Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.2 LAccepted-Finance 256 MUNDHELA KHURD NEW DELHI 73 | WEST | DELHI | 110008 | ₹2.2 L | 1 | Accepted-Finance 1 |
| 2 | 2₹2.3 L+₹10,486.28 (4.71%)Rejected-Finance NULL | ₹2.3 L+₹10,486.28 (4.71%) | 2 | Rejected-Finance 2 |
| 3 | 3₹2.4 L+₹21,498.41 (9.65%)Rejected-Finance | ₹2.4 L+₹21,498.41 (9.65%) | 3 | Rejected-Finance 3 |
| 4 | 4₹2.5 L+₹27,344.74 (12.3%)Rejected-Finance KAUTILYA APPT MIG 133 PKT B PH II SEC 14 DWARKA NEW DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | ₹2.5 L+₹27,344.74 (12.3%) | 4 | Rejected-Finance 4 |
| 5 | 5₹2.6 L+₹33,902.53 (15.2%)Rejected-Finance 0 KALAMBAGH CHOWK MUZAFFARPUR BIHAR 842002 UDYAM BR 23 0013096 | MUZAFFARPUR | BIHAR | 842002 | ₹2.6 L+₹33,902.53 (15.2%) | 5 | Rejected-Finance 5 |
Tender Value
₹3.1 L
EMD Value
₹6,200
Closing Date
3 Jul 2026, 3:00 pmClosed
EEE/KPZ
EEE/KPZ
Provision of lighting arrangement at near H.no 78 Park wali gali Haiderpur, back side of MCD School shalimar village, Sahipur Mandir wali gali near H.no- 30C an 30D, H.no- 29A Sahipur an H.no- 18A(Near Koyla Depot) Sahipur in ward 55 under Keshav Pu
2026_MCD_282151_1
TC/ENGG./EEE/KPZ/2026-27/14.2
Open Tender
Electrical Works
Percentage
60 days
EEE/KPZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹6,200
3 Jul 2026
26 Jun 2026
3 Jul 2026
26 Jun 2026
3 Jul 2026
26 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ABC | |||||
| 1.01 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt ) as required. | 7 | Each | 5,958 | ₹41,706 |
| 1.02 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/cable as required. | 118 | Metre | 50 | ₹5,900 |
| 1.03 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 Sq mm | 55 | Metre | 47 | ₹2,585 |
| 1.04 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Upto 35 Sq mm | 195 | Metre | 36 | ₹7,020 |
| 1.05 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) | 35 | Metre | 289 | ₹10,115 |
| 1.06 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) | 20 | Metre | 136 | ₹2,720 |
| 1.07 | Supply of XLPE insulated PVC sheathed AL. conductor armoured Cable 1.1 KV grade conforming to IS-7098 of following size- (a) 2X6 Sq mm | 250 | Metre | 95 | ₹23,750 |
| 1.08 | Supplying, Installation, Testing & Commissioning of 40 watt Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz,Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angleas per IESNA type I/II/III as per the width of the road
and the project requirement., suitable to fit in up to65mm dia pipe, life time (LED,Driver & electricalcircuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >_135 lm/Watt output . LM79 & LM80 Test
report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | 14 | Each | 1,886 | ₹26,404 |
| 1.09 | Fabrication , supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required | 6 | Each | 1,380 | ₹8,280 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
TenderCondition1.pdf
Tender Documents • 0.57 MB
MCD_GCC_Circulars2025Updated.pdf
Tender Documents • 14.71 MB
BOQ_329200.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .