Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹46.4 L+₹1.7 L (3.77%)Rejected-AOC RANGAPAHAR CROSSING RAILWAY GATE NO 1 DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-AOC Bid value/rates are reasonable | |
| 3 | L3₹46.9 L+₹2.2 L (4.88%)Rejected-AOC HOUSE NO 99 3RD FLOOR SK JAIN BUILDING KALIBARI ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L3 | Rejected-AOC Bid value/rates are reasonable | |
| 4 | L4₹48.4 L+₹3.7 L (8.24%)Rejected-AOC BR GADGIL ROAD PUNE MAHARASHTRA 411030 INDIA | PUNE | MAHARASHTRA | 411030 | L4 | Rejected-AOC Bid value/rates are reasonable | |
| 5 | L5₹49.2 L+₹4.5 L (10.1%)Rejected-AOC HOUSE NO 59 THILIXU VILLAGE BLOCK V PS POST DIMAPUR NAGALAND 797 112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L5 | Rejected-AOC Bid value/rates are reasonable |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
29 Dec 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
SPL REPAIR TO ARMY AVN CIVIL WORKS OF 12 (I) R AND O FLT PROVN OF PARKING SHED AND RAMP FOR MAINT OF VEH 11 TAC (AF) PROVN OF 01 X 10 OR LIVING FOR ENGR REGT IN C ZONE AND ADDN ALTN TO TOILET IN GLASS HOUSE COMPLEX AT RMS
2021_MES_487536_2
8403/C/E8
Open Tender
Civil Works
Item Rate
180 days
RANGAPAHAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GE 868 EWS
₹88,000
Yes
26 Jan 2022
16 Dec 2021
30 Dec 2021
16 Dec 2021
29 Dec 2021
22 Dec 2021
60 days
Amount
B/R WORKS Dismantling plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and as directed.
Demoiliton of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for clolumn, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for TMT bar 6 mm to 8 mm dia cut to length, bent to shape reqd incl cranking bending spiray for hooking for colums, hooking ends and binding with and incl mild steels using wire (annealed) not less then 0.9mm dia complete all as specified and as directed.
M&L for RCC 1:1.5:3 type A1 using (20mm aggregate) in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
Material and labour for brickwork with old size sub class 'B' bricks straigth or curved on plan no exceeding 6m mean radius as in wallls in cement mortar 1:6 complete all as specified and directed
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Dismantling of existing corrugated rails channels & doors and and re-errection of door in existing position incl demolition of concrete , removal of corroded hold fast and welding new MS flat 40x6 mm , 90 cm long fix in position with concrete 1:2:4 type B-1 with using 20 mm graded stone agg incl necessary form work reqd up to door height of 10 mtr all as directed by Engr-in-charge. Note: Tools & plants reqd for removing of door & fixing in existing position is included in item.
Removal of existing wheel iron bottom of hanger doors including replacing of bearings if necessary and refixing the same in the door all as directed by the Engr-in-charge incl cutting/welding greasing oiling etc complete all as specified up to height of 10 mtr complete all as specified and as directed.
S&F MS rolled section such as channels angles flat iron fixed with bolt or nut or welded conformed to FE-410-W (gde E-250) quality B complete all as directed by the Engr-in-charge.
All as per item No 10.00 but erection and fixing only and one coat of synthetic enamel paint over steel surfaces complete all as specified.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
S & F Pre-painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
M&L for 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof wall etc in repairs complete all as specified and as directed.
Dismantling expanded metal any thickness or mesh fixed with steel or aluminium frame work if any weight n exc 4 Kg per Sqm complete all as specified.
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer board E-Board Classic to be fixed aluminium grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mm duly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified.
S&F for mild steel wire netting of steel wire 1.40 mm dia and mesh size 20 mm fixed with aluminium snap grid as a bird proofong complete all as specified.
M&L preparation old plastered surfaces of wall and applying two coats of oil bound distemper on walls including complete removal of existing treatment all as specified & directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper of approved shade/tint over a coat of primer on walls all as specified & directed by Engineer-in-Charge
M&L for preparation of new plastered walls including cornices, pilasters etc and applying Two Coats of cement base paint complete all as specified and as directed.
M&L for three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed.
M&L for one coat of synthetic enamel painting to wood and wood based surfaces of any description not otherwise described over 10 cm width or girth including prepration of surfaces complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint in any tint over a coat of primer all asspecified and directed
M&L for preparation of new wooden fillets surfaces and wood based surfaces of any description not exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pint wood primer in tint as directed.
M & L for rendering in 15 mm thick in cement mortar 1:4 on fair faces of brick work (external surfaces) or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work (internal surface) or concrete surfaces of walls finished fair and even without using extra cement complete all as specified and directed.
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even and smooth without using extra cement complete all specified and as directed.
M&L for preparation of old painted steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all specified and as directed.
Dismantling framed trusses n.exc 10 m and including all members are required to be taken as under by cutting rivets complete all specified and as directed.
Surface dressing n exc. 15 cm deep complete all as specified and directed.
Surface excavation n.exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all specified and as directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth and getting out soft/loose soil complete all specified and as directed.
Excavation in trenches not exc. 1.5m wide and exc. 1.5m but not exc.3.0m in depth for foundation etc or for shaft, wells, casspits, manholes, pier holes, etc not exc 10 Sqm on plan and exc 1.5m but not exc 3.00m in depth and getting out in soft/loose soil all as specified.
Excavation over areas not exc.1.5 m wide and not exc.1.5 m in depth and getting out in soft/loose soil all as specified.
Excavation in post holes (or similar holes) each n.exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all specified and as directed.
M&L PCC 1:4:8 type D2 (40mm graded stone aggregate) in foundations, filling and mass concrete complete all specified and as directed.
M &L Hard core of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick broken stone, watered and rammed to a true surface complete all as specified and directed.
M&L 40 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) as damp proof course to horizontal or vertical surfaces including necessary form works, applying evenly a coat of blown type bitumen at 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm including 150 micron thick polythene film laid over a coat of bitumen primer @ 0.30 to 0.50 kg per sqm complete all specified and as directed.
M&L for RCC (nominal mix) Type B1, 1:2:4 (using 20mm gradede stone aggreagate) as in foundation including rafts footing, foundation beams, plinth beams, bases for columns etc basement slabs under -reamed piles etc all as specified and directed by Engr-in-charge.
M&L for RCC 1:2:4 type B1 (20 mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all specified and as directed.
M&L for Form work to the sides and soffits of floor beams haunching lintels cantilever shelves under chajjas including support overhang etc also splayes between floors and beams etc complete all as specified and directed.
M&L for formwork to the sides of square, rectangular or polygonal pillars, posts, columns, struts and piers for rough finished surface of concrete complete all as specified.
M&L Formwork to sides of concrete in foundation ,footing ,bases for columns ,rafts and raft beams ,sides and soffits or foundation and plinth beams and similar work complete all as specified and directed.
M&L for formwork to the sides of RCC/PCC bands in walls horizontal or sloping and similar work for rough finished surface of concrete complete all as specified.
M&L for providing cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and othe similar bands, plinth courses, bed plates, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork all as directed by Engineer-in-charge.
Supply only integral water proofing compound ( ISI marked ) complete all specified and as directed.
M&L 100 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) for floor sub base complete all specified and as directed.
M&L 75mm thick PCC 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base of floor complete all specified and as directed.
M & L for 100 mm thick PCC 1:3:6 type C-2, (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L 40 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded aggregate) as in floor complete all specified and as directed.
M&L Polythene film, 150 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m on roof surfaces complete all specified and as directed.
Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compount for 100mm thick slab, Grade 'B' complete all specified and as directed.
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distances pieces, cleat etc complete all as specified and directed.
Supply and fixing MS plate as in gusset plate incl necessary cutting and welding complete all specified and as directed.
Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long - 11 to 15 mm Diameter of neck complete all as specified and and directed.
Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and n exc 10cm long - 11 to 15 mm Diameter of neck complete all as specified and and directed.
M&L 75mm thick cement concrete type C-2, 1:3:6 (40mm graded stone agg )as in plinth protection finishing the cement concrete surface even and smooth without using extra cement complete all specified and as directed.
M&L for 75mm thick PCC in 1:3:6 type C1 (using 20mm graded agg ) as in path finished the surface even and smooth without using extra cement.
M&L PCC 1:3:6 type C-2 (using 40mm stone aggregate) as in channel/drain complete all as specified and directed.
Extra for forming fair finished drain or channels 30cm inner girth in cement concrete using extra cement including forms,mitred stopped ends etc complete all specified and as directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed.
Supply and fix 20mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid in floors complete all as specified and as direcetd.
All as per item no. 66.00 but 15mm bore.
Supply and fixing 20mm bore Gun metal gate valve with iron wheel head and gun metal spindle screwed both ends after and including taking up or down old unserviceable valve complete all as specified and as directed. Make : Leader/Audco/Zoloto or equivalent as approved by GE
Material and labour for glazed ceramic coloured tiles of size 300x200x7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in white cement with pigment to match with the shade of tiles laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and as directed.
S&F non-skid coloured ceremic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in neat cement slurry and pointed in white or coloured cement to match the existing surfaces laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 for fixing of tiles complete all as specified and directed.
M&L for non skid coloured joint free tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed 15mm thick in CM 1:6 all as directed .
All as per item No 71.00 hereinbefore but in skirting laid over including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
M&L for anti fungal chequered cement concrete tiles 250x250x20mm laid over and including 15mm thick screed bed in CM 1:6, etc, set, jointed and pointed in neat cement slurry with grey cement and pigments complete all as specified and directed.
Supply and fixing as in replacement steel ventilator with top hung shutters including hinges, steel peg stay complete all as specified and as directed. Note: Sheet glass shall be measured and paid seperately.
Supply and fixing 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n.exe 0.50 Sqm in each pane after and including hacking out broken glass from wooden/metal surfaces complete all as specified and as directed by the Engr-in-Charge. Make : Modifloat/Ashai/Saint Gobain or equivalent as approved by GE
M&L for RCC (nominal mix) Type B1, 1:2:4 (using 20 mm graded stone aggreagate) in columns pillars ,piers posts and struts etc complete all as specified and directed.
M&L for RCC (nominal mix) Type B1, 1:2:4 (using 20mm gradede stone aggreagate) as in lintel /band supported on walls ,beams and columns in floors roofs , landing ,balconies canopies ,deck slabs and in shelves and the like complete all as specified and directed.
S&F for framed brackets of angles or Tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary, gusset plates, riveting etc n.exc 10 kg each brackets, conforming Fe- 290. Gde -E-165 (brackets over 10 kg each to be measured under structural steel complete all as specified and directed.
M & L Shingle filling in floors, or pavings, laid in layers n exc. 15 cm thick spread levelled and blinded with earth and rammed including watering complete all as specified and directed.
M&L for preparation surfaces of steel and iron work of any description over 10 cmwidth or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of redoxide on new surfaces in any tint complete all as specified.
S & F 165 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified.
S & F 35 mm thick flush shutters , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M & L for plain fillets, square, rectangular or triangular in section clean sawn, secured with nails 2nd class hard wood exc 13 and n.exc 25 sqcm complete all as specified and directed.
S &F for 2nd class hardwood 30mm thick glazed and skeleton shutters open rebated and prepared to receive glass gauze etc divided into squares, with plain, chamfered or rounded mitred and rebated sash bars any number edges of framing plain, chamfered or rounded, fitted with cut and metered beads for securing glass etc size of members of shutters as specified in SSR Part I Sec 8 clause 8.24 (a) complete all as specified and directed.
S&F steel windows with side hung shutters including Box type hinges with steel handle and steel peg stay, complete with glazing bars, devetailed or welded complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F for galvanised mild steel wire cloth,0.56mm nominal dia of wire and average width of aperture1.18mm and fixed with tinnedtracks, or galvanised wire staples complete all as specified and directed.
S& F 4mm Pain mild steel wire, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes etc to wood, concrete or steel posts including securing with and provision of galvanised iron staples or steel pins, etc as directed
S&F Harrison rails mild steel chromium plated with fixing brackets, stops,rollers etc complete all as specified and directed.
S&F 300mm Ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 100mm size butt hinges, medium weight cold rolled mild steel and fixed complete all as specified and directed.
S&F for 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F for 150 mm Aluminium handles, cast type, anodised complete all as specified and directed.
S&F for 300 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
M & L cement concerte in surface channels and drains type C-2 1:3:6 using 20mm graded aggregate complete all as specified and directed.
M&L for loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified.
M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified.
M&L for RCC M-25 (Nominal Mix) in foundation, coloumn footing, including rafts, foundation beams and plinth beam complete all as specified
M&L for RCC M-25 (Nominal Mix) in column, piers, pillars, posts and struts complete all as specified.
M&L for RCC M-25 (Nominal Mix) in beams complete all as specified.
M&L for RCC M-25 (Nominal Mix) in slab supported on walls, beams and columns in floors complete all as specified.
M&L for precast cement concrete 1:2:4, Type B1 as in landings, cover slab ( for manholes etc.) water through mangers shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified.
Material and labour for brickwork with sub class 'B' bricks in one brick tick honey comb walling, built in cement mortar 1:3 complete all as specified.
S&F PVC vent pipe 75mm dia complete all as specified.
S&F PVC vent cowl 75mm dia complete all as specified.
S & F 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
M&L Cement concrete 1:3:6 type C-2 for bed concrete to drain pipes including packing under and haunching against the sides of pipes of 150mm dia after they are laid and tested complete all as specified.
M&L SGSW drain pipe of 150mm dia laid in trenches and jointed as specified.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S square tube, suppling and fixing in opening as per specification and drawing.
S&F factory made solid panel PVC door shutter 30mm thick (style).consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with eat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement suppling & fixing in the frame at site as per specification and drawing.
S&F for 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed.
S&F CP angle cock 15mm cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions.
S&F Vitreous China wash basin white flat back size 550x400mm excluding taps chain and plug and procelain stopper but including brackets including PVC waste pipe 32 mm
S&F vitreous China wash down (EWC) water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)complete.
S& F swivel shower of CP any colour for fixing with 15 mm pipe incl shower arms 15 mm size, 195mm long with bend of 45 degree with flange of CP any colour (min weight 40 gms)
Supply and fixing of soap-dish chromium plated all as specified
S&F grating doom 125mm dia with waste hole of PTMT (Min wt 40 gms).
S&F 600mm long tubular tower rail brass chromium plated 20mm dia, D type 60cm longfixedwith two plugs (Gutties) of 2nd class hard woodembeded in cement mortor 1:3 with MS screwscomplete all as specified.
S&F towel Ring of PTMT fixed with and including Chromium plated Brass Screws and wooden/ plastic cleats ( Minimum weight 90 gms) etc fixed in kitchen.
S& F PVC mounted 5mm thick bevelled edge looking mirror 550 x 400mm including taking down old fixed
S&F PVC Shelves of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105 gms)
S&F rotational moulded polyethylene 500 Ltrs Capacity water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float and fly nut complete screwed down for iron pipe of 20 mm dia all as specified and directed.
S&F for CP health faucet with stand 1.5mtr flexible lead including two way brass CP angle stop cock 15mm dia complete all as specified and directed. (Make :Prayag or equivelent or equivalent as approved by GE
S&F CP wall mixer (3 in 1) complete all as specified and direcated. (Make- Jaquar/Marc/Sona or equivalent as approved by GE
S&F CP Central hole basin mixer fancy type 15mm dia all as specified and directed. (Make- Jaquar/Marc/Sona or equivalent as approved by GE
Supply pnly 32 mm waste coupling of PTMT (half or full threaded)
S&F PVC connections 15mm size with PTMT nuts of length 450mm
Supply only flush pipe of polyethylene of low or high density of PVC 32mm dia for low level cistern.
S&F PVC 10 ltrs valveless syphonic action type flushing cistern low level, white, with inlet ball valve float and handle including brackets.
S&F 100mm cast iron sanitary connections socket to fit WC out let.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floor
S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/floor
S&F of 110mm dia PVC (SWR) bends
S&F 75mm PVC(SWR) bends any radius with adess door.
S&F in repairs for 75mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 complete all as specified and directed.
S&F bands, straps or stays , plain angle cleat or flat iron cleat or securing purlins to wood trusses or rafters, knee piece and similar small articles etc conforming to Fe-290 Gde E-165.
E/M WORKS Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/ buzzer, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good to the disturbed surfaces of walls, ceiling, floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and as directed.
M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connecting to earth dolly, including PVC rectangular box for mounting switches/sockets/regulators etc. with 3mm thick plastic laminated sheet cover of suitable size as required at site complete all as specified and as directed. Make: Finolex/RR Kabel/Richa. Make of caping/casing & PVC boxes: Prestoplast/finolex/Supreme.
One light/fan point controlled by one, one way switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on the independent board.
All as per item No 140.00 here-in-before but with 2.5 Sqmm for 3 pin 15 Amps switch socket point on independent board along with one run of 2.5 Sqmm copper conductor green in colour as earth continuity conductor connected to earth dolly complete all as specified and as directed.
M&L for Switch Piano, flush type single pole, one way 5 Amps complete all as specified and directed. Make:-Anchor/Legrand/Kinjal or equivalent as approved by GE
M&L for Socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed. Make:-Anchor/Legrand/Kinjal or equivalent as approved by GE
Repair/Peplacement for Switch Socket combination 2 in 1, 5 pin 5A flush complete all as specified and directed. Make:-Anchor/Legrand/Kinjal or equivalent as approved by GE
Repair/Peplacement for Switch Socket combination 2 in 1, 5 pin 16A flush complete all as specified and directed. Make:-Anchor/Legrand/Kinjal or equivalent as approved by GE
M&L for Switch Socket combination 2 in 1, 3 pin 5A/16A, 5 in 1 flush complete all as specified and directed. Make:-Anchor/Legrand/Kinjal or equivalent as approved by GE
M&L for stepped type electronic fan regulator 80 watt socket size flush type on the existing phenolic laminatied sheet etc. Make:-Anchor/Legrand/Kinjal or equivalent as approved by GE
M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and directed. Make:-Anchor/Legrand/Kinjal or equivalent as approved by GE
M&L for 20W LED, 4', Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and as directed. Make : Havells Cat No LHFYBYPNIA1W022 Regal (batten) & LHDLEFXD5LR020(LED Tube) or equivalent in Bajaj/Philips
M&L for 20W LED 4"tube with Single side connection for LED Tube Rod suitablle for fixing in tubelight batten complete all as specified and directed Make : Havells/Bajaj/Philips or equivalent as approved by GE
M&L for 10w LED 2' Wall mounted polycaronate batten internally pre-wired with electric driver and polycarbonate diffuser and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sqmm 3 core from ceiling rose to the light fitting complete all as specified and as directed.
M&L for Lamp holder , PVC/ Polycarbonate type with PVC round/square block incl 9 watt LED lamp suitable for lamp holder fittings. Make:-Anchor/Legrand/Kinjal or equivalent as approved by GE Make of Lamp :- Bajaj/Philips/Wipro or equivalent as approved by GE
M&L for LED 1x20W building Security light fitting, drawn through including GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling holes as required and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and directed. Make:- Bajaj/Philips/Wipro/Syska Led or equivalent as approved by GE
M&L for LED flood light 150 Watt capacity with high luminious efficiency made up of Epoxy powder coated pressure die cast aluminium housing with elegantly designed heat sink for efficient thermal management, sturdiness and excellent corrosion resistant and lens embedded PC cover having Top Opening seperate driver compartment with IP 66 protection and High quality toughened glass IK07 with 10 KV Built in surge protection device and all connected accessories housing, nuts and bolts etc and making electrical connection complete all as specified and directed. Make : Havells Cat No or equivalent as approved by GE SAUCERPLUSHBP150WLED85790DTOLTG/Bajaj/CG
M&L for 06 watt Edgepro Round LED panel, Slim-Fit recess mounte ceiling light round fitting extruded for efficient heat dissipation & integral non replaceable driver ultra slim body suitable for high ceiling height electronic drive etc with all accessories internally pre wired Make :Havells/Bajaj/CG/Philips or equivalent as approved by GE
S&F for Ceiling fan 1200 mm sweep, 5 star rating including suitable size of fan hook and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed. Make : Crompton Greaves/Bajaj/Orient or equivalent as approved by GE
M&L for MCB Distribution board double door type TPN 4 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. Make : Legrand/ABB/Siemens or equivalent as approved by GE
Disconnect and remove unserviceable main PCB/ display PCB and Supply and fix new main PCB/ dispaly PCB suitable for existing model of following cooling appliances complete all as specified and as directed by the Engineer-in-Charge. Make- Blue star, Godrej , Voltas or equivalent as approved by GE
Window AC 1.5 TR
Split AC 2 TR (Display PCB )
Split AC 1.5 TR (Display PCB )
Disconnect and remove unserviceable starting capacitor and supply and fix new starting capacitor suitable for existing model of following cooling appliances complete all as specified and directed by the Engineer -in- Charge. Make:Bluestar, voltas, Godrej,
1/1.5 TR window type 40 MFD 440V P2/S2 type
2.0 TR window type/ split type Air Conditioner, mfd (60+2)
Disconnect and remove unserviceable running capacitor and supply and fix new running capacitor suitable for existing model of following cooling appliances complete all as specified and directed by Engineer -in Charge. Make:Bluestar, voltas, godrej or equivalent as approved by GE
1/1.5 TR widow type/split type Air Conditioner
2.0 TR widow type/split type Air Conditioner
Disconnect and remove unserviceable capacitor of fan motor of any description and supply and fix fan capacitor of capacity 4.0 mfd / 6.0 mfd suitable for existing window type/ outdoor unit of split type air conditioner of capacity upto 2.0 TR complete all as specified and as directed by Engineer-in-Charge. Make:Bluestar, Godrej, Voltas
Taking out the burnt fan motor from the following cooling appliances and supply and fix new fan motor suitable for existing model complete all as specified and directed by Engineer-in-Charge.
Split Air Conditioner of Capacity upto 1.5/2.0 TR.
Taking down unserviceable blowermotor of split type air conditioner and supply and fix new blowermotor suitable for existing model of indoor unit of split type air conditioner of capacity upto 2.0 TR including necessary connections and testing on completion complete all as specified and as directed by Engineer - in- Charge.
Taking down unserviceable Swing motor of split type air conditioner and supply and fix new Swing motor suitable for existing model of indoor unit of split type air conditioner of capacity upto 2.0 TR including necessary connections and testing on completion complete all as specified and as directed by Engineer - in- Charge.
Disconnect and remove unserviceable compressor and supply and fix new sealed rotary / reciprocating compressor including brazing the suction / discharge lines suitable for existing model of following cooling appliances, filling the gas and testing on all as specified and directed by Engineer-in-Charge. Make : Bluestar/ Godrej/Voltas/Carrier/Hitachi.
1/1.5 TR window type/split type Air Conditioner.
2.0 TR window type/split type Air Conditioner
Material & labour for filling up & charging of R-22 refrigerant to the cooling appliances all as specified and directed by Engineer-in-Charge.
M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder coated, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. Make:- Legrand Cat No 507611 or equivalent in ABB/Siemens or equivalent as approved by GE
M&L for MCB Distribution board double door type SPN 4 way, sheet steel, powder coated, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. Make:- Legrand Cat No 507610 or equivalent in ABB/Siemens or equivalent as approved by GE
All as per item No 169.00 MCB DB SPN 2 way complete all as specified and as directed. Make:- Legrand/ABB/Siemens or equivalent as approved by GE
M&L for MCB TPN 63 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed. Make : Legrand/ABB/Siemens or equivalent as approved by GE
M&L for MCB SPN, 40 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed. Make: Legrand Cat No 408636 or equivalent in ABB/Siemens or equivalent as approved by GE
M&L for MCB SP, 5 to 32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed. Make:- Legrand Cat No 408587-95 or equivalent in ABB/Siemens or equivalent as approved by GE
M&L for sub main wiring with two runs of 4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- Two runs of 4 Sq mm + one run of 4Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length. Make:- Richa/Finolex/RR Kabel or equivalent as approved by GE Make of caping/casing :- Prestoplast/Finolex/supreme or equivalent as approved by GE
M&L for Exhaust fan of 300mm sweep metal body with metal louvers fixed with wall all as specified and directed. Make : Bajaj/CG/usha or equivalent as approved by GE
M&L for 25 Ltrs water storage electric Geyser 230 Volts AC incl fixing to wall with 04 Nos metal fastners 12mm dia complete all as specified. Make : Bajaj/CG/usha or equivalent as approved by GE
M&L for laying of LT UG cable , XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 3.5 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. Make: RR Kabel/RPG/Finolex or equivalent as approved by GE
M&L for fine river washed sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
Supply and laying tubes light grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 40mm dia bore complete all as specified and as directed. Make: Jindal/Prakash surya/TATA or equivalent as approved by GE
M&L for cutting/ digging og existing hard surface of cement concrete/ Bituminos road of size not less than 45cm in width and 20cm deep for laying of GI pipe and making good to the disturded surfaces by providing PCC for same material after laying of pipe line and returing filling of soil complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed.
SHRI MADAN SINGH
VAISHNO ASSOCIATES
M/S RAHUL TRADING CO.
Shri Atoshe Tuccu
M/S MUGHATOLI AYE
M/S MOTI LAL SHARMA
M/S MUNGA LAL PRASAD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .