| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.4 L+₹2.5 L (10.8%)Rejected-Finance FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹25.5 L+₹2.6 L (11.2%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹27.5 L+₹4.6 L (20.0%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹28.3 L+₹5.4 L (23.5%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹38.9 L
EMD Value
₹77,800
Closing Date
23 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8335 REPAIRS REPLACEMENT TO EXTERNAL SECURITY BUILDING LIGHT FITTINGS AND POLES IN THE AREA OF OTM ACCN 450 264 ORs OTM ACCN 53 ORs MD ACCN JCOs MD ACCN OFFRs MD ACCN NURSING COLLEGE AND NURSING MESS AT AFMC UNDER GE (CENRAL) PUNE
2022_MES_541681_1
8335 REPAIRS REPLACEMENT TO EXTERNAL SECURITY
Open Tender
Civil Works
Item Rate
210 days
GE (Central) Pune
As per Tender NIT
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹77,800
Yes
11 Oct 2022
28 Jul 2022
25 Aug 2022
28 Jul 2022
23 Aug 2022
10 Aug 2022
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable/ poles in soft/loose soil and getting out complete all as specified and directed.
All as per item No 1 above but exe 1.5 mtr but not exc 3.00 mtr depth.
Returning filling in incluiding spreading levelling watering and well ramming in layers n.exc 25 xm complete all as specified and diredcted.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in coping of poles including use and waste of form work fair finished surface of concrete all as directed.
M&L for PCC 1:4:8 type D-2 using 40mm grade stone aggregate as in foundation of poles/feeder piller box repair to floor/paths fencing etc including use and waste of necessary form work and fair finishing without using extra cement complete all as specified.
Dismantling of existing PCC coping (unreinforced) of any description and removal of debris to out of defence land all as directed by Engr-in-charge.
M & L for 150mm bore dia Reinforced concrete pipes Class NP-2 half round (each of 1 RM long for bottom and top) including levelling of ground before laying of pipe complete all as specified and directed. Note : Two Half Round bottom & top with to measured 100 RM as one RM.
Supply & lay in replacement 40mm bore dia all GI tubing ''light grade'' for protection of cable in ground/ fixing to existing pole with flat iron clamp 25x3 mm including nut bolts and washer etc complete :-
Supply, lay, test connect and commissioning underground cable LT 1100 volt grade heavy duty XLPE insulated with aluminum stranded conductor armoured complete laid in trenches/fixed to poles /drawn through pipes with suitable size cable glands criping type cable lugs etc including taking out old UG cable all as specified and directed of the following sizes :-
(a) 10 Sqmm 2 core
(b) 10 Sqmm 4 core
(c) 16 Sqmm 4 core
(d) 25 Sqmm 3.5 core
Disconnecting and taking down defective street light fittings of any type/capacity/ brand from steel/ RCC pole at 9 mtr height repairing and refixing and replacement of unserviceable parts like internal wiring, screws, nuts and bolts etc including daily checkeing and workability report to concerned JE E/M all as specified and directed by Engr-in-charge. Note :(i) Cost of minor items such as Screws nut bolts, wire of internal wiring will be included in quoted rates and No extra payment will be allowed on this account (ii) The street light fitting cover shall be cleaned properly as directed during repair works and rate of the same is deemed to be included in quoted rates. (iii) Necessary tools ladder and other testing equipments etc shall be arranged the contractor. (iv) GI Pipe brackets and clamps shall be measured and paid seperately under relevant items.
M&L in replacement of bracket made of GI pipe 40/50 mm dia light grade not less than 1.5 mtr fixed with 02 Nos of MS clamps fabricated out of MS flat of size 25x4mm including nut, bolts, washers and bent to shape etc complete.
Supply and fixing Integral LED Street Light Luminaire 45 Watt comprising of epoxy powder coated aluminium housing, enclosed with glass cover in frame suitable for 50/40 mm GI Pipe complete with accessories conforming to Cat Part No : ENXT P 45LWW CR PC DD of 'BAJAJ or equivalent all as specified Appx 'A' including taking down old existing fitting complete all as directed.
All as per item No.12 above but LED street light fitting 60 watt complete.Cat Part No : ENXT P 60LWH SY PC DD, of BAJAJ or of equivalent all as specified in Appx 'A' including taking down old exisitng fitting.
Supply and fixing Integral LED FLOOD Light Luminaire 150 Watt comprising of with ultra sleek, light weight and secondary optics, made pressure die-cast housing with IP-66 ingress protection and impact resistance of LK 07.4KV and 10 KV external surge protection incliding all aessories comprising of Cat Part No : BJFL 100W LED l of BAJAJ or of equivalent all as specified in list of makes Appendix 'A' including taking down old existing fitting all as directed.
Disconnecting and taking down defective Bollard light/ Post top lattern light fittings of any type/capacity/ brand from 1/1.5/2 mtr height repairing and refixing and replacement of unserviceable parts like internal wiring, screw nut blots etc including daily checkeing and workability report to concerned JE E/M all as specified and directed by Engr-in-charge. Note :(i) Cost of minor items such as Screws nut bolts & wire of internal wiring will be including in quoted rate. No extra payment will be allowed on this account. (ii) The light fitting cover shall be cleaned properly as directed during repair works and rate of the same is deemed to be included in quoted rates. (iii) Necessary tools ladder and other testing equipments etc shall be arranged the contractor.
Supply and fix new generation, Bollard light rectangular shape with opal acrylic diffuser, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution with high power LEDs as light source of cap 9 watts IP 65 protection and grouted in foundation sutable bolts, nuts and washers etc including electrical concetion with suitable copper wire, from junction box to light complete including taking down old fitting complete all as specifide and directed fittings. Make : cat part No BGBOS 600 9W LED WW of Make Bajaj or equivalent approved makes given in Appx 'A'
Supply and fix new generation, post top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution span aluminium landscape luminaire with high power LEDs as light source of cap 40 watts IP 65 protection as per cat part No LPTO-40-CDL-M of Make Crompton or equivalent in approved makes given in Appx 'A' complete including taking down old light fittings.
Supply and fix thermo plastic cable junction box of suitable size and suitable for outdoor installation embeedded in PCC coping including breaking existing PCC, removing junction box and making good after replacement of box complete including 4 way backlite terminals, MS holder fast/ flat, screw, nut bolts washers, 2 nos of long bends of PVC pipes for encomming & Outgoing cbles complete, all as directed.
Supply and fix FRP junction box light weight suitable for pole mounting including MCB SP 10 Amps single pole and necasry connector for loop in loop out cable connection and suitable size glands of size 250 x200x105mm complete including taking down FRP junction Box all as directed.
Supply & fix timer switch box fabricated out of 16SWG CRCA sheet with mounting arrangement duly power coated complete including taking down old timer switch box all as directed with consisting of following items :-
(a) Timer FM QT-1 01 No
(b) Power contactor 80 Amps - 01 No
(c) Connector 100 Amps rating 415 volts -03 Nos
(d) MCCB 4 pole 100 Amps 415 Volts-01 No
Supply and fixing PVC sheathed insulated wire round or flat in shape with copper conductor 3 core 2.5 sqmm working voltage 1100 Volt PVC cable, insulated passing through pole fixed to FRP junction box to street light fitting for 11/9 mtr long pole including suitable size of lugs for looping including taking down old wire complete all as specified and directed by Engineer-in-Charge
Supply and erect in true vertical position steel tubular swaged welded poles complete with MS base plate 6mm thick and size 300 x 300mm final taper, made out of MS tube type 410-SP-31, 9 mtr long including holes of required Nos and size MS pole cap bolts nuts, washer and screws Pole duly painted with red oxide primer and 2 coated of aluminium paint over exposed surface of poles and one coated of red oxide and 2 coat of bituminous paint for embedded portion of poles including dismantling old existing pole complete all as specified . Note : Excavation earth work & PCC shall be measured and paid separately under relevant items
Supply and fix in replacement IHP 1C W (24 x 7d) programmable time switch
Supply and fix in repair 4 Pole Power Contactors 80 Amps
Supply and fix in replacement of MCB SP 10 Amps,10 KA,'B' Series 230 Volts
Supply and fix in repair MCB TPN 63 Amps ,10 KA ,'B' Series,415
M&L for preparation of old painted surfaces of 9/11 Mtr long street light pole above ground level without removing any acessories and Repainting the pole with one coat of alumimium paint including clamps GI bracket etc and writing pole no with black paint all as specified and as required at site as directed.
M & L in Replacement earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and including GI wire 4 mm dia and GI Protection pipe 15 mm dia light grade for protection upto the extent of 7.5 Mtr as earthing lead by means of GI bolts, nuts and washers etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I incl RCC cover, M S angle iron frame funnel watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit including excavation and earth work in any type of soil and testing on completion etc complete Note : GI earthing wire and 15 mm dia GI protection pipe beyond 7.50 Mtr will be measured and paise separately.
Supply and fix earth continuity conductor or main earthing GI lead fixed to wall or pole on floor of size 4mm dia steel wire.
M & L in Replacement earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and including GI strip 32X6 mm and 40 mm dia GI pipe light grade for protection upto extent of 7.5 Mtr as earthing lead by means of GI bolts, nuts and washers etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Part-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit including excavation and earth work in any type of soil and testing on completion etc complete (NOTE:-GI earth strip and protection pipe 40mm beyond 7.5m will be measured and paid separately)
M&L in replacement for GI strip 32X6 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified.
M&L in replacement for Aluminium strip 25mm x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified.
Supply and fixing in replacement air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
Supply and fixing in replacement of test point terminal block made out of gun metal or Phosphorus bronze of size 75 x 75 x 25 mm dirlled and screwed including 03 Nos 8mm dia 25 mm long hexagonal head screw complete with all fixing accessires complete as specified and directed.
dismantling/ Removing of Old unserviceable/ unwanted brackets, insulator, nuts, bolts etc from pole all as specified and directed.
Chaulya Enterprises
Rama Electricals
Mahindra Electric Stores
Sparkh Electricals & Works
metro electrical services
PROLINK COMPUTERS
PURVA ELECTRICALS AND ENGINEERS
CHAITANYA WINDWELL
REKHA ELECTRICALS
Sunhari Electricals
M/S - SUJIT ELECTRICALS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .