI marked along with all accessories like socket, bends, couplers etc., conforming to IS 4984:1995 complete with fittings & jointings including excavating the paved road/cement concrete of size not exceeding 0.2 mtrs width and 0.5mtrs depth, providing cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and disposal of excess soil as directed within lead of 50mtrs etc., as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and fixing of following ways surface/ recess mounting, horizontal type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of suitable tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) i/c cable termination end box as required .
a) 4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying & Fixing 5A to 32A rating, 240/415 V, 10KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
a) Double pole
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .