Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-Finance | ₹1.2 Cr | L1 | Accepted-Finance Being L1 |
| 2 | L2₹1.3 Cr+₹10.5 L (8.65%)Rejected-Finance | ₹1.3 Cr+₹10.5 L (8.65%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹1.4 Cr+₹18.5 L (15.2%)Rejected-Finance | ₹1.4 Cr+₹18.5 L (15.2%) | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
10 Jan 2023, 4:00 pmClosed
Chief Engineer D and R
Office of Chief Engineer D and R, Kohima Nagaland
Construction of Dedicated 11KV Single Circuit Feeder from Keyake 5 MVA SS to Medical College
2023_DP_510_1
CEL/DR/D1/22/DW/HFW/1535
Open Tender
Electrical Works
Works
60 days
Kohima
Refer tender documents
3 documents required · 3 mandatory
₹5,000
Chief Engineer D and R
₹1.5 L
11 Jan 2023
6 Jan 2023
11 Jan 2023
6 Jan 2023
10 Jan 2023
6 Jan 2023
Amount
SUPPLY OF MATERIALS
GI Steel Tubular Pole SP-66
GI MS Channel 100x50x6mm for top Cross Arm - 2.2 M Long weighing 20.24 kg each (Per DP - 4Nos, SP - 1Nos)
GI Angle 50X50X6mm for Cross Arm Brackets - 2.5 M Long weighing 11.25Kg each. (Per DP - 4Nos, SP - 2Nos)
GI M.S Angle 50X50X6mm for DP Bracing and Gaurding - 5 M Long weighing 22.5Kg each. (Per DP - 4Nos, Guard bracket - 16nos)
11 kV Polymer Disc insulator 70 KN (Per DP - 6Nos, SP - 3Nos)
H/W fittings for Disc insulator (E&S) 70 KN, Tension type
11 KV polymer pin insulator (Per SP - 3Nos)
ASCR "Hare" conductor
Tension clamp for ACSR Hare
3 inch C.I earthing pipe each of 3.0 meters conforming to relevant ISS
G. I. wire , 8 SWG for guarding (5.71 Kg per Span)
G. I. wire , 6 SWG for earthing
HT stay set with 11 KV guy insulator
PG clamp, for ACSR Hare for conductor Jumpering
11kV Danger plate
GI nuts and bolts with GI washer (Assorted) including through boly 8" long of approriate dia.
Barbed wire
G.I Stay wire , 7/10 SWG
Pole clamp made of GI flat 50x6 mm size of various dia suitable SP 66.
Description of Work / Item(s)
Amount
GI Steel Tubular Pole SP-66
GI MS Channel 100x50x6mm for top Cross Arm - 2.2 M Long weighing 20.24 kg each (Per DP - 4Nos, SP - 1Nos)
GI Angle 50X50X6mm for Cross Arm Brackets - 2.5 M Long weighing 11.25Kg each. (Per DP - 4Nos, SP - 2Nos)
GI M.S Angle 50X50X6mm for DP Bracing and Gaurding - 5 M Long weighing 22.5Kg each. (Per DP - 4Nos, Guard bracket - 16nos)
11 kV Polymer Disc insulator 70 KN (Per DP - 6Nos, SP - 3Nos)
H/W fittings for Disc insulator (E&S) 70 KN, Tension type
11 KV polymer pin insulator (Per SP - 3Nos)
ASCR "Hare" conductor
Tension clamp for ACSR Hare
3 inch C.I earthing pipe each of 3.0 meters conforming to relevant ISS
G. I. wire , 8 SWG for guarding (5.71 Kg per Span)
G. I. wire , 6 SWG for earthing
HT stay set with 11 KV guy insulator
PG clamp, for ACSR Hare for conductor Jumpering
11kV Danger plate
GI nuts and bolts with GI washer (Assorted) including through boly 8" long of approriate dia.
Barbed wire
G.I Stay wire , 7/10 SWG
Pole clamp made of GI flat 50x6 mm size of various dia suitable SP 66.
Description of Work / Item(s)
Amount
ERECTION & CIVIL WORKS
Detailed Route Survey, investigation including peg marking, profiling/ alignment of route etc. complete as per Technical Specification
Excavation of Pole Pit & Grouting with PCC 1:3:6 including cost of cement, sand and agrregate (2.5ftx2.5ftx4ft per pole = 23.04Cft = 0.659 Cum)
Erection of Double Pole (DP) and Single Pole (SP) Structures - fixing of Cross Arm channels, angles, brackets, bracing, Stay sets, Insulators, hardware fitting and all required line accessories etc complete with following supplied items
GI Steel Tubular Pole SP-66
GI MS Channel 100x50x6mm for top Cross Arm - 2.2 M Long weighing 20.24 kg each (Per DP - 4Nos, SP - 1Nos)
GI Angle 50X50X6mm for Cross Arm Brackets - 2.5 M Long weighing 11.25Kg each. (Per DP - 4Nos, SP - 2Nos)
GI M.S Angle 50X50X6mm for DP Bracing and Gaurding - 5 M Long weighing 22.5Kg each. (Per DP - 4Nos, Guard bracket - 16nos)
11 kV Polymer Disc insulator 70 KN (Per DP - 6Nos, SP - 3Nos)
H/W fittings for Disc insulator (E&S) 70 KN, Tension type
11 KV polymer pin insulator (Per SP - 3Nos)
3 inch C.I earthing pipe each of 3.0 meters conforming to relevant ISS
G. I. wire , 8 SWG for guarding (5.71 Kg per Span)
G. I. wire , 6 SWG for earthing
HT stay set with 11 KV guy insulator
11kV Danger plate
GI nuts and bolts with GI washer (Assorted) including through boly 8" long of approriate dia.
Barbed wire
G.I Stay wire , 7/10 SWG
Pole clamp made of GI flat 50x6 mm size of various dia suitable for top, middle and bottom section of SP 66 Pole.
Stringing of line including laying out and sagging out of conductor, guarding, lacing and mid point jointing of conductor, installation of all necessary hardwares and accessories as per technical specification
ASCR "Hare" conductor (3.1 Km per 1 Ckm)
Tension clamp for ACSR Hare
PG clamp, for ACSR Hare for conductor Jumpering
Tree cutting along the line including trimming, looping, branching etc. as required to maintain statutory electrical clearance as per the direction of Engineer-in-charge
Description of Work / Item(s)
Amount
GST as applicable on all Supply items & F&I as per schedule 1 & 2.
GST as applicable on Erection & Civil works as per schedule 3.
Description of Work / Item(s)
Amount
TOTAL SCHEDULE NO. 1
Supply of Materials as per Price Schedule- 1
TOTAL SCHEDULE NO. 2
Local Transportation, Insurance and other Incidental Services as per Price Schedule- 2
TOTAL SCHEDULE NO. 3
Erection & Civil Works as per Price Schedule- 3
TOTAL SCHEDULE NO. 4
GST as applicable as per Price Schedule- 4
NATIONAL POWER SYSTEMS
M/s Mecavo Power Works
CARAVAN POWER AND CONSTRUCTIONS (I) PVT. LTD.
NATIONAL POWER SYSTEMS
NATIONAL POWER SYSTEMS
M/s Mecavo Power Works
NATIONAL POWER SYSTEMS
M/s Mecavo Power Works
NATIONAL POWER SYSTEMS
M/s Mecavo Power Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .