Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹34.0 L+₹5.6 L (19.9%)Rejected-AOC CHATAI SHEEP WARD NO 07 NEW MARKET ROAD AHIWARA DURG CHHATTISGARH 490036 | DURG | CHHATTISGARH | 490036 | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹34.4 L+₹6.0 L (21.2%)Rejected-AOC | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹35.5 L+₹7.1 L (25.1%)Rejected-AOC | L4 | Rejected-AOC L4 Bidder | |
| 5 | L5₹50.9 L+₹22.5 L (79.4%)Rejected-AOC | L5 | Rejected-AOC L5 Bidder |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
27 Jan 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/REPLACEMENT OF ALL TYPES OF DG SET AND AMF PANEL, AND REPAIR/MAINT/ CALIBRATION OF VCBS/OCBS 33/11 KV AND REPAIR/REPLACEMENT OF HT JOINTS, HT CABLE, SERVICING/MAINT LT VOLTAGE STABILIZER AND OTHER CONNECTED WORKS AND REPAIR/REPLACEMENT OF LT P
2019_MES_309946_1
GE/RND-65/GWL/2019-2020
Open Tender
Civil Works
Item Rate
180 days
GWALIOR
Class D, Cat b(ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹97,000
Yes
21 Feb 2020
27 Dec 2019
28 Jan 2020
27 Dec 2019
27 Jan 2020
14 Jan 2020
Amount
S&F 3 pole AC control power contractor,415 volts, . Phase 50 hz rated operational current 70 TO 100 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed. Make :- Schneider reference to cat part No. LCIE 95 or equivalent in L&T/C&S/Seimens
S&F 3 pole AC control power contractor,415 volts, . Phase 50 hz rated operational current 200 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed. Make :- Schneider reference to cat part No. LCIE 160 or equivalent in L&T/C&S/Seimens
S&F 3 pole AC control power contractor,415 volts, . Phase 50 hz rated operational current 260 AMP TO300 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed. Make :- Schneider reference to cat part No. LCIE 300 or equivalent in L&T/C&S/Seimens
S&F 3 pole AC control power contractor,415 volts, Phase 50 hz rated operational current 400 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed. Make:- Schneider reference to cat part No. LCIE 400 or equivalent in L&T/C&S/Seimens
S&F 3 pole AC control power contractor,415 volts, . Phase 50 hz rated operational current 630 amp. & AC 3 rating confirming to IEC-60947 in AMF Panel as directed. Make :- Schneider reference to cat part No. LCIE 630 or equivalent in L&T/C&S/Seimens
S&F contractor coil MNX-140 Make- L &T/BCH
S&F AVR suitable for 160 to 320 KVA capacity DG set complete. Make- National or equivalent approved.
S&F Voltage relay 415 Volt 3 phase. Make- Teknika/procom
S&F MCCB, four pole 100 Amp current rating and ultimate breaking capacity LCS=100 % Icu 16 KA with thermal magenetic realese and adjustable overload setting having type DPX3 confirming to IS 13947 & IEC- 60947 complete all as specified and directed. Make:- Legrand (DPx3) Cat part No. 420005 or equivalent Schneider/ABB/L&T.
S&F MCCB ,four pole 160 Amp current rating and ultimate breaking capacity LCS=100 % Icu 36 KA with thermal magenetic realese and adjustable overload setting having type DPX3 confirming to IS 13947 & IEC- 60947 complete all as specified and directed. Make :- Legrand (DPx3) cat part No. 420087 or equivalent Schneider/ABB/L&T.
S&F MCCB ,four pole 250 Amp current rating and ultimate breaking caapacity LCS=100 % Icu 36KA with thermal magenetic realese and adjustable overload setting having type DPX3 confirming to IS 13947 & IEC- 60947 complete all as specified and directed. Make:- Legrand (DPx3) cat part No. 420239 or equivalent Schneider/ABB/L&T.
S&F automatically /Manual transfer switch confirm to IEC 60947-1 with inbuilt time delay ,250 Amps rating, 415 volts four pole with complete all as directed. Make: Havells, Cat part No. IHYTCDE250 or equivalent in Hager/legrand.
S&F off load change over switch 4 pole 415 volts 100 Amp rating advance neutral, withsteel enclosure side handle assembly having door interloc and padlocking arrangement complete all as directed. Make:-Havells Cat part No.: IHBFFE0100 or equivalent in C&S electric/Schneider.
S&F off load change over switch 4 pole 415 volts 200 Amp rating advance neutral, open execution handle assembly having door interlock and padlocking arrangement complete all as directed. Make :- Havells Cat part No.: IHBFFE0200 or equivalent in C&S electric/Schneider
S&F off load change over switch 4 pole 415 volts 400 Amp rating advance neutral, open execution handel assembly having door interloc and padlocking arrangement complete all as directed. Make:- Havells Cat part No.: IHBFFE0400 or equivalent in C&S electric/Schneider
S&F digital voltmeter (0.5) 3 phase 0 to 500 volts mains opetated having 2.5 digit LED/LCD/FND display mounting type for measuring phase volts all as per specified.
S&F digital ammeter (0.5) 3 phase digital meter range 0-300 Amp CT operated having 3.5 digit LED/LCD/FND display mounting type for measuring phase current all as per specified.
S&F digital frequency meter (0.2) having LED/LCD/FND display mounting type for 50-60 hz all as per specified.
S&F self sequentional starting relay unit 24 volts DC with dual interlocking timer for self on (3 sec 15 sec) adjacent independently with another timer for set fails to safety alarm all specified.
S&F led illuminating flush push buttons 22.5 mm dia in three coloures as red, yellow & blue without contact block and carrier all as specified. Make:- BCH/C&S Electric
S&F led pilot lamp head 22.5 mm dia in three colours as red, yellow. And blue without contact block and carriers all as specified. Make :- BCH/C&S Electric
S&F plug in relay universal type 11 pin contact rating 10 amps 24 volts DC and mechenical indicator with manual testing /latching lever complete all as specified. Make :- BCH cat no. ARPU2 24 D or equivalent in C&S electric/rishab
S&F plug in relay universal type 11 pin contact rating 10 amps 24 volts AC and mechenical indicator with manual testing /latching lever complete all as specified. Make :- BCH Cat No. ARPU2 24 D or equivalent in C&S electric/rishab.
S&F of plug in relay universal type 11 pin contact rating 10 amps 230 volts DC and mechenical indicator with manual testing /latching lever complete all as specified. Make :- BCH cat No. ARPU2 230 D or equivalent in C&S electric/rishab
S&F of V-belt suitable for radiator fan water pump assembly from 25 KVA TO 75 KVA DG set capacity . Make:- fenner or equivalent in V-guard
All as per ser item No. 26.00 above but 110 KVA to 320 KVA.
S&F in repair of self starter 24 volts type SM-130-24 Volts 7.5 KW. Make :-lukas/boscop
S&F in repair of self starter 12 Volts Suitable for DG set 160/250/320 KVA. Make :-lukas/boscop
S&F in repair of maintence free battery 12 Volts,180 AH. Make- Exide Express/Amron
S&F in repair of maintence free battery 12 Volts, 92 AH Make- Exide Express/Amron
S&F in repair battery charger auto type 24 Volts x 10 amps complete with all accessories. Make:-Hira/Luxmi.
S&F in repair battery charger auto type 12 Volts x 8 amps complete with all accessories. Make :- Hira/Luxmi.
Distiled water packed in containers.
S&F acid Mixture gravity 1200-1220 (Electrolite) packed in 1 ltr bottle packing all as specified and directed.
S&F in repair radiator and shroud assy 25KVA to 75 KVA DG set capacity. Make:-Kirloskar, part No. 4948110160 or equivalent in benque/ashoka leyland.
S&F of repair radiator and shroud assy 160 KVA to 320 KVA DG set capacity. Make:- Kirloskar, part No. 4948110250 or equivalent in benque/ashoka leyland.
M&L for battrey lead heavy duty multi strands copper size 25 sq mm 4 feet long in red or black colour all as specified.
S&F of heavy duty brass terminals suitable for 24 Volts /12 Volts batteries all as per specified.
S&F of flywheel ring for 160 KVA to 320 KVA capacity DG Set all as per specified .
S&F in repair to 24 volts self starter assembly by taking out from DG Set of any make and size including transporting the same to workshop for repair . The following spare parts are replaced by new one like Auxiliry field coil 02 Nos, DE bearing bush, CE bush armature, carboun brush and clutch assembly including petrol wash all as specified. Refixing the same after repair and testing on full load all as specified and directed.
Description all as per item No. 41.00 above but for 12 Volts self starter assembly all as specified.
M&L for repair to radiator assy of any make and design by taking out from DG set varies from 110 KVA to 160 KVA capacity transported to work shop for repair . The repair work involves opening of upper & lower cabinet of radiators by means of welding/soldering ,descalling the assy tank by filling ip and stearing the decalling solutions (i.e soda and concentrated acid) with high pressure , cleaning the tubes with wire brushes and high water pressure. After cleaning , the leaking tubes and raditor body will be repaired with soldering and brazing on approciate place in suficient size and re assembled complete in unique shape all as directed. Testing the leaking portion with high water pressure and painting with one coats of anti-corrosive paint and two coats of synthetic enamelled paint all as directed. Refixing the radiator of DG Set by means of nut, bolts, washers and packing etc. and testing on full load complete all as specified and directed.
All as per item No. 43.00 above but for radiator assembly varies from 250 KVA to 320 KVA capacity all as specified.
S&F for servicing /preventive maintence of DG set of capacity 25KVA to 110 KVA at site comprising of the following check & re adjust valve tapped clearence in cold ,drain out used engine oil by opening the oil chamber ,cleaning the chamber throughly, pouring the new engine oil refixing the chamber cover with new gasket , replacement of diesel filter ,oil filter, air filter,cleaning the diesel tank, clean radiator fins & air to air after coller & AVM pads , check rubber seal and hose pipes replace if found defective, check coupling disc on injection pump, check speed governer for proper functioning and lubricating leakage, check clean air filter element ,check functioning of engine protection unit repair to instruments panel, Check and repair of any leakage etc. and replacement of small minor items such as nut, bolts, washers, etc are included in quoted rates of sch A' . The above checks are strictly followed in the duration of six month interval of every 250 hrs of run all as specified and as directed. Note: Engine oil and filters shall be measured & paid separately under respective items.
All as per item No. 45.00 but for 160 KVA to 320 KVA capacity DG Set.
Supply and filling in repair of engine oil 20 W 40 and as type required at site. Make- Servo & equivelent approved.
S&F in repair of rotary barrel pumps. Make- Hira
Supply of cotton cloth for cleaning of DG set
S&F in repair of HRC fuse DIN type breaking cap 100to 600 Amp with fuse base for DIN type HRC fuse links.
Supply and filling of coolent for radiator DAFC 30 %. Make- Servo or equivalent apporoved.
S&F in repair of automatic digital control unit of DG set. Make-Kirloskar/Procom
S&F in repair of mono block pump for lifting of diesel to tank of cap 1 HP single phase. Make-Crompton/Kirloskar
S&F in repair fuel Filter 100 KVA to 320 KVA.
S&F in repair Suction line fuel filter to FIP 25 KVA to 75 KVA.
S&F in repair Hose fuel filter to FIP 100 KVA to 320 KVA.
S&F in repair Return Line Engine to Fuel Tank 25 KVA to 320 KVA.
S&F in repair Oil Filter Assy 25 to 320 KVA.
S&F in repair Lubricating oil pump assy with driving gear 25 KVA to 320 KVA.
S&F in repair Set of rubber ‘O’ ring 25 KVA to 320 KVA.
S&F in repair Set of joints 25 KVA to 320 KVA.
S&F in repair Pipe air cleaner to turbocharger 25 KVA to 320 KVA.
BLANK
S&F for servicing repairing maintenance of alternator assembly of DG set 160 KVA decoupling alternator from DG set & strip opening of the alternator replacement of carbon bush holder, with carbon bush, ball bearings, mospeds, capacitor, rectifiers & refixing the same in original position complete all specified & directed.
Supply only petroleum jelly
Disconnecting & taking out non functional VCB and SF-6 Braker of any description and any make of rating 33 KV,1250 Amps dismantling / opening of the VC/SF-6 breaker for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/servicing including CT testing (33 KV), PT testing (33/11KV), numeric breaker protection relay testing (33 KV), auxiliary relay testing in 33 KV panels (OTI, WTI, Bush) differential protection relay testing etc and its testing complete all as specified and directed. Note :-1. The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ item No. 73 to 87 as `supply only ‘. Note :-2. The quoted rates shall also included all testings mentioned above after necessary repairs from the authorized service agency.
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
Supply only Micro switch
Supply only Motor cut of limit switch
Supply only Closing coil 110 VDC
Supply only Triping coil 110 VDC
Supply only Segment gear Assembly (Full Teeth-Big )
Supply only Triping Half shaft
Supply only Trip Catch with linkage assembly
Supply only Spring charging motor assembly 230 VAC
Supply only Motor Gear Box Assembly.
Supply only Closing Half shaft
Supply only Auxiliary switch assly
Supply only Ratchet wheel with key & Set of pawls with pin
Supply only Motor contractor
Supply only Limit switch
Supply only Set of 'O' ring set
Disconnecting and taking down old unserviceable control cable any size any description and supply, fixing, testingand commissioning of LT 1100 volts 2.5 Sqmm 4 core copper conductor armoured cable connecting the cable in positioning properly by providing suitable new copper lugs GI bolts & Nuts washers etc complete all as specified and directed. Make:- Gloster, Havells, Finolex, Polycab
Disconnecting and taking down the unserviceable/damaged/ non operational existing lightening arrestor of 33KV Switching yard and supply , fixing & testing and commissioning of new lightening arrestor 33KV, 10KA suitable for 33KV and maximum voltage of 36KV for (MRS) with solid earthed natural system comprising of Metal oxide elements suitable for ACSR Conductor alongwith the insulating base structural work and all as specified and directed. Make : Oblelum/ jaipuriya/GE/ATLAS.
Taking down existing unserviceable air break switch gang operated outdoor type upto ratio 400 Amps of 33 KV and S&F new air break switch gang operated Triple pole mechanically operated mounted on insulator and steel frame with operated mechanism welded from tubular rotating type switch . all as specified and directed. Make:-Jaipuria Brothers/Atlas/Pactil/HEI
Taking down existing unserviceable air break switch gang operated outdoor type upto ratio 200 Amps of 11 KV and S&F new air break switch gang operated triple pole, with Dropout Fuse set insulaters mechanically operated mounted on insulator and steel frame with operated mechanism welded from tubular rotating all as specified and directed. Make: Jaipuria Brothers/Atlas/Pactil/HEI
Taking down existing unserviceable drop out fuse set outdoor type upto ratio 400 Amps of 33 KV and supply and fix Drop out fuse set mounted on insulator and steel frame complete all as specified and directed. Make:-Jaipuria /pactil /atlas
M&L for rendering 15 mm thick in CM 1:6 & finished the surface fair & even complete all as specified and directed.
All as per ser item No. 93.00 above but 10 mm thick in CM 1:4.
Disconnecting GOD of capacity 33 KV, dismantling of GOD for complete repair & overhauling and checking the serviceability of spares and operating mechanism and replacement of defective/worn out spare parts for making the GOD functional including reassembling of operating mechanism oiling & greasing of moving parts, fine setting of mechanism, making the GOD perfect operational in manual mode complete all as specified and directed. (Note :- The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ item No. 96 to 100 as `supply only ‘
Supply only Male contact
Supply only Female Contact
Supply only Tinned copper flexible jumper
Supply only M S Carrier
Supply only Back Connector plate
11 KV VCBs Disconnecting and taking out old unserviceable Ammeter of any description and in any position and supply, fixing, connecting, testing and commissioning of new digital Ammeter size as per site required of range suitable for panel, 11 KV HT VCB complete all as specied and directed.
All as per ser item No. 101.00 above but Volt Meter.
Disconnecting & taking out non functional VCB/OCB of any description and any make of rating 11 KV, 400 Amps to 800 Amps dismantling/opening of the VCB for servicing/over hauling taking out and removing unserviceable/defective parts including cleaning and servicing greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after over hauling /servicing and its testing complete all as specified and directed by Engr-in-charge. Note: - The quoted rates of the contractor includes for fixing of serviceable parts & replacment of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch 'A' ser item No. 104.00 to 136.00 as supply only)
Supply only Sleeves for Epoxy mould. Make :-CG/Schneider
Supply only isolating Contacts (Flower Type). Make :- CG/Schneider
Supply only Closing shaft. Make:-CG/Schneider
Supply only Triping shaft. Make :-CG/Schneider
Supply only Big Gear Assembly. Make ;-CG/Schneider
Supply only Small Gear Assembly. Make:-CG/Schneider
Supply only Motor Cut off limit switch. Make:-CG/Schneider
Supply only Micro switch assembly (ZZ). Make:-CG/Schneider
Supply only Breaker Control switch. Make:-CG/Schneider
Supply only Spring charging Motor 230 VAC. Make :-CG/Schneider
Supply only Segment Gear Assembly (squir type). Make:-CG/Schneider
Supply only Trips catch assembly. Make:-CG/Schneider
Supply only Bus bar support insulator. 61mm dia. Make:-CG/Schneider
Supply only Epoxy bushing insulator for 11 KV(Drive rod). Make:-CG/Schneider
Supply only ON/OFF push button Assembly. Make:-CG/Schneider
Supply only Charge dischasge indicator assembly. Make:-CG/Schneider
Supply only Auxiliary switch 7NO-7NC. Make:-CG/Schneider
Supply only LED Indicating lamps RED,Green,Amber white , 30 VDC. Make:-CG/Schneider
Supply only LED Indicating lamps Blue 230 VAC spring charging. Make:-CG/Schneider
Supply only LED Indicating lamps Red,Yellow,110 VAC. Make:-CG/Schneider
Supply only Indicating lamps Blue 110 VAC. Make:-CG/Schneider
Supply only CGI 14N Numerical Relay Make:-CG/Schneider.L&T,Aroba)
Supply only Spring charging handle. Make:-CG/Schneider
Supply only Trip circuit supervision relays CGL Make 30VDC. Make:-CG/Schneider
Supply only Master trip relay CGL makr 30VDC. Make:-CG/Schneider
Supply only Current Transformar (CT) 200-100/5. Make:-CG/Schneider
Supply only Closing / Trip coil. Make:-CG/Schneider
Supply only Spout bushing upper 11kv 400 to 800A with CC parts. Make:-CG/Schneider
Supply only Spout bushing Lower 11kv 400 to 800A with CC parts. Make:-CG/Schneider
Supply only CRC Spry for lubricant. Make:-CG/Schneider
Supply only VacuumInterrupter
Decarbonising\cleaning complete HT 11 KV 3 Phase bus bar chamber of HT panel electrical connection rods complete HT VCB switch gear arrangement incoming and out going breaker after removing complete monoplast putty cleaning with CTC solution and ensure proper decarbonising refixing the same after applying beacon (red) insulating compound to the spout checking all connections tightening the nut and bolts washers of incoming and out going connections complete all as specified and directed. Note:- The rate is inclusive for replacement of worn out bolts nuts & washers, lugs, glands etc
Dismantling & Refixing after repair of wiring of Numerical braker protections relay testing various make 11 KV relays all as specified and directed
Dismantling & Refixing after repair of current transformar testing various make 11 KV relays all as specified and directed
Dismantling & Refixing after repair of protection PTs testing various make 11 KV relays all as specified and directed
Dismantling & Refixing after repair of Auxiliary relay testing various make 11/33 KV panels all as specified and directed
Dismantling and Taking out old Numerical relay wiring any type and any description and replace new wring materials, lugs,ferrule, cable tie and 2.5 Sqmm wire. Auxiliary relay testing various make 11/33 KV panels all as specified and directed
Dismantling of inter panel wring testing and checking of AC/DC supply. Auxiliary relay testing various make 11/33 KV panels all as specified and directed
Disconnection of transformer of cap 3.15 MVA out door type 33/11 KV from LV/HV side including earthing GI strips and other DC sources, control wiring for relays, protection, metering etc and taking down transformer from plinth with the help of crane for all as specified and directed.
Transportation of Transformer from site E/M yard to workshop and from workshop to site/E/M yard for repairing/ depositing etc of capacity 3.15 MVA all as specified and directed.
M&L for draining out transformer oil from the transformer of cap3.15 5MVA out door in a clean barrel and disconnection of internal electrical connection by taking out the top cover complete, cleaning of tank, removal of sludge etc all as specified and directed.
M&L for connecting all the internal connection, soldering, brazing of HV/LV connections by silver electrodes including replacement of leads complete by providing tubular insulation of tap changer assembly and its connections and tanking of complete assembly in tank with suitable locking arrangements Re-fixing the top cover of transformer including the other accessories such as OTI, WTI and connecting with protection system and making the transformer absolute leak proof for 2 to 3.15 MVA transformer all as specified and directed.
M&L for cleaning the conservator assembly & cooling fins by removing sludge clogging material with the help of air blast complete including re-fixing of conservator & cooling fins in original position with nuts, bolts washer, for 3.15 MVA transformer all as specified and directed.
Dismantling and taking down breather assembly of any capacity and size and replacement of breather to the transformer and filling of fresh Silica Jel all as specified and directed.
M&L for ovening of complete assembly including HV/LV coils of transformer 2 to 3.15 MVA in oven for at least 72 Hrs for achieving desired insulation value and complete removal of assembly (Note re-ovening shall be done if the desired result was not found with out any extra cost) all as specified and directed.
S&F cork sheet gas kit cut to shape for the top covers radiator valves conservator assembly buchhloz and other required places of the transformer of capacity 3.15 MVA 33/11 KV complete all as specified and directed.
M&L Installation, commissioning, testing of 3.15 MVA transformer by connecting all HT 33/11 KV connections, earthing connections, control cables for various protections, indications, meatering, connection and buchhloz connections and testing all as specified and directed.
M&L for cleaning of surface of transformer of capacity 2 to 3.15 MVA by scrapping out old paint and painting of transformer by two coats of synthetic enamel gray paint externally including writing of SM/MES No on the transformer complete all as specified and directed.
S&F in repairs OTI & WTI for 3.15 MVA transformer all as specified and directed.
S&F in repairs HT bushing 33KV complete with copper spindal and connected items all as specified.
S&F in repairs HT bushing 11KV complete with copper spindal and connected items all as specified.
Supply and installation automatic DC unintrupted power supply system for 24/30 v DC for 33/11 KV protection equipments with following specification:- (A) Electrical specifications:- (i) AC input voltage 230V RANGE 180V TO 264 V. (ii) AC input friquency ( nominal) 50 HZ (iii) DC output voltage (nominal for load) 24 to 30 VDC. (iv) DC output float voltage for battery 40.5 V. (v) DC output boost voltage for battery 43.2v (vi) DC out put current for load (nominal) 8A. (vii) DC output current for (nominal) for battery 15A. (B) PROTECTION (i) AC input supply - fuse. (ii) DC output Short circuit supply/overload - fully protected. (iii) Reverse battery protection - yes. (C) ELECTRICAL SPECIFICATION (i) AC input supply/mains available - green led. (ii) DC output - green led (iii) FLOTE CHARGED MODE - GREEN LED. (iv) BOOST CHARGED MODE - YELLOW (v) Battery dischharged/low - red led (vi) Battery reverse polarity - red led. Make -AE/SEIMENS/POWER EQUIPMENT/ REL
S&F in repair battery 12v 150 AH Lead acid low maintanance complete all as specified and directed. Make - EXIDE/SF/TATA/AMCO
M&L for pouring fresh transformer oil confirming to IS 335 in transformer of any capacity complete duly filtered having dielectric strength not less than 60 KV all as specified and directed. Make power oil/savita/IOC/BPL
M&L for sand filling with clean dry find sand unwashed including gently punned around cables in trenches for cable protection complete all as specified and directed.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete all as specified and directed.
Disconnecting, taking out and removing old existing unserviceable underground, HT 11 KV cable of any description and in any position complete including taking down protection pipe etc all as specified and directed by the Engineer-in-Charge for the 95/120 sqmm sizes:
Supply, laying, jointing & testing 11 KV (Earthed) , aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having following cross sectional area 120 Sqmm 3 core complete all as specified and directed.
S&F in repair jointing and testing for outdoor type heat shrinkable end termination joint suitable for 11 KV, XLPE insulated cable of 120 Sqmm 3 core.complete material and labour including cutting the faulty outdoor end termination joint of any description and in any position. Make : Denson/M-Seal/Cabseal/Rey-chem
S&F Jointing and testing of Straight through heat shrinkable end termination joint suitable for 11 KV, XLPE/PVC insulated cable size of 120 sqmm complete material and labour including cutting the faulty straight through of any description and in any position. Make : Denson/M-Seal/Cabseal/Rey-chem
S&F in repair Jointing and testing of Straight through heat shrinkable end termination joint suitable for 33 KV, XLPE/PVC insulated cable size of 120 sqmm complete material and labour including cutting the faulty straight through of any description and in any position. Make : Denson/M-Seal/Cabseal./Rey-chem Note for item No 164 to 166 :- (i) All Necesary T & P Blow lamp, HT Megar shall be arrange by the Contractor. (ii) The contractor will be rectified the joints with in 4 Hrs after detecting the faults in case of failure the panelty of Rs. 1000/- per hours shall be recovered from contractor dues.
Demolition of cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance exc 1.50 Km and n.exc 5.00 Km etc complete all as specified
M & L for 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor finishing even and smooth with using extra cement and making impression of expanded metal, whilst concrete is green over 100 mm thick PCC (1:4:8) type D-2(using 40 mm graded stone aggregate) with and including to make the road surface making good as per existing surface etc complete all as specified and directed.
M&L for dehyderation and filteration of transformer oil to achieve the dielectric strength of transformer oil 50 KV at 4mm gap of sphere complete all as specified and directed.
M&L in replacement, laying & jointing GI water tubing, 100 mm bore,light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed. MAKE : TATA/JINDAL/BST/Prakash
M&L for repair the Unserviceable APFC panel by servicing and renewal of burnt / unserviceable Power/Control wiring and spare parts to achieve Power Factor upto 0.99 for the capacity 75 KVAR complete all as specifies and directed.
All as per ser item No 171.00 above but for capacity 150 KVAR.
All as per ser item No 171.00 above but for capacity 175 KVAR. Note for item 171 to 173:- (i) Rate quoted by contractor deemed to be included for renewal of burnt copper power wiring, copper lugs and other necessary screws,nuts and bolts etc. (ii) The spare part to be replaced shall be measurred and paid separately as per respective items of the BoQ. (iii) Penalty will be charged @ Rs 100.00/day/panel till the completion of the work to contractor in case of falling average PF below 0.98 after the period of two months of the date of acceptance of tender.
S&F in repairs 5 KVAR power factor correction capacitor Heavy Duty Long life rectangular box type, self standing units of modular construction with sheet metal enclosure, self healing property, PU resin as impregnant with safety device in the form of pressure sensitive (over pressure) mechanical interrupter including wire for use on 440V (AC), 3 phase, 50 Hz,(Series B32459) AC conformance to Standards IEC 60831-1 2/96, IS 13340 with MPP film with heavy edge including testing, commisioning as in repairs complete all as specified and directed. Make: M/s EPCOS CAT No.-B32459L5005A 11 or equivalent in M/s L&T/M/s Schnieder / M/s ABB / M/s Siemens make
All as per ser item No 174.00 above but of capacity 10 KVAR make M/s EPCOS CAT No.-B32459L5010A 11 or equivalent in M/s L&T / M/s Schnieder/M/s ABB/M/s Siemens.
All as per ser item No 174.00 above but of capacity 15 KVAR make M/s EPCOS CAT No.-B32459L5015A 11 or equivalent in M/s L&T/M/s Schnieder/M/s ABB/M/s Siemens.
All as per ser item No 174.00 above but of capacity 20 KVAR make M/s EPCOS CAT No.-B32459L5020A 11 or equivalent in M/s L&T/M/s Schnieder/M/s ABB/M/s Siemens.
All as per ser item No 174.00 above but of capacity 25 KVAR make M/s EPCOS CAT No.-B32459L5025A 11 or equivalent in M/s L&T/M/s Schnieder/M/s ABB/M/s Siemens.
S&F in repair power capacitor duty contactor 1NO1NC 240 volts suitable for 10 KVAR including testing connecting commissioning complete all as specified and directed. Make:- Cat No. B44066S1011C240N 1 of M/s Epcos or equivalent of M/s L&T or M/s Siemens/M/s Schnieder/M/s ABB make
All as per ser item No. 179.00 above but 16 KVAR make Cat No. B44066S1611C240N 1 of M/s Epcos or equivalent approved.
All as per ser item No. 179.00 above but 33 KVAR make Cat No. B44066S3312C240N 1 of M/s Epcos or equivalent approved.
All as per ser item No.179.00 above but 40 KVAR make Cat No. B44066S4012C240N 1 of M/s Epcos or equivalent approved.
S&F in repair HRC fuse link,Type HG, offset, size F1, 2 - 16 amps cap base/holders complete all as specified and directed. Make: M/s Havells or equivalent of M/s Schneider/ M/s Siemens M/s L&T
All as per ser item No. 183.00 above but size A2, 20 Amps cap.
All as per ser item No. 183.00 above but size A3, 63 Amps cap.
All as per ser item No. 183.00 above but size A4, 125 Amps cap.
S&F in repair in repairs Fuse holder A2 type, suitable for 4 to 32 Amps bolted fuse links complete all as specified and directed. Make: M/s L&T or equivalent of M/s Schneider/ M/s Siemens M/s HPL.
All as per ser item No. 187.00 above but A3 type, suitable for 35 to 63 Amps.
All as per ser item No. 187.00 above but A4 type, suitable for 80 to 125 Amps.
S&F in repairs Solid state relay of 55 to 60 Amp switching the capacitor bank complete all as specified and directed. Make- Angro/Tar.
S&F in repairs thyrestor controller relay 75 amp complete all as specified and directed. Make- Tar/Angro.
S&F in repairs thyrestor controller relay 125 amp complete all as specified and directed. Make- Tar/Angro.
S&F in repair for control wiring of the panel with 1100V 10 Sqmm PVC insulated multistranded single core copper conductor cable (FRLSH) conforming to IS for power circuit, the wire ends will be copper ferruled all as specified and directed. Make- Nicco/Plaza/Havells/Finolex
All as per ser item No 193.00 above but 2.5 Sqmm cable.
S&F in repair digital Ammeter in replacement for measuring alternating current of range : 0 - 200 A flush type 96x96MM size. ACC CL 1.5, Model SMI-96 complete all as specified and directed.
S&F in repair digital Voltmeter in replacement for measuring alternating current voltage of range 0-500 V flush type 96x96MM size complete all as specified and directed.
S&F in repair indoor resin cast ring type current transformer of ratio 800/5 Amps, accuracy - 15VA, Class - 5P10.
M&L for painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified and specified.
S&F in repair for sheet metal work for repair to electric panel doors, bus bar cover and accessories mounting supports for alignment with front door with 2 mm thick MS sheet duly painted two coats of with super enameled paint over one coat of red oxide primer including necessary cutting, welding and fixing complete.
M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6.0mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earthing with GI strip 32 x 6 mm by means of nuts bolts, check nut and washers of galvanised iron protected by 40 mm bore GI pipe (medium grade) and connected to main switch board as directed including concrete pit in PCC (1:3:6) type C1 precast RCC (1:2:4) type B1 cover slab 40x40 Cm x 50mm reinforced with 8 mm dia deformed bar @ 5 cm c/c with one handle for lifting made out of 8 mm dia MS bar, funnel, wire mesh, 20 mm bore GI pipe (medium grade) for watering including charcoal and salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as shown on electrical plate No-3 of SSR Part-I.
S&F in repairs, breaker control switch (Trip-Neutral-close), TNC with 2NO + 2NC SPR RTN complete all as specified and as directed. Make: Cat part No 72009 L&T or equivalent approved.
S&F in repair rotary type A/M Switch, 1 Pole, 2 Way with Off complete all as specified and as directed. Make - KAYCEE/L&T/SIEMENS
S&F Flush head Push Button Green/Red colour with 1 NC Block complete all as specified and as directed. Make - L&T or equivalent approved.
S&F in repair multi-function meter having LCD Display,96 x 96 sq.mm Flush mounted case, accuracy class 1.0 capable of measuring Instantaneous, Average, Maximum and Total Current from 50A to 6000A and voltage from 120V AC to 300V AC Phase to Neutral, Phase to Phase Voltage, Instantaneous, Average, Maximum and Total Active Power KW, Instantaneous, Average, Maximum and Total Reactive Power KVAR, Instantaneous, Average, Maximum and Total Apparent Power KVA, Instantaneous and Total Power Factor, Frequency complete all as specified and as directed. Make - L&T/ Scheinder/Legrand/HPL
S&F in repairs instrument Cooling fan , 3000 RPM, 230 Volts 50 Hz complete within the panel including cutting of a suitable size hole on the panel body and wiring with 1.5 Sqmm copper conductor cable and MCB SPN 6 Amps complete all as specified and as directed.
S&F in repair capacitor cooling Exhaust fan 230 volts complete all as specified and as directed.
S&F in repair LED indicator-R/Y/B/G 240 V AC complete all as specified and as directed.
S&F in repairs MCCB 200 Amps, 3 Pole, 415 V, Adjustable type, with breaking capacity 36 KA including spreader terminals & connected accessories complete as specified & directed. Make :-Legrand/Schnieder / Siemens .
S&F in repairs MCCB 350 Amps, 3 Pole, 415 V, Adjustable type, with breaking capacity 36 KA including spreader terminals & connected accessories complete as specified & directed. Make :-Legrand/Schnieder/Siemens .
S&F in repairs Off load changeover with side handle in sheet enclosure 200 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make:-Havells Cat No-IHBFFE0200 or equivalent Make /L&T/Schnieder / Siemens
S&F in repairs off load changeover with side handle in sheet enclosure 320 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make:-Havells Cat No-IHBFFE0320 or equivalent make /L&T/Schnieder/Siemens
S&F in repairs Off load changeover with side handle in sheet enclosure 400 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells Cat No- IHBFFE0400 or equivalent make /L&T/Schnieder/Siemens.
S&F in repairs busbar chamber in sheet enclosure including aluminium bus bar 100 Amps, TPN, 4 way, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells Cat No-IHBC010004 or equivalent make/L&T/Schnieder/Siemens.
S&F in repairs Busbar chamber in sheet enclosure including aluminium bus bar 200 Amps, TPN, 4 way, 415 V, AC, 50 Hz complete all as specified & directed. Make :- Havells Cat No-IHBC020004 or equivalent make/L&T/Schnieder/Siemens.
S&F in repairs Busbar chamber in sheet enclosure including aluminium bus bar 400 Amps, TPN, 4 way, 415 V, AC, 50 Hz complete all as specified & directed. Make-Havells Cat No-IHBC040004 or equivalent make/L&T/Schnieder/Siemens.
M&L for in repair for repairing/servicing the existing U/S Air Circuit Breaker of 800 Amp capacity L&T/Crompton make for proper functioning (tripping) on overload and earthfault by replacing the wornout parts, tightening all cable ends incuding replacing the unserviceable lugs etc, cleaning the dust by blower all as directed. Note:- (i) Wornout/Us parts of ACB will be paid & measured separately under respective item of schedule. (ii) The servicing of ACBs will be done only throgh authrised rep of OEM.
M&L in repairs the Lockable trip push button (LTPB) of 800 Amps Air circuit breaker. Make: Crompton / L&T.
All as per ser item No 218.00 above but shunt release (SR).
All as per ser item No. 218.00 above but Lockable trip push button kit.
All as per ser item No 218.00 above but Locking ACB in position (LAP).
All as per ser item No 218.00 above but Door interlock.
M&L for servicing to main electrical panel at sub stations by tightening the all loose connections of the cable ends & replacing the damaged/US/burnt aluminium lugs of required sizes, insulating/secure the weak insulated portin of cable ends inside the panel by taping with good quality of insulation tape, clean the dust by air blower all as specified and as directed.
Supply and laying of rubber mat of size 1 M x 2 M, 19 mm thick complete all as specified and directed.
Supply and installation acrylic first aid box in built hanging and locking arrangement with all necessary first aid material complete all as specified and directed.
Loading/unloading and transportation of LT transformer of any capacity from site to workshop and back to site after repair/ reconditioning including disconnecting and connecting of electric connection from HT/LT side complete all as directed.
M&L for making the HV/LV winding coils of same size using appropriate size of super enameled copper winding wire /strip of existing guage Nos of turns as in burnt out coils including compaction of coil, ovening insulating varnish again ovening to achieve the megger value as per IS and fixing the new coils in laminated core complete all as specified and directed.
M&L for dehyderation and filteration of transformer oil to achieve the dielectric strength of transformer oil 50 KV at 4mm gap of sphere complete all as specified and directed.
Opening the 1000 KVA transformer cover along with the conservator by removing the nut bolts then after removing the internal HT & LT connections by taking them out by removing studs, bushings taking out the core winding assembly out of the tank of the transformer, cleaning of core assembly by spraying forced TR oil, having ratio 11/0.433KV, draining & decanting of burnt transformer oil and clearing of sludge deposited in the tank with CTC for the transformer. Reconditioning of LT coil, Heating of core winding assembly in hot chamber for 48 hours and remove all the moisture present in it, removal of leakage of tank if any by carefully welding, refilling transformer oil to tank with filteration upto suitable die electric strength to tank, after putting the core-winding assembly into the tank, reassembling making the internal HT & LT connections by fixing the studs, bushing & fitting top cover by replacing cork sheet gasket along with conservator, testing the transformer in the workshop duly filled with oil, including transportation of transformer from site to workshop and vice a versa, all as directed for various capacities as under:- Note:- (i) U/S items required for repairs shall be measured and paid under relevant item of this schedule. (ii) Transformer oil with die electric strength not less than 40 KV either new or filtered shall be filled and shall be measured and paid separately under respective item.
M&L for EHV transformer Oil as per IS 335 of 1983 & IS 1866-2000 complete all as specified. Make: Power Oil/Savita /servo.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor typeConfirming to IP 43, CPRI approved, fabricated & assembled ,free standing, floor mounting, waterproof,dust and vermin proof cubical type, LT Panel of size not less than 1.5 m x 1.5 m x 0.45m above ground level fabricated from 3.15 mm thick (minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with bus bars made of aluminium duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shall be properly supported/mounted on epoxy insulators. All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Panel shall be manufactured suitable for housing and including taking down old one and the following (For Old DRDE street light Fedder):-
S&F in repair of GI Pipe 50 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturbed surfaces and sound condition complete all as specified and as directed.
All as per ser item No. 232.00 above but 80 mm.
All as per ser item No. 232.00 above but 100 mm.
S&F in repair earth continuity conductor GI strip 32x6mm size all as specified and directed.
S&F automatic power factor control relay of 12 stage operating Voltage - 230 V AC and current Input - 1A or 5 A, Steps-12 relay outputs, Supply Voltage-1 Ph 415 VAC (-40% to +20% ), Measurement Voltage : 3Ph 3 wire 415 VAC (-40% to +20%), Operating temperature : 0 to 70 ºC including testing, connecting, commissioning in such a way to avoid "controller hunting" complete as in repairs as specified and as directed having following features:- (a) Microcontroller logic for measurement. (b) User friendly operation. (c) Control mode : binary , unequal and user defined. (d) Multifunctional LCD display. (e) Single CT sensing for balanced loads. (f) Individual harmonic measurement upto 15th order. (g) Three CT sensing for unbalanced load. (h) Dual target Power Factor setting useful for utility and DG mode operation (j) Automatic synchronization (k) Separate 3 CT monitoring of healthiness of Capacitor within Panel. (l) Data logging. (m) RS 232 in front and RS 232/485 switchable connection at rear. (n) Step operation indication on LCD display plus LED which facilitates viewing from a distance. (o) Unique facility of including 'Fixed Capacitor Bank' for purpose of Transformer compensation. This can be set such that the controller doesn't ‘see' this capacitor. (p) Unique external temperature sensing by PT100. (q) Settable alarm facility - undervoltage,overvoltage and so on. (r) Settable auxiliary outputs - 2 Nos for Alarm, etc. (s) Dynamic Power Factor Controller (Transistorised) available in16 steps without PT100 facility available. (u) EMI/EMC type tested. Make: M/s EPCOS CAT No.BR6000,PFC CONTROLLER-BR-6000-R-12- Material Code - B44066R6012R 230N-1 or equivalent in Schnieder (Model- Varlogic N Power Factor Controller)/ABB ( RVC - 12)/Syntron
M/S SANTOSH CONSTRUCTION CO
M/S YOGANSH CONSTRUCTION CO.
M/S Amit Traders
M/s Sagar Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .