Commandant ARC and MC
Commandant Assam Rifles constr and maint coy Laitkor Shillong
Maint and operation of 33 KV switchyard and maint of 11 KV HT line network at HQ DGAR, Laitkor
2022_ARMHA_691755_1
ENG/III-235/2022-23/07 dated 30 May 2022
Open Tender
Civil Works
Works
330 days
Laitkor
As per tender documents
2 documents required · 2 mandatory
₹500
Yes
Commandant ARC and MC
₹30,000
Yes
12 Jul 2022
30 May 2022
7 Jun 2022
30 May 2022
6 Jun 2022
30 May 2022
30 May 2022 - 6 Jun 2022
MAINTENANCE AND OPERATION OF 33 KV SWITCHYARD AND MAINT OF 11 KV HT LINE NETWORK Maint and operation of 33 KV/11 KV switchyard and all other equipment installed in switchyard and HT 11 KV switch gears (VCBs), HT 33/11 KV control panels with tripping mechanism/back up protection system in round the clock in three shifts (each shift of 08 Hours)per day by employing qualified or experienced 01 electrician and 01 helper/lineman in each shift including comprehensive maintenance of all HT/LT electrical equipment installed and HT/LT distribution network in Laitkor area by maintaining attendance register of staff employed all as specified and directed by Engr-in-charge. Note:- (a) Contractor shall quote his rates for Maint and operation of sub stations and all other HT eqpt installed at 33 KV switchyard and 11/0.0433 KV sub stations and electrical distribution network including provide protection equipments/tools. (b) The spares replaced under comprehensive maintenance shall be measured and paid seperately (c) Details of switch gears are as under :- (i) HT transformer 33/11 KV, step down of capacity 1.6 MVA and 3.15 MVA with allied equipment. (ii) HT transformer 1.6 MVA/3.15 MVA-03 Nos (iii) HT 11 KV VCBs = 13 Nos (iv) HT 33/11 KV control panel=02 Nos (v) OCB 33/11 KV=01 No (vi) All other HT equipments installed at 33 KV switchyard like lightning arrestors, VCBs , structure etc (vii) HT/LT overhead line/underground cables off sizes (viii) Substations 11/0.0433 KV with power distribution transformers etc with following items:- (ix) Power distribution 11/0.0433 KV - 13 Nos transformers with accessories (x) HT 11 KV panel board with accessories = 06 Nos (xi) LT panel boards installed at 33/11 KV Sub Stn -03 Nos (xii) Gen set with panel boards- 02 Nos (xiii) Contractor shall be responsible for any disciplinary case of staff employed (a) Contractor will produce character certificate issued by Police Station, Education/qualification certificate and Experience Certificate belonging minimum 02 years of the staff employed. (b) Necessary life insurance will be done as per prevailing rules for each tradesman employed through this job and the original policy documents will be produced for verification and record of the accepting officer immediately on after approval of trades man (c) All expenditure for necessary T&P, Dress, Safety Hardness Eqpt, communication, stationery, insurance of tradesmans etc as per specified in this job are deemed to be included in the quoted rate (d) All payments of labours will be done through Nationalized Banks and produced the bank statement to department before claiming bills (e) PENAL CHARGES :- If any of the activity mentioned above is not performed by the contractor than recovery as under will be affected :- (i) Absent on duty of attandent/trademan/Helper - Rs 1000 per person per shift (ii) Not cleaning (General Maint) of area - Rs 1500 per month (iii) Not providing T&P, protective clothing or safety equipment - Rs 5000 per month (iv) Non deployment of person as per perscribed experience and qualifications - Rs 4000 per person per month. (v) First Shift (0800 hrs to 1600 hrs)
(ii) Second shift (1600 hrs to 2400 hrs)
(iii) Third Shift (2400 hrs to 0800 hrs )
(B) Lineman/Helper (i) First Shift (0800 hrs to 1600 hrs)
(ii) Second Shift (1600 hrs to 2400 hrs)
(iii) Third Shift (2400 hrs to 0800 hrs )
COMPREHENSIVE MAINTENANCE Supply and making INDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 120 sqmm, 3 core, XLPE aluminum conductor cable of 11 KV grade as required and directed.
Supply and making OUTDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 120 sqmm, 3 core, XLPE aluminium conductor cable of 11 KV grade as required and directed.
Supply and fill power transformer oil with 50 KV di-electric strength of standard grade (Make-Servo/Savita or equivallent)
Supply and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings , ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc as required and directed.
Supplying and erection of 11 KV pin insulator complete with large steel head GI pin, nuts, washers etc as required
Supply and fixing tripping coil for HT VCB 11000 volts grade
S & F in replacement ammeter 96 x 96 mm size flush type of capacity 0 -150 Amp all as directed by Engr In Charge. Make : AE or equivalent
S & F KV meter of size 6 x 6 inches flush type all as directed by Engineer-in-Charge. Make : AE /L & T
Supply only first aid box as approved by St John Ambulance Brigade /Indian red cross conformiry to IS:2217-1963
Tayal Electric and Construction Co
S G Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .