Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.7 LAccepted-AOC | ₹68.7 L | L1 | Accepted-AOC PROPER |
| 2 | L2₹71.4 L+₹2.7 L (3.91%)Rejected-AOC | ₹71.4 L+₹2.7 L (3.91%) | L2 | Rejected-AOC NOT QUALIFIED FOR AOC |
| 3 | L3₹72.1 L+₹3.4 L (4.92%)Rejected-AOC GOROKHIA DOLE JORHAT ROAD CITY TOWN JORHAT P O GOROKHIA DOLE P S JORHAT DISTRIST JORHAT PIN 785001 | JORHAT | ASSAM | 785001 | ₹72.1 L+₹3.4 L (4.92%) | L3 | Rejected-AOC NOT QUALIFIED FOR AOC |
Tender Value
₹73.5 L
EMD Value
₹1.5 L
Closing Date
22 Apr 2020, 2:00 pmClosed
Addl. Chief Engineer, UAZ, W.R. Deptt., Dibrugarh
O/o the Addl. Chief Engineer, UAZ, W.R. Deptt., Dibrugarh
Construction of road cum drain near Water Resources Department at Dibrugarh Town under CIDF.
2020_DoWR_17210_1
DIB/CIDF/DRAIN/2019-20/1
Open Tender
Civil Works
Works
60 days
Dibrugarh
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
The Executive Engineer, Dibrugarh W. R. Division
₹1.5 L
Yes
Dibrugarh
18 May 2020
17 Mar 2020
23 Apr 2020
17 Mar 2020
22 Apr 2020
21 Mar 2020
20 Mar 2020
Amount
Earth work in excavation in slushy/ marshy soil, decomposed organic matter mixed with brickbats, broken glass panes, broken earthen pots etc. removal of stumps and other deleterious matter in the proposed building site including constant water pumping for bailing out water as directed including return filling and ramming after completion of work with good quality earth (measurement will be on the basis of profile or section measurement).
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Up to a depth of 2.00m below the existing ground level.(a) In ordinary soil
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).(a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (a) Using 38mm thick plank
Vertical surface such as walls (any thickness), parapet walls, partitions, walls of septic tank, inspection pit and the like including attached pilasters, butresses, plinth and string courses and the like. (i) Using 38mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness. (i) Using 38mm thick plank
Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (i) Using 38mm thick plank
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Dismantling steel work in built up sections in joists, angles, channels, tees, flats etc. including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking the materials as directed by the Department for all levels
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels.
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (i) 0.40 mm thick
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. a) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4.
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed. a) M. S. Angles.
Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed. b) M. S. Flats.
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed. (Door hinges to be paid as per relevant item of the schedule of rates).
Providing, fitting, fixing 20 mmx 50 mm mesh expanded metal wall of 18 gauge (1.2 mm thickness) in sal wood dressed frame not more than 1.20 m centre to centre including sal wood beading of 50 mm x 25 mm size sides chamfered , fitted with necessary wood screws spaced not more than 400 mm apart etc. complete as directed (sal wood frame to be measured and paid separately).
Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Extra over item no.13.5.2 above for every subsequent coat of acrylic emulsion exterior coatings of Unicem 'Rakshak' brand of required shade.
Pinku Moni Bhuyan
M/S TINI VAI SUPPLY AND CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .