Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 96 20 A CHUNNIGANJ KANPUR NAGAR | KANPUR NAGAR | UTTAR PRADESH | 208001 | Admitted-Fee/PreQual/Technical |
Cancellation of Tender
NIT need to be reviewed as per Latest PG Clause and Guidelines.
Change in NIT conditions/Specifications
cancelled_1.pdf
Tender Value
₹10.0 L
EMD Value
₹19,918
Closing Date
6 Feb 2026, 4:00 pmClosed
Executive Engineer (E)
Executive Engineer (E) M-33kV Division, 1st Floor ESS Kidwai Nagar West, Delhi-110023
Overhauling of Flange Mounted OLTC (On Load Tap Changer) along with RTCC Panel for 33/11kV PTR No.1 and PTR No.2 at ESS Raza Bazar, PTR No.1 at ESS Hanuman Road and PTR No.2 at ESS Baird Lane, Under M-33kV Division, New Delhi
2026_NDMC_285803_1
20/EE ( M-33kV )/2025-26
Open Tender
Electrical Works
60 days
NDMC
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹19,918
Yes
7 May 2026
29 Jan 2026
6 Feb 2026
29 Jan 2026
6 Feb 2026
29 Jan 2026
Overhauling of OLTC along with RTCC panel for smooth operation of Tap changer during voltage variation, Major work required in the OLTC Chamber: 1. Check and Overhaul of Motor drive for smooth operation without any noise from RTCC panel from Tap 1 to Tap 17 back and forward Operation at each Tap. 2. Replacement of Fuses. 3. Replace transition Resistor. 4. Gear Box Overhaul for proper coordination with motor shaft. Teeth and grove checked and replaced faulty. 5. Replace the Contact Pad. 6. Smooth operation for Tap changer from Local i.e. from OLTC Tap Changer. 7. Repairing of any damaged lead or contacts. Warranty 1 year
Major work required in RTCC Panel: 1. Operation of Controlling Switch automatically as well as manually from Panel. 2. Replace faulty Voltmeter with digital voltmeter. 3. Replace faulty digitalTap Position Indicator. 4. Three Phase Faulty Automatic Voltage Regulator (AVR) relay replaced. 5. AVR operation in forward and backward direction. Warranty 1 year
Associated Work: 1. Winding resistance test performed before and after Overhauling of OLTC. 2. Drain of OLTC Tank Oil and Top up with BDV 60kV after filtration. 3. Opening and closing of OLTC & RTCC Panel to complete the task successfully. 4. Painting of RTCC Panel. 5. Any other work related to OLTC & RTCC panel for smooth function. Warranty 1 year
Add GST @18%
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.27 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.77 MB
BOQ_378272.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid