| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹27.0 L+₹1.7 L (6.53%)Rejected-AOC CHENNAI | L2 | Rejected-AOC Rejected | |
| 3 | L3₹27.2 L+₹1.8 L (7.05%)Rejected-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹29.2 L+₹3.8 L (14.9%)Rejected-AOC 16 176 A BHARATHI PURAM NAGAI NAGAR DINDUGUL 3 | DINDUGUL | DINDIGUL | TAMIL NADU | L4 | Rejected-AOC Rejected | |
| 5 | Rejected-Technical 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | - | Rejected-Technical All necessary documents as per NIT not received , solvency and working capital are more than 2 years old |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
29 Jun 2021, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services INS Adyar Old Building Fort St George Rajaji Salai Chennai 600 009
PROVISION OF 22KV OUTDOOR HT VCB AND 22 KV HT STANDBY UG CABLE FROM TOP TO VCB AND TRANSFORMER AT INS PARUNDU, RAMNAD UNDER GE TIRUNELVELI
2021_MES_437513_3
CWE/NAVY/TVL OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
TIRUNELVELI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE TIRUNELVELI
₹54,000
Yes
31 Jul 2021
15 Jun 2021
30 Jun 2021
15 Jun 2021
29 Jun 2021
15 Jun 2021
Amount
Supply, laying and testing of XLPE cables, insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor , 22KV of size 3.0 core 185 sqmm, complete all as specified and directed. Note: Excavation, earthwork, sand filling and brick protection shall be measured and paid for seperately.
Excavation in trenches in hard/dense soil not exceeding 1.50 metre wide and not exceeding 1.5 metre in depth for laying cables and getting out complete all as specified as directed
Returning, filling, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm each, soft / loose soil in trenches after the pipes have been laid and tested complete all as specified and as directed.
Removing excavated soil to a distance exceeding 50 metres and depositing where directed at level not exceeding 1.50 metre above the starting point complete all as specified and as directed.
Supply and spread fine river sand in trenches for cable cushioning on top and bottom of cable as specified.for cable protection complete all as specified and directed. Note: Only punned thickness of river sand shall be measured
Supply only bricks, common burnt clay building bricks, subclass `B’ designation 75, old size , complete all as specified and directed.
Supply and fixing of Cable jointing kit for 22 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm all as specified and directed.
Supply and fixing of Cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm all as specified and directed.
Material and labour for 150mm bore "light grade" galvanised tubes with all fittings, laid in trenches complete all as specified and as directed by the Engineer-in-Charge
Material and Labour for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amp, suitable for 22/33 KV, complete all as specified and as directed by the Engineer-in-Charge
Material and Labour for aluminium conductor steel reinforced, complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing for Cable route indicators of size 200x150x6mm thick made of GI with letter embosed as LT/HT UG cable MES fixed to MS angle of size 40 x 40 x 6mm, 85 cm long embedded in PCC block of size 66 x 66 x 30cm (L x W x H )in PCC 1:3:6 type C1 using 20mm graded stone aggregate including painting of exposed surfaces with two coats of synthetic enamel paint over one coat of red oxide primer placing at every 50m distance in the direction of cable and each turning of cable complete all as directed by Engineer - in - charge.
Material and labour for earthing complete with copper earth plate of size 60 cm x 60 cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to 20mm x 3mm copper strip by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point 20mm bore GI medium grade watering pipe with funnel including charcoal dust, salt, all as shown in electrical plate No 3 of SSR Part - I (2009) Specifications complete with necessary earth work in any type of soil, removal to a distance n.exc 50 m, including testing on completion, PCC chambers in PCC 1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR / CRS steel bars at 140mm C/C bothway and lifting handle GI funnel complete all as specified and as directed by Engineer-in-Charge. Note : The cost of excavation, earth work, PCC pit, CI cover, funnel, watering pipe, wire mesh, charcoal dust, common salt, GI pipe as protection to earth lead strip shall be deemed to be included in the quoted rate.
Supply installation, testing and commissonig of 22KV HT outdoor type Horizontal draw-out vacuum circuit breaker panel, 1250A, 50 Hz, 3 pole, 25 KA with CT, PT, protection relays including making necessary cable termination, earthing connection and connected civil works. Note: (a) Panel shall be manufactured by OEM authorised system integrators / core component panel builders only (b) VCB make shall be of any makes as given in PS (c) The vacuum interrupter, breaker, protection relays shall be indigenous make
Technical details: VACUUM CIRCUIT BREAKER : Rated voltage : 22KV : 3phase, Rated current 1250A, fault level : 25KA, Rated frequency : 50Hz, Tripping coil and closing coil : 110V DV, spring charging motor : 230V AC / DC Auzillary contacts : 6NO : 6NC Quantity - 01 Nos CURRENT TRANSFORMER:- Primary : 100A, Number of cores: 2, Secondary -5-5A, Burden M-15 VA (Single phase), Core 1M-CL0.2s, Burden P-15 VA (Single phase), Core 2P-5P10, Wound Primary BIL:24/50/125. , Quantity - 03 Nos. POTENTIAL TRANSFORMER: Primary : 22KV/√3, Number of cores:2, Secondary:110V/√3/110V√3, Burden M:50VA (Single Phase), Core 1M-Class 0.2, Burden M:50VA (single phase) Core 2P:CL 3P, Wound Primary, Fixed installation, Wound Primary BIL: 24/50/125. Quantity -03 Nos
PROTECTION RELAYS: (a) Master Trip Relay 86-VAJH13, Qty-01 Nos (b) Protection Relay OC/EF -(50/51) (50N/51N) + TCS 27-UV/59-OV-P3U30 - Multifunction Relay with IEC 61850 ed2 , Quantity-01 Nos. (c) Anti Pumping contactor, Qty-01 nos (d) Arc Protection replay-VAMP 125 Quantity-01 Nos (e) AC & DC superision Relays, Qty-02 Nos MONITORING DEVICES: (a) Ammeter & Voltmeter. Quantity-01 Nos. (b) Indication Lamp VCB ON/OFF/TRIP/Auto trip/SCH/TCH. Quantity-01 Set. (c) RYB Indication lamps, Qty-01 set (d) 8 window announciator and Hooter. Quantity-01 Nos
MANDATORY ACCESSORIES:- (a) Breaker Control Switch (Close-Neutral-Trip). Qty-01No. (b) Emergency push button. Qty-01 No (c) Local / Remote control switch, Quantity-01 No. (d) Toggle Switch-Heater ON/OFF, Quantity-01 No (e) Door limit switch. Quantity-01 No (f) Surge Arrester, 24KV, 10KA, Qty-03 No. (g) Power Pack (230V AC/110V DC), Quantity-01 No (h) Pulg & socket with switch-single phase, Quantity-1 No (j) Heater-230V AC, 80W, Quantity-03 No. (k) Thermostat. Quantity -01 No (m) Control MCBs-AC/DC, Disconnecting type terminal Block, Non-disconnecting type terminal Block, 2.5 sqmm Cu wire for CT wiring, 1.5 sqmm Cu wire for PT/AC/DC wiring (Black, grey)-RYB, Communication cables, wiring Accessories, Panel accessories, Epoxy Insulator.
ALUMINIUM BUSBAR: Main connection -2x50x12.5(mm), Earth connection:1x40x6 (mm), PT & Eearth droppers: 1x25x6(mm) PANEL CONSTRUCTION:- Ingress protection : IP 55, Thickness of non load bearing:2mm, thickness of load bearing & Base-3mm, Thickness of mesh & covers: 1:6mm,
VVM CONSTRUCTIONS
SUPER COOL
S KUMARAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .