Tender Value
₹44.8 L
EMD Value
₹89,600
Closing Date
2 May 2022, 6:00 pmClosed
GE BENGDUBI
Bengdubi Military Station PO-Bengdubi, Dist-Darjeeling, Pin 734424
GE/BENG/49 OF 2021-22 PROVN OF 02 X HIGH MAST LED LIGHTS 01X SOLAR TREE PLANT 08X 11 MTR HEIGHT STEEL TUBULAR POLE ALONGWITH FLOOD LIGHT SR BER DG SET AND MINOR WORKS AT CERTAIN UNITS UNDER AGE E/M OF GE BENGDUBI MIL STN
2022_MES_501878_3
GE/BENG/49 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE BENGDUBI
MES Enlisted/ Un-enlisted contractor of Class D and above with category b(i)
8 documents required · 8 mandatory
₹500
GE BENGDUBI
₹89,600
Yes
6 May 2022
20 Apr 2022
4 May 2022
20 Apr 2022
2 May 2022
26 Apr 2022
Amount
SCHEDULE 'A'
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.5 mtr deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc and getting out in soft/loose soil complete all as specified.
Ditto all as per ser item No 1.00 here-in-before but depth exceeding 1.5 Mtr and not exceeding 3 Mtr.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 70 Sqmm 3.5 core laid in trenches /poles/on wall complete including necessary cable glands, aluminium lugs duly crimped, termination etc all as specified and directed.
M&L for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 3.5 core laid in trenches /poles/on wall complete including necessary cable glands, aluminium lugs duly crimped, termination etc all as specified and directed.
Supply, laying, jointing and testing LT cable in trenches or on poles/wall, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and testing LT cable in trenches or on poles/wall, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed.
Supply & Laying Sub Class 'B' Bricks,old size, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and directed.
Supply and laying GI tube medium grade 40 mm bore with fitting for protection of cables, strips laid in trenches/wall/floor including necessary clamps, bolt, nut etc. complete all as specified and directed.
Supply, Errection, Installation, Commissioning & Testing of 20 Metre High Mast lightning System (Make: BAJAJ / PHILIPS / CROMPTON) (Material construction of high mast sheet shall be of BSEN 10025 / lS 5986 Gr Fe 510 or equivatent). Mast shall be in two sections, hot dip galvanized and suitable for wind velocity as per IS 875 Part 3, 3 point suspention system. It shall also include foundation and 12 Nos 200 watt LED flood lights luminaire including accessories. The scope of work shall also be deemed to include the following:- a) Galvanised Lantern carriage arrangement siutalbe for 12 luminaires symmetrically & Its control gear boxs and lightning finial and with 03 point suspension system. (b) LED floodlight luminaire including all accesories, silicon filled driver IP-66 protection, driver must have BIS registered of cat part No LFLN-200-CDL/60M of CROMPTON. (c) Double drum winch motor and manual method of operation tested load per drum 1000 Kgs. (d) Stainless steel wire rope 6 mm dia 7/19 construction conforming to AISI-316 grade. (e) The mast shall have an integral power tool 1.5 HP 1400 RPM single speed Reversible 415 Volt, installed inside the base compartment for its operation. (f) LED type Aviation obstruction light. (g) Service Wiring feeder to flood light with multistranded copper conductor cable with double run for one standby cable.
Sl item no. 12.00 Contd... (h) Design, costing of suitable RCC foundation with Concrete grade for high mast considering SBC of soil as 10 T/Sqm (after cutting of concret & bituminus road and incl bolts manufactured from special steel along with nuts, washers, anchor plates and templates etc. and including PCC (1:2:4) for panel grounting, complete all as per manufacturer's instractions subject to approval of the GE. (j) Supply, installing, testing and commissioning, factory made and tested, LT feeder pillar box, outdoor type (CPRI approved) .The panel shall be dust and vermin proof, IP 65 class protection and made out of 3.15mm CRCA MS sheet and 40x40x4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, double door openable type, with aprons for cable entry, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 10 Sq mm. 2 Nos danger notice plate made of 1.6 mm thick mild steel sheet, vitreous enamelled white of size 25 x 20 cm with letters, figures and conventional skull bones in signal red colour shall be fixed to the pillar box with appropriate size nuts, bolts and washers etc indicating the voltage and danger in Hindi and English complete all as specified and directed. The following items/ accessories shall also be deemed to be incuded and accomdated in the above panel:- (i) Stag type,4 way terminal(I/P) 63 Amps - 1 No (PCB 150 ACBC) (ii) MCCB, 63 Amps, 4 pole, 25KA, 415V - 1No (iii) Contactor 3pole, 63 Amps -1 No (iv) Toggle Switch 6Amps - 1 No (v) Timer (analogue) with battery backup -1 No (vi) Stag type, 4way terminal (O/P) 63A - 1 No (PCB 150 ACBC)
Sl item no. 12.00 Contd.. (vii) Over load relay 2/3.5A - 1 No (viii) F. contactor 9A - 1No (ix) R. contactor 9A - 1No (x) Motor terminal 32Amps -1 No ((xi) Push switch terminal-1No (xii) Push switch (F/R) STD - 1 No. Notes : - (aa) Work shall be executed as per standard engineering practice and as per manufacturers instructions. (ab) Before placing the order, the design/ drawing of high mast of the manufacturer shall be got approved from GE. (ac) The contractor shall get the work executed from the manufacturer or their authhorized rep. (ad) Size/type of RCC foundation Shall be carried out as per manufacturer's drawings subject to approval of GE. (ae) Unit rate inclusives of 20 mtrs. High Mast Tower suitable for 12 Luminaries, 20 mtrs. LED flood light luminaires, High Mast assecories, Mechanical Components including Head Frame & Pully Assay, Winch Bracket, Lantern Carriage Ring including control gear box Mtg arms for luminaires, Resting Bracket Guide Ring, Compensating Disc, Lightening Arrestor etc , Wire Rope , D Suckel clamps , Nuts and bolts , cable Foundation Accessories , Winch Assembly , Termination & distribution box, Power Tool, Feeder Pillar Box, Civil foundation with materials, excavation and erection, LED Aviation light (af) Any item missed out above but is technically required for safe and proper installation and operation of High Mast shall be deemed to be included in the quoted rate all as directed by the GE.
M&L for earthing complete of advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgrated (Zinic & alloy coated) Zinic coated (80-100) microns with pure (99.9%) & alloy coating (200-250) microns earthing system confirming IS-3034 the outer and inner pipe should be 76.2mm & 41.9mm dia 3 mtr length zinic coated with additional special alloy coating 300mm on the topside for additional protection of the terminal the annular space between the pipes being filledup with compact fill(CF) (Crystalline conductive compound) the compact fill (CF) mixture which is machine pressed in the pipes should not disintgrate or collapse when outer pipe corrods, the inner pipe should be extended with terminals for connectivity. The job includes digging the pits and refilling the same by electrode/conductolite back fill compound (Ground enhancer)the BFC should dbe eco friendly it should not contain environmentally hazard materials having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP earth pitcover for protection and safe guard of terminals. In area where soil condition is bad good earth is to be arranged to fill the excavated pits by mixing the same with BFC 4 bags (as per soil condition) extra perpit/unit. As earth electrode is the main component of the earthing system which is indirect contact with the ground and thus provides ameans of releasing or collecting earth leakage current. The materials should have a good electrical conductivity & anti corrosion properrty in wide range of soil condition complete and testing on completion all as specified and directed. Make ASHLOK/ True power/Ennov (Note : earth result should be obtained minimum 1 ohm)
Supply and fix GI earth strip of size 32x6 mm fixed on wall with insulators and laid in trench complete all as specified and directed.
M&L for horizontal boring under the road below 1 mtr from the road surface and dia of hole not exc 100 mm without damaging the existing road getting out and disposal of soil to a distance not exceeding 50 m from the site of work all as specified and as directed.
(A) Supply, Transportation, Installation & Commissioning of 8 KWp Solar PV Modules in 330Wp, As per latest MNRE Specifications:- (i) IEC: 61215/IS: 14286 Crystalline silicon terrestrial photovoltaic modules – Design qualification and type approval. (ii) IEC: 61730 – Part 1 Photovoltaic (PV) module safety qualification – Requirements for construction. (iii) IEC: 61730 – Part 2 Photovoltaic (PV) module safety qualification – Requirements for testing. (iv) IEC: 61701/IS: 61701 Salt Mist Corrosion Testing of the module. 5. IEC: 62804 :Test method for detection of Potential Induced Degradation of photovoltaic (PV) modules. (B) Supply, Transportation, Installation & Commissioning of 10 KVA Inverter ON Grid, conforming to all necessary requirements of WBSEDCL (Each - 01) (C) Supply, Transportation, Installation & Commissioning of Solar Hot Dip GI Mounting Structure, as per the IS Specifications Designing of Module Mounting Structure (MMS): During Structural design following points must be include but not limited to the following: (i) There must be sufficient gaps between the rows of the panels and all precautions to be taken to avoid any shading on the panels. Minimum 500mm clearance should be maintained in between roof and module. (ii) The module alignment and tilt angle shall be calculated to provide the maximum annual energy output. This shall be decided based on the location of array installation. (iii) The structure shall be designed to allow easy replacement of any module and shall be in line with site requirement.
Sl item no. 16.00 Contd.. (iv) The mounting structure shall be designed for simple mechanical and electrical installation. It shall support SPV modules at a given orientation, absorb and transfer the mechanical loads to the base properly. (v) The mounting steel structure shall be as per latest BIS 2062 (amended up to date) (vi) The array structure shall be so designed that it will occupy minimum space without sacrificing the output from SPV panels at the same time. (vii) All fasteners, nuts, bolts shall be of stainless steel of grade SS 304. (viii) The support structure & foundation shall be so designed to withstand wind load of the location as given in relevant Indian code for wind (IS 875 Part III, latest edition). (ix) IS 800-2007 shall be followed for structural design. Accordingly STAAD output of the design is to be submitted. (x) Galvanization of the structural members shall conform to IS: 4759. The quality of zinc shall conform to IS: 209 and IS: 2629. All galvanized materials shall withstand tests as per IS: 2633. Arrangement of testing shall be made by the contractor. (2.17 Ton) (D) Supply, Transportation, Installation & Commissioning of Earthing Pipe of 10Ft 50mm Dia (Each -3) (E) Supply, Transportation, Installation & Commissioning Lightening Arrestor (Each -2) (F) Supply, Transportation, Installation & Commissioning of Solar Grade Tinned DC Cable 4Sqmm (90 RM) (G) Supply, Transportation, Installation & Commissioning of AC Cable for required size for power evaluation (20 RM)
Sl item no. 16.00 Contd.. (H) Supply, Transportation, Installation & Commissioning GI Strip 25X3 for Earthing (60 Kg) (J) Supply, Transportation, Installation & Commissioning Array Junction Box (01 Set) (K) Supply, Transportation, Installation & Commissioning of ACDB (01 Set) (L) Supply, Transportation, Installation & Commissioning of BOS (MC 4 Connector, Lugs, Nut Bolts, Fastners etc) (01 Set) NOTES : The items of work mentioned in this schedule shall be executed as per following:-The above items shall be quoted and executed on ground based on performace Guarantee basis. The performance Guarantee is related to achieving the 100 KW power generations with specified efficiency and efficacies. The contractor shall also be responsible for desired operational efficacy and desired efficiency of the system during its life cycle of minium 15 Yrs. The plan layout & schematic diagram shall be got vetted from any one of the following agencies (Approved agencies) (i) National institute of Solar energy (ii) Sardar Swarn singh National Institute of renewable energy (iii) Solar energy corporation of India (iv) The Indian renewable energy development agency. The vetting agency shall also be approve the make proposed by the contractor in his plan layout & schematic diagram. (i) The successful contractor shall submit the following documents duly vetted by any one approved agency with four weeks of placements of work order for approval of Accepting Officer :-
Sl item no. 16.00 Contd.. (a) Design calculation: The tenderer should work out design based on the conditions prevalent at Bengdubi using PVSYS & PVSOL software or any other software shall be submitted for approval of Accepting Officer/Users. (b) Plan depicting layout of all equipment and Sub Systems of the PV system. This shall be self contained and self explanatory representation of layout of equipment and sub systems. The dimensioned drawing of the site of work clearly marked with all subsystems components etc shall be submitted. (c) Schematic diagram of the electrical system. This shall contain specification, size, current, voltage and fault levels rating of all cables, switch gears and instrumentation & control systems and all metering and interlocking etc. (ii) All the documents/technical details mentioned above duly vetted as specified above shall be approved by Accepting Officer. The Accepting Officer may approve the documents as submitted by the Contractor or may suggest modification (iii) Alteration in documents /technical specifications duly supported with reasons for the same. The work shall be executed based on the approved doucments. In case of any dispute the matter shall be referred to accepting officer. The decision of accepting officer shall be final and binding. (iv) The drawings and other techincal details submitted by the successful contractor, alongwith all calculations, drawing, technical write ups etc shall become departmental property. Department may use these subsequently as deemed necessary. The contractor shall have no claim on these documents and their subsequents use by the department.
Sl item no. 16.00 Contd.. (v) After completion the contractor must engage a third party MNRE aproved consultant for final testing and third party inspection of executed work. The consultant shall certify that the work has been executed in accordance with vetted and plan layout & schematic diagram, The contractor shall propose a panel of three consultant for this purpose. The final decision on the consultant to be engaged shall be taken by Accepting Officer. All cost and charges for engagement of consultant shall be born by the contractor. (vi) After execution of project the contractor will verify generation of electricity as per vetted design in the PVSYST & PVSOL report submitted. The contractor shall ensure suitable arrangements for solar PV Panels. (vii) Department will give completion of the work to the contractor only on the basis of completion report submitted by the third party consulatnt engaged by the contractor.
Supply, install, testing & commissioning of hi wall, split-type Air Conditioner Unit of capacity 3 TR based on Inverter Technology comprising of indl indoor & outdoor units complete with cordless remote control unit & with in-built air ionizer & plasma filter for better indoor air quality with minimum 5 star rated incl electric connection complete all as specified and directed. NOTE : (i) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall of Non-CFC type & as per the latest technology. (ii) The cost of additional refrigerant pipes required (if any) is deemed to be included in the unit quoted rates. (iii) Suitable piping of adequate length & size 5/8" for drainage of condensate water from indoor unit shall be provided & the cost of the same is deemed to be included in the unit quoted rates. (iv) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 volts with accuracy of (+/-) 2.5% and of capacity 5 KVA complete all as specified and directed.
Supply, install, testing & commissioning of hi wall, split-type Air Conditioner Unit of capacity 2 TR based on Inverter Technology comprising of indl indoor & outdoor units complete with cordless remote control unit & with in-built air ionizer & plasma filter for better indoor air quality with minimum 5 star rated incl electric connection complete all as specified and directed. NOTE : (i) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall of Non-CFC type & as per the latest technology. (ii) The cost of additional refrigerant pipes required (if any) is deemed to be included in the unit quoted rates. (iii) Suitable piping of adequate length & size 5/8" for drainage of condensate water from indoor unit shall be provided & the cost of the same is deemed to be included in the unit quoted rates. (iv) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 volts with accuracy of (+/-) 2.5% and of capacity 4 KVA complete all as specified and directed.
Supply and fixing of single pole and neutral enclosure with a three pin and earth plug and socket complete with SPN MCB of 63 amps all as directed and specified.
Supplied and fixed single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 amps. complete all as specified and directed.
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through 25mm dia PVC Conduit complete all as specified and directed. Note :- (a) PVC Conduit shall be included in same rate. (b) For concealed sub-main wiring cutting chases with making good surface in existing shall be included in quoted rate. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through 32mm dia PVC Conduit complete all as specified and directed. Note :- (a) PVC Conduit shall be included in same rate. (b) For concealed sub-main wiring cutting chases with making good surface in existing shall be included in quoted rate. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
Supply and fixing sheet metal enclosre for MCBs, DBs, phosphatised, powder coated, tripple pole and neutral (TPN) 415 volts, double door, suitable for 4 way with dim rail earth and neutral bar all as specified and as directed. Make - Legrand /Havells/ C&S or equivalent complete all as specified and directed.
Supply and fixing in proper position MCB TPN 63 amps capacity, 415 volts with 10 KA breaking capacity all as specified and as directed.
S&F MCB single pole and neutral 240 volts 32 to 63 amps capacity complete all as specified and directed.
M&L for 3 core cable 1.5 sqmm of FRLSH PVC insulated copper conductor weather proof in existing surface/ recessed/on pole with PVC conduit pipe, clamps as required complete all as specified and directed. (Make : Finolex/Polycab/Plaza)
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver, lamp & SPD etc. complete all as directed.
M&L for steeltubular swaged polescompleteeith cast iron base plate finial taper plug boltsnuts & scres as specified type 410 SP-55(11 mtr long) all asspecified and directed
S&F thermoplastic body loopin loopout enclosure of size 205mm x 255mm x 112mm consisting of 4 Nos terminal fixed on porceline support inside enclosure fixing of enclosure including S & F MCB SP 6 Amps and with pole using 40 x 6mm size MS FI clamps of required shape with bolts, nuts & washers complete all as specified and directed
Supply and fixing GI bracket for flood light made out of angle iron 50x50x5mm grade 1.5 mtr length complete with MS flat iron clamp,nuts,bolts etc as required at site all as directed and specified.
BLANK
M&L for P.C.C. 1:3:6,Type C-2 using 40mm graded stone aggregate as in filling or for mass concrete of poles, stays, struts or any other indicated work including form work(if required) complete all as specified and directed.
M&L for P.C.C. 1:2:4, Type B-1 using 20mm graded stone aggregate for coping of poles / platform of feeder pillar box or any other indicated work including form work(if required) duly 20mm thick cement plaster (1:4) and making the surface smooth and even by using extra cement complete all as specified and directed.
Supply, commissioning, erecting and testing complete of manufacturer or OEM manufactured, static silent with eccoustic enclosure Diesel Engine Driven Generating Set of capacity 40 KVA Liquied coolant cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Bengdubi mil stn including PCC foundation (of suitable size leaving at least 0.5 m all around for ease of movement and 0.5 M height), anti-vibration pads complete all as specified and directed, including all features to comply with latest CPCB guidelines and comprising of followings:- (i) ENGINE (Prime Mover): Diesel Engine 1500 RPM, direct injection, multi cylinders, four stroke, confirming to IS:10000/ISO3046/BS:649/BS:5514 amended up to date, for continuous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 40 KVA or next higher capacity at outdoor atmospheric conditions at Bengdubi, fitted with following accessories:- (a) Dynamically balanced fly wheel with starter ring (b) Air cleaned oil bath type. (c) Electronic governer (d) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noice level. (e) Radiator Assembly.
Sl item no. 36.00 Contd... (f) Radiator fan with guard. (g) Vaccum indicator. (h) Fuel filter and fuel hoses. (j) Fuel injection pump (FIP) (k) Lubricating oil filter and pump. (l) Electrical starting system with battery charging alternator and axial type starter motor including adquate number of high capacity maintenance free lead acid battery, 12 Volts DC as per manufacturer recommendation including interconnecting cable/ leads with terminal complete with start/ stop switch. (m) Engine safety shut down system against low oil pressure and high water pressure. (n) Exhaust gas driven turbo charger. (o) Oil filter. (p) Lube oil cooler. (q) Engine maintenance manual with spare parts list. (r) Suitably designed acoustic enclosure as per CPCB regulation. (s) Any other item not included/ specified but is a standard design of the manufacturer. (ii) ENGINE INSTRUMENT ELECTRONIC PANEL:- Engine instrument panel shall compriding of the following control : (a) Starting on/ off switch. (b) Water tempreture display. (c) Hour meter cum RPM display.
Sl item no. 36.00 Contd... (d) Lub oil pressure display. (e) Lub oil tempreture display. (f) Battery charging display. (g) Safety alarm against high water tempreture and low oil pressure. (h) Automatic on/off of engine facility with GCU. (j) Any other item not included/ specified but is a standard design of the manufacturer. (iii) ALTERNATOR:- Alternator shall be self excited, self regulated, brushless for 40 KVA continuous operation at the speed of 1500 RPM at 415 Volts, 50 Hz, Three Phase, 4 Wire system with advance electronic voltage regulator to ensure high voltage accuracy with + / -1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming to IS-4722 complete-01 No Note:- Alternator should be able to deliver output rating at actual site conditions. (iv) Common fabricated base frame for engine and alternator made from structural channel, leak proof PCC 1:2:4 mix, type B1 foundation including adequate number of suitable anti vibration pad all as per the recommendation of the manufacturer-01 Number
Sl item no. 36.00 Contd... (v) Bottom mounted (or as per manufacturer design) steel fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 Hour continous operation inside canopy with fuel level gauge, drain plug, locking arrangement etc with and including GI pipe connection duly laid as per Engineering practice complete. (vi) AMF CONTROL PANEL: Supply, fabricating and testing of factory made, 3.15 mm thickness outdoor type, floor mounted cubical automatic main failure panel with degree of protection IP-42 confirming to IS 2147, suitable for 40 KVA capacity DG set, fabricated using 14 Gauge CRCA sheet, powder coated comprsing of suitable rated bus bar, internal wiring with control MCB, provn of connecting incomming and outgoing leads/ bus bar as approved with and including following accessories:- (a) Master switch for auto/ manual/ reset/off- 01 No (b) Ammeter digital type, 96x96 mm with CT's- 03 Nos aux supply 230 Volts, AC, accuracy Class 1. (c) Voltmeter digital type 96x96 mm to read 0-500 Volts aux supply 230 Volts, accuracy Class 1.0 (d) Digital frequency meter -01 No aux supply 230 Volts, AC and digital energy meter Aux supply 230 Volt AC, 3 Phase, 4 Wire (e) Push buttton start, stop, reset-01 No (f) Set of lamp for indicating load on set, low pressure, high cylinder tempreture, load on mains, set fails to start, low oil pressure. (g) Battery charger connected to load.
Sl item no. 36.00 Contd... (vii) The contractor's quoted rates shall also be deemed to include to carry out comprehensive maintenance, periodic maintenance, servicing, preventive maintenance, arranging inspection and visit of OEM Rep (alongwith their trademen) including rectification of the defects, replacement of the defective parts, components, materials and carry out all the services as required (material & labour cost included for all such elements) to keep the D.G set perfectly in servicable & functional condition during the defects liability period of 2 years from the date of completion, all as per the manufacturer's recommendations, as specified and as directed by the GE. To meet the anticipated liability of the servicing, maintenance, defects rectification, etc during defect liability period of 2 years, an amount of Rs 40000.00 (Rupees forty thousand only) shall be retained from the RAR/Final Bill (as applicable) on account of the comprehensive maintenance, inspection, visit of rep of OEM (alongwith their trademen), periodic maintenance, rectification of the defects & other services as specified. The RAR/Final Bill (as applicable) may be processed by the GE after retaining the above amount of Rs 40000.00 (Rupees forty thousand only) . It is further clarified that the amount of Rs 40000.00 (Rupees forty thousand only) is over and above the amount to be retained from the RAR as per the relevant condition of IAFW-2249 and Performance Guarantee to be deposited by the contractor after acceptance of the tender. The contractor however if desires may deposit FDR of Rs. 40000.00 in favour of GE. The retained amount/FDR of Rs. 40000.00 (as applicable) and Performance Guarantee Amount shall be released to the contractor only after satisfactory expiry of the defects liability period of 2 years. (viii) The DG set shall be got inspected and tested in the factory by the rep nominated by the Accepting Officer before delivery from the factory. The records of the inspection shall be signed by the rep of Accepting Officer, contractor and rep of Manufacturer/OEM. (ix) The Generator set shall also be tested in the presence of IEM on variable load continuously for 12 hrs including 1 hour in overload individually as per IS and as specified. The Generator set will also be tested as per OEM recommendation. Technical representative of manufacture / OEM will also be present during testing of DG set to be carried out by IEM. The records of the testing shall be signed by IEM, GE, Engr-in-Charge and cantractor.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts Out-door type Feeder pillar box 'Pedastal type' Confirming to IP 43 & IP 65, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours. Bus bar shell be properly supported/mounted on epoxy insulators. All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips. Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete. Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply. INCOMING:- (a) MCCB 4 pole, 415 Volts, 400 Amps, 25 KA, 100% Icu- 01 No. (Make: Legrand/L&T/ABB).
M/S UTTAM ENTERPRISES
SHRI S K BHATTACHARJEE
UNIVERSAL CONSTRUCTION
MUKHERJEE ENTERPRISE
PRADIP KUMAR BOSE
Shree Ram Construction
M/S CONTRACTS
GURUNG CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .