Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹63,774
Closing Date
1 Feb 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(E) Hari Nagar
O/o Executive Engineer (E) Hari Nagar
Providing and Installation AC Unit under AE(E) Rajouri Garden, MTNL, New Delhi.
2021_MTNL_611816_1
EE(E-W)/MTNL/2020-21/47
Open Tender
Electrical Works
Works
30 days
Rajouri Garden
As per tender document
7 documents required · 7 mandatory
₹590
MTNL Delhi
₹63,774
9 Feb 2021
23 Jan 2021
2 Feb 2021
23 Jan 2021
1 Feb 2021
23 Jan 2021
90 days
Supplying/Installing/Testing & commissioning of 8.75 TR (nominal capacity) AC ductable units complete with outdoor unit,indoor unit,compressor operating on 3 phase ,415v + 10%,50Hz A.C. supply with all other associated accessories like various motors, evaporator coils, condensor coils, Expansion valve and drier kit complete in all respect and capable for performing cooling, air circulation and inbuilt motor protections etc.as reqd.
Supplying/Installing/Testing & commissioning of 8.75 TR (nominal capacity) AC ductable units complete with outdoor unit,indoor unit,compressor operating on 3 phase ,415v + 10%,50Hz A.C. supply with all other associated accessories like various motors, evaporator coils, condensor coils, Expansion valve and drier kit complete in all respect and capable for performing cooling, air circulation and inbuilt motor protections etc.as reqd.
Pdg. & installing following size copper pipe including cutting bending, jointing, brazing etc as reqd. for hot and liquid refrigerant line complete as reqd. a) 7/8"
Pressure testing with nitrogen pressure standing for at least 8 hr. vaccumzing & commissioning with refrigerant of following AC unit complete as reqd.
Supplying & laying of following sizes PVC sheated armoured copper conductor cable on the existing wall/ ceiling for power/ control cabling etc. as reqd.
b) 4 C x 6 Sq.mm
c) 4 C x 1.5 Sq.mm
d) Multicore unarmoured cable 8 Core
Fabricating & installing of 150mm wide cable tray tray made out with following M.S. perforated sheet material i/c nut bolt, screw, etc. as reqd. (a) With MS Pre-Coated Painted Sheet
Supplying & laying of 8 SWG. G.I. Wire on surface or on recess for loop earthing on the existing surface recess with main power cable etc. as reqd.
Pdg. & making MS structure work for cond/ duct supports/tray support/accoustic grid with following accessories i/c cutting, welding, painting of the same etc as reqd.
Providing & making drain arrangement for AC units with following pipe size 25 mm i/c Tee, union socket & elbow etc as reqd.
Pdg & fixing of copper pipe insulation (a)Pdg & fixing KINI FOAM insulation complete as reqd.
Providing and fixing of hanger supporting arrangement for ducted AC units etc as required
Pdg and fixing MS Stand for condensor units etc as reqd.
SITC of microprocessor based controller panel consisting of controlling the ac unit i/c inter connections of HP & LP cut out temp sensor & single phase preventor cut outs with display arrangement for two circuits in each package units with operating ON/OFF pushing arrangements etc complete as complete as reqd.
Supply and Installation of Supply air grille with VCD to be fixed in supply air duct/collar/path etc including accessories, consumables as required.
Supply and Installation of return/exhaust air grille without VCD to be fixed in return air duct/collar/path etc including accessories, consumables as required
Dismentalling of old package/ductable AC unit i/c its electrical /mechanical connection complete as reqd.
Providing & fixing metallic inter connections for each circuit for distribution of air from package unit to main branch for air distribution
Dismentling & Lifting of AC units (a)Dismentaling of drain pipes, copper piping, cabling, cable tray & shifting to desired location.required.
Lifting of A.C unit from ground floor to the desired place i e upto the site where the A C room is situated with the help of heavy labour & chain pully block complete as reqd.
Minor civil work /Wall opening for finishing the A.C fresh air package/ AC Units
S/Installation of following TR (nominal capacity) AC units complete with outdoor unit, indoor unit, compressor operating on single phase, 230 V ± 10%, 50 Hz A.C supply & all other associated acessories like various motors, coils complete in all respect as per scheule (a)1.5 TR 3* rated Split type
Supplying and fixing of G.I Sheet metal ducting i/c air distribution system, complete thickness gauge i/c nut bolts & gasket etc. as required. a)22 Gauge G.I sheet
b)24 Gauge G.I sheet
Providing and fixing thermal insulation with glasswool of 25mm thick having an density of 32 kg/m3 as per IS 8183 covered with tissue paper to prevent from dampness etc for further finished with aluminium/GI plain/perforated sheet of requiste size and thickess as per requirement for wall, ducting and RA boxing etc as required.
Providing and fixing insulation on ducting with 6mm thick closed cell fire retardant insulation
Providing and fixing fire retardant canvass cloth connection as required.
Dismantling/removing and renovation of existing GSS Ducting comprising of main ducting, branch ducts from AHU rooms to switching rooms including breaking of walls, opening etc complete as required for making addition and alteration for air conditioning system and reconnecting the ducting with main ducting etc as required.
Supply and fixing of following type damper made out with 18 gauge CRC sheet for supply / return air duct in main duct & branch duct as per site required i/c nut bolt, gasket etc. as required.a)Volume control damper for ductable / packaged unit / RA Path.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .