Executive Engineer PHE Mechanical Rural Division
Executive Engineer PHE Mechanical Rural Division
Urgent Electrical works to be carried out at WSS Naderbagh, Baba Wayil and GB Preng
2021_PHE_132324_2
PHE/MRD/TS/ 33 of 07/2021
Open Tender
Miscellaneous Works
Item Rate
3 days
Srinagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
Yes
Executive Engineer PHE Mechanical Rural Division
₹2,142
Yes
5 Aug 2021
29 Jul 2021
5 Aug 2021
29 Jul 2021
3 Aug 2021
29 Jul 2021
Amount
Replacement of damaged 250A MCCB in the control panelat WSS Baba Wayilby way of Providing, fitting, Installation, Testing & Commissioning of 320Amp MCCB having following specifications: Type/ Rating : DN3B-400D Make : L&T Breaking Capacity : 36 kA (Icu) Thermal Release Range : 250A-320A Voltage : 415 V Frequency : 50 Hz Poles : 04 The job is inclusive of providing, fixing and tightening of nuts, bolts & washers, connecting of main incoming and outgoing connections as per site requirement, then finally testing of the MCCB on full load at site. The job also includes cost on a/c of all transportation charges, tools & tackles and skilled labour component.
Replacement of damaged Fusses in the control panel at WSS Baba Wayil by way of Providing & fitting of new 100Amp DIN Type Fuse Links HN Type of Size 00. (Make L&T)
Replacement of damaged Fusses in the control panel at WSS Naderbagh by way of Providing & fitting of new 63Amp DIN Type Fuse Links HN Type of Size 00. (Make L&T)
Replacement of damaged MCCB with box at WSS Naderbagh by way of Providing, fitting, Installation, Testing & Commissioning of MCCB 160A, 4-pole, 3-phase 415 ± 15% volts, Frequency: 50± 3% C/S current 50 KA breaking capacity (makes are L&T / Schneider). The MCCB shall be housed in a panel fabricated out of 14SW, duly given two coats of grey colour powder coating for outdoor suitable for the installation of the MCCB. The panel is to be installed on the ST-Pole which include clamps, nuts & bolts etcas per the site requirement. The job is inclusive of Providing & fitting of 50Sqmm Copper thimbles (04No’s) and 95Sqmm Aluminium thimbles (04 No’s)of reputed make for end termination of the electric power cables by crimping tool. The acceptable makes are L&T / Schneider.
Replacement of old damaged Link setsat WSS G.B. Prang by way of first taking due clearance, shut down from PDD then Providing &Fitting of 11 KV heavy duty link set complete of reputed make after replacement of the damaged link set. The job includes cost on account of Nuts, bolts, Washers, skilled labour, transportation charges, tools and tackles, ladders, safety harness etc. required as per site requirement.
Providing of Portable 15-Feet long Telescopic Folding Aluminium Ladder (of reputed make) along with 15 feet long Link rod and 11KV HT Glove pair as per ISI Spec:4770-1968/91. (01 No. Each for WSS G.B. Prang)
M/S KHAN ENGINEERING WORKS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .