Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-Document fee not submitted |
Tender Value
₹31.0 L
EMD Value
₹61,920
Closing Date
7 Jul 2022, 4:00 pmClosed
Executive Engineer
Office of Executive Engineer Div-I JK SIDCO Haftchinar Sgr
Water Supply for WTP at NIFT OMPORA, Budgam
2022_SIDCO_176491_1
SIDCO/Constt/Div/1st/44
Open Tender
Civil Works - Water Works
Item Rate
30 days
Ompora
as per NIT
4 documents required · 4 mandatory
₹5,000
Executive Engineer Construction Div-I Haftchinar
₹61,920
21 Jul 2022
28 Jun 2022
8 Jul 2022
28 Jun 2022
7 Jul 2022
29 Jun 2022
Amount
Note: Contractor should Quote Rates with all taxes.
1620 20mm OD pipe
2025 25mm OD pipe
2532 32mm OD pipe
3240 40mm OD pipe
4050 50mm OD pipe
5063 63mm OD pipe
6375 75mm OD pipe
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) for multilayer composite pressure pipes
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc, not exceeding 80 mm dia.
Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standard and Weighing not less than 690 gms. A) 15 mm nominal bore.
Providing and fixing C.I double acting air valve of approved quality with bolts,nuts,rubber insertions etc.complete (The tail pieces,tapers etc if required will be paid separately): a) 50mm dia
PUMPS & EQUIPMENTS Supplying, installing, testing & commissioning vertical inline pumps with S.S. casing, S.S. impeller. mechanical seal, S.S. Shaft directly coupled to motor suitable for operation on 400/440 volts, 3 phase 2900 RPM. TEFC electronic motor mounted on a common MS channel baseplate/baseframe 150mm dia, pressure gauge, G.M. gauge, G.M. isolation cock and cement concrete foundation with plaster.Flexicon rubber expansion bellow shall be provided at discharge header of each Hydropneumatic pump. a) Control panel with pressure switch, electrical wiring, cabling from panel to pumps, level controller complete with all accessories. b) GI Heavy duty ( Class-C) suction and discharge header with butterfly valve at suction & discharge side of each pump & non return valve/Check valves at discharge of each pump. c) Set of accessories such as Pressure Switches, Connecting Power & Control Cabling etc. Hydropneumatic system as described above d) Hydropneumatic system for Flushing water supply system- with 1 No. Precharged vessel of minimum capacity of 500 Lts with interchangeable butyl rubber membrane connected to outlet header with necessary flanges, gaskets, isolation valves, nuts, bolts etc. complete.Variable Speed pumps.Location-Pump room for domestic water. e) Set of accessories such as Pressure Switches, Connecting Power & Control Cabling between all electrical equipments/control panel and Motor, etc. Domestic Water Pumps (to lift water from underground domestic water tank to all toilets Location - Near underground domestic water tank Capacity 5 LPS each Head 50 Mts. RPM 2900 No. of pumps 3 (2 working,1 standby)
NOTES FOR ALL PUMPS :- a) Level Controller with sufficient nos. of low / high level alarms, contacts with electrodes and control wiring for the automatic operation of all water supply pumps to achieve the functional requirement shall be provided. Control wiring between these pumps and water tanks shall be provided. Pumps must automatically start and stop at high water level and low level of water in underground domestic water tank. Dry running protection shall be provided for all the pumps.All water supply & sump pumps to operate automaticaly through level controller.Both the sump pumps shall start in case of extra high water level in sump. The job shall include all Butterfly/Check valves, Headers, Tees/Reducers/Nipples/Bends/Flanges, Rubber washers, Nuts Bolts and other accessories, etc. Contractor shall include all electrical/ mechanical items,electrical control panel as required to operate the system automatically/manually and also include in his rates level controller, electrical wiring, cables, between all connecting Elec./Mech. equipments, earthing main contol panal and connection to the various equipment, other accessories. Complete as required. Only main power supply with the earthing to the main control panel shall be provided by the owner through other agencies. All pumps & equipment shall operate automaticaly through level controllers. Control panel with pressure switch, electrical wiring, cabling from panel to pumps, level controller complete with all accessories.
M/S NISAR and CO.
M/S BCON
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .