Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC NOT FOUND | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.6 L+₹25,613.55 (4.07%)Rejected-Finance H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹6.7 L+₹43,816.45 (6.96%)Rejected-Finance CC III 28A JANTA BHAWAN ROAD SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹6.8 L+₹45,571.45 (7.23%)Rejected-Finance NEAR S B O P WARD NO 1 SURDULGARH MANSA | SURDULGARH | MANSA | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹6.9 L+₹61,275.80 (9.73%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
5 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SIRSA
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (AF), SIRSA, HARYANA-125055
GE/SRA/T-42(A)/2023-24
2023_MES_631729_1
GE/SRA/T-42(A)/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹24,000
Yes
25 Jan 2024
8 Dec 2023
6 Jan 2024
8 Dec 2023
5 Jan 2024
22 Dec 2023
9 Dec 2023 - 15 Dec 2023
Amount
SCHEDULA 'A' PART-I (B/R WORKS) Demolition Cement Concrete (Reinforced) of Roofs, Floors (other than Ground Floors), Beams, Staircases, Landing, Chajjas and similar Suspended Work (Reinforcement cut as required to facilitate demolition) and removing debris, etc. to Outside of MD/AF Land, complete all as specified and as directed.
M&L Reinforced Cement Concrete 1:1½:3 Type A-1 (20mm graded stone aggregate) as in Chajjas,facia,lintels and Similar Items, complete all as specified and as directed. NOTE : Reinforcement will be Measured and Paid under appropriate Item.
M&L Formwork to Chajjas and Similar Items including edges, Flat, Rough finished surfaces of Concrete, complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cutting, bending, hooking ends and binding with MS wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed.
Taking down damaged/unserviceable Steel/aluminium/PVC window with frame not exc. 1.50 Square Metre Each with shutter( without taking off shutter from the frame), complete all as specified and as directed.
S&F aluminium window double shutter with provision of booking window if necessary glazed and gauged of galvanised mild steel wire cloth nominal dia of wire 0.56mm and average width of aperture 1.18mm along with aluminium section with 50 micron anodizing size of frame 125mm X 44.5 mm size of shutter, top, bottom and side rail 44.5mmx44.5x16mm gauge aluminium section with 50 micron anodizing and 5mm thick black/tinted sheet glass to be fixed on glazed portion and stainless steel hooks and eye to be provided as stay of shutter etc complete incl necessary jointing cleats, glazing clips, rubber packing attached aluminium snap beading, screws,aluminium grill, anodized aluminum fitting such as peg stay 150mm long (01 No. for each leaf) hinges type B-21 100mm long (02 Nos for each leaf) suitable handle (01 No for each leaf) and 100mm aluminium tower bolts (02 Nos in each leaf), brush weather strip,complete all as specified and directed. (NOTE: Quoted rate shall be deemed to include for the cost of 5 mm thick tinted sheet glass)
Repairing of Aluminium door, windows, ventilators shutter fixed/ side hang,sliding type /partition including replacement of necessary jointing cleats, glazing clips, Rubber Neoprene packing, Aluminium snap beading, screws etc and repairing of Locking Arrangement if any, complete all as specified and as directed. Note:- Quoted unit rate shall deem to be include jointing cleats, glazing clips, Rubber Neoprene Packing, Aluminium Snap Beading, screws etc. required/ordered for necessary fixing at site.
M&L Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples and Fixed-in-repairs, complete all as specified and as directed.
Taking down Shutter of any description, exc. 1.00 Sqm but not exc. 2.00 Sqm Each, complete all as specified and as directed.
S&F for powder coated aluminium anodised door shutter with frame 101.40x44.45mm including jointing cleates and fixing accessories, size of long rails/style, top and middle/centre rail shall be 84.40x44.45mm and bottom rail shall be 110x44.45mm of aluminium sheet shall be 16 gauge, panels shall be provided with 5mm thick sheet glass and 12mm thick PVC sheet best quality including locking arrangement fixed with hinges to the frame or slidng type or pull & push type shutters including glazing clip, rubber gasket and aluminium beading, 150mm long aluminium handle-02 Nos, mortice lock - 01,brush weather strip, complete all necessary fittings and fixtures all as specified and as directed. (NOTE: Quoted rate shall be deemed to include for the cost of 5 mm thick sheet glass and 12 mm thick PVC sheet)
S&F mild steel Mortice lock,100mm size vertical type, 4 levers, complete all as specified and as directed.
Demolition Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed.
M&L for 25 mm thick cement concrete type B-0, 1:2:4 (12.5mm graded stone agg) as in floors, complete all as specified.
M&L for Cement Concrete 1:4:8 type D2 (40mm graded stone aggregate), 100mm thick, as in Sub-bases, complete all as specified and as directed.
M&L for Cement Concrete 1:4:8 type D2 (40mm graded stone aggregate), 75mm thick, as in Sub-bases, complete all as specified and as directed.
M&L for Cement Concrete 1:2:4, type B1 (20mm graded stone aggregate) 75mm thick as in Path / Hardstanding, laid in alternate Bay / Panel, finishing Cement Concrete surface Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L for Cement Concrete 1:2:4 type B1 (20mm graded stone aggregate) as in Coping, Bed Plates, Holdfast, Bed Block, Kerb Stones including necessary Formwork and weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
Dismantling boarding or any thickness, any description ,fixed in any position with nails complete all as specified and as directed.
S&F 5mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
S&F 5mm thick Prelam PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and solid PVC Partitions inclusive of solvent Cement and fixing at site complete all as specified and as directed.
M&L for dismantling floor tiles alongwith screed bed, removal of debris outside AF land, cleaning of area to remove dust, loose particles, washing with water and providing Floor (Paver) Tiles 300 x 300 x 9.0 to 10mm, highly abrasive, Anti-skid, Impact Resistant, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate.
M&L for dismantling floor tiles alongwith screed bed, removal of debris outside AF land, cleaning of area to remove dust, loose particles, washing with water and providing Non-skid/matt finish Ceramic tiles, coloured, joint free, 7 to 8 mm thick (Square/rectangular), area of each tile exceedig 0.11 Sqm but not exceeding 0.18 Sqm in Flooring, set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the tiles, laid over and including Screed Bed 15mm thick in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate.
M&L for taking down wall tiles alongwith screed bed, removal of debris outside AF land, cleaning of area to remove dust, loose particles, washing with water and providing Coloured/Printed Glazed Ceramic Tiles, 450x300x7mm thick in Vertical Surfaces i.e. Dado, Skirting, etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, fixed over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:3, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate.
M&L Dismantling Stone Slabs and/or Tiles of any description or thickness in Floors, Aprons, etc. laid, bedded and pointed in Cement Mortar, removal of debris outside AF land, cleaning of area to remove dust, loose particles, washing with water and providing Granite (of any type) Tiles, 16-18mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement and admixture of pigment to match the shade of granite stone including grinding and polishing, laid over and including 20mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be included in the Quoted Unit Rate.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc and removal of debris outside AF land complete all as specified and directed.
M&L for Rendering (Internal) 15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, surfaces finished Even and Smooth without using Extra Cement complete all as specified and as directed.
M&L for Rendering 5.0mm thick in Cement Mortar 1:3 on Concrete Surfaces of Ceilings, Plastered Surfaces finished even and fair complete all as specified and as directed.
M&L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid seperately as "Supply only".
Supply only Integral Water Proofing Compound, conforming to IS and/or as approved, complete all as specified.
S&F in repairs false ceiling with powder coated exposed G.I. grid suspension system consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle, wall angle fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c, Main Runners placed @ 1200mm, Cross Tee 1200mm inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm and additional cross tees of 600 mm placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm, grid of module size 600mm x 600mm shall be supported by 6 mm dia G.I. wire from purlins/soffit including providing 4mm thick HPSC cement fibre decorative building boards, duly fixed on ceiling grid with clips, screws etc complete all as specified and directed. Note: Cost of Ceiling board shall be deemed to be included in the quoted rates.
M&L preparing newly Plastered Surfaces of Ceiling and applying Three Coats of White Wash, complete all as specified and as directed.
M&L preparing old Plastered Surfaces of Ceiling and applying Two Coat of White Wash, complete all as specified and as directed.
M&L preparing Old Decorated/Treated Plastered Surfaces of Walls and applying Two Coat of White Wash, complete all as specified and as directed.
M&L preparing newly Plastered Surfaces of Walls by applying 1.5 mm thick Wall Putty including Rubbing down with Sand Paper to obtain a Smooth Finish Surface and applying Two Coats of Acrylic Distemper (of approved tint) over a Coat of Primer, complete all as specified and as directed.
M&L preparing old Decorated/Treated Plastered Surfaces of Walls and applying One Coat of Acrylic Distemper (of approved tint), complete all as specified and as directed.
M&L preparing old Decorated/Treated Plastered Surfaces of Walls and applying Two Coats of Acrylic Distemper (of approved tint), complete all as specified and as directed.
M&L for preparing New Plastered Surfaces of Walls by applying a Coat of Chalk Whiting (as Preparatory Treatment) and applying Two Coats of Weather Coat Exterior Emulsion Paint over a coat of cement primer with approved Tint as per manufacturer's instructions, complete all as specified and as directed.
M&L preparing old Decorated/Painted Wood and Wood Based Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed.
M&L preparing old Decorated/Painted Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed.
M&L Galvanised Tubes 15mm bore (dia), 'medium grade', with all Fitting and fixed complete to Walls and Ceilings or laid in Floors, including taking up or down and segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and as directed.
S&F in repair Bib Tap 15mm bore (dia), Cast Copper alloy, Fancy type Chromium Plated with Crutch or Butterfly Handle, screwed down, screwed for Iron Pipe and Wall Flange, complete all as specified and as directed.
S&F Rotational Moulded Polyethene Water Storage Tank 500 Litre Capacity, Cylindrical, Vertical with Closed Top, 3 layered, hoisted and fixed in Position including dismantling / lowering down unserviceable Water Storage Tanks, complete all as specified and as directed.
S&F Ball Valve 20mm dia (minimum Weight 210 Gram), high pressure of PTMT with epoxy coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe, complete all as specified and as directed.
S&F in repair Gun Metal Gate Valve 20mm bore (dia) with Iron Wheel Head including Flange, screwed both Ends for Iron Pipe, complete all as specified and as directed.
S&F in repair Sink with Drainage Board made of Stainless Steel 1.0mm thick Kitchen or Laboratory Overall size 1000x510mm having Bowl size 460x410x200mm with Plugs, Washers and waste coupling and PVC waste pipe, etc. including bedding in Cement Mortar to dwarf Wall or including fixing Cantilever Brackets and connecting Union to Pipe, complete all as specified and as directed.
S&F in repair Vitreous china, white, half stall urinal flat back with grating and union for discharge pipe (excl flush pipe and flushing cistern and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and Union for discharge pipe complete all as specified and directed.
S&F in repair brass chromium plated Urinal spreader for fixing with 15 mm dia pipe complee all as specified and as directed.
S&F in repairs PVC Flushing Cistern 10 Litre capacity White, Low Level, Valve less, Syphonic action type with Inlet, Ball Valve, Float and Handle, PVC Waste Pipe 32mm bore (dia) of suitable Length, a pair of Cast Iron Bracket/ Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in CM 1:3, complete all as specified and as directed.
S&F in repair 15mm bore heavy duty PVC connector pipe of length 600mm with PTMT coupling at both ends, screwed down for pipe as directed by Engineer-in-Charge.
S&F in repair 15mm bore dia, fancy type, chromium plated, Angle valve cock, complete all as specified and as direcetd.
M&L for bringing suitable approved earth from outside AF land and forming embankments or earth filling including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and directed. NOTES :- (1) Earth required for embankment/filling shall be of approved quality and shall be brought from outside the AF land by contractor under his own arrangement. No extra shall be admissible on this account. (2) Quoted rate shall be deemed to included for all labour required for excavation, removing the soil, loading and unloading, transportation to site, making temporary profiles, levelling etc. (3) Density of finished earth in embankment, traverse etc shall be as directed by GE/Engr-in-Charge. (4) Necessary deduction for voids in terms of Para 3.6 on Ser page No 21 of SSR Part-II, 2020 (Rates) shall be carried out from the finished quantity of earthwork. Contractor's quoted rate shall be deemed to be inclusive of the above aspect and no claim shall be entertained at a later date in this regard.
All as per item No. 51 but exc. 1.5 m and n. exc 3.0 m high from base
All as per item No. 51 but exc. 3.0 m and n. exc 4.5 m high from base
SCHEDULE 'A' PART-II (INT ELECTRIFICATION WORKS) Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down/out unserviceable Wires only from the existing Sub-main Wiring of any type and any description, without disturbing Existing Conduit, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size( as required) duly painted with Red Oxide Metal Primer with 2.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed. (NOTES :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be deemed to be inclusive of the cost of terminal box & laminate cover. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
-Ditto- as item No 56 but for ONE 5 PIN SOCKET OUTLET 6 AMP ON THE SAME BOARD, complete all as specified and as directed.
-Ditto- as item No 56 but for ONE 5 PIN SOCKET OUTLET 6 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 2.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed. (NOTES :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be deemed to be inclusive of the cost of terminal box & laminate cover. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
All as per item No. 60 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
All as per item No. 60 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
S&F Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC CONDUIT complete all as specified and as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits)
S&F Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in PVC CONDUIT complete all as specified and as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits)
S&F Switch piano, flush type, single pole. 6 Amps, one way complete all as specified and directed.
S&F socket outlet, flush type. 5 pin, 2-in-1, 6 Amps complete all as specified and directed.
S&F switch socket combination outlet, flush type, 2-in-1, 6 Amps complete all as specified and directed.
S&F switch socket combination outlet, flush type with indicator lamp, 20 & 10 Amps complete all as specified and directed.
S&F Ceiling rose, surface type, three terminals, 240 volts %0 Hz complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 5 speed control complete all as specified and directed.
S&F lamp holder with back plate, PVC/Polycarbonate body, suitable for batten fittings or to be mounted on walls complete all as specified and directed.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, 110 lumen/watt, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed.
-ditto- as per Item No. 72 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
-ditto- as per Item No. 72 but of 1 X 05 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
S&F LED Bulkhead fitting 09/10 watt, with IP65 degree of protection and with impact resistance of IK-08, mounted on wall /ceiling connected with insulated unsheathed flexible copper wire of suitable size complete all as specified and directed.
NOTE FOR ITEM NO. 72 to 75 :- (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work. (2) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete incl lamps from the date of completion of work. The product will be replaced free of cost in following cases :- (a) Manufacturing Defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 metre) below 90% of claimed value of lumen (or lux at 1 metre) of the LED/luminaire. (d) Decision of GE in this regard shall be final and binding. (3) All LED/luminaire shall meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/Section 13. (4) The contractor shall submit the LM-80 and LM-79 test report (except decorative fitttings) as specified in Particular Specifications. (5) Any touch up of the wall surface due to changing of fitting shall be done by contractor with similar surface finish without extra cost to the department.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
S&F Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.
S&F Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 4 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed.
S&F MCB, 'C' series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with and including 1 No. MCB Single Pole, 20 Amp, 240 Volt and Connecting up complete all as specified and as directed.
STAR CONSTRUCTIONS
M/s Satguru Traders
M/s MANN CONSTRUCTIONS
M/s Har Nandi Construction Company
YESH BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .