| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 CrAccepted-AOC | ₹37.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹37.4 CrRejected-Finance | ₹37.4 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹37.9 CrRejected-Finance | ₹37.9 Cr | L3 | Rejected-Finance L3 |
Tender Value
₹30.7 Cr
EMD Value
₹40.7 L
Closing Date
4 Oct 2022, 1:00 pmClosed
Executive Engineer-I
MPHC Office complex
Development of Sangai Ethnic Park in Bishnupur District, Manipur.
2022_MPHCL_1935_1
04/EE-I/MPHC/2022-23
Open Tender
Civil Works
60 days
Please refer tender documents
As per tender documents
11 documents required · 11 mandatory
₹25,000
MD MPHC
₹40.7 L
21 Aug 2024
16 Sept 2022
4 Oct 2022
16 Sept 2022
4 Oct 2022
17 Sept 2022
17 Sept 2022 - 28 Sept 2022
Amount
(a) Construction of Main Gate-Entrance to Ethnic Park )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 Kanhaighat coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 Kanhaighat coarse sand)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design.
Apply AGR Fibre mix with c.m. 1:4
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Providing with treated Flatten & Solid Bamboo Structure made using Bambusa Balcooa (with minimum thickness 8mm to 10mm Size 80mm (+/-10mm) diameter ) Bamboo or equivalent treated with reservative inside the bamboo pole & dosing with Boric - Borax treatment using pressure through vacuum treatment plant with retention level 6kgs per Cum in accordance with IS 9096 (Group-A bamboo pole) Bambusa Balcoa 3 to 4 year age of culm with minimum wall thickness of 10mm & distinctive inter-nodes 450mm max. All exposed bamboo surface will be polished with Polyurethane coating of quality brand with first coat with sealer and second coat of finish final coat. 2. Half split Bamboo of 25feet length (Cladding on MS Frame)
(b) Providing and fixing of Sangai Head Frame )
Providing and fixing of Sangai Head Frame as per approved Design and Specification.
(b) Providing and fixing of Sangai Head Frame )
(Sh: Providing IEI in the Main Gate Entrance- Ethnic Park)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
P/L 25 mm2 4 - core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 250mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC of Recess mounted adjustable LED downlights made of extruded Al. housing and high power LED as a light source with clear diffuser and separate elctronic driver SPARKLEPROADJDLR30W830MOD40D.
SITC R-18, 90W RGB Flood Light outdoor i/c connection etc. as reqd.
SITC 160 watt LED High bay with excellent heat sink along with IP66 protection perfect solution for outdoor applications i/c connections etc. as reqd. Havells JETAIRISFLS 160W LED 757 PW BLTG.
S/F bus bar chamber with 4 strips copper bus bar length 300mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
P/F 125 amp. TPN stand ground on load change over switch (Compact design) 415/500V including connection etc as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 2 :- Construction of Compound Wall - Ethnic Park)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
BRICK WORKS
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
STONE WORKS
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 Kanhaighat coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 Kanhaighat coarse sand)
R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Boring , Providing and installing cast in situ single piles of specified diameter and length below pile cap in M20 cement concrete , to carry a safe working load not less than specified , including the cost of steel reinforcement , boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete ( Length of pile payment shall be measured upto the bottom of pile cap i/c dismantling of cast pile for 0.30 m at the top (a)300 mm dia pile (i) 3.00 m depth
Providing and fixing M.S Grill of SHS 25x 25 x 2.60 mm square bars , horizontally and vertically M.S Flat 50x 6 mm at base and vertical position on R.C.C. member of compound fencing comforming to architecture drawing including applying priming , painting coat etc. complete .
(SH 3 :- Construction of Information Center )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
(b)1:2:4 (1 cem :2 Kanhaighat Coarse sand:4 graded stone aggrt.20mm n/size).
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Local best quality teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality teak wood
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand: : 6 stone aggrt. 20mm nominal guage).
Providing & fixing M.S. grills of required pattern in frames of window etc with M.S. flats, square or round bars etc i/c priming coat with approved steel primer all complete.(a) Fixed to openings/ wooden frames with rawl plugs screws etc.
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm
Providing and fixing bright finished brass handles with screws etc.complete :. (a) 125mm
Providing and fixing bright finished brass hard drawn hooks and eyes.(a) 150mm
Providing and fixing stainless steel (grade 304 ) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered e/c fixing accessories such as nuts, bolts, fasteners etc )
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 Kanhaighat coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size i) Size of Tile 600x600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Granite 12.5mm thick in risers of steps , skirting , dado walls and pillars laid on 10 mm thick base of cement mortar 1 : 3 ( 1 Cement: 3 Kanhaighat coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete (a) Black/Green
SH : FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
Designing, fabricating,testing, installing and fixing in position Curtain wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including; a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel materials consisting of 3mm thick FR grade mineral core sandwhiched between two Aluminium sheet (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coild coated, with Kynar 500 based PVDF/Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (service) coating on face # 2 as specified using strainless steel screws, nuts, bolts, washers, cleats, weather silocone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 TS/MS with hot Dip Galvanised with serrations and serrated
washers to arrest the wind load movement, fasteners, SS 316 pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all materials & labour componenet, the cost of all mock ups at site, cost of all samples of the individualk components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frane work for ACP cladding is payable under the relevant aluminium items. The contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-charge. However, for the purpose of payment, only the actrual area on the external face of curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.complete.
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a)precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I seam bolts and nuts, G.I plain and bitumen washers complete : Ridges plain (500 - 600mm) (a) precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel
with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
(Sh: Providing IEI in the Information Centre)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in presto plast casing & capping etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 5/16 amps switch
© 15/16 amps switch
(d) 6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC surface mounted LED downlighter with white powder coated Al.housing with intrgrated electronic driver 15 W 840 LHEAAGPIA2W012 complete with connection etc as reqd.(Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 4 :- Construction of Ticket Counter )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Local best quality teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality teak wood
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand: : 6 stone aggrt. 20mm nominal guage).
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm
Providing and fixing bright finished brass handles with screws etc.complete :. (a) 125mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Granite 12.5mm thick in risers of steps , skirting , dado walls and pillars laid on 10 mm thick base of cement mortar 1 : 3 ( 1 Cement: 3 Kanhaighat coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete (a) Black/Green
SH : FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing glazing in aluminium door,window,ventilator,shutters and partition etc. with EPDM Rubber Neoprene gasket etc complete with float glass paints of 4 mm thick with frames of aluminium hollow tube of 50 x 50 mm and angle of 25 x 40 mm fastened with stainless steel screws, nuts bolts washers cleats weather silicon sealant backer rods etc.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a)precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
(Sh: Providing IEI in the Ticket Counter)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades with regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 5 :- Construction of Pathway Paving )
(SH:- (i) Footh path Type -A)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : -(b) 1 : 3 : 6 (1 cem : 3 Kanhaighat Coarse sand : 6 graded stone aggrt. 40mm nominal size).
Boulder filling dry hand packed tightly as in pitching and vertical bunds with sloping face.
Providing and laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic ore other deleterious constituent spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150 mm (spread thickness)
(SH:- (i) Footh path Type -B)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : -(b) 1 : 3 : 6 (1 cem : 3 Kanhaighat Coarse sand : 6 graded stone aggrt. 40mm nominal size).
Providing and laying 60 mm thick factory made cement concrete interlocking paver block (Rubber Moulded) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design / shape laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of the Engineer-in-charge
Stone masonry work in cement mortar I :3 for substructure (b) coursed rubble masonry (first sort) complete as per drawing and Technical Specifications
Providing and laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic ore other deleterious constituent spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150 mm (spread thickness)
(Sh: Providing IEI in the Pathway Paving)
S/F swaged type steel tubular pole 8 mt.long as per 410-SP-14 conforming to IS-2713 (Pt-II) 1980 with bracket in cement concrete 1:3:6 (1 cem.:3 c/sand : 6 gr. St. 40mm n/size) foundation i/c excavation and refilling etc. as reqd.
S/F L.T. cross arm 50X50X6mm - 2 wires
S/F back clamp for L.T. pole
S/F stay set complete with stay wire & stay insulator etc.as reqd.
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Cost of 2.5mmm2 FR pvc insulated multistranded cu. Cond. Flexible cable.
SITC LED Street Light 60W 757K made of pressure dia housing with toughned glass and individual high power LED with secondary optics IP66 protection & impact resistance of (Havells) ENDURAPEARLPLUSL60W complete with all accessories i/c connection etc. as reqd.
Design,supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of four way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 200 amp. TPN on load changeover switch - 1 No.
2. 200 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 4 Nos.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/L 50 mm2 4 - core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 250mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Earthing with copper plate 600x600x6mm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for charcoal and salt for G.I.plates or copper plate earth electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH7 :- Construction of Main Stage )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 Kanhaighat coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 Kanhaighat coarse sand)
Providing joists (karries) including hoisting fixing in position and applying wood preservative on unexposed surface etc. complete with:a) Uningthou wood
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Apply AGR Fibre mix with c.m. 1:4
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 kanhaighat coarse sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 kanhaighat coarse sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 kanhaighat coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Boring , Providing and installing cast in situ single piles of specified diameter and length below pile cap in M20 cement concrete , to carry a safe working load not less than specified , including the cost of steel reinforcement , boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete ( Length of pile payment shall be measured upto to top of pile cap i/c dismantling of cast pile for 0.50 m at the top) i) 450 mm diameter pile for 6.00 metre.
(Sh: Providing IEI in the Main Stage)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 25 mm2 4 - core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 250mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 9W LED bulb
SITC of Recess mounted adjustable LED downlights made of extruded Al. housing and high power LED as a light source with clear diffuser and separate elctronic driver SPARKLEPROADJDLR30W830MOD40D.
SITC R-18, 90W RGB Flood Light outdoor i/c connection etc. as reqd.
SITC 160 watt LED High bay with excellent heat sink along with IP66 protection perfect solution for outdoor applications i/c connections etc. as reqd. Havells JETAIRISFLS 160W LED 757 PW BLTG.
S/F bus bar chamber with 4 strips copper bus bar length 300mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
P/F 125 amp. TPN stand ground on load change over switch (Compact design) 415/500V including connection etc as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 8 :- Construction of Green Room )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Local best quality teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality teak wood
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand: : 6 stone aggrt. 20mm nominal guage).
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm
Providing and fixing bright finished brass handles with screws etc.complete :. (a) 125mm
Providing and fixing bright finished brass hard drawn hooks and eyes.(a) 150mm
Providing & fixing M.S. grills of required pattern in frames of window etc with M.S. flats, square or round bars etc i/c priming coat with approved steel primer all complete.(a) Fixed to openings/ wooden frames with rawl plugs screws etc.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.: In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 Kanhaighat coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size i) Size of Tile 600x600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
SH : FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat coarse sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel
with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes i) 75 mm diameter
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I, rain water pipes embedded in and including cement concrete blocks 10x10x 10cm of 1:2:4 mix (1 cement: 2 Kanhaighat coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : b) 100 mm diameter.
Supplying and applying Dr. Fixit primeseal (after making dilution with water in the ratio 2:1 ( 2 primesial : 1 water ) on new roof at 1 litre per 9.3 sqm after cleaning the surface using wire brush or approprite tools (surface to be washer off with water)and allow drying of 2 -3hours before applying Dr. Fixit New coat over this coat as per direction of the Engineer - in -charge.
Supplying and applying Dr. Fixit New coat on primeseal roof surface in three different coats at 1 litre per 1.95 sqm . per coat laying fibre mesh with adhesive primer ( consuning 20 litre for 80 sheet of 3 x 10 m fibre mesh ) after 1 st coat of new coat 2nd coat of newcoat should be applied immediately after laying of fibre mesh 3rd coat of Dr. Fixit newcoat should be applied after allowing drying of the 2nd coat for 6 to 8 hrs. Each coat should be applied in perpendicular direction to the underlaying layer. the entire process should be carried out under strict supervision and direction of the Engineer - in -charge.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 Kanhaighat coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx 1mx 400 micron, finished with 12mm cement plaster 1:3 (1cement : 3 Kanhaighat coarse sand) and a coat of neat cement , rounding the edge and making and finishing the outlet complete.
(Sh: Providing IEI in the Green Room)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in presto plast casing & capping etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 5/16 amps switch
© 15/16 amps switch
(d) 6 pin 15/16 amps socket outlet
P/L 25 mm2 4 - core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 250mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 9W LED bulb
SITC surface mounted LED downlighter with white powder coated Al.housing with intrgrated electronic driver 15 W 840 LHEAAGPIA2W012 complete with connection etc as reqd.(Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
S/F bus bar chamber with 4 strips copper bus bar length 300mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
P/F 125 amp. TPN stand ground on load change over switch (Compact design) 415/500V including connection etc as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 9 :- Construction of Museum )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 Kanhaighat coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 Kanhaighat coarse sand)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 kanhaighat coarse sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 kanhaighat coarse sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing transparent Arcylic Sheet
(Sh: Providing IEI in the Museum)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 9W LED bulb
SITC of Recess mounted adjustable LED downlights made of extruded Al. housing and high power LED as a light source with clear diffuser and separate elctronic driver SPARKLEPROADJDLR30W830MOD40D.
SITC R-18, 90W RGB Flood Light outdoor i/c connection etc. as reqd.
SITC 160 watt LED High bay with excellent heat sink along with IP66 protection perfect solution for outdoor applications i/c connections etc. as reqd. Havells JETAIRISFLS 160W LED 757 PW BLTG.
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 10 :- Construction of Restaurant)
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 Kanhaighat coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 Kanhaighat coarse sand)
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 Kanhaighat coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size i) Size of Tile 600x600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Granite 12.5mm thick in risers of steps , skirting , dado walls and pillars laid on 10 mm thick base of cement mortar 1 : 3 ( 1 Cement: 3 Kanhaighat coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete (a) Black/Green
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
SH : FINISHING
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design.
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing and fixing Asphalt sheet
Providing with treated Flatten & Solid Bamboo Structure made using Bambusa Balcooa (with minimum thickness 8mm to 10mm Size 80mm (+/-10mm) diameter ) Bamboo or equivalent treated with preservative inside the bamboo pole & dosing with Boric - Borax treatment using pressure through vacuum treatment plant with retention level 6kgs per Cum in accordance with IS 9096 (Group-A bamboo pole) Bambusa Balcoa 3 to 4 year age of culm with minimum wall thickness of 10mm & distinctive inter-nodes 450mm max. All exposed bamboo surface will be polished with Polyurethane coating of quality brand with first coat with sealer and second coat of finish final coat. 1. Flatten Bamboo
(Sh: Providing IEI in the Restaurant)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F fancy wall bracket suitable for 1X9W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc. as reqd.
S/F 9W LED bulb
SITC R-18, 90W RGB Flood Light outdoor i/c connection etc. as reqd.
SITC 160 watt LED High bay with excellent heat sink along with IP66 protection perfect solution for outdoor applications i/c connections etc. as reqd. Havells JETAIRISFLS 160W LED 757 PW BLTG.
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH11 :- Construction of Handloom Stall )
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing & fixing of Metal Shingles panel for roofing characterised with ASTM class A fire rating,with wind resistance in corporating with IECC solar reflectance index with minimum vapor permeance of 15 under high temperature along with compatible metal fasteners
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
TUBULAR TRUSSES/STEEL/ALUMINIUM WINDOWS
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
FLOORING
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
(Sh: Providing IEI in the Handloom Stall - 6 nos.)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F fancy wall bracket suitable for 1X9W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc. as reqd.
S/F 9W LED bulb
SITC R-18, 90W RGB Flood Light outdoor i/c connection etc. as reqd.
SITC surface mounted LED downlighter with white powder coated Al.housing with intrgrated electronic driver 15 W 840 LHEAAGPIA2W012 complete with connection etc as reqd.(Havell's)
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH12 :- Construction of DG and Electrical Room )
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
BRICK WORKS
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces.
TUBULAR TRUSSES/STEEL/ALUMINIUM WINDOWS
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
FLOORING
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 Kanhaighat coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size i) Size of Tile 600x600 mm
Providing & fixing of Metal Shingles panel for roofing characterised with ASTM class A fire rating,with wind resistance in corporating with IECC solar reflectance index with minimum vapor permeance of 15 under high temperature along with compatible metal fasteners
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design.
FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
MISCELLANEOUS
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel
with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
Steel glazed windows and ventilators of standard rolled steel section joints mitred and welded with 15 x 3 mm lugs 10 cm long with steel plugs embedded in cement concrete block 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 kanhaighat Coarse sand : 6 stone aggregate 20 mm nominal size) or wooden plugs and screws of rawl plugs and screws or with fixing clips with bolts and nuts as required including providing and fixing of 4 mm thick glass panes with glazing clips complete including applying a priming coat of approved steel primer excluding cost of metal beadings and other fittings except necessary hinges or pivots as required.b) Ready made steel windows (side hung/top hung)
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
(Sh: Providing IEI in the DG & Electrical Room)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 9W LED bulb
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH13 :- (a) Construction of Traditional Hut - (Type - A) )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with100 mm thick AAC blocks in super structure above plinth level up tofloor V level in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand ).
SH : FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design.
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Supplying and providing of Façade.
Supplying & Fixing of Palmex Synthetic Thatch Roofing with Ridges including installation and all other accessorie charges etc. complete.
(Sh: Providing IEI in the Traditional Hut Type-A - 17 Nos.)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X1.5mm2+1X1.5mm2 earth wire
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F fancy wall bracket suitable for 1X9W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc. as reqd.
S/F 9W LED bulb.
P/F 32 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size hylum fibre board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 13 :- (b) Construction of Traditional Hut- (Type - B) )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. \ (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with100 mm thick AAC blocks in super structure above plinth level up tofloor V level in cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand ).
SH : FINISHING
Cement concrete flooring 1:2:4 (1 cement: 2 Kanhaighat coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Supplying and providing of Façade.
Supplying & Fixing of Palmex Synthetic Thatch Roofing with Ridges including installation and all other accessorie charges etc. complete.
(Sh: Providing IEI in the Traditional Hut Type-B - 17 Nos.)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X1.5mm2+1X1.5mm2 earth wire
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F fancy wall bracket suitable for 1X9W LED lamp with glass/annodized wall bracket complete with all accessories i/c connection etc. as reqd.
S/F 9W LED bulb.
P/F 32 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size hylum fibre board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 14 :- Construction of Exit Gate from Ethnic Park)
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 Kanhaighat coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 Kanhaighat coarse sand)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing & fixing 19 mm thick cement fibre board for cushion of roofing as per approved design.
Apply AGR Fibre mix with c.m. 1:4
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
(Sh: Providing IEI in the Exit Gate)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
P/L 25 mm2 4 - core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 250mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
SITC of Recess mounted adjustable LED downlights made of extruded Al. housing and high power LED as a light source with clear diffuser and separate elctronic driver SPARKLEPROADJDLR30W830MOD40D.
SITC R-18, 90W RGB Flood Light outdoor i/c connection etc. as reqd.
SITC 160 watt LED High bay with excellent heat sink along with IP66 protection perfect solution for outdoor applications i/c connections etc. as reqd. Havells JETAIRISFLS 160W LED 757 PW BLTG.
S/F bus bar chamber with 4 strips copper bus bar length 300mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
P/F 125 amp. TPN stand ground on load change over switch (Compact design) 415/500V including connection etc as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 15 :- Construction of Public Toilet (Male) )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Local best quality teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality teak wood
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand: : 6 stone aggrt. 20mm nominal guage).
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm
Providing and fixing bright finished brass handles with screws etc.complete :. (a) 125mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 Kanhaighat coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size i) Size of Tile 600x600 mm
Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Makrana white second quality.
Marble chips skirting (upto 30 cm height) rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume :18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand): Dark shade pigment with ordinary cement with extra for marble stone flooring in treads of steps and risers using single length upto 2.00 metre .
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
SH : FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.(a) Electric resistant welded tube (Conforming to IS : 1611 - 1979).
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a)precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
(Sh: Providing IEI in the Public Toilet (Male)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades with regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F 12W LED bulb.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 16 :- Construction of Public Toilet (Female)
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Local best quality teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality teak wood
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand: : 6 stone aggrt. 20mm nominal guage).
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm
Providing and fixing bright finished brass handles with screws etc.complete :. (a) 125mm
Providing and laying vitrified tiles in different sizes (thickness 8 mm thick) with water absorption less than 0.08% and conforming to IS 15622,of approved make ,in all colours & shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 c/sand),i/c routing the joints with white cement & matching pigments etc,complete (i)size of tile-600x600mm (Double harged)branded
Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Makrana white second quality.
Marble chips skirting (upto 30 cm height) rubbed and polished to granolithic finish, top layer 6 mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from smallest to 4 mm nominal size laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume :18 mm thick with under layer 12 mm thick in cement plaster 1:3 (1 cement: 3 Kanhaighat coarse sand): Dark shade pigment with ordinary cement with extra for marble stone flooring in treads of steps and risers using single length upto 2.00 metre .
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
SH : FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrom primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete.(a) Electric resistant welded tube (Conforming to IS : 1611 - 1979).
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
Trapzoidal Pre-painted Profile Sheet roofing of approved brand DYNA Roof or equivalent with self drilling screws of 68 mm long Xylon coated screws with PVC washer & caps complete,excluding the cost of purlins & trusses.Pre painted Galvanished Iron Sheet (PPGL) i) Profile sheet 0.50 mm /4.2 kgs/sqm
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
(Sh: Providing IEI in the Public Toilet (Female)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades with regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F 12W LED bulb.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 17 :- Construction of Security Barrack )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Local best quality teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality teak wood
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand: : 6 stone aggrt. 20mm nominal guage).
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm
Providing and fixing bright finished brass handles with screws etc.complete :. (a) 125mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Granite 12.5mm thick in risers of steps , skirting , dado walls and pillars laid on 10 mm thick base of cement mortar 1 : 3 ( 1 Cement: 3 Kanhaighat coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete (a) Black/Greene
SH : FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing glazing in aluminium door,window,ventilator,shutters and partition etc. with EPDM Rubber Neoprene gasket etc complete with float glass paints of 4 mm thick with frames of aluminium hollow tube of 50 x 50 mm and angle of 25 x 40 mm fastened with stainless steel screws, nuts bolts washers cleats weather silicon sealant backer rods etc.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.complete.
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a)precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
(Sh: Providing IEI in the Security Barrack)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades with regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 18 :- Development of Replica of Loktak Lake )
Construction of chain link compound fencing with steel Framework(1.52 m Ht)
(SH 19 :- Construction of Steel Structures along Pathway )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
(SH 20 :- Construction of R.C.C. Drain and Culverts )
(SH:- (i) R.C.C. Drain Type -A)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
FINISHING
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
(SH:- (ii) R.C.C. Drain Type -B)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
FINISHING
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
(SH:- (iii) R.C.C. Culvert )
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
(b) 1 : 3 : 6 (1 cem : 3 Kanhaighat Coarse sand : 6 graded stone aggrt. 40mm nominal size).
R.C.C. WORKS
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(SH 21 :- Construction of 20 S.M. Barrack )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Local best quality teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality teak wood
Providing and fixing M.S. round or square bars with M.S. flats at required spcing in wooden frames of windows and clerestory windows.
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand: : 6 stone aggrt. 20mm nominal guage).
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm
Providing and fixing bright finished brass handles with screws etc.complete :. (a) 125mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 Kanhaighat coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size i) Size of Tile 600x600 mm
SH : FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 Kanhaighat sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat sand) with a floating coat of neat cement inside & outside as per standard design.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.complete.
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a)precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I seam bolts and nuts, G.I plain and bitumen washers complete : Ridges plain (500 - 600mm) (a) precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
(Sh: Providing IEI in the 20 S.M. Barrack)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F surface/pendent mounting 1x18 W LED lamp channel luminaries complete with all accessories and connection etc as reqd.
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades with regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power COB LED as light source Havell's JETACOMPECT OF 50W LED 757LTG complete with connection as rqd. (Havell's)
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F 12W LED bulb.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 22 :- Construction of Kitchen cum Dining hall )
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
BRICK WORKS
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
WOOD WORKS
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Local best quality teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality teak wood
Providing 40x5mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand: : 6 stone aggrt. 20mm nominal guage).
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm
Providing and fixing bright finished brass handles with screws etc.complete :. (a) 125mm
STEEL WORKS
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.complete.
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
TUBULAR TRUSSES/STEEL/ALUMINIUM WINDOWS
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. Electric resistance or induction butt welded tubes
FLOORING
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 Kanhaighat coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size i) Size of Tile 600x600 mm
ROOFING & CEILING
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a)precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I seam bolts and nuts, G.I plain and bitumen washers complete : Ridges plain (500 - 600mm) (a) precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade.(a) two or more coats on new work.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat c/sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
(Sh: Providing IEI in the Kitchen and Dining Hall)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F surface/pendent mounting 1x18 W LED lamp channel luminaries complete with all accessories and connection etc as reqd.
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades with regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power COB LED as light source Havell's JETACOMPECT OF 50W LED 757LTG complete with connection as rqd. (Havell's)
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F 12W LED bulb.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
( SH 23 :- Construction of Toilet block 3W.C. & 3Bath )
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
(b) 1 : 2 : 4 (1 cem : 2 Kanhaighat coarse sand : 4 graded stone aggrt. 20mm nominal size).
(c) 1 : 3 : 6 (1 cem : 3 Kanhaighat coarse sand : 6 graded stone aggrt. 40mm nominal size).
BRICK WORK
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
STONE MASONARY WORK
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 Kanhaighat coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 Kanhaighat coarse sand)
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORMWORK
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
WOOD WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a)Local best quality teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows( Area of opening for panel insers excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25mm to 40 mm thick), (a) Local best quality teak wood
Providing beams including hoisting, fixing in position and applying wood preservative for the unexposed surfaces, etc. complete with : Local best quality Uningthou wood
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special section, power pressed from MS sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm wide X 1.6 mm thick with flages of 27mm and 37 mm,at1200mm centre to centre,one flanges fixed to the ceiling with dash fastener 12.5mm dia 50mm long with 6mm dia bolts, other flanges of cleat fixed to the angle hangers of 25x25x0.55 mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I channels 45x 15x0.9 mm running at the spacing of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermadiate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, i/c fixing perimetre channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws@230mm interval i/c fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm etc.,i/c jointing and finishing to a flash finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes,finishing with jpinting compound in 3 layers covering upto 150mm on both sides of joints and two coats of primer suitable for board, allas per manufacture specification and also i/c the cost of making opening for light fittings,grills,diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawings and specification and direction of the Engineer in charge but e/c the cost of painting with (i) Fully Perforated Gypsum Plaster Board of size 1200X2400X12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer-in charge and as per manufacture specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than0.60.
P/F M.S. sheet 1mm thick as eave board welded by M.S. frame of ISA 25 X 25 X 3mm and flat bars 25 X 3 mm including painting etc. complete.
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing bright finished brass towerbolts (barrel type)with necessary screws etc. complete :.a)250 x 10 mm
Providing and fixing bright finished brass handles with screws etc.complete :. (a) 125mm
ROOFING & CEILING
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a)precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I seam bolts and nuts, G.I plain and bitumen washers complete : Ridges plain (500 - 600mm) (a) precoated galvanised iron profile sheets 0.50 mm thick.
FLOORING
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Kanhaighat coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 Kanhaighat coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
FINISHING
12mm cement plaster of mix 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster on rough side of single or half brick wall of mix1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
MISCELLANEOUS
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Kanhaighat coarse sand: 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 kanhaighat Kanhaighat coarse sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 Kanhaighat coarse sand :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 Kanhaighat coarse sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SANITARY ITEMS
Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. i)15 mm nominal outer dia Pipes
Providing and fixing Polyethelene-Aluminium- Polyethelene PE-AL PE Composite Pressure Pipes conforming to IS - 15450, U.V.stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C,including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with trenching, refilling and testing of joints complete as per direction of the engineer in charge. External work i ) 2532 (32 mm OD ) pipe
Providing and Fixing U-PVC pipes (working pressure 4 kg / cm²) Single socketed pipe 110 mm dia
Providing and Fixing S.C.I. gully or nahani grating 100 mm dia
Providing and Fixing Slotted cowl (terminal guard ) 100 mm dia
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
(Sh: Providing IEI in the Toilet Block (3 WC & 3 Bath)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F 12W LED bulb.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 24 :- Construction of Ground Sump with Staging )
EARTH WORK.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
(b)1: 3 : 6 (1 cem : 3 Kanhaighat coarse sand : 6 graded stone aggrt. 40mm nominal size).
R.C.C. WORKS.
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORK.
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
BRICK WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
STEEL WORKS
Providing & fixing M.S. grills of required pattern in frames of window etc with M.S. flats, square or round bars etc i/c priming coat with approved steel primer all complete.(a) Fixed to openings/ wooden frames with rawl plugs screws etc.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
Steel glazed windows and ventilators of standard rolled steel section joints mitred and welded with 15 x 3 mm lugs 10 cm long with steel plugs embedded in cement concrete block 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggregate 20 mm nominal size) or wooden plugs and screws of rawl plugs and screws or with fixing clips with bolts and nuts as required including providing and fixing of 4 mm thick glass panes with glazing clips complete including applying a priming coat of approved steel primer excluding cost of metal beadings and other fittings except necessary hinges or pivots as equired.(i) Ready made steel windows (side hung /top hung)
FINISHING
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.(a)water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:- new work (two or more coat applied @ 1.67 ltr/10sqm over and i/c base coat of water proofing cement paint applied @2.20 kg/10sqm.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
(SH 25 :- Construction of Waste Collection Pit )
SH : EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors i/c watering, ramming consolidating and dressing complete
SH : CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
SH : R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
(b) Columns, Pillars, Piers, Abutments, Posts and Struts
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers, with water proof ply 12mm thick
( d) Suspended floors, roofs, landings, balconies and access platform with water, proof ply 12mm thick
(e) Edges of slabs and breaks in floors and walls Under 20 cm wide
BRICKS WORKS
Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1cement :4 Kanhaighat coarse sand)
SH : FINISHING
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement on the roughside of single or half brick wall
52 mm thick cement concrete flooring with concrete hardener topping under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 Kanhaighat coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume .hardening compound is mixed @ 2 litre per 50kg of cement or as per manufacturers pecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
(Sh: Providing IEI in the waste collection pit.)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with piano type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing switch box/cover i/c connection etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
15/16 amps switch
6 pin 15/16 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 9W LED bulb
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH 26 :- Construction of Water body )
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :(a) 1:5:10 (1 cement : 5 Kanhaighat coarse sand : 10 graded stone aggregate 40 mm nominal size)
R.C.C. WORKS
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(a)1:1.5:3 (1 cement : 1.5 Kanhaighat coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. (b) Thermo-Mechanically Treated bars.
FORM WORKS
Centering and shuttering including strutting, propping etc. and removal of form for(a) Foundations, footings, bases of columns, etc. for mass concrete
FINISHING
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Kanhaighat coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Boulder filling dry hand packed tightly as in pitching and vertical bunds with sloping face.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Pony Big
Pony Small
Sangai Big
Sangai Small
Nongin Big
Nongin Small
(SH 27 :- Development works & Earth Banking )
Banking excavated earth in layers not exceeding 20 cm. in depth, breaking clods,watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m. All kinds of soil
(SH 28 :- Construction of fencing - Exibition Park )
Construction of chain link compound fencing with steel Framework(2.44 m Ht)
(SH: Installation of DG set & LT Panel Board)
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of four way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 200 amp. TPN on load changeover switch - 1 No.
2. 200 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 4 Nos.
P/L 50mm2 four core pvc ins.(heavy duty) Al. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Earthing with copper earth plate 600mmX600mmX6mm thick i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) ae reqd.
Extra for using salt and charcoal for G.I. or copper plate earth electrode as reqd.
P/F earth bus of 25mmX5mm copper strip on surface or in recessed for connection etc. as reqd.
(Sh: Providing Yard lighting (Solar)
Supply, Installation, Testing & Commissioning of solar LED street lamp All-In-One with in built SCC system wattage of 30 W of make Crompton Greaves Ltd.code no.CSADEMP25/30CDL, 140 Lumen/ Watt high efficiency crystaline solar SPV panel and G.I.Tubular/Octagonal pole of 6mt.high including connection and muffling in R.c.c. 1:3:6 ( 1 cemt:3 c/sand: 6 stone aggrt of 40 mm n/size) including centering, shutturing, earth work etc.as reqd.
Supply, Installation, Testing & Commissioning of solar LED street lamp All-In-One with in built SCC system wattage of 15 W of make Crompton Greaves Ltd.code no.CSADSPI 15 CDL, 140 Lumen/ Watt high efficiency crystaline solar SPV panel and G.I.Tubular/Octagonal pole of 6mt.high including connection and muffling in R.c.c. 1:3:6 ( 1 cemt:3 c/sand: 6 stone aggrt of 40 mm n/size) including centering, shutturing, earth work etc.as reqd.
(SH 31 :- Dismantling and Demolition of old existing structure )
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in charge. In Cement mortar
Demolishing stone rubble masonry manually/by machanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area 40 square centimetres and above
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc.complete and stacking within 50 metres lead : Of area beyond 3.00 sqm
Nongthombam Motilal Singh
M/s Seven Clan Agency
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid