Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.0 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹13.2 L+₹12,427 (0.95%)Rejected-Finance | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹13.8 L+₹75,403 (5.77%)Rejected-Finance BATWARA SRINAGAR KASHMIR 190004 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹14.1 L+₹98,302 (7.52%)Rejected-Finance | L-4 | Rejected-Finance other than L-1 | |
| 5 | L-5₹14.1 L+₹1.1 L (8.25%)Rejected-Finance | L-5 | Rejected-Finance other than L-1 |
Tender Value
₹7.8 L
EMD Value
₹15,500
Closing Date
1 Apr 2023, 6:00 pmClosed
Lt Col Tapan Naurial, GE
Garrison Engineer 864 Enggr Wks Sec, PIN-913864,C/o 56 APO
Provn of wall paneling and flooring in bar room ( Bldg. No 85) under AGE BR II at BB Cantt Srinagar.
2023_MES_583265_1
864/WS-76/2022-23
Open Tender
Civil Works
Item Rate
180 days
B B Cantt.
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹15,500
Yes
2 May 2023
27 Feb 2023
3 Apr 2023
27 Feb 2023
1 Apr 2023
20 Mar 2023
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth, for foundation etc. not exceeding 10 sqm on plan and and getting out in hard/ dense soil, complete all as specified.
Rough excavation not exc 1.5 M deep and and getting out in hard/ dense soil complete all as specified.
Removing excavated material exceeding 1.5 KM and not exceeding 5 KM and depositing where directed at a level not exceeding 1.5M above the starting point, complete all as specified and directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed .
TMT mild steel bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed .
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beam; plinth beams; bases of columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed .
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and as directed .
RCC M-25 (design mix), using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed .
RCC M-25 (Design mix) using 20mm graded crushed stone aggregates chullah hoods, chajjas, water troughs, mangers, shelves, fins and similar articles with plain faces, complete all as specified.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to obtain rough finished flat surfaces of concrete, complete all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to obtain rough finished flat surfaces of concrete, complete all as specified and as directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions etc, square, ractangular or polygonal, to obtain rough finished flat surface of concrete complete all as specified and as directed.
Use and waste of form work to sides and sofits of floor or roof beams, beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc to obtain rough finished flat surface of concrete complete all as specified and as directed .
M&L for brick work with sub class ‘B’ bricks, old size, straight or curved on plan exceeding 6m mean radius , built in CM 1:6, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surface, finished even and smooth without using extra cement, complete all as specified and directed.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed .
M&L for preparation of new plastered surfaces of wall by using necessary filling compound of Altek/Birla white 1.5mm thick putty to obtain smooth/even surface using sand paper and applying two coats of oil emulsion distemper over a coat of primer, complete all as specified and directed
Rolled mild steel (structural) grade E 250 (Fe 410W quality -A) in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, leats etc., complete all as specified and as directed .
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed .
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed .
Hardcore of broken stone or boulders gauge not exceeding 63 mm , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed .
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed .
40 mm thick, Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in floor, including finishing the surfaces even and smooth without using extra cement, complete all as specified and as directed .
S&F 2nd class hard wood plain solid straight chowkats & frame wrought framed on the solid rounded or chamfered put together with glue pinned at joints complete all a specified and directed.
S&F 30mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all a specified and directed.
M & L for 75 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed. complete all as specified and directed
M & L for 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed. complete all as specified and directed
S&F for 100 mm long Aluminium anodised, barrel tower bolts of ex truded section and fixed complete all a specified and directed.
S&F for 150 mm long Aluminium anodised, barrel tower bolts of ex truded section and fixed complete all a specified and directed.
S&F for 100 mm long aluminum handles, fabricated type, anodized complete all a specified and directed.
S&F for 150 mm long aluminum handles, fabricated type, anodized complete all a specified and directed.
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete, all as specified.
Preparation of new wooden surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including one coat of pink primer complete all as specified.
Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with Ist class wooden beadingor tinned tacks or galvanised wire staple complete all as specified .
3mm thick Sheet glass, ordinary quality and glazing with oil putty in square or rectangle, area n exc 0.5 sqm in each pane, complete all as specified and as directed .
Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, use of necessary formwork as directed.
Demolition of brick or or stone/boulder masonry, built in cement mortor including all quions, arche, 0pillars etc but excluding ashlars facings, dressed stonework and precast concrere articles complete all as specified and directed
M&L for preparation of old surfaces of wooden or wooden based articles of any description, exc 10cm in width or girth and applying two coats of synthetic enamel paint , complete all as specified and directed.
French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old surfaces with two or more coats, complete all as specified and directed.
S&F wooden laminated flooring 1200mm x200mm and 6-8mm thick over and including 9mm thick plywood grade BWR ,type BB( 05 Nos ply) fix with nails to timber framework, PVC (foam) cushion, incl cornices/ beadings, door profile all per as instructions of manufacturer, complete all as specified and directed.
S&F 15mm thick 1st class softwood Australian wood panelling, fixed with tounged and grouded as wall panelling and including 9mm thick BWR plywood on the wall and finally finishing with french polish (two or more coats) and fixed, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, lamp holders, regulators, switch socket outlets, light fittings etc and making good disturbed surfaces of walls with cement mortar and white/colour wash to match with existing surfaces etc complete all as directed .
M&L for point wiring with single runs PVC insulated FRLS grade, 1100V grade cable with multistranded copper conductor of size 1.5 Sq. mm (Nominal area) (ISI Marked) drawn in and including PVC casing capping of suitable size with all fittings and accessories including PVC flush box/ Metal flush box/ sunken box of suitable size and drawing continuous earth wire of PVC insulated FRLS grade, unsheathed stranded copper conductor of size 1.5 Sqmm(ISI Marked) terminated the box for following type of point wiring including making good disturbed of wall completed all as directed .
For one light /fan, and bell point independent controlled by one, one way normal/modular Switch.
For one 3/5 pin socket outlet 5/6 Amps independent controlled by one, one way normal/modular Switch.
For one 3 pin socket outlet 5/6 Amps point on same board.
Description all as per Item No. 50 here-in-before but with FRLS grade, (ISI mark) PVC insulated and unsheathed two run multistranded copper conductor of size 2.5 Sqmm for one power point of 3 pin 15 Amps on independent board including FRLS grade (ISI mark), PVC insulated, unsheathed one run multi-stranded copper conductor of size 2.5 sqmm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
Switch piano flush button single pole one way 5/6 Amp, 240 Volts, complete all as specified and as directed .
S&F Modular switch one way 6 Amps, one module with modular plate and frame complete all as directed.
S&F Modular switch one way 16/20 Amps, one module with modular plate and frame complete all as directed.
Socket outlet 2 in 1, 3 Pin 5 Amps, 240 volts complete all as specified and as directed .
S&F Modular socket 6A, 2/3 pin combined, 2 module with modular plate and frame, complete all as specified and directed.
S&F Modular socket 6A and 16Amp, 2/3 pin combined, 2 module with modular plate and frame, complete all as specified and directed.
Switch socket combination, 2 in 1, 6 pin, 6 & 16 Amp flush type , complete all as specified and as directed .
M&L for ceiling rose, 3 terminals PVC/polycarbonate, isolated body complete all as specified and directed.
S & F LED light fitting fixture 20W, 6500K, 2000 lm decorative ultra slim with co extruded channel in thermally conductive material with plastic housing, heat sink, environmental friendly having power factor >0.95, surge protection 2.5KV energy efficient ready to use complete all as specified.
S&F ceiling fan complete with blades, down rods and accessories 230 volts, 1200 mm sweap with service value 6.00 BEE five star rates with brushless direct current motor, complete all as specified and directed.
M & L for sub main wiring with two runs of 6 Sqmm FRLS grade (ISI mark) PVC insulated, multi stranded, unsheathed copper conductor and one run of , PVC insulated ,multistranded FRLS grade (ISI mark) unsheathed copper conductor of size 6 Sqmm green colour as earth lead including PVC casing caping of suitable size complete all as specified and directed, including taking down old unservicable sub main wiring .
M & L for sub main wiring with two runs of 10 Sqmm FRLS grade (ISI mark) PVC insulated, multi stranded, unsheathed copper conductor and one run of , PVC insulated ,multistranded FRLS grade (ISI mark) unsheathed copper conductor of size 10 Sqmm green colour as earth lead including PVC casing caping of suitable size complete all as specified and directed, including taking down old unservicable sub main wiring .
S&F in repair/replacement of round/square surface/recess mounted LED downlighter panel with complete diffuser 9/12W complete all as specified directed.
Supply and fixing LED street light fitting 35/45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply & fix ventilating fan made out of high quality engineering plastic, resistant to colour change with anti static properties, 250mm sweep suitable to work on 230 Volts 50 Hz AC supply of Havells or equivalent of CG/Bajaj including connecting to ceiling rose all as required or directed.
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed .
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed .
Supply and fix MCB SPN, 240 Volts, 40 to 63 Amps, 10 kA rupturing capacity, 'C' series complete all as specified and directed .
Supply and fix Isolator DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed .
Supply and fix MCB SP, 240 Volt, 6-32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised steel earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Dismantling the outdoor and indoor unit of Split type air conditioner, 1.5 ton capacity after removing refrigerant pipe connection, electric wire connection including re-fixing in the same position after following repairs and complete servicing of machine complete all as directed by Engr-in-Charge: (a) Repairs of the suction and discharge tube and cooling coil and replacement of heat resistive thermocol, tube gas & liquid line. (b) De-scaling the complete refrigeration system with carbon tetra chloride solution, replacement of defective capillary tube, strainer and dryer of required size assembling the system, leakage test of the system by applying approximate head and vacuum up to (-) 75 Cm column of mercury. (c) Recharging of gas with suitable refrigerant as required and testing the cooling effect satisfactorily on full load after re-installation of air condition complete all as directed.
M/S Tajamul Ah Buchh
M/S MOHAMAD YOUSUF AKHOON AND SONS
M/S BASHIR AHMAD MIR
M/S MAHIR MUNEER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .