| 1 | L-1₹20.0 LAccepted-AOC HIMACHAL PRADESH HP | BILASPUR | HIMACHAL PRADESH | 174001 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹20.3 L+₹35,030.44 (1.75%)Rejected-Finance VILL GOPAL CHOWK DHANOTU PO MAHADEV TEHSIL SUNDERNAGAR DISTT MANDI H P | L-2 | Rejected-Finance Not found L-1 | |
| 3 | L-3₹20.8 L+₹84,812.66 (4.25%)Rejected-Finance | L-3 | Rejected-Finance Not found L-1 | |
| 4 | L-4₹20.8 L+₹87,668.76 (4.39%)Rejected-Finance | L-4 | Rejected-Finance Not found L-1 | |
| 5 | L-5₹21.1 L+₹1.1 L (5.68%)Rejected-Finance NOT AVAILABLE | L-5 | Rejected-Finance Not found L-1 |
Tender Value
₹33.7 L
EMD Value
₹58,019
Closing Date
4 Dec 2024, 5:00 pmClosed
Executive Engineer Jal Shakti Divn Haroli
Executive Engineer Jal Shakti Divn Haroli
C/O civil works, Laying, Jointing and testing of Rising Main, P/Laying, Jointing and testing of distribution system and Supply and errection of Pumping machinery providing internal electrical installation to pump house for T/Well at Sainsowal )
2024_HPIPH_95808_1
No. JSV/ Haroli/ TA/ tender/24- 5605-29 dt 25-11-24
Open Tender
Civil Works
Item Rate
180 days
T/well at Sainsowal
as per NIT
11 documents required · 11 mandatory
₹400
Yes
Executive Engineer Jal Shakti Divn Haroli
₹58,019
Yes
3 Feb 2025
26 Nov 2024
5 Dec 2024
26 Nov 2024
4 Dec 2024
26 Nov 2024
26 Nov 2024 - 4 Dec 2024
Amount
Excavation in foundation and trenches etc.(in pipes and pits) in all kinds of soils such as pick work, jumper work, blasting in soft / hard rock, chiselling / wedging out of rock / where blasting prohibited) saturated soil stacking the excavated soil as directed by the Engineer-in-charge clear from the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by the Engineer –in-charge in all leads and lifts.
Providing and laying cement concrete 1: 4: 8 (1Cement: 4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work foundation and plinth complete in all respect including all leads and lifts
Providing and laying cement concrete 1: 6: 12 (1Cement: 6 sand:12 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work foundation and plinth complete in all respect including all leads and lifts
Squarred rubble stone masonry coursed with hard stone of approved quality in foun. & plinth i/c racking out of joints in CM 1:6 complete in all respect including all leads and lifts
Providing and laying damp proof course 38 mm thick with cement concrete 1:2:4 (1cement:2 sand: 4 graded stone aggregate 12.50 mm nominal size and curing complete in all respect including all leads and lifts
Applying a coat of hot bitumen (mexphalt 80/100 equivalent) using 1.70 kg. per Sqm. on damp proof course after cleaning the surface with af loating piece of cloth lightly socked in Kerosene oil complete in all respect including all leads and lifts
Half brick masonary in common burnt clay building bricks in super structure above plinth level upto floor two level in cement mortar 1:4 (1 cement:4 sand) and curing complete in all respect including all leads and lifts
2nd class Brick work using common burnt clay building bricks in foundation and plinth in Cement mortar 1:4 (One cement: Four sand) complete in all respect including all leads and lifts
1st class Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:6 (1cement : 6 sand) complete in all respect including all leads and lifts
Brick work using common burnt clay building bricks (1st class) in super structure above plinth level upto floor two level in cement mortar 1:6 (1cement : 6 sand) complete in all respect including all leads and lifts
Providing wood work in frames of doors, windows and other frames wrought framed and fixed in position with second class deodar wood complete in all respect including all leads and lifts
Providing and fixing wood paneled glazed or paneled and glazed shutters for doors, windows and clear story 40mm thick windows including bright finished black enameled iron with necessary screws with second class deodar wood 40mm thick complete in all respect including all leads and lifts
Prov. & fixing wire gauge shutters using galvanized MS wire gauge of IS gauge designation 85 G. with wire of dia. 0.56 mm for doors,windows & clerestrey windows including bright finished black enameled iron hinges with necessary screws complete in all respect including all leads and lifts
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4meters and removal of the same for insitu reinforced concrete and plain in:-
(a) Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors upto 200mm in thickness complete in all respect including all leads and lifts
(b) Beams, cantilevers, girders & lintels, sides & soffits of beams, haunching, cantilevers,bressumers 1.00 mts. In depth in all heights from floorcomplete in all respect including all leads and lifts
Providing and laying cement concrete work 1:2:4 (1cement: 2 sand: 4 graded stone aggregate 20mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-
(a) Suspended floors, roofs, landings and shelves and their supports, balconies, beams ,griders bressumers and cantilevers upto all floor level complete in all respect including all leads and lifts
Cement concrete flooring 1:2:4(1cement:2sand:4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement (40mm thick) complete in all respect including all leads and lifts
Cement concrete flooring 1:2:4(1cement:2sand:4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement (50 mm thick) complete in all respect including all leads and lifts
20mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6(1cement:6sand) complete in all respect including all leads and lifts
15 mm thick cement plaster in single coat on rough side of brick / stone masonry for interior plastering up to floor two level including arrises, internal rounded angles chamfers and / or rounded angles not exceeding 80 mm in girth and finished even and smooth in C.M. 1:3 (one cement : three sand) complete in all respect including all leads and lifts
15 mm thick cement plaster in single coat on fair side of brick / stone masonry for interior plastering up to floor two level including arrises, internal rounded angles chamfers and / or rounded angles not exceeding 80 mm in girth and finished even and smooth in C.M. 1:3 (one cement : three sand) complete in all respect including all leads and lifts
6 mm cement plaster to ceiling in CM 1:3 (1Cement :3 Sand) complete in all respect including all leads and lifts
Pointing on brick work with cement Motor1:3 (1Cement:3Sand) with all leads and lift complete toi the entire satisfaction of Engineer-in-Charge.
Providing plinth protection 50 mm thick in cement concret 1:3:6 (1cement :3 sand: 6 graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth complete in all respect including all leads and lifts
Providing Tor steel reinforcement for RCC work including bending, binding & placing in position complete upto floor two level complete in all respect including all leads and lifts
Applying two coat of wood preservative on new wood based surface after and including preparing the surface by thoroughly cleaning dirt, dust and other foreign mattercomplete in all respect including all leads and lifts
Applying priming coat over new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil dirt grease and other foreign matter sand papering and knotting ready mixed paint brushing wood primer pink complete in all respect including all leads and lifts
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works with complete in all respect including all leads and lifts primer pink
Painting two coats(excluding priming coat) on new wood and wood based surface with ready mixed paint brushing the give and even shade including cleaning of all dirt dust and other foreign matter and sand papering and stopping with ready mixed paint other than white complete in all respect including all leads and lifts
White washing with lime on undecorated walls surface (two coats) to give an even shade including thoroughly brooming the surface dirt dust mortar dirt and other foreign matter complete in all respect including all leads and lifts
Finishing wall with water proofing cement paint of approved brand & manufacture & of required shade on undecorated wall surfaces ( two coats) to give an even shade after thotoughly brushing the surface to remove all dirt & remains of loose powdered materials complete in all respect including all leads and lifts
Providing and fixing M.S.fan clamp(Type-I of 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete in all respect including all leads and lifts
Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm dial meters bolts and nuts and wooden plug and embeding in cement mortar block 30x10x15cm (1:3:6(1cement:3sand:6 graded stone aggregate 20mm nominal size complete in all respect including all leads and lifts
Providing and fixing following anodized aluminium fittings of anodized transparent and shade with necessary screw etc. complete in all respect including all leads and lifts
Sliding door bolts 250x16mm.
M.S. tower bolts (Barrel type) leads and lifts. 200x10mm.
M.S. tower bolts (Barrel type) leads and lifts. 150x10mm.
M.S. handles 125mm dia
Providing and fixing of MS round bars in windows and ventilators.
Stone / Boulder filling under foors / behind retaining walls.
Steel work welded in built up section,trusses & frames work i/c cutting hoisting,fixing in position & applying a priming coat of red lead paint :- in grating,framed guard, bars, ladders, railng,bars, bracket & similar work. complete in all respect including all leads and lifts
Wiring for light/Fan point/Exhaust fan point/call bell point with 1.5 Sq.mm PVC insulated copper conductor cable in surface/recessed PVC conduct at required including carriage of all material within all leads and lifts. Group "C"
Wiring for light/power plug with 2 x 4 Sq.mm PVC insulated copper conductor or single core cable in surface/recessed steel conduit alongwith 1 No. 2.24 mm dia bare copper wire for loop earthing as required including carriage of materials within all leads and lifts.
Wiring for circuit wiring with 2 x 1.5 Sq.mm PVC insulated copper conductor single core cable in surface/recessed steel conduit as required including carriage of material within all leads and lifts.
Wiring for sub-main wiring with the following size of copper conductor single core cable in surface/recessed steel conduit as required including carriage of materials upto all leads and lifts. 2x6 Sq.mm
Supplying and fixing metal box of 180 x 100 x 60mm deep (Nominal size) on surface/recess with suitable size phonolic leminated sheet cover fixing 3 pim 15/16 amps socket tumber/piano type switch connections painting etc. including carriage of materials within all leads and lifts.
Supplying and fixing backellite batten/angle holder including connection as required.
Providing, installing, testing and commissioning of ceiling fan and regulator including wiring the rod of standard length (upto 30cm) with 1.5 Sqmm PVC insulated copper conductor single core cabe etc. as required sweep type. Cat. A
Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast snap on installers, suitable for 28 watt FTL (T5) complete with all accessories (including one No. T-5 Tube), connections, testing and commissioning etc. as required complete as per direction of the Engineer-in-Charge.of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recessed completed with tinned, copper busher neutral link, earth bar, detachable gland plate inter -connections, including painting, earthing etc. as required Bus bar 8 way.
Supplying and fixing 40/50/63 Amps rating 10KA 240 Volts "L" series miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts. Cat A
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recessed completed with tinned, copper busher neutral link, earth bar, detachable gland plate inter -connections, including painting, earthing etc. as required Bus bar 8 way.
Supplying and fixing 5 Amps to 32 Amps 10KVA breaking capacity 240 volts, C curves miniature circuit breaker of following poles in the existing MCB, DB complete with connections testing and commissioning etc. as required
Providing, installation, testing and commissioning of prewired flourscent tube fitting complete with ballast, starter and capactors but excluding flourscent tube rod, suitable to operate on 230 volts single phase A.C.supply directly on surface with copper wiring as required including carriage of materials within all leads and lifts tube fixture 1 x 36 watt Box type Category "A".
Earthing with G.I. pipe earth, pipe 4.5 length, 40 mm dia including accessories and providing masonry enclousres with cover plate having locking arrangement and watering pipe etc. ( but without charcal coke and salt) complete as required including carriage of materials within all leads and lifts.
Extra for using salt and charcoal for pipe earth electrode as required complete in all respect within all leads and lifts as per direction of the Engineer-in-charge..
Supplying and laying 6 SWG G.I. wire on surface /recess for loop earthing as required complete as per direction of the Engineer-in-charge.
Providing, fixing & testing Street Light Fixture with CFL of 36 watt, copper ballast, G.I. Pipe bracket, complete in all respects.
Laying, jointing and testing in trenches Galvanized mild steel flanged/butt welded pipes below mentioned dia and grade conforming to IS:1239-2004 (with latest amendments)The MS Flanges are to be provided for 5% of total joints as per table below conforming to IS:6392-1971 (latest upto date amendments) and welding of MS flanges with pipe as per IS: 816-1969 with electrodes as per IS:814-1991 including required number and size of MS nuts and bolts as per IS 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3.00mm in thickness as per IS:27121-1965. The welding of flanges to be done on both faces in three layers in each face to make the joints leak proof including all kind of specials such as bends of all degrees to be made from parent tube, short pieces, tail pieces all made from parent tube and to the entire satisfaction of the Engineer-in-Charge. The pipes end should be bevelled suitable for butt welding. the circumferencial butt welded joints (95% of the total joints) by electrical arc welding to following dia & class pipes, welding of pipes to be done in three layers to make joints leak proof and to achieve the minimum effective throat thickness of welded conforming to IS 816-1969 specifications, by using welding electrode of 2.5mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make conforming to IS 814-1991, at site of work complete in all respect and including DPT test for joints & manual/mechanical handling of pipes.The laying of Pipes conform to IS 5822 (with latest ammendentments upto date) including all kind of specials such as bends of all degrees to made from parent tube, short pieces, tail pieces all amde from parent tube within all leads and lifts (Earth work in trenches, MS flanges and butt welded joints to be measured and paid for seperately)
150 mm dia.(Medium grade) ( For Rising main)
Providing, Fixing & welding of M.S flanges conforming to table as specified below of BIS-6392-1971 ( latest with upto date ammendments ) welding of M.S flanges on ( Two layer on inner face and one layer on outer face of each flange) GMS pipe and bends on both ends ( The pipe to be measured & paid for separately ) The welding of flanges confirming to IS 816-1998 with electrodes as per IS 814-1997. Prov. & fixed with nuts, bolts of required size confirming to IS 1364 , providing and fixing 3mm (minimum) thick compressed asbestos fibre/synthetic rubber gasket conforming relevant BIS code IS 2712-1965 in trenches complete in all respect and including all kinds of leads and lifts and entire satisfaction of the Engineer-in-Charge 150 mm dia. Table-17 (5% of total Joints)
Pdg. Circumfrential butt welding joints to GMS pipe following dia with three layers on each end of welding using 3mm and 4mm dia electrodes after levelling the pipe ends according to relevent ISI specification and entire satisfaction of the Engineer-in-Charge i/c all leads and lifts. 150 mm dia
Providing Laying, jointing, testing and commissioning of HDPE pipe (High Density Polyethylene pipes) of following diameter class PE-80, grade PN 4.00 as per IS 4984-1995 PE-80 and jointing the pipes through butt fusion (heat fusion process) above 110 m diameter including all necessary fittings,bends, tees & reducers fabricated in accordance with IS 8360 & IS 8008 with latest ammendments & shall be provided as per site conditions (Earth work in trenches to be measured and paid separately) and jointing shall be completed in all respect including testing at site upto entire satisfaction of Engineer-in-charge.
HDPE pipe 160mm dia class PE-80, grade PN 4.00
Providing & Fixing CI Alfa Valves of following dia complete in all respect within all leads and lifts as per direction of the Engineer-in-charge
200 mm dia
Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan/Groundfos / confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge = (Q)17.53 LPS
Total Head = ( H) 164.58 Mts.
a) SWL in Tubewell = 54.87 Mtr. bgl.
c) R.L. point of discharge =271.60 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly=9.00 Mtrs.
e) Drawdown in Tubewell =12.20 Mtrs.
f) R.L of lowest point of pumpset installation = 123.93 mtrs.
g) Static Heads=147.67 mtrs.
Rising main.
Length 780 Mtrs.
Dia meter. 150 mm
Class GMS Pipe (MG)
Column Pipe.
Length 86.07 Mtr.
Dia 125 mm
Class GMS. (M)
Pumping hours = Hours
Altitude of installations above M.S.L. 450 Mtr.
Characteristic of water.
a) Temperature 40 Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well = Mtr.
Dia of housing pipe 300 mm
Length of housing pipe = meter
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing:- Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation : Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Driver Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Delivery size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947- P I & II with upto date amendments. i) Make : ii) Type : iii) Capacity : 200Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Panel/ Switch Board i) Drawing. ii) Layout Plan
OCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. i) Make : ii) Type : iii) Range 200 amp. iv) Capacity
ELR of recommended make L&T /Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR i) Make : ii) Type : iii) Range 200 amp. iv) Capacity
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )i) Make : ii) Type : iii) Range 0-500.
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ; 8084-1976 and IS : 11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. 3 phase indicators i) Make : ii) Type : iii) Rating
Three phase indicator lamps complete with toggle switches for individual motors as per IS 3452 (P- I&II ) with upto date amendments. 3 Phase indicators
Capacitor of BHEL / L&T make as per IS ; 2834-1968 with upto date amendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/ IEC make) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .Rate of capacitor will be approved by HPSEB. i) Make : ii) Type : iii) Range. 16 KVAR
Providing suitable starter of L&T/ Havell's /BHEL make as per IS :13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release, with or without 'initial oil filling as the case may be with Air Break. Type Star Delta with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Single Phase Preventor i) Make : ii) Type : iii) Range.
Providing and fixing double flanged Cast steel sluice valve of Leader / Kirloskar /karta/LP/RG Brand make for the delivery line of pump and capable of withstanding the normal seat pressure and as per API-600 (Cast steel ) with latest ammendments i) Make : ii) Type : iii) Make :- Cast steel for Column Pipe 125 mm dia Class ASA-150
Providing and fixing double flanged swing type cast steel Reflux valve of Leader/ Kirloskar/Kartar / LP/RG Brand make having Bye pass arrangement having Bye pass arrangement on the delivery line of the Pump and capable of 'withstanding normal Seat Pressure as per API-600 ASA-150 (Cast steel ) with latest ammendments PN-1.6 with latest ammendments i) Make : ii) Material : cast steel iii) Class ASA150 for R/main 150 mm dia.
Providing and fixing pressure gauge of Prega / Precision make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements. i) Make :
Supply of PVC jointless, flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havells/ Finolex make suitable for the pumpsets offered from OCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe, solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor. The type, size and make shall be subject to approval of HPSEB authorities. i) Make : Finolex/ Havells ii) Size 3x 35 mm2 iii). type- IV capacity V Core-3
Lowering of GMS Column pipefor assembly 125 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.58.02. The Column pipe should be extended upto 10 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. (The pipe shall be supplied by the Department free of cost from Divisional Store Samnal. Column Pipe 125 mm dia GMS pipe(M)
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay /Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts, cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply Side From meter of HPSEB to Bus Bar and Switch) i) Size 70mm2 ii) Make Finolex/Havells. iii) Type iv) Capacity v) Core 3.
Providing and fixing double loop earthing with G.I. flat suitable thickness electrode complete with material such as thimble, nuts and bolts, charcoal, salt, common as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) Beyond 50 HP to 75 HP GI Flat 25x3mm
PANKAJ GOVT. CONTRACTOR (BID ID -453802)
SATVEER SINGH (BID ID -453700)
KESAR SINGH (BID ID -453661)
Madan Lal Govt Contractor (BID ID -453784)
Rahul Sharma (BID ID -453866)
RAHUL SHARMA (BID ID -453865)
Om Parkash Govt Contrator (BID ID -453734)
Ashutosh bali (BID ID -452606)
VIKAS SHARMA (BID ID -453563)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .