| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC 88 197 B CHAMAN GANJ KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.4 L+₹2,635 (0.14%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹19.2 L+₹83,291 (4.54%)Rejected-Finance 39 W 1 ASHOK VIHAR SAKET NAGAR KANPUR 208014 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208014 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected being firm removed by HQ CELZ Lucknow Zone |
Tender Value
₹19.9 L
EMD Value
₹39,800
Closing Date
18 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I KANPUR
GE I KANPUR CARIAPPA ROAD KANPUR CANTT 208004
CLEANING OF SEWAGE LINE SEPTIC TANK MH REPLACEMENT REPAIR OF SEWAGE LINE MH COVER AND MH COVER ETC IN VRG LINE SUPPLY DEPOT HARDING ROAD NAPIER ROAD ME LINE COD ESTATE UNDER AGE BR I GE I KANPUR
2020_MES_358023_2
GE(I)/KAN/T-36 OF 2020-21
Open Tender
Civil Works
Item Rate
330 days
Kanpur Cantt
Class E category a i
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹39,800
Yes
24 Sept 2020
4 Aug 2020
20 Aug 2020
4 Aug 2020
18 Aug 2020
13 Aug 2020
60 days
Amount
M & L for Cleaning/removal of blockage of floor traps/nahani traps of 75 mm/ 100mm bore in kitchan/bathroom/toilets etc up to 1st Manholeincluding of PVC/ Stainless trap greeting and refixing the same with white cement with pigment to match the surface as before or any other associated /related complains not mention under this item and will be done as directed by Engr -in-Charge. Note - : The Traps shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M & L for Cleaning /removal of blockage of Gully traps up to 1st Manhole of any size and any depth including removing RCC covers and refixing the same as before or any other associated /related complains not mention under this item and will be done as directed by Engr -in-Charge. Note - : The Gully Trap shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M & L for Cleaning /removal of blockage of Orissa pattern WC 'P'/'S' traps and make functioned up to 1st Manhole or any other associated /related complains not mention under this item and will be done as directed by Engr -in-Charge..Note - The WC shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M & L for Cleaning /removal of blockage of Europian type WC 'P'/'S' traps and make functioned up to 1st Manhole or any other associated /related complains not mention under this item and will be done as directed by Engr -in-Charge..Note - : The EWC shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M & L for Cleaning /removal of blockage of Europian type WC 'P'/'S' traps including removing EWC and cleaning the taps completely and make functioned and rifitted the EWC in same position including making good the distrubed surfaces with the help of white cement and pigment to match the existing surface or any other associated /related complaints not mention under this item and will be done as directed by Engr -in-Charge.Note - : The EWC shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
M & L for Cleaning /removal of blockage up to 200 mm bore SWG/RCC pipes including Man Hole of depth not exc 1.50 mtr using Mechanized / Mechnical means incl removing RCC man hole covers and refixing the same as before all complete and as specified by Engr-in-Charge.Note :- Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge
M & L for Cleaning /removal of blockage up to200 mm bore SWG/Rcc pipesincluding Man Hole of depth exc 1.50 mtr but not exc 3.00 mtr using Mechanized / Mechnical means incl removing RCC man hole covers and refixing the same as before all complete and as specified by Engr-in-Charge.Note :- Length will be measured from previous manhole to subsquent manhole in RM for payment purpose after satisfaction of Engr-in- Charge
M & L for Dewatering/desilting of existing manholes of internal size n exc 0.80mx0.80m depth n exc 1.50m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion)and incl removing RCC manhole Covers and refixing the same after cleaning the same position, complete all as directed by Engineer-in-charge.
M & L for Dewatering/desilting of existing manholes of internal size n exc 1.00mx1.00m depth exc 1.50m but n exc 3.00m and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion)and incl removing RCC manhole Covers and refixing the same after cleaning the same position, complete all as directed by Engineer-in-charge.
M & L for Dewatering/desilting of existing Septic Tank/Soakage Well incl removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system at contractor's discretion or using suction pump where ever required up to any depth by working under foul conditions and disposal of the same in out of MoD area, complete all as directed by Engineer-in-charge for the following sizes Note - : The Septic tank shall be measured more than one time as per requirment and directed by Egnr-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles.
M&L Brick work with sub Class ‘B’ bricks straight or curved on plan exceeding 6 mm mean radius built in cement mortar 1:4, complete all as specified.
M&L Rendering 15 mm thick with WPC on fair face of brick work conc surface in CM 1:4 mixed even and smooth without extra cement including necessary scaffolding, complete all as specified.(Note WPC Shall be measured seprately)
Demolition of cement concrete (reinforced ) of any description in ground floors and paving not exceeding 15 cm thick (below or above the ground level).complete all as specified and removed from site as directed by Engr-in-Charge
Providing pre-cast reinforced cement concrete type B-1, 1:2:4 using (20 mm graded aggregate) as in manhole covers, complete all as specified.
M & L for MS TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia all as directed and specified.
M & L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100 mm bore pipe, complete all as specified.
Demolition of cement concrete (un-reinforced ) of any description in ground floors and paving not exceeding 15 cm thick (below or above the ground level).complete all as specified and removed from site as directed by Engr-in-Charge
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 meter in depth for shitting sewage lines including trimming of sides etc, complete all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and exceeding 1.5m not exceeding 3.00 meter in depth for sewage lines including trimming of sides etc, complete all as specified.
M & L for Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth in soils, complete all as specified.
M & L for Removal excavated material to distance not exceeding 100 metre and depositing where directed at level not exceeding 1.5 metre above the starting point in soil, complete all as specified.
Demolition and breaking up drain pipes 100/150/200mm bore (salt glazed ware, AC or reinforced) set in cement mortar including bedding benching/ haunching, complete all as specified and removed from site as directed by Engr-in-Charge
M&L Plain cement concrete (1:4:8), type D-2, using 40mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&LPlain cement concrete (1:4:8), type D-2, using 40mm graded stone aggregate as in bed to drain pipes of 150 mm bore including packing under and hunching against the sides of pipes after they are laid and tested, complete all as specified.
M&LPlain cement concrete (1:4:8), type D -2, using 40mm graded stone aggregate as in bed to drain pipes of 200 mm bore including packing under and hunching against the sides of pipes after they are laid and tested, complete all as specified.
M&L of Reinforced concrete pipes, class NP2, 150 mm bore laid and jointed complete with collars’ jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified
M&L of Reinforced concrete pipes, class NP2, 200 mm bore laid and jointed complete with collars’ jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified
Dismantling of cast iron drain pipes & fittings, jointed in cmenet mortor and taking out of trench required internal dia of pipe 75 to 100mm.
S&F 100mm bore cast iron soil waste and vent pipe (spun pipe) in any length with or without ears with cement joints fixed to walls/ceiling or laid in floor.
S&F 75mm bore cast iron soil waste and vent pipe (spun pipe) in any length with or without ears with cement joints fixed to walls/ceiling or laid in floor.
S&F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls /ceiling or laid in floor complete.
S&F in repair 110mm bore PVC (SWR) bends any radius.
S&F in repairs CI Nahnai trap 100 mm complete all as specified and directed.
S&F in repairs CI Tee for 110 mm bore pipe complete all as specified and directed.
S&F in repair CI vent cowl of size 75 mm dia complete all as specified and directed.
M&L Plain cement concrete ( 1:2:4), type B-1, (using 20 mm graded stone aggregate) as in surface channels and drains, benching of manholes laid to shape including necessary form works, complete all as specified.
M & L for Extra for forming fair finished drain or channels 30 cm inner grith in cement concrete, using extra cement incl form moulds mittred / stopped end etc complete all as specified.
M & L for Plain cement concrete ( 1:2:4), type B-1, (using 20 mm graded stone aggregate) as in coping bedplates & other similar works, including necessary form works wearthering, slightly rounded angles and theading, complete all as specified.
M&L for 7 to 8 mm thick ceramic coloured printed tiles joint free (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc; laid jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles over Screed bed or bedding layer of cement mortar 15 mm thick for laying floor finishes in CM 1:6.over 25 mm thick PCC Type B0 1:2:4 (12.5 mm graded agg) as in leveling /sub base of flooring and complete all as specified and directed.
Supply and fixing in repair vitreous china squatting pan 'Orrisa pattern' size 580x440mm white with integral foot rests any pattern and making connection with & including PVC P/S Trap, etc PCC 1:5:10 type E-2 using 40 mm graded brick aggregate as in bedding and making good disturbed surface complete all as specified and directed. Make : Hindware/Cera/Parryware as approved by GE.
Supplied and fixed in repair vitreous chinaware EWC padestal type closet with white seat including cover with flat bottom with hinging device all as specified and directed. Make : Hindware/Cera/Parryware as approved by GE.
M&L for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base to floor finished fair & even all as specified and directed by Engineer-in-charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness , M-35 grade, set, jointed over 25 mm thick sand cushoning all as directed by Engineer-in-Charge.
M&L for chequered cement concrete tiles 25cm x 25cm x 22mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement & pigments over and including 15 mm thick in CM (1:4) complete all as specified and as directed by Engineer-in-Charge.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) and clearing rubbish off the premise complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x450x6 to 7 mm thick on vertical surfaces such as skirting/dado set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 10mm thick rendering in CM (1:4) complete all as specified and directed.
.Applicable for all items: Notes 1 : ( for relevent Items ) :If It is not feasible for access of mechanized system for cleaning of line/ MH/ other associated work, same will be executed as per direction of Engr-in-Charge. Decision of inaccessibility of mechanised system shall be decided by Engr -in- Charge and shall be final. Note 2 : All safety precautions will be as per government policies in vogue shall be adhered by contractor. Note 3: All T&P, mask,safety equipments and other items required at site under subject contract shall be provided by Contractor.
M/s S K ARORA
N. K. ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .