Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.4 LAccepted-AOC | 1 | Accepted-AOC Lowest 1 Bidder | |
| 2 | 2₹14.0 L+₹57,450 (4.28%)Rejected-AOC | 2 | Rejected-AOC Not the lowest 1 Bidder |
Tender Value
₹14.1 L
EMD Value
₹28,289
Closing Date
14 Dec 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Senior Superintending Engineer
CSIR NCL DR Homi Bhabha Road Pashan Pune 411008
Electrcical Renovation of Room No.186, 192,207,278 and 285 at CSIR NCL.
2024_CSIR_217649_1
Elect/Reno186,192,207,278,285
Open Tender
Electrical Works
Works
90 days
CSIR NCL Pune
As per NIT
3 documents required · 3 mandatory
₹500
Director NCL
₹28,289
13 Jan 2025
4 Dec 2024
16 Dec 2024
4 Dec 2024
14 Dec 2024
4 Dec 2024
4 Dec 2024 - 13 Dec 2024
Amount
( Light / Exhaust point in M.S.conduit) Wiring for light point/ceiling fan point / Exhaust Fan point with PVC insulated, copper conductor wires of size 2 x 1.5 Sq.mm, 1100 V grade,FRLSH (Red/Yellow/Blue colour for phase & Black colour for Neutral ) and 1.00 Sq.mm, 1100 V grade,FRLSH green colour wire for earth continuity conductor Finolex / RPG /Polycab :-Make in 20 mm dia. & 16 SWG thick M.S. conduit pipe with required essential M.S. conduit accessories such as Inspection bend / Jn.box/check nut etc Make :- BEC & white colour ceiling rose . The light point is with SITC of SP Modular switch 6A Legrand Myrius NexGen/MK Bleng Plus with Modular front plate suitable for 6 A.S.P.switch & PVC/Metal surface box. ( In Laboratoris)
Wiring for circuit wiring with PVC insulated copper conductor wires of Size 2x2.5 Sq.mm,1100V grade,FRLS (R-Y-B for phase & black colour for neutral) and 1 x 1.5 Sq.mm,1100v grade green colour wire for earth continuity conductor Finolex/ RPG/Polycab:-Make in 20 mm diam.& 16 SWG thick M.S. conduit pipe with required essential M.S. conduit accessories such as Inspection bend / Jn.box/check nut, Make :- BEC.Also to run 2x16swg Bare copper wire as earth conductor.
Wiring for circuit wiring with PVC insulated copper conductor wires of Size 4x2.5 Sq.mm,1100V grade,FRLS (R-Y-B for phase & black colour for neutral) and 2 x 1.5 Sq.mm,1100v grade green colour wire for earth continuity conductor Finolex/ RPG/Polycab:-Make in 20 mm diam.& 16 SWG thick M.S. conduit pipe with required essential M.S. conduit accessories such as Inspection bend / Jn.box/check nut, Make :- BEC.Also to run 2x16swg Bare copper wire as earth conductor.(Rate for this Item should include cost of material & labour charges required for complete execution of Item)
Wiring for circuit wiring with PVC insulated copper conductor wires of Size 2x4 Sq.mm,1100V grade,FRLS (R-Y-B for phase & black colour for neutral) and 1 x 2.5 Sq.mm,1100v grade green colour wire for earth continuity conductor Finolex/ RPG/Polycab:-Make in 20/25 mm diam.& 16 SWG thick M.S. conduit pipe with required essential M.S. conduit accessories such as Inspection bend / Jn.box/check nut, Make :- BEC. Also to run 2x16swg Bare copper wire as earth conductor. ( Rate for this Item should include cost of material & labour charges required for complete execution of Item)
Wiring for circuit wiring with PVC insulated copper conductor wires of Size 4x4 Sq.mm,1100V grade,FRLS (R-Y-B for phase & black colour for neutral) and 2 x 2.5 Sq.mm,1100v grade green colour wire for earth continuity conductor Finolex/ RPG/Polycab:-Make in 20/25 mm diam.& 16 SWG thick M.S. conduit pipe with required essential M.S. conduit accessories such as Inspection bend / Jn.box/check nut, Make :- BEC.Also to run 2x16swg Bare copper wire as earth conductor.( Rate for this Item should include cost of material & labour charges required for complete execution of Item)
Supplying & fixing 6Amp 2 in 1 modular socket & 6A switch MK Blenz Plus/Legrand Myrius Next Gen make on wall or on lighting control board complete with MS surface box & Modular plate.
(SITC of Modular Switch board for power point ) Supplying,fixing,connecting fully prewired modular system type Legrand( Myrius NextGen )/MK Blenz Plus :- Make switch board with following specifications. a) Moulded front plate with 12/16 module Cat no 673305),:---01 no. b) White powder coated metal mounting box suitable ,for 16 module front plate(Cat No 679516).---01 no. c) 6 A. S.P.switch ( w/o indicator), Code No.679200:-03 nos. d) 6Amp 5 pin Module, universal type socket,Code No.679228 :- 03 nos. c) 16 A. S.P.switch, Code No.679209:-01 nos. d) 16 Amp/6Amp 3Module, universal type socket,Code No.67679229 :- 01 nos.
Supplying, fixing & connecting on ceiling prewired LED light fitting Surface 4' x 1' Type 30-36Watts Philips make cat No.SM270C LED 30S 6500K PSU WH 32 watts/ Wipro Make Cat No.AURA PLUSCRCO13S038HP57G1, 30Watts/Havells' Make Cat.No.PLANO Surface, 5700k, 4'x1 with suspension kit upto 1.5 mtr, complete with Driver.The fitting should be hung from the ceiling by using suspension kit fixed to the ceiling.The LED Light fiting should have minumum 3 years replacement warranty. (For Laboratories)
Supplying,Installation, testing and commissioning of Industrial type, heavy duty Exhaust fan of 380mm, (15")sweep,1400RPM .Model:-Turboforce SP,Make:-Havells (or Equivalent model of GE/Crompton ) The rate includes :- Supply of 3-core PVC flex.copper cond. cable, Anchor fastner of suitable size,25mm thick waterproof plywood for fixing Ex.fan or by fabricating suitable size of M.S. angle / flat frame. (For laboratories)
Supplying & laying on wall/ cable tray PVC armoured cable, 2 core x 4sqmm, Polycab /Gloster /Asian Make, copper conductor, 1.1Kv grade at NCL site. (Before supplying cable, actual measurement at site should be taken in consultation with site engineer.) The cable should be fixed to the tray with M.S. screws.(Working tables)
Supplying & laying on wall/cable tray PVC armoured cable, 4 core x 4 sqmm, Polycab /Gloster /Asian Make, copper conductor, 1.1Kv grade at NCL site. (Before supplying cable, actual measurement at site should be taken in consultation with site engineer.) The cable should be fixed to the tray with M.S. screws. (For Fume hoods)
Supplying & laying on wall/cable tray PVC armoured cable, 3.5 core x 35sqmm, Polycab /Gloster /Asian Make, Aluminium conductor, 1.1Kv grade at NCL site. (Before supplying cable, actual measurement at site should be taken in consultation with site engineer.) The cable should be fixed to the tray with M.S. screws.
Termination of 2 core, 4 Sqmm Copper conductor armoured cable with suitable size of Copper crimping type lugs into the existing power DB and other end into load. The siemens type cable gland should be used for termination of cable
Termination of 4 core, 4 Sqmm Copper conductor armoured cable with suitable size of Copper crimping type lugs into the existing power DB and other end into load. The siemens type cable gland should be used for termination of cable
Termination of 3.5 core, 35 Sqmm Akuminium conductor armoured cable with suitable size of Aluminium crimping type lugs into the existing power DB and other end into load. The siemens type cable gland should be used for termination of cable
Fabricating,painting,supplying,fixing on wall with anchor fastners box type cable tray of Size 200 mm width x 75 mm deep made from 16 SWG CRCA sheet. The cable tray should have 16 SWG CRCA sheet cover throughout its length with proper screwing. The tray should be powder coated with Siemens Grey colour.The tray should be provided with suitable cable fixing arrangement inside the tray. (Before fabrication of cable tray layout should be decided & actual measurement at site should be taken in consultation with site engineer.){For main cables to working tables}
Fabricating,painting,supplying,fixing on wall with anchor fastners box type cable tray of Size 75 mm width x 50 mm deep made from16 SWG CRCA sheet. The cable tray should have 16 SWG CRCA sheet cover throughout its length with proper screwing. The tray should be powder coated with Siemens Grey colour.The tray should be provided with suitable cable fixing arrangement inside the tray. (Before fabrication of cable tray layout should be decided & actual measurement at site should be taken in consultation with site engineer.) {For power cables}
Supplying & fixing in metal enclosure DPMCB 32 Amp, Legrand/ Siemens/ Hager make on wall complete with connections & testing.
Supplying & fixing in metal enclosure FPMCB 32 Amp, Legrand/ Siemens/ Hager make on wall complete with connections & testing.
Supplying & fixing completely assembled MDS make main PowerVTPN distribution board, 3 phase 8way with 4 pole Lexic make MCB 63A cat No608702--1No as incomer & TPMCB 25-32A- 3Nos. & 15Nos of 6-20A SPMCBs Lexic make as O\G. The distribution box should be fixed on wall with Anchor fastners. Enclosure should be double door type with IP 43 potection Legrand make,Cat No.507727 with cable end boxes. Rate is inclusive of Lexic make metal enclosure,MCBs & cable end boxes. (DGDB at Lab )
Supplying & fixing on T.W. Board Main SPN Distribution board Legrand Ekinox make 12 way cat no:5076112 with 1 no. of Legrand make DP Lexic MCB 40 A,cat no. 408746 as I/c & 12 nos of 6-25A SPMCBs 10KA breaking capacity as O/G. Rate is inclusive of enclosure, MCBs & connections. Separate Connector should be provided for neutral & Earthing.(For LDB near 278 Supply)
Dismantling the existing light, fan,bell, plug point carefully without damaging the fittings.The dismantled material should be returned to the NCL stores at no extra cost.
Dismantling the existing cables or mains of all types & sizes & refilling the holes woth cement morter & finishing in an approved manner.
AMOL ELECTRICAL (BID ID -787115)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .