Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 CrAdmitted-Finance | ₹9.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.4 CrAdmitted-Finance AROMA MANSION LUM DONGSURAK UMPLING RYNJAH SHILLONG 793003 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793003 | ₹9.4 Cr | L2 | Admitted-Finance |
| 3 | L3₹9.8 CrAdmitted-Finance | ₹9.8 Cr | L3 | Admitted-Finance |
| 4 | L4₹10.1 CrAdmitted-Finance | ₹10.1 Cr | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non-Compliant with the required Financial and Construction Experience Criteria |
| Sl No | Description | Qty | Unit | ALOYSIUS ARENGH L2 | J B TEXTILES L3 | Bimal Kumar Agarwala L1 | Shri.Ziaul Hoque L4 |
|---|---|---|---|---|---|---|---|
| 1.00School | |||||||
| 1.01 | School1 | 1 | Nos | 4,69,81,284.5 ₹4.7 Cr | 4,91,84,278.24 ₹4.9 Cr | 4,81,63,124.1 ₹4.8 Cr | 5,10,27,267 ₹5.1 Cr |
| 1.02 | School2 | 1 | Nos | 4,70,40,352.47 ₹4.7 Cr | 4,91,90,240.64 ₹4.9 Cr | 4,53,96,014.57 ₹4.5 Cr | 4,96,42,298 ₹5.0 Cr |
Updated dates
Tender Value
Refer Docs
EMD Value
₹22.9 L
Closing Date
28 Oct 2025, 3:00 pmClosed
Director of School Education and Literacy, Megh
Director of School Education and Literacy, Meghalaya
Construction of additional facilities at Govt. Upper Primary School (Adokgiri and Chotcholja - North Garo Hills)
2025_EDADB_1812_1
SHCDM-II/CW-03/NCB/02
Open Tender
Civil Works
730 days
Adokgiri and Chotcholja - North Garo Hills
As per RFP
2 documents required · 2 mandatory
₹10,000
Yes
Director of School Education and literacy
₹22.9 L
Yes
Directorate of School Education and Literacy
13 Feb 2026
24 Sept 2025
28 Oct 2025
24 Sept 2025
28 Oct 2025
10 Oct 2025
25 Sept 2025 - 9 Oct 2025
8 Oct 2025
School
School1
School2
Package No: CW-06 (Lot-1)
Bill of Quantities for Adokgiri Govt. Upper Primary School
Bill of Quantities
BOQ item no
Earth work in excavation by manual/ mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. (For site preparation)
All kinds of soil
In ordinary rock
In hard rock (Blasting prohibited)
Earth work in excavation by manual means upto a depth of 2 m below the existing ground level for foundation, trenches of foundations, footings of columns/ walls, retaining wall, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.
All kinds of soil (ordinary soil/ hard soil/ dense soil)
In ordinary rock (soft rock/ medium rock/ hard shale)
In hard rock (soft rock/ medium rock/ hard shale) (Blasting prohibited)
Earth work in excavation by mechanical means upto a depth of 2 m below the existing ground level for foundation, trenches of foundations, footings of columns/ walls, retaining wall, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.
All kinds of soil (ordinary soil/ hard soil/ dense soil)
In ordinary rock (soft rock/ medium rock/ hard shale)
In hard rock (soft rock/ medium rock/ hard shale) (Blasting prohibited)
Same as Items 3.0 & 4.0 above but for each additional 1 m depth or part thereof beyond the initial depth of 2 m
All kinds of soil
In ordinary rock
In hard rock (Blasting prohibited)
Disposal of surplus earth/ unserviceable material from the work site including loading and unloading complete as directed for a total of 15 km (i.e. 10 km beyond the initial lead of 5 km)
Excavated earth
Excavated rock
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered).
Upto a depth of 1.50 m
Above 1.50 m upto 3.00 m depth
Earthwork in filling (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
With available excavated earth
Extra over Item for additional lift of 1.5m or part thereof for all types of soils
Sand filling in plinth in layers not exceeding 150mm in depth including breaking of clods, consolidating by watering and ramming complete as directed (maximum depth 45 cm)
SUB TOTAL
Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by the Engineer-in-charge.
Shuttering for sides of plain cement concrete work in blinding concrete, plinth protection, copings, sills etc.
Foundations, footings, bases of columns, raft, grade slab etc. for mass concrete (using steel)
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (using steel)
Suspended floors, roofs, landings, balconies and access platforms, shelves (using steel)
Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel)
Columns, Pillars, Piers, Abutments, Posts and Struts (using steel)
Stairs/ spiral staircase, (excluding landings) (using timber)
Edges of slabs and breaks in floors and walls (using timber)
Weather shade, Chajjas, corbels etc., including edges (using timber)
Extra for additional height in centering, shuttering wherever required with adequate bracing, propping etc., including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)
Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) (For total height of 6.60 m (i.e. 3.10m over and above the standard height of 3.5 m)
SUB TOTAL
Plain cement concrete works in foundation bed for footing steps, walls, brick works etc. below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
1 :3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls etc. and all works above plinth level such as pilasters, columns, pillars, posts, struts, buttresses, parapets, coping, plain window sills, fillets, sunken floor etc.,, up to first floor level, excluding the cost of centering, shuttering and finishing
1 :3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) (For cement concrete screed below floors)
1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size)
SUB TOTAL
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
All works up to plinth level
All works above plinth level up to first floor level
Extra for providing richer mixes:
Providing M-30 grade concrete
Extra over item No 13.2 & 14.0 above for each subsequent floor or part thereof above the first floor level.
Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required)
Thermo-Mechanically Treated bars
Extra over item 16.0 above for each subsequent floor or part thereof above first floor level.
Providing and fixing parallel threaded couplers conforming to ls code on "Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement-Specification", to reinforcement bars including threading, enlargement at connection by forging, protecting the prepared reinforcement bars and related operations as required to complete the works as per direction of Engineer in-Charge
Coupler for 16 mm diameter reinforcement bar
Coupler for 20 mm diameter reinforcement bar
Coupler for 25 mm diameter reinforcement bar
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections.
Providing & mixing approved pure acrylic based polymer modified waterproofing compound in concrete work of approved brand and quality, mixed with cement in required proportions as per manufacturer's guidelines, specifications and as directed by the Engineer-in-Charge. The product shall comply with IS: 9103 and IS: 2645. The product must be free of chlorides and shall comply with ASTM C494 Type A & D.
Note : 1) Reinforced cement concrete shall be paid separately under relevant item
SUB TOTAL
Brick work with common burnt clay modular lst class bricks in foundation and in plinth:
In Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work in cement mortar with first class brick in superstructure above plinth level up to first floor level in all shapes and sizes:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Extra over item No 22.0 above for each subsequent floor or part thereof above the first floor level.
Half brick masonry with common burnt clay (non modular) first class bricks in superstructure above plinth level up to first floor level
Cement mortar 1:4 (1 cement :4 coarse sand)
Extra over item No 25.1 above for each subsequent floor or part thereof above the first floor level.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
SUB TOTAL
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with:
Cement mortar 1 :6 (1 cement: 6 coarse sand)
Random rubble masonry with hard stone in superstructure above plinth level and up to first floor level, including leveling up with cement concrete 1 :6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) at window sill, ceiling level and the like
Cement mortar 1 :6 (1 cement: 6 coarse sand)
SUB TOTAL
Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre-polished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade, area of slab upto 0.50 sqm (For laboratory counter tops)
Providing edge moulding to 18 mm thick marble stone counters, Vanities, etc.„ including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in Charge.
Granite work
Extra for fixing marble/ granite stone, over and above corresponding basic item, in facia and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing Of cut edges etc. complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to lS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours and shades of any size as approved by Engineer-in-Charge, in walls, skirting, risers of steps and dados, over 12 mm thick bed Of cement mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Normal range
Providing polished Vitrified wall tiles of approved quality, size, shape and thickness not less than 8 mm on walls and skirting over cement mortar bed 10 mm thick in prop.1:3 (1 cement: 3 coarse sand) including cutting where necessary finished with flush pointing with adhesive or white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed.
Normal range
Providing and fixing 750 mm high, 50 mm deep and 18 mm thick stone slab table rubbed, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
SUB TOTAL
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length.
With Teak wood/ Sissu wood.
Providing and fixing ISI marked flush door shutters conforming to lS:2202 (Part I) non-decorative type, core of block board construction with frame of lst class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including lSl marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with wooden battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) :
Rectangular or square
Extra if louvers are provided (not exceeding 0.2 sqm) in all wooden frames and shutters (overall area of the door shutter to be measured)
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:
With Teak wood/ Sissu wood - 50 x 20 mm
Providing and fixing 18 mm thick,150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, lS:3087 marked, including top cover of 6 mm commercial ply wood conforming to lS:303 BWR grade, nickel plated M.S. pipe 20 mm dia (heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100x40x40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete.
Extra for using veneered particle board conforming to lS:3097 Grade I, in item of pelmet 18 mm thick 150 mm wide.
Particle board with decorative veneering on both sides
Providing and fixing teak wood lipping of size 25x3 mm in pelmet.
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete:
25 mm dia
Providing & fixing decorative high pressure laminated sheet of plain/ wood grain in gloss/ matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to lS : 2046 Type S, including cost of adhesive of approved quality.
1.5 mm thick
SUB TOTAL
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in positio
per kg
Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia. steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
ln stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
Rate Only
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered).
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia. Wire and 1.4 mm aperture on both sides
Providing and fixing M.S.fan clamp type I or II of 16 mm dia. M.S.bar, bent to shape with hooked ends in RCC slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars, etc. including priming coat with approved steel primer all complete.
Fixed to openings/ wooden frames with rawl plugs screws etc.
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/ honey-comb area of concrete/ masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-charge
Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non-shrink compound in concrete/ BCC work
SUB TOTAL
Providing and fixing bolts including nuts and washers complete.
FLOORING
General Note for Flooring :
All Stone flooring should be adequately protected with plastic sheets, POP layer till final polishing & handing over, without any extra payment.
Providing and laying damp proof course with cement concrete in prop 1 :11/2:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
40 mm thick
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing soling with stone, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
Stone Soling, 150 mm
Filling sunken floor with broken brick bats/ stone aggregates and sand including compacting and supplying of materials complete as specified and directed for all levels.
Brick bats
Providing and laying damp proof course with cement concrete in prop 1 :11/2:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 :4 (1 cement: 4 coarse sand).
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade Of the slabs, including rubbing and polishing complete
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre.
Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to lS:15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600 x 600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg Of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling, grouting and finishing complete as per direction of Engineer-in-charge
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, etc. all complete as specified and as directed by the Engineer-in-Charge. (In strips or any other approved pattern for Ramp areas)
Providing Vitrified Anti-skid Tiles of approved quality size, shape not less than 8 mm on floor, skirting over a cement mortar bed 15 mm thick of 1:3 (1 cement: 3 coarse sand) complete at all level as specified and directed.
SUB TOTAL
Normal range (For toilets)
PLASTERING
Providing and applying 15 mm thick cement plaster on rough side of single or half brick wall of mix: in cement mortar 1:6 (1 cement : 6 coarse sand) to interior masonry/ concrete wall surfaces
Providing and applying 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement: 6 fine sand).
Providing and applying 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self-curing mortar of approved make as per the direction of Engineer-in-Charge.
per bag of 50 kg cement
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 in or part thereof.
Providing and applying 12 mm of cement plaster finished with a floating coat of neat cement of in cement mortar 1:4 (1 cement : 4 coarse sand) to interior masonry/ concrete wall surfaces
SUB TOTAL
Providing & fixing G.I. Hexagonal chicken wire mesh of 19 size of aperture (12mm x 20 gauge) confirming to IS : 3150 at the junction of dissimilar surfaces of brick / block masonry wall and RCC column / beams and the like including necessary "U" nails / screws with cleats for fixing, overlapping, necessary scaffolding etc. complete all as per specification and as directed by the Engineer-in-charge for all heights and all locations.
PAINTING, OILING, POLISHING, VARNISHING WORKS
Providing and applying Plaster of Paris put
ty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
White washing with lime to give an even shade for new work (three or more coats)
Finishing walls with Acrylic smooth exterior paint of required shade, including scaffolding:
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat Of exterior primer applied @ 2,20 kg/10 sqm)
Wall painting with acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
New work (two coats)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
On steel work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
New work (two or more coats)
SUB TOTAL
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron/ steel works
Rate only
FENCING, SITE DEVELOPMENT & MISCELLANEOUS WORKS
Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately).
75 mm thick back filling for pitching including supplying of required materials and consolidation etc. complete with:
Moorum/Any kind of soil
Providing and laying tactile tiles (for vision impaired persons as per standards) of size 300 x 300 x 9.8mm having water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement: 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and placing in position, 100 mm thick factory made machine batched & machine mixed precast RCC rectangular covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia. TMT bars of Fe 500 grade @ maximum 100 mm c/c on both ways, neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick,100 mm wide MS sheet duly painted over priming coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos.12 mm dia. bar for hooks etc. including cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 in above ground level and removal of rubbish up to a distance of 50 in outside the periphery of the area cleared.
Felling trees of the girth (measured at a height of 1 in above ground level), including cutting Of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
Beyond 30 cm girth up to and including 60 cm girth
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 in and lift up to 1.5 m in all kinds of soil
Chlorpyriphos emulsifiable concentrate of 20% (or approved equivalent)
litre
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 ltr/ Rm including drilling and plugging holes etc.:
litre
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
litre
Treatment of soil under floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor:
Treatment of masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement: 2 coarse sand) to the full depth of the hole:
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia. holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing
Rectangular shape of 453 x 357mm
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia. PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910, on 12 mm dia. steel bar conforming to IS:1786, having minimum cross section as 23x25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) complete as per design.
Supplying and fixing C.I. cover without frame for manholes:
560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
SUB TOTAL
HD-20; Circular shape 560 mm internal diameter
PILING WORK
Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost Of steel reinforcement but including the cost of shoe and the length Of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top Of shoe to the bottom Of pile cap):
450 mm diameter piles
Vertical load testing of piles in accordance with ls:2911 (Part lv) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction Of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in- charge
SUB TOTAL
Initial test ITest Load 2.5 times the sate capacity
ALUMINIUM WORK
For fixed portion; using anodized aluminium (anodized transparent or dyed to required shade according to ls:1868, minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately); using anodized aluminium (anodized transparent or dyed to required shade according to ls:1868, minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door. window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge:
With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections.
For fixed portion
For shutters of doors, windows & ventilators
SUB TOTAL
Providing and fixing anodized aluminium (anodized transparent or dyed to required shade according to lS:1868. Minimum anodic coating of grade AC 15) sub frame work tor windows and ventilators with extruded built up standard tubular sections of approved make conforming to lS:733 and lS:1285, fixed with dash fastener of required diameter and size.
WATER PROOFING
Note: All the waterproofing treatment shall be executed through a recognized water- proofing agency approved by the Engineer-in-charge. A written guarantee on non-judicial stamp paper shall be submitted by the Contractor for a minimum period of ten years from the certified date of completion for the satisfactory performance of the entire water-proofing system.
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for underground structures as directed by Engineer-in-charge and consisting of :
(i) 1st layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound conforming to lS:2645 in the recommended proportion over the levelling course (levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 0.008 cum/sqm thoroughly embedded in the 2nd layer.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to ls:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement: 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge:
Providing and placing in position suitable PVC water stops conforming to lS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:
Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying:
1st layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours.
2nd layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to lS:2645 and approved by Engineer-in-charge over the PCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/ brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to lS:2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1 :5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to lS:2645 and approved by the Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs.
(c) After two days of proper curing, applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to lS:2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1 :4 (1 cement: 4 coarse sand) admixed with water proofing compound conforming to lS:2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm squares, 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.
All above operations to be done in order and as directed and specified by the Engineer-in-Charge.
With average thickness of 120 mm and minimum thickness of 65 mm.
Grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and making khurras 450 x 450 mm with average minimum thickness of 50 mm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 ltr/10 sqm. One coat of self priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of u
ndiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry: 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry: 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
SUB TOTAL
For vertical surface two coats @ 0.70 kg/sqm
Making soak pit 2.5 in diameter 3,0 metre deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diamcter,1.8 in long complete as per standard design
DOOR AND WINDOW FITTINGS
Hinges
Providing and fixing lS:12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete:
Providing and fixing oxidized M.S. double acting spring hinges with necessary screws etc. complete.
Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge
Handles
Providing and fixing aluminium handles, lSl marked, anodized (anodic coating not less than grade AC 10 as per lS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing bright/ matt finished stainless steel handles of approved quality & make with necessary screws etc. all complete
125 mm (For entrance glass door)
Providing and fixing bright finished brass 100 mm mortise latch and lock, lsl marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per ls:1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3 mm thick & 2100 mm long with SS screws etc. complete as per direction of Engineer-in-Charge
Anodized (AC 15) aluminium tubular handle bar (for glass door)
Locks & latches
Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing bright finished brass 100 mm mortise latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing Brass 100 mm mortise latch and lock with 6 levers without pair of handles (best make of approved quality) tor aluminium doors including necessary cutting and making good etc. complete
Providing and fixing 100 mm aluminium baby latch, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.
Providing and fixing aluminium sliding door bolts, lSI marked anodized (anodic coating not less than grade AC 10 as per ls:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
Door closers, stoppers & tower bolts
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with lSI, lS:3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISl marked, anodized (anodic coating not less than grade AC 10 as per lS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper, lSl marked, anodized (anodic coating not less than grade AC 10 as per ls:1868) transparent or dyed to required colour and shade, with necessary screws etc. complete
Twin rubber stopper
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to lS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 kg, for doors, including cost Of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness (For glass door)
Window fittings
Providing and fixing aluminium casement stays, lSl marked, anodized (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete.
Signages (Door mounted)
SUB TOTAL
Providing & fixing brush finished 16 SWG stainless steel stain finished (SS 304 Grade) signages of specified size, approved make and quality at all indicated locations as per approved shop drawings and as directed by the Engineer-in-charge .
Signages of 200 mm x 200mm size and make and mounted on door / wall, fixed with SS screws including all accessories etc. complete.
SUB TOTAL
HORTICULTURE AND LANDSCAPING
Provisional sum for carrying out the horticulture and plantations including all accessories and allied civil & electromechanical work required for the successful completion of the work as per drawings, technical specifications and as directed by the Engineer-in-charge
Sub-Total of Civil cost: A
Electrical Works:
Providing, laying, connection, testing & commissioning of the following sizes of 1100V grade Copper conductor armoured underground cable & overall PVC sheathed cable as per ISI code in trenches including the cost of digging of trenches, sand cushioning with laying etc. and refilling the same in layers or by supporting them in walls and all other accessories as required.
With 4 core 16 sqmm
With 4 core 10 sqmm
With 4 core 6 sqmm
With 3 core 10 sqmm
With 3 core 4 sqmm
With 3.5 core 50 sqmm
New Service Connection Charges to be paid to MeECL
Part B: Building Electrification
Wiring in looping system with copper PVC cable 250/440 volt grade of size 1.5 sqmm of approved quality using PVC casing capping incluiding 5 amperes switch Indian best quality ceiling rose etc. capable to a highest point
Long point wiring upto 10mts (i) With copper conductor
Medium Point wiring up to 6 mts (i)With copper conductor
Short Point Wiring up to 3 mts (i)With copper conductor
Wiring as in item No.6 above to a Ceiling/ Exhaust Fan Point
Short Point Wiring up to 3 mts (i)With copper conductor
Long point wiring upto 10mts (i) With copper conductor
Short Point Wiring up to 3 mts (i)With copper conductor
Wiring as in item No.6 complete to a light plug point when fixed else where.
Long point wiring upto 10mts (i) With copper conductor
Wiring to a power plug as in item No.6 above with 2X4mm 2 including supplying & Fitting of 15Amp 5 in 1 SS combined with continuous earth wire to a power point complete
Wiring to a power plug as in item No.6 above with 2X4mm 2 including supplying & Fitting of 15Amp 5 in 2 SS combined with continuous earth wire to a power point complete
Drawing of Main and Sub-main line with DGSD approved VIR or PVC 250/440 Volt grade in PVC casing capping complete with all accessories.
With 2×2.5mm2 Copper Conductor
With 2X4 mm2 Copper Conductor
With 2X6 mm2 Copper Conductor
Drawing 3 phase Main Line 4 wire with DGSD approved VIR PVC cable 660 V grade in casing capping with all necessary accessories
With 4 X 6 sq. mm copper conductor
With 4 X 10 sq. mm copper conductor
Supplying & fixing of Load Kontaket Miniature Circuit Breakers (MCBs)
6 - 32 Amp. SP MCB
40 - 63 Amp. SPN MCB
40 - 63 Amp. TPN MCB
Supplying, fitting & fixing of Load Kontaket Miniature circuit breakers Double Pole (Isolator)
32 Amp DP Isolator
40 Amp DP Isolator
63 Amp DP Isolator
100 Amp DP Isolator
125 Amp DP Isolator
Supplying, fitting and fixing of Residual-current circuit Breaker with Overcurrent protection RCBOs assembled for AC applications upto 63A.
Supplying, fitting and fixing of Moulded case circuit Breaker of the following capacity
4 Poles 16 -63 Amp Capacity
4 Poles 80 -100 Amp Capacity
Supplying, fitting and fixing of SPN / TPN MCB Metal enclosure MCB Distribution box
Supplying, fitting and fixing of SPN / TPN MCB Metal Enclosure Distribution Board
12 Way (8+36) Modules
Supplying, fitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie Lamiated sheet cover in the front including painting etc. as required.
75mm x 75mm x 60mm deep
100mm x 100mm x 60mm deep
150mm x 150mm x 60mm deep
250mm x 300mm x 100mm deep
Supplying fitting and fixing Batten LED light fitting complete with all accessories for surface or pendant mounting as per Department direction and approved
Supplying fitting and fixing LED fittings of different wattage,surface or recess or pole mounting, direct or indirect luminair square or round shape also suitable for porch lighting etc.fitted with mirror reflect or complete with all neccessary accessories.
18 watt Round
10 watt Bulk head
Supplying fitting and fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED lamp.(a) with 25cm dia glass shade complete.
Supplying and fitting of ceiling fan AC operated type 220/250 volt. Complete with 3Nos of blades down rod canopy hanging shackle & regulator complete with 30mm length down rod supplied with the fan by the dealer but the extra length will be charged @ Rs25.00/ mtr
AC ceiling Fan '1400' mm sweeps
Supplying , installation testing & commissioning of self contained emergency light unit 1x3 watt double sided for wall / ceilling mounting with suspension / mounting kit, inbuilt standby battery( for 2hours backup)and battery charger etc.
1 x 3 W double sided
Supplying fitting and fixing of exhaust fan double bearing self lubricating type single phase 50Hz 250V AC operated complete with supporting frame, fan blades, nuts and bolts, fan regulator, capacitor, adjustable type lever and other petty accessories as required
Medium Duty Exhaust Fan
Supplying, fixing, connecting, testing and commissioning of calling Bell/ Bell indicator type suitable for 230 V as well as battery operated complete with all necessary accessories
Gong Bell
Ding dong Bell
Remote Bell
Supplying fitting & fixing earthing with GI earth plate 600 × 600mm × 6mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe etc with charcoal, salt set complete as required
GI Earth Plate Electrode
Supplying and laying of 15mm × 5mm GI/Copper Strip at 0.50mts, below ground.
With 25mm×5mm copper strip
with 25mmx6mm GI strip
with 25mmx3mm GI strip
Supplying, fitting and fixing of copper/Alluminium lightning Arrestor with 5no.s finger at the top & copper base plate at the bottom complete.
With 3 ft high road
Providing, fixing, connecting and testing of lightning conductor (AirTermination) made of 32 mm dia GI Pipe 2 meters long with 150X180 mm dia galvanized base plate complete with all necessary accessories
Supplying fitting and fixing of LAN (Computer Cables)
CAT - 6 unarmoured UTP
SITC of Bullet camera as per site condition complete with all accessories
SITC of External light of 70 watt LED fixture with 7 meter GI pole of single arm, including foundation, foundation bolts, nuts, MCB, internal wiring with 3R x 2.5 sqmm, conduiting etc. complete as per site requirement
Aesthetically designed led post top with aluminium enclosure, powered with high power leds as light source and die casted heat sink exhibits classic victorian look with symmetrical light distribution and excellent heat dissipation for long life.
70W suitable for pole dia 76mm
Part-C: UPS
Supply, Installation, Testing and Commissioning of following rated high performance IGBT based fully microprocessor controlled (Single phase Input & Single phase Ou
tput) online UPS system suitable for input and output parameters as per specifications. The UPS shall have Separate Galvanic Isolation Transformer Inbuilt/External K13 Copper Wound (After Static Switch) transformer. The UPS shall be provided in powder coated fan cooled enclosure painted in colour as per specifications. The UPS shall be suitable for normal, emergency, recharge, by-pass and maintenance mode including bypass arrangement. The UPS shall have a microprocessor based display and control panel. UPS shall have own batteries with 30 minute battery back-up with SMF batteries .Complete system must be provided as per specifications approved drawing and as per site requirement including inter connecting cables from battery to UPS, UPS to panel with single core copper cabling etc. UPS shall work on parallel/ hot redundancy mode, cost of supporting kit shall be included. supports for complete system as approved by the Engineer in charge complete in all respect.
Part D: Solar System
Part E: Ventilation System System
200 mm dia/50 Pa
350 mm dia/50 Pa
SANITARY FIXTURES AND FITTINGS
Receving, checking, storing and fixing in position European water closet comprising of :-
Wall hung European W.C. Pan in white colour, on approved type of chairs.
C.P jet spray / health faucet with required length of flexible tube, clamp and bracket for fixing to wall
15 mm C.P. brass heavy quality angle stop cocks for flushing cistern and jet spray / health faucet
Solid bakelite water closet cover and seat with C.P. hinges and rubber buffers.
Necessary pipe connection to CI / PVC soil pipe.
Painting bracket with two coats of white enamel paint over a coat of primer,
WC, seat & cover, brackets, flush valve / flushing cistern, jet spray / health faucet, angle stop cocks supplied by owners. All other materials and labour to complete the work by contractor. Including, providing and fixing P.V.C. WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia PVC pipe of required length and proper connection to C.I. / PVC pipe complete as required.
Receving, checking, storing and fixing oval / rectangular wash hand basin, counter top / counter sunk, with central tap hole on counter comprising of :-
Concealed type brackets fixed to wall with adjustable clamp to push against counter rim.
32 mm heavy plated C.P. waste coupling fitting with or without pop-up.
32 mm heavy plated C.P. bottle trap with cleaning eye with extension piece and wall flange.
Painting brackets with two coats of white enamel paint over one coat of primer.
CP pillar cock / basin mixer with 15 mm C.P. brass heavy grade flexible inlet connection with C.P. nut (minimum length 450 mm) made to measure .
15 mm C.P. brass heavy quality angle stop cock
Fixing, testing and commissioning of automatic flushing systems for urinal to ensure pre-flush & flushing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells, eyes electrically operated solenoid valve, step down transformer / equipment and any other item required to provide satisfactory functioning. Including necessary wall cutting / chasing and making good, as required.
15 mm CP sink cock / sink mixer table mounted / wall mounted
(S.S. Sink, sink cock / sink mixer, waste coupling fitting, bottle trap supplied by Owner. Rest including brackets by contractor.
Part D: Solar System
G.I. Heavy class pipe sleeves of specified diameter corresponding to the pipe size shall be provided wherever the pipes are crossing the fire rated walls/floors slab and sealing the sleeves with glasswool in between and fire sealant compound on either end, all as per E-I-C's requirement
(S.S. Sink, sink cock / sink mixer, waste coupling fitting, bottle trap supplied by Owner. Rest including brackets by contractor.
Part D: Solar System
Part E: Ventilation System System
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
(S.S. Sink, sink cock / sink mixer, waste coupling fitting, bottle trap supplied by Owner. Rest including brackets by contractor.
Part D: Solar System
Part E: Ventilation System System
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
Cost shall be inclusive of (a)Making maximum of 7.5 x 7.5 cm chase in wall and floors for the pipe, making good the same by using 1:2 cement mortar over the wire mesh complete as required.
Part D: Solar System
Part E: Ventilation System System
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
15 mm (Internal Toilets )
Part D: Solar System
Part E: Ventilation System System
Part D: Solar System
Part D: Solar System
Part E: Ventilation System System
Providing, fixing, jointing and testing, heavy quality gun metal butterfly valve with rubber gasket, flanges / unions, nuts, bolts, washers, etc. complete, as approved by the Architect and Engineer-in-charge for water supply lines of the following nominal bore (NB) size:
Part D: Solar System
Part E: Ventilation System System
Part D: Solar System
Providing, fixing, jointing and testing, heavy quality gun metal full way gate valve including flanges / unions, nuts, bolts, washers, etc. complete, as approved by the Architect and Engineer-in-charge for water supply lines of the following nominal bore (NB) size:
Providing, fixing, jointing and testing, heavy quality gun metal or brass non return valve confirming to IS 778, with screwed / flanged ends, 20 kg/m2 of Simplex or equivalent make, on water supply lines of the following nominal bore (NB) size:
Providing, fixing and testing, heavy quality Pressure reducing valves of RB, Audco or equivalent make as approved,including flanges / unions, nuts, bolts, washers, Pressure guages, etc. complete by the Architect and Engineer-in-charge for water supply lines of the following nominal bore (NB) size: The upstream water pressure may be upto 25 kg/cm2g max. and downstream pressure min. 1 kg/cm2g.
Part D: Solar System
Providing, fixing , testing and commissioning threaded / double flanged water meter with direct reading dial in KL with all necessary fitting such as threaded pieces, unions pressure gauge, isolation cock, flanges piece for future removal, flanges / unions, NRV,Stainer,Butterfly valve complete with all necessary assesorries & testing charges
Part D: Solar System
Part E: Ventilation System System
Providing and fixing Brass Air release valve with Isolation (Ball) valve, double acting, of approved make, having 2 chambers with ebonite ball, small and large orifices with isolating stop screw down valve, GM seats, high tensile brass spindle with cap, conforming to standard water works pattern. Flanges as per IS : 15381, flat faced and drilled, complete of the following nominal bore (NB) size:
Providing and fixing C.I. “Y” strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanged / unions nuts, bolts and washers complete as required.
Part D: Solar System
50 mm dia.
Supply, Installation, Fixing, Testing and commissioning of 150 ltrs. Capacity Water cooler complete with suitable foundation, MS jali cage, 15Amps. Socket, required LED light in cage and 02Nos. Earth connections with cage 8 SWG GI wires.
Supply, Installation, Fixing, testing and commissining of Hand pump with suitable foundation and all other accessories and necessary equipments.
Supplying P.V.C. water storage tank of approved quality with closed top with lid ( Black ) Multilayer with all its accessories, valves and including the foundation.
200 mm thickness x 125 mm dia.
200 mm thickness x 40 mm dia.
200 mm thickness x 25 mm dia.
Supplying P.V.C. water storage tank of approved quality with closed top with lid ( Black ) Multilayer with all its accessories, valves and including the foundation.
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
Will keep provision of sleeves…..
Supplying P.V.C. water storage tank of approved quality with closed top with lid ( Black ) Multilayer with all its accessories, valves and including the foundation.
Providing, fixing, jointing and testing heavy duty, PVC SWR pipes B-type, - 6 kg/cm2 pressure for soil and waste water drain including jointing with rubbering / solvent / solution and airtight joints, with necessary specials, couplers, elbow, equal tees, tail piece, adapter (both male and female), reducer (single stage, double stage and triple stage), end cap, fabricated bend, etc., and lubricant or jointing material, including testing, cutting, making good the wall, ceiling and floor etc. complete of the following nominal bore (NB) size: The rate shall include the cost of PP cowl for vertical downtake pipes., The pipes shall be having soundproofing charecterstices laid under floor / fixed on walls, and in pipe shafts etc. complete.
Part D: Solar System
Part D: Solar System
lvent joint. (This will cover Soil, waste pipe running from inside toilet area )
Part D: Solar System
Providing, fixing, jointing and testing PVC traps of self cleansing design with water seal not less than 50 mm.,jointing with rubbering / solvent / solution and airtight joints, with necessary specials, cutting chases / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing , etc. complete, as required. The trap shall be 'P' type, of following sizes: Temporary airtight PVC cover to be provided to prevent dirt entry.
110 mm dia outlet
160 mm dia outlet
15 mm CP sink cock / sink mixer table mounted / wall mounted
(S.S. Sink, sink cock / sink mixer, waste coupling fitting, bottle trap supplied by Owner. Rest including brackets by contractor.
Providing, fixing, jointing and testing of PVC floor traps of self cleansing design with water seal not less than 40 mm.,jointing with rubbering / solvent / solution and airtight joints, with necessary specials, cutting chases / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing , etc. complete, as required. The trap shall be of following sizes: Temporary airtight PVC cover to be provided to prevent dirt entry.
75 mm dia outlet ( Floor Clean Out )
Part D: Solar System
75 mm dia outlet
Providing, fixing, jointing and testing heavy duty, PVC SWR pipes, - 6 kg/cm2 pressure for rain water drain including jointing with rubbering / solvent / solution and airtight joints, with necessary specials, couplers, elbow, equal tees, tail piece, adapter (both male and female), reducer (single stage, double stage and triple stage), end cap, fabricated bend, etc., and lubricant or jointing material, including testing, cutting, making good the wall, ceiling and floor etc. complete of the following nominal bore (NB) size: The rate shall include the cost of PP cowl for vertical downtake pipes., The pipes shall be having soundproofing charecterstices (Soundproffing performance with flow rates of 2 l/s & noise levels not exceeds 8 dB A) soil & Waste / ventilating pipes conforming to DIN 1986/ EN 1451 laid under floor / fixed on walls, and in pipe shafts etc. complete.
Part D: Solar System
Part D: Solar System
Providing and constructing R.C.C (mix 1:2:4) support pillars for G.I / C.I / PVC / PPR / CPVC, etc. pipes at ground level, service floor or over terrace complete with plastering as approved.
Part D: Solar System
110 dia. NB pipe.
Part D: Solar System
Part E: Ventilation System System
160 dia. NB pipe.
75 mm dia
50 mm dia
110 mm dia
Providing & fixing rain water `Khurras' required depth with lead flashing around the pipe with one piece lead sheet of 3 mm thick set on a layer of cold bitumen. Including Heavy duty CI/MS grating as per drawing complete as required.
EXTERNAL DRAINAGE AND RAIN WATER
Excavation by mechanical means for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, hard Murrum, soft & hard rock including removing the excavated material for all lift and lead with in the plot boundery,stacking, spreading as directed, including dewatering, fencing, lighting, watching, barricading, guarding, shoring, strutting, preparing the bed for foundation etc. complete as per specification,drawing and Instruction of engineering in charge.
From existing Ground level up to 500 m deep
Filling Work
Refilling the trenches with available excavated soil upto 300mm above the pipe and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc.complete as per specification, drawing and as directed.
Providing , laying, jointing & testing NP2 class RCC pipes (IS 458) with mortise - tenon, jointed with cement and with RCC collar to cover and overlap the joints laid to correct levels below ground in trenches upto required depth including excavation in all kind of soil (including hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material, dumping it on site or carting away to lead of 100 meters as directed and making good the same complete as required. Price to include 150 mm thick PCC (1:4:8) haunches upto centre at the joints to cover the collar and 150 mm on bothsides and 400 mm wide cradles for intermediate supports at maximum 1 meter centre to centre in brick masonary (duly plastered 1:5 CM) on 100 mm thick PCC 1:4:8 over 230 mm rubble soling. The pipes shall be of following nominal bore (NB) size:
150 mm NP2 class RCC pipe.
Providing, fixing, jointing and testing salt glazed stoneware gully trap, class `A', of 100 mm. dia. inlet and 100 mm. outlet, including excavation in all soil types, bailing or pumping out water from trenches, shoring whenever necessary testing,refilling, in layers ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed, incl. embedding the trap in CC 1:2:4, construction of brick masonry chamber, internal clear size 300 mm. x 300 mm., in brick work 230 mm. thick, in CM 1:4, plastering inside, outside and all exp
osed surfaces with CM 1:3, 12 mm. thick, providing, fixing CI frame and cover 300 x 300 mm., weighing together not less than 12.5 Kg., painting of all CI items with 3 coats of approved bitumastic paint, etc. complete.
Part D: Solar System
Supply & fixing CI Manhole cover with frame ( LD )
Extra over and above item no. 4.04 beyond 1.5 m. depth, for every additional depth of 0.1 m. or part thereof, for brick masonry Inspection chamber.
Extra over and above item no. 4.06 beyond 1.5 m. depth, for every additional depth of 0.1 m. or part thereof, for brick masonry Inspection chamber.
0.6M x 0.60M and Upto 1.0M clear depth for sewer
0.9M x 0.60M and Upto 1.2M clear depth for sewer
Providing and fixing RCC manhole cover and frame of approved brand conforming IS 12592:2002 with lifting arrangement, including testing ,inspection of material sample and finished product at Manufacturer's work , etc. complete as specified and as directed by Engineer-in-Charge. (Inspection shall be as per guidelines of IS 12592) including fixing with M-30 concrete coping and locking arrangement ,as per specification etc. complete as specified and as directed by Engineer-in-Charge.
560mm internal dia and grade designation LD-2.5 as per IS-12592
Extra over and above item no. 4.10 beyond 1.5 m. depth, for every additional depth of 0.1 m. or part thereof, for brick masonry chamber.
Constructing conical manhole / inspection chamber for sewage, 1350mm dia at bottom & tapering upto 600mm dia at top in 450mm brick masonry in c.m. 1:5, with 230mm 1:3:6 plain cement concrete bedding, necessary benching in concrete (M-15) 20mm thick smooth cement plasters from inside (1:4) rough cement plaster from outside. Plaster (1:4) smooth finish inside & rough outside cast iron steps wherever necessarywith heavy type (175 kg) C.I. manhole cover & frame (Approved Make) incl. necessary excavation in all soil types, refilling sides in layers, ramming & consolidation, watering, curing removing away the surplus earth or dumping it on site as directed (Depth 1500mm to 3000mm to invert).
Extra over and above item no. 4.12 beyond 3.0 m. depth, for every additional depth of 0.1 m. or part thereof, for brick masonry manhole / Inspection chamber.
Providing and fixing, PVC heavy duty steps in manhole, water tank, septic tank, sumps, etc., of size 150 mm. x 100 mm. x 22.5 mm, including cutting, chasing the RCC / Brickwork and making good the same complete as required, etc.
Providing and fixing, PVC heavy duty rungs in RCC walls / brick walls of water tank, septic tank, sumps, etc., of size 150 mm. x 150 mm, including cutting, chasing the RCC / Brickwork and making good the same complete as required etc.
Charges for connection to main drainage from the local authority as per the local rules and regulations, including excavation in all kind of soil (including hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material dumping it on site or carting away to lead of 100 meters as directed and making good the same complete as required. Liasioning fees shall not be included in the rates. Piping paid as per respective items. (If in case of existing drain is available)
Sump Pit Pump
Water Supply Transfer pump
Supply, installation, testing & commissioning of Submersible single stage single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, electrical panel with in built level controller with operational mode as one pump working at low level, both pumps at high level with a hooter alarm and cut off at dry level as determined. The pump shall be provided with a lifting devise of pull chain including interconnecting piping with bypaas return line, Butterfly valves for all lines, 15 m cable etc. as per requirement complete in all respects. (Pumps shall be installed in a set of two pumps One working and One standby, with cascade operation).
(Pumps suitable to handle solids upto 8 to 10 mm size with C.I. body, SS 304 shaft, C.I. impeller with 15 mtrs cable, double mechanical seal).
Service : Water Supply Transfer pump
Each pump Flow rate : 2.7 LPS
Head :15 Mts
No of pump : (1w+1s)
Head :15 Mts
Rain Water Harvesting pit
Providing material and Constructing brick masonry circular type Rain water harvesting pit 3 m internal dia upto 5.0 m total depth (1.5 Effective depth), inside & outside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and finished with a floating coat of neat cement, 2 Nos. S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including Excavation, foot rests, centering, shuttering all complete all complete as per standard design : The rainwater harvesting pit sh
all be constructed according to the structure drawing.
Boring/drilling bore well of required dia for casing/ strainer pipe in All types of soil, by suitable method prescribed in IS: 2800 (part I), including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge.
300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC shallow well casing (CS) pipe of required dia including end cap, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (Make :- Supreme, Finolex, Ashirwad)
150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (Make :- Supreme, Finolex, Ashirwad)
Head :15 Mts
Supplying, fixing, jointing and testing of uPVC pipes conforming to IS 4985 class V (6 kg/cm2) including injection moulded fittings, all complete as per direction of Engineer -in-charge. (for vent) (Make :- Supreme, Finolex, Ashirwad)
110 mm nominal size dia
Supplying and wrapping 150 gsm geotextile cloth around the well screen pipe.
Part D: Solar System
Part E: Ventilation System System
Supplying, filling, spreading & leveling stone boulders of size range 50 mm to 200 mm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and lowering rounded & fully washed 3-6 mm pea gravel for packing of tube well construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & sizes as per actual requirement, all completed as per the direction of the Engineer-in-charge.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I).
Chemical Holding and Neutralization Tanks
Connections to RCC Water Tanks The Contractor shall provide all inlets, outlets, washouts, vents, ball cocks, overflows control valves and all such other piping connections including level indicator to water storage tanks as called for. All pipes crossing through RCC work shall have puddle flanges fabricated from MS/GI pipes of required size and length and welded to 6/8 mm thick MS plate. All puddle flanges must be fixed in true alignment and level to ensure further connection in proper order. Full way gate valves of a preferred make shall be provided as near the tank as practicable on every outlet pipe from the storage tank except the overflow pipe. Overflow and vent pipes shall terminate with mosquito proof grating. The overflow pipe shall be so placed to allow the discharge of water being readily seen. The overflow pipe shall be of size as indicated. A stop valve shall also be provided in the inlet water connection to the tank. The outlet pipes shall be fixed approximately 75mm above the bottom of the tank towards which the floor of the tank is sloping to enable the tank to be emptied for cleaning.
10000 Liters - Fire
Part D: Solar System
Part E: Ventilation System System
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
AUTOMATIC WATER SPRINKLER SYSTEM
200 mm dia
150 mm dia
Part D: Solar System
65 mm dia
50 mm dia
40 mm dia
32 mm dia
Supply, installation, testing & commissioning of conventional std coverage standard response quartzoid bulb type sprinkler with 15mm screwed end connection of K-factor of K80 & sprinkler bulb of size 5mm.
Pendent sprinkler of 68 deg.C
Upright sprinkler of 68 deg.C
Supply only of K80 Spare Sprinklers individually packed in polythene bags.
Supplying, installing, testing and commissioning of Quick response recessed sprinklers with Nickel chrome plated finish - K-80/ 68 deg.c (Pendent Type)
Supplying, installing, testing and commissioning of Ductile Iron OSY gate valve PN 16 rating. along with the supervisory switch, companion flanges, nut, bolt, washer and gaskets.
Supplying, installing, testing and commissioning of Water flow switch suitable for 150 mm dia with all its accessories shall be connected to fire alarm panel through cable. Cable shall be measured seperately in FAS BOQ
Supplying, installing, testing and commissioning of glycerine filled Pressure gauge (0-20bar) 150mm diameter with gauge cock and all its accessories
Test drain assemby generally complete as specified and as shown in the drawing. i) sight glass ii) ball valve 50 dia
Part D: Solar System
Part E: Ventilation System System
Supplying, installing, testing and commiss
Part D: Solar System
Part E: Ventilation System System
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
Supplying, installing, testing and commissioning of 25mm dia GM air release valve with copper alloy globe valve.( Make: Leader)
FIRE HYDRANT SYSTEM
Supply, Installation, Testing & commissioning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the steel structural members. 10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bolts & washers & structural pipe support shall be one coat of zinc primer and two coats of fire red enamel paint Shed No.536 of IS 5: 1994 complete with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge. ( Pipe - JINDAL Make)
Supplying, erecting and commissioning of Landing Hydrants comprising of the following
Single headed hydrant valve as per IS 5290, made of gunmetal with 63 mm dia instantaneous outletof 80 mm dia fanged inelt ,Blank caps , chain and hand wheels etc complete.
2 lengths of 15 Mtr long, 63mm dia RRL hose as per IS:636 Type A with instataneuos couplings and Hoses shall be stored in side the hose cabinet.
Supply, Installation, Testing & commissioning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the steel structural members. 10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bolts & washers & structural pipe support shall be one coat of zinc primer and two coats of fire red enamel paint Shed No.536 of IS 5: 1994 complete with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge. ( Pipe - JINDAL Make)
Single headed hydrant valve as per IS 5290, made of gunmetal with 63 mm dia instantaneous outletof 80 mm dia fanged inelt ,Blank caps , chain and hand wheels etc complete.
2 lengths of 15 Mtr long, 63mm dia RRL hose as per IS:636 Type A with instataneuos couplings and Hoses shall be stored in side the hose cabinet.
1 no. Gun metal short branch pipe with nozzle.
Part D: Solar System
iii)Type: Single Head
I) Flow rate: 450 Ltrs/Min
Supplying, Installing, testing and commissioning BUTTERFLY VALVE WAFER TYPE LEVER OPERATED PN-1.6 WITH bronze/gunmetal seat seal ISI marked complete with bolts & nuts, bolts & washers, gasket conforming to IS 13095 of following sizes as required
Supplying and installation of NON RETURN VALVE confirmong to IS 5312, complete with rubber gasket, GI bolt, nuts, washer, etc. as required
Supplying, installing and commissioning of Bourdon type Pressure gauge (150mm dial) with gauge cock - range 0-25 kg/sq.cm(g).
ABC Dry Powder type - 5Kg. Capacity as per IS:15683
CO2 type - 4.5 Kg. Capacity as per IS:15683
Sub-total of Fire Fighting System Cost : D
ENVIRONMENT MANAGEMENT PLAN (Fixes Cost)
Design and Preconstruction Phase
Regulatory Clearances/Permits like Tree Felling Permission and Compensatory Plantation
Regulatory Clearances/Permits like CTE/CTO, Authorization etc., Workman compensation insurance etc.
Lumpsum
Contractors Qualified Environment, Health and Safety Expert/s, PMC's and DSC's Qualified Environmental Experts,PIU and PMU level Qualified Environmental Expert
Baseline Monitoring: Ambient Air Quality
Number
Baseline Monitoring: Ambient Noise quality
Baseline Monitoring: Ground Water quality and Drinking Water
Baseline Monitoring: Surface Water quality
Baseline Monitoring: Soil Quality
Shifting of Utility (if applicable)
Construction Phase (1 Year)
Traffic management at worksite (signage, Warning Lights etc.)
Horticulture and Green Area Development
Waste and wastewater management
Monitoring: Ambient Air Quality
Monitoring: Ambient Noise quality
Number
Baseline Monitoring: Ambient Noise quality
Baseline Monitoring: Ground Water quality and Drinking Water
Monitoring: Ground Water quality and Drinking Water
Baseline Monitoring: Soil Quality
Monitoring: Surface Water quality
Monitoring: Soil Quality
Rainwater Harvesting structures
Noise Barrier near school and residential areas
Restoration of construction site
Water sprinkling during construction
Operation Phase (1year)
Regulatory Clearances/Permits like Fire NoC, etc.
Waste and wastewater management (including installation and management of Septic tank)
Package No: CW-06 (Lot-1)
Monitoring: Surface Water quality (depending on availability)
Bill of Quantities
BOQ item no
Earth work in excavation by manual/ mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. (For site preparation)
All kinds of soil
In ordinary rock
In hard rock (Blasting prohibited)
EHS audit Annually
All kinds of soil
In ordinary rock
In hard rock (Blasting prohibited)
Earth work in excavation by manual means upto a depth of 2 m below the existing ground level for foundation, trenches of foundations, footings of columns/ walls, retaining wall, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.
All kinds of soil (ordinary soil/ hard soil/ dense soil)
In ordinary rock (soft rock/ medium rock/ hard shale)
In hard rock (soft rock/ medium rock/ hard shale) (Blasting prohibited)
Earth work in excavation by mechanical means upto a depth of 2 m below the existing ground level for foundation, trenches of foundations, footings of columns/ walls, retaining wall, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.
All kinds of soil (ordinary soil/ hard soil/ dense soil)
In ordinary rock (soft rock/ medium rock/ hard shale)
In hard rock (soft rock/ medium rock/ hard shale) (Blasting prohibited)
Same as Items 3.0 & 4.0 above but for each additional 1 m depth or part thereof beyond the initial depth of 2 m
All kinds of soil
In ordinary rock
In hard rock (Blasting prohibited)
Disposal of surplus earth/ unserviceable material from the work site including loading and unloading complete as directed for a total of 15 km (i.e. 10 km beyond the initial lead of 5 km)
Excavated earth
Excavated rock
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered).
Upto a depth of 1.50 m
Above 1.50 m upto 3.00 m depth
Earthwork in filling (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
With available excavated earth
Green area maintenance (Monitoring of Survival of trees) : Annually
Extra over Item for additional lift of 1.5m or part thereof for all types of soils
Sand filling in plinth in layers not exceeding 150mm in depth including breaking of clods, consolidating by watering and ramming complete as directed (maximum depth 45 cm)
SUB TOTAL
Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by the Engineer-in-charge.
Shuttering for sides of plain cement concrete work in blinding concrete, plinth protection, copings, sills etc.
Foundations, footings, bases of columns, raft, grade slab etc. for mass concrete (using steel)
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (using steel)
Suspended floors, roofs, landings, balconies and access platforms, shelves (using steel)
Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel)
Columns, Pillars, Piers, Abutments, Posts and Struts (using steel)
Stairs/ spiral staircase, (excluding landings) (using timber)
Edges of slabs and breaks in floors and walls (using timber)
Weather shade, Chajjas, corbels etc., including edges (using timber)
Extra for additional height in centering, shuttering wherever required with adequate bracing, propping etc., including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)
Others
SUB TOTAL
Plain cement concrete works in foundation bed for footing steps, walls, brick works etc. below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
1 :3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls etc. and all works above plinth level such as pilasters, columns, pillars, posts, struts, buttresses, parapets, coping, plain window sills, fillets, sunken floor etc.,, up to first floor level, excluding the cost of centering, shuttering and finishing
Implementation of Emergency Preparedness Plan, Grievance Redress Mechanism, Stakeholder Engagement activities, Traffic Management,etc.
1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size)
SUB TOTAL
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
All works up to plinth level
All works above plinth level up to first floor level
Extra for providing richer mixes:
Providing M-30 grade concrete
Implementation of Corrective Action Plan
Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required)
Thermo-Mechanically Treated bars
Training and Capacity Building
Providing and fixing parallel threaded couplers conforming to ls code on "Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement-Specification", to reinforcement bars including threading, enlargement at connection by forging, protecting the prepared reinforcement bars and related operations as required to complete the works as per direction of Engineer in-Charge
Coupler for 16 mm diameter reinforcement bar
Coupler for 20 mm diameter reinforcement bar
Coupler for 25 mm diameter reinforcement bar
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections.
Providing & mixing approved pure acrylic based polymer modified waterproofing compound in concrete work of approved brand and quality, mixed with cement in required proportions as per manufacturer's guidelines, specifications and as directed by the Engineer-in-Charge. The product shall comply with IS: 9103 and IS: 2645. The product must be free of chlorides and shall comply with ASTM C494 Type A & D.
Note : 1) Reinforced cement concrete shall be paid separately under relevant item
SUB TOTAL
Brick work with common burnt clay modular lst class bricks in foundation and in plinth:
In Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work in cement mortar with first class brick in superstructure above plinth level up to first floor level in all shapes and sizes:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Tree felling
Half brick masonry with common burnt clay (non modular) first class bricks in superstructure above plinth level up to first floor level
Cement mortar 1:4 (1 cement :4 coarse sand)
Extra over item No 25.1 above for each subsequent floor or part thereof above the first floor level.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
SUB TOTAL
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with:
Cement mortar 1 :6 (1 cement: 6 coarse sand)
SUB TOTAL
Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre-polished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade, area of slab upto 0.50 sqm (For laboratory counter tops)
Providing edge moulding to 18 mm thick marble stone counters, Vanities, etc.„ including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in Charge.
Granite work
Extra for fixing marble/ granite stone, over and above corresponding basic item, in facia and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing Of cut edges etc. complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to lS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours and shades of any size as approved by Engineer-in-Charge, in walls, skirting, risers of steps and dados, over 12 mm thick bed Of cement mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Normal range
Providing polished Vitrified wall tiles of approved quality, size, shape and thickness not less than 8 mm on walls and skirting over cement mortar bed 10 mm thick in prop.1:3 (1 cement: 3 coarse sand) including cutting where necessary finished with flush pointing with adhesive or white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed.
Normal range
Sub total of Enviroment Management Plan Cost: E
Granite Stone of approved shade
SUB TOTAL
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length.
With Teak wood/ Sissu wood.
Providing and fixing ISI marked flush door shutters conforming to lS:2202 (Part I) non-decorative type, core of block board construction with frame of lst class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including lSl marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with wooden battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) :
Rectangular or square
Extra if louvers are provided (not exceeding 0.2 sqm) in all wooden frames and shutters (overall area of the door shutter to be measured)
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:
With Teak wood/ Sissu wood - 50 x 20 mm
Providing and fixing 18 mm thick,150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, lS:3087 marked, including top cover of 6 mm commercial ply wood conforming to lS:303 BWR grade, nickel plated M.S. pipe 20 mm dia (heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100x40x40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete.
Extra for using veneered particle board conforming to lS:3097 Grade I, in item of pelmet 18 mm thick 150 mm wide.
Particle board with decorative veneering on both sides
Providing and fixing teak wood lipping of size 25x3 mm in pelmet.
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete:
25 mm dia
Providing & fixing decorative high pressure laminated sheet of plain/ wood grain in gloss/ matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to lS : 2046 Type S, including cost of adhesive of approved quality.
1.5 mm thick
SUB TOTAL
per kg
Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia. steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
ln stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Rate Only
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered).
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia. Wire and 1.4 mm aperture on both sides
Providing and fixing M.S.fan clamp type I or II of 16 mm dia. M.S.bar, bent to shape with hooked ends in RCC slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars, etc. including priming coat with approved steel primer all complete.
Fixed to openings/ wooden frames with rawl plugs screws etc.
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/ honey-comb area of concrete/ masonry by suitable gun/ pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-charge
Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non-shrink compound in concrete/ BCC work
SUB TOTAL
Providing and fixing bolts including nuts and washers complete.
FLOORING
General Note for Flooring :
All Stone flooring should be adequately protected with plastic sheets, POP layer till final polishing & handing over, without any extra payment.
Providing and laying damp proof course with cement concrete in prop 1 :11/2:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
40 mm thick
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing soling with stone, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
Stone Soling, 150 mm
Filling sunken floor with broken brick bats/ stone aggregates and sand including compacting and supplying of materials complete as specified and directed for all levels.
Brick bats
Providing and laying damp proof course with cement concrete in prop 1 :11/2:3 with graded stone aggregate of 10 mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Grand Total of Adokgiri Govt. Upper Primary School
Bill of Quantities for Chotcholja Govt. Upper Primary School
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 :4 (1 cement: 4 coarse sand).
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade Of the slabs, including rubbing and polishing complete
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre.
Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to lS:15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600 x 600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg Of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling, grouting and finishing complete as per direction of Engineer-in-charge
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, etc. all complete as specified and as directed by the Engineer-in-Charge. (In strips or any other approved pattern for Ramp areas)
Providing Vitrified Anti-skid Tiles of approved quality size, shape not less than 8 mm on floor, skirting over a cement mortar bed 15 mm thick of 1:3 (1 cement: 3 coarse sand) complete at all level as specified and directed.
SUB TOTAL
Normal range (For toilets)
PLASTERING
Providing and applying 15 mm thick cement plaster on rough side of single or half brick wall of mix: in cement mortar 1:6 (1 cement : 6 coarse sand) to interior masonry/ concrete wall surfaces
Providing and applying 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement: 6 fine sand).
Providing and applying 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self-curing mortar of approved make as per the direction of Engineer-in-Charge.
per bag of 50 kg cement
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 in or part thereof.
Providing and applying 12 mm of cement plaster finished with a floating coat of neat cement of in cement mortar 1:4 (1 cement : 4 coarse sand) to interior masonry/ concrete wall surfaces
SUB TOTAL
Providing & fixing G.I. Hexagonal chicken wire mesh of 19 size of aperture (12mm x 20 gauge) confirming to IS : 3150 at the junction of dissimilar surfaces of brick / block masonry wall and RCC column / beams and the like including necessary "U" nails / screws with cleats for fixing, overlapping, necessary scaffolding etc. complete all as per specification and as directed by the Engineer-in-charge for all heights and all locations.
PAINTING, OILING, POLISHING, VARNISHING WORKS
Providing and applying Plaster of Paris put
ty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
White washing with lime to give an even shade for new work (three or more coats)
Finishing walls with Acrylic smooth exterior paint of required shade, including scaffolding:
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat Of exterior primer applied @ 2,20 kg/10 sqm)
Wall painting with acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
New work (two coats)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
On steel work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
New work (two or more coats)
Same as Item 1.0 above but for each additional 1 m depth or part thereof beyond the initial depth of 1.5 m
SUB TOTAL
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron/ steel works
With borrowed earth/ stone dust carriage upto 5 km
FENCING, SITE DEVELOPMENT & MISCELLANEOUS WORKS
Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately).
75 mm thick back filling for pitching including supplying of required materials and consolidation etc. complete with:
Moorum/Any kind of soil
Providing and laying tactile tiles (for vision impaired persons as per standards) of size 300 x 300 x 9.8mm having water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement: 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) (For total height of 6.60 m (i.e.3.10m over and above the standard height of 3.5 m)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 in above ground level and removal of rubbish up to a distance of 50 in outside the periphery of the area cleared.
Felling trees of the girth (measured at a height of 1 in above ground level), including cutting Of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
Beyond 30 cm girth up to and including 60 cm girth
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 in and lift up to 1.5 m in all kinds of soil
1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) (For cement concrete screed below floors)
Chlorpyriphos emulsifiable concentrate of 20% (or approved equivalent)
litre
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 ltr/ Rm including drilling and plugging holes etc.:
litre
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
litre
Treatment of soil under floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor:
Treatment of masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement: 2 coarse sand) to the full depth of the hole:
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia. holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing
Rectangular shape of 453 x 357mm
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia. PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910, on 12 mm dia. steel bar conforming to IS:1786, having minimum cross section as 23x25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) complete as per design.
Supplying and fixing C.I. cover without frame for manholes:
560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg
SUB TOTAL
HD-20; Circular shape 560 mm internal diameter
ALUMINIUM WORK
For fixed portion; using anodized aluminium (anodized transparent or dyed to required shade according to ls:1868, minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately); using anodized aluminium (anodized transparent or dyed to required shade according to ls:1868, minimum anodic coating of grade AC 15)
Extra over item No 14.2 & 15.0 above for each subsequent floor or part thereof above the first floor level.
Providing and fixing glazing in aluminium door. window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge:
With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections.
For fixed portion
SUB TOTAL
Initial test ITest Load 2.5 times the sate capacity
WATER PROOFING
Note: All the waterproofing treatment shall be executed through a recognized water- proofing agency approved by the Engineer-in-charge. A written guarantee on non-judicial stamp paper shall be submitted by the Contractor for a minimum period of ten years from the certified date of completion for the satisfactory performance of the entire water-proofing system.
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for underground structures as directed by Engineer-in-charge and consisting of :
(i) 1st layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound conforming to lS:2645 in the recommended proportion over the levelling course (levelling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.
(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.
(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 0.008 cum/sqm thoroughly embedded in the 2nd layer.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to ls:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement: 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge:
Providing and placing in position suitable PVC water stops conforming to lS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:
Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying:
1st layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours.
2nd layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to lS:2645 and approved by Engineer-in-charge over the PCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats with mortar using broken bricks/ brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to lS:2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1 :5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to lS:2645 and approved by the Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs.
(c) After two days of proper curing, applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to lS:2645 and approved by Engineer-in-charge.
(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1 :4 (1 cement: 4 coarse sand) admixed with water proofing compound conforming to lS:2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm squares, 3 mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.
All above operations to be done in order and as directed and specified by the Engineer-in-Charge.
With average thickness of 120 mm and minimum thickness of 65 mm.
Grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry: 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry: 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fibre brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
SUB TOTAL
Providing and fixing anodized aluminium (anodized transparent or dyed to required shade according to lS:1868. Minimum anodic coating of grade AC 15) sub frame work tor windows and ventilators with extruded built up standard tubular sections of approved make conforming to lS:733 and lS:1285, fixed with dash fastener of required diameter and size.
Making soak pit 2.5 in diameter 3,0 metre deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diamcter,1.8 in long complete as per standard design
DOOR AND WINDOW FITTINGS
Hinges
Providing and fixing lS:12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete:
Providing and fixing oxidized M.S. double acting spring hinges with necessary screws etc. complete.
Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/ top hung windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge
Providing and fixing bright finished brass 100 mm mortise latch and lock, lsl marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per ls:1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3 mm thick & 2100 mm long with SS screws etc. complete as per direction of Engineer-in-Charge
Anodized (AC 15) aluminium tubular handle bar (for glass door)
Locks & latches
Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing bright finished brass 100 mm mortise latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing Brass 100 mm mortise latch and lock with 6 levers without pair of handles (best make of approved quality) tor aluminium doors including necessary cutting and making good etc. complete
Providing and fixing 100 mm aluminium baby latch, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.
Providing and fixing aluminium sliding door bolts, lSI marked anodized (anodic coating not less than grade AC 10 as per ls:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
Extra over item 17.0 above for each subsequent floor or part thereof above first floor level.
Door closers, stoppers & tower bolts
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with lSI, lS:3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISl marked, anodized (anodic coating not less than grade AC 10 as per lS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Twin rubber stopper
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to lS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 kg, for doors, including cost Of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness (For glass door)
Window fittings
Providing and fixing aluminium casement stays, lSl marked, anodized (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete.
Signages (Door mounted)
SUB TOTAL
For vertical surface two coats @ 0.70 kg/sqm
Signages of 200 mm x 200mm size and make and mounted on door / wall, fixed with SS screws including all accessories etc. complete.
SUB TOTAL
Extra over item No 23.0 above for each subsequent floor or part thereof above the first floor level.
Provisional sum for carrying out the horticulture and plantations including all accessories and allied civil & electromechanical work required for the successful completion of the work as per drawings, technical specifications and as directed by the Engineer-in-charge
Sub-Total of Civil cost: A
Electrical Works:
Providing, laying, connection, testing & commissioning of the following sizes of 1100V grade Copper conductor armoured underground cable & overall PVC sheathed cable as per ISI code in trenches including the cost of digging of trenches, sand cushioning with laying etc. and refilling the same in layers or by supporting them in walls and all other accessories as required.
With 4 core 16 sqmm
With 4 core 10 sqmm
With 4 core 6 sqmm
With 3 core 10 sqmm
Providing and fixing 75 mm high, 50 mm deep and 18 mm thick stone slab table rubbed, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
With 3 core 10 sqmm
Electrical Works:
Providing, laying, connection, testing & commissioning of the following sizes of 1100V grade Copper conductor armoured underground cable & overall PVC sheathed cable as per ISI code in trenches including the cost of digging of trenches, sand cushioning with laying etc. and refilling the same in layers or by supporting them in walls and all other accessories as required.
Cement plaster skirting up to 30 cm height, with cement mortar 1 :3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement.
With 3 core 10 sqmm
Extra for making chequers of approved pattern on cement concrete floors
, steps, landing, pavements etc.
Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture
Providing and laying 60 mm thick factory made cement concrete interlocking paver blocks of M-30 grade made by block making machine with strong vibratory compaction, of approved size. design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Felling trees of the girth (measured at a height of 1 in above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion):
Wiring in looping system with copper PVC cable 250/440 volt grade of size 1.5 sqmm of approved quality using PVC casing capping incluiding 5 amperes switch Indian best quality ceiling rose etc. capable to a highest point
Providing and laying 60 mm thick factory made cement concrete interlocking paver blocks of M-30 grade made by block making machine with strong vibratory compaction, of approved size. design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Medium Point wiring up to 6 mts (i)With copper conductor
Providing and fixing 6 mm diameter G.I. level adjusting hangers (up to 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm diameter and 50 mm long, complete as per direction of Engineer-in-charge.
Providing and fixing aluminium tower bolts, ISl marked, anodized (anodic coating not less than grade AC 10 as per lS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing 6 mm diameter G.I. level adjusting hangers (up to 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm diameter and 50 mm long, complete as per direction of Engineer-in-charge.
Sub-total of Civil Cost : A
Long point wiring upto 10mts (i) With copper conductor
Providing and laying 60 mm thick factory made cement concrete interlocking paver blocks of M-30 grade made by block making machine with strong vibratory compaction, of approved size. design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Felling trees of the girth (measured at a height of 1 in above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
Wiring as in item No.6 complete to a light plug point when fixed else where.
Long point wiring upto 10mts (i) With copper conductor
Wiring to a power plug as in item No.6 above with 2X4mm 2 including supplying & Fitting of 15Amp 5 in 1 SS combined with continuous earth wire to a power point complete
Wiring to a power plug as in item No.6 above with 2X4mm 2 including supplying & Fitting of 15Amp 5 in 2 SS combined with continuous earth wire to a power point complete
Drawing of Main and Sub-main line with DGSD approved VIR or PVC 250/440 Volt grade in PVC casing capping complete with all accessories.
With 2×2.5mm2 Copper Conductor
With 2X4 mm2 Copper Conductor
With 2X6 mm2 Copper Conductor
Drawing 3 phase Main Line 4 wire with DGSD approved VIR PVC cable 660 V grade in casing capping with all necessary accessories
With 4 X 6 sq. mm copper conductor
With 4 X 10 sq. mm copper conductor
Supplying & fixing of Load Kontaket Miniature Circuit Breakers (MCBs)
6 - 32 Amp. SP MCB
40 - 63 Amp. SPN MCB
40 - 63 Amp. TPN MCB
Supplying, fitting & fixing of Load Kontaket Miniature circuit breakers Double Pole (Isolator)
32 Amp DP Isolator
40 Amp DP Isolator
63 Amp DP Isolator
100 Amp DP Isolator
125 Amp DP Isolator
Supplying, fitting and fixing of Residual-current circuit Breaker with Overcurrent protection RCBOs assembled for AC applications upto 63A.
Supplying, fitting and fixing of Moulded case circuit Breaker of the following capacity
4 Poles 16 -63 Amp Capacity
4 Poles 80 -100 Amp Capacity
Supplying, fitting and fixing of SPN / TPN MCB Metal enclosure MCB Distribution box
Supplying and Making end Termination with Brass Compression Gland & Aluminium Lugs for Following size of PVC Insulated & PVC Sheated/XLPE Aluminium Conductor Cable of 1.1 KV Grade as required
Supplying, fitting and fixing of SPN / TPN MCB Metal Enclosure Distribution Board
12 Way (8+36) Modules
Supplying, fitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie Lamiated sheet cover in the front including painting etc. as required.
75mm x 75mm x 60mm deep
100mm x 100mm x 60mm deep
150mm x 150mm x 60mm deep
250mm x 300mm x 100mm deep
Supplying fitting and fixing Batten LED light fitting complete with all accessories for surface or pendant mounting as per Department direction and approved
Supplying fitting and fixing LED fittings of different wattage,surface or recess or pole mounting, direct or indirect luminair square or round shape also suitable for porch lighting etc.fitted with mirror reflect or complete with all neccessary accessories.
18 watt Round
10 watt Bulk head
Supplying fitting and fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED lamp.(a) with 25cm dia glass shade complete.
Supplying and fitting of ceiling fan AC operated type 220/250 volt. Complete with 3Nos of blades down rod canopy hanging shackle & regulator complete with 30mm length down rod supplied with the fan by the dealer but the extra length will be charged @ Rs25.00/ mtr
AC ceiling Fan '1400' mm sweeps
Supplying , installation testing & commissioning of self contained emergency light unit 1x3 watt double sided for wall / ceilling mounting with suspension / mounting kit, inbuilt standby battery( for 2hours backup)and battery charger etc.
1 x 3 W double sided
Supplying fitting and fixing of exhaust fan double bearing self lubricating type single phase 50Hz 250V AC operated complete with supporting frame, fan blades, nuts and bolts, fan regulator, capacitor, adjustable type lever and other petty accessories as required
Medium Duty Exhaust Fan
Supplying and Making Outdoor end Termination with Cast Resin Compound including Aluminium Lugs other Jointing Material for Following size of PVC Insulated & PVC Sheated/XLPE Aluminium Conductor Cable of 1.1 KV Grade as required
Supplying, fixing, connecting, testing and commissioning of calling Bell/ Bell indicator type suitable for 230 V as well as battery operated complete with all necessary accessories
Gong Bell
Ding dong Bell
Remote Bell
Supplying fitting & fixing earthing with GI earth plate 600 × 600mm × 6mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe etc with charcoal, salt set complete as required
Supplying and laying of 15mm × 5mm GI/Copper Strip at 0.50mts, below ground.
With 25mm×5mm copper strip
with 25mmx6mm GI strip
Long point wiring upto 10mts (i) With copper conductor
Medium Point wiring up to 6 mts (i)With copper conductor
with 25mmx3mm GI strip
Supplying, fitting and fixing of copper/Alluminium lightning Arrestor with 5no.s finger at the top & copper base plate at the bottom complete.
Short Point Wiring up to 3 mts (i)With copper conductor
Long point wiring upto 10mts (i) With copper conductor
Wiring to a power plug as in item No.6 above with 2X4mm 2 including supplying of 15Amp 5 in 1 SS combined with continuous earth wire to a power point complete
Medium Point wiring up to 6 mts (i)With copper conductor
12Way (8+36) Modules
Supplying fitting & fixing earthing with copper earth plate 600 × 600mm × 6mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe etc with charcoal, salt set complete as required
Providing & Fixing 6 SWG dia GI wire on Surface or in Recess for Loop earthing Along with Existing Surface/Recessed Conduit/Submain Wiring/Cable as required.
Providng & Fixing GI Tape 20mmx3mm Thick on Parapet or Surface of Wall for Lightning Conductor Complete as required. (For Horizontal Run)
Providng & Fixing GI Tape 20mmx3mm Thick on Parapet or Surface of Wall for Lightning Conductor Complete as required. (For Vertical Run)
Supply, installation, testing and commissioning of telephone outlets RJ 11, including supply and fixing of 16 SWG sheet steel back box of suitable size, recessed in wall, column as required.
Supply, installation, and commissioning of data outlets RJ 45 with 16 SWG sheet steel back box surface in wall column complete, for data communication as per drawings.
Supply, installation, testing and commissioning PABX complete all respect as per Drawing comprising of following as specified in specifications and drawings.
Supply, installation, testing and commissioning of Analogue Telephone sets features of 10 speed dialling numbers, wall mounting option etc, as specified in specifications
Supply, installation, testing and commissioning of Main telephone junction box MDF (with Tag block having jumpering facility) for connection of 50 telephone extension points / data server etc, at both ends hammer tone finished of appropriate size, conforming to PTCL specifications.
Part-C: UPS
Supplying fitting and fixing of LAN (Computer Cables)
CAT - 6 unarmoured UTP
SITC of Following Items,
Colour Indoor IR Dome HD Camera: IR 1080 P TVL Color Dome Camera 1/3 CMOS, 20M IR Distance, 3.6MM lens, DNR, IP66, 2 MP high performance CMOS
Colour Outdoor IR Bullet HD Camera:IR 1080P TVL Color Bullet Camera 1/3 CMOS, 20M IR Distance, 3.6MM lens, DNR, IP66, 2 MP high performance CMOS
24Ch. HD Standalone DVR: 32-ch video & 4-ch audio input, 4 SATA, 1080p Resolution,2USB, 12 VDC,HDMI & VGA Output, connectble HDTVI and HD
18.5" LCD Monitor LG/Dell/Samsung
SITC of Bullet camera as per site condition complete with all accessories
SITC of External light of 70 watt LED fixture with 7 meter GI pole of single arm, including foundation, foundation bolts, nuts, MCB, internal wiring with 3R x 2.5 sqmm, conduiting etc. complete as per site requirement
Aesthetically designed led post top with aluminium enclosure, powered with high power leds as light source and die casted heat sink exhibits classic victorian look with symmetrical light distribution and excellent heat dissipation for long life.
4 TB Surveillance Hard Disk (Video)( WD Purple)
BNC Connectors
Supply, Installation, Testing and Commissioning of following rated high performance IGBT based fully microprocessor controlled (Single phase Input & Single phase Ou
tput) online UPS system suitable for input and output parameters as per specifications. The UPS shall have Separate Galvanic Isolation Transformer Inbuilt/External K13 Copper Wound (After Static Switch) transformer. The UPS shall be provided in powder coated fan cooled enclosure painted in colour as per specifications. The UPS shall be suitable for normal, emergency, recharge, by-pass and maintenance mode including bypass arrangement. The UPS shall have a microprocessor based display and control panel. UPS shall have own batteries with 30 minute battery back-up with SMF batteries .Complete system must be provided as per specifications approved drawing and as per site requirement including inter connecting cables from battery to UPS, UPS to panel with single core copper cabling etc. UPS shall work on parallel/ hot redundancy mode, cost of supporting kit shall be included. supports for complete system as approved by the Engineer in charge complete in all respect.
Part D: Solar System
Part E: Ventilation System System
DC Connectors
PVC Mounting box for Dome Camera
350 mm dia/50 Pa
SANITARY FIXTURES AND FITTINGS
Receving, checking, storing and fixing in position European water closet comprising of :-
Wall hung European W.C. Pan in white colour, on approved type of chairs.
C.P jet spray / health faucet with required length of flexible tube, clamp and bracket for fixing to wall
15 mm C.P. brass heavy quality angle stop cocks for flushing cistern and jet spray / health faucet
Solid bakelite water closet cover and seat with C.P. hinges and rubber buffers.
Necessary pipe connection to CI / PVC soil pipe.
Painting bracket with two coats of white enamel paint over a coat of primer,
WC, seat & cover, brackets, flush valve / flushing cistern, jet spray / health faucet, angle stop cocks supplied by owners. All other materials and labour to complete the work by contractor. Including, providing and fixing P.V.C. WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia PVC pipe of required length and proper connection to C.I. / PVC pipe complete as required.
Receving, checking, storing and fixing oval / rectangular wash hand basin, counter top / counter sunk, with central tap hole on counter comprising of :-
Concealed type brackets fixed to wall with adjustable clamp to push against counter rim.
32 mm heavy plated C.P. waste coupling fitting with or without pop-up.
32 mm heavy plated C.P. bottle trap with cleaning eye with extension piece and wall flange.
Painting brackets with two coats of white enamel paint over one coat of primer.
CP pillar cock / basin mixer with 15 mm C.P. brass heavy grade flexible inlet connection with C.P. nut (minimum length 450 mm) made to measure .
15 mm C.P. brass heavy quality angle stop cock
Fixing, testing and commissioning of automatic flushing systems for urinal to ensure pre-flush & flushing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells, eyes electrically operated solenoid valve, step down transformer / equipment and any other item required to provide satisfactory functioning. Including necessary wall cutting / chasing and making good, as required.
15 mm CP sink cock / sink mixer table mounted / wall mounted
(S.S. Sink, sink cock / sink mixer, waste coupling fitting, bottle trap supplied by Owner. Rest including brackets by contractor.
Part D: Solar System
G.I. Heavy class pipe sleeves of specified diameter corresponding to the pipe size shall be provided wherever the pipes are crossing the fire rated walls/floors slab and sealing the sleeves with glasswool in between and fire sealant compound on either end, all as per E-I-C's requirement
(S.S. Sink, sink cock / sink mixer, waste coupling fitting, bottle trap supplied by Owner. Rest including brackets by contractor.
(S.S. Sink, sink cock / sink mixer, waste coupling fitting, bottle trap supplied by Owner. Rest including brackets by contractor.
Part D: Solar System
Part E: Ventilation System System
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
Cost shall be inclusive of (a)Making maximum of 7.5 x 7.5 cm chase in wall and floors for the pipe, making good the same by using 1:2 cement mortar over the wire mesh complete as required.
Part D: Solar System
Part E: Ventilation System System
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
15 mm (Internal Toilets )
Part D: Solar System
Part E: Ventilation System System
Part D: Solar System
Part D: Solar System
Part E: Ventilation System System
Providing, fixing, jointing and testing, heavy quality gun metal butterfly valve with rubber gasket, flanges / unions, nuts, bolts, washers, etc. complete, as approved by the Architect and Engineer-in-charge for water supply lines of the following nominal bore (NB) size:
Part D: Solar System
Part E: Ventilation System System
Part D: Solar System
Providing, fixing, jointing and testing, heavy quality gun metal full way gate valve including flanges / unions, nuts, bolts, washers, etc. complete, as approved by the Architect and Engineer-in-charge for water supply lines of the following nominal bore (NB) size:
Providing, fixing, jointing and testing, heavy quality gun metal or brass non return valve confirming to IS 778, with screwed / flanged ends, 20 kg/m2 of Simplex or equivalent make, on water supply lines of the following nominal bore (NB) size:
Providing, fixing and testing, heavy quality Pressure reducing valves of RB, Audco or equivalent make as approved,including flanges / unions, nuts, bolts, washers, Pressure guages, etc. complete by the Architect and Engineer-in-charge for water supply lines of the following nominal bore (NB) size: The upstream water pressure may be upto 25 kg/cm2g max. and downstream pressure min. 1 kg/cm2g.
Part D: Solar System
Providing, fixing , testing and commissioning threaded / double flanged water meter with direct reading dial in KL with all necessary fitting such as threaded pieces, unions pressure gauge, isolation cock, flanges piece for future removal, flanges / unions, NRV,Stainer,Butterfly valve complete with all necessary assesorries & testing charges
Part D: Solar System
Part E: Ventilation System System
Providing and fixing Brass Air release valve with Isolation (Ball) valve, double acting, of approved make, having 2 chambers with ebonite ball, small and large orifices with isolating stop screw down valve, GM seats, high tensile brass spindle with cap, conforming to standard water works pattern. Flanges as per IS : 15381, flat faced and drilled, complete of the following nominal bore (NB) size:
Providing and fixing C.I. “Y” strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanged / unions nuts, bolts and washers complete as required.
Part D: Solar System
50 mm dia.
Supply, Installation, Fixing, Testing and commissioning of 150 ltrs. Capacity Water cooler complete with suitable foundation, MS jali cage, 15Amps. Socket, required LED light in cage and 02Nos. Earth connections with cage 8 SWG GI wires.
Supply, Installation, Fixing, testing and commissining of Hand pump with suitable foundation and all other accessories and necessary equipments.
Supplying P.V.C. water storage tank of approved quality with closed top with lid ( Black ) Multilayer with all its accessories, valves and including the foundation.
200 mm thickness x 40 mm dia.
200 mm thickness x 25 mm dia.
INTERNAL DRAINAGE AND RAIN WATER
Supplying P.V.C. water storage tank of approved quality with closed top with lid ( Black ) Multilayer with all its accessories, valves and including the foundation.
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
Providing, fixing, jointing and testing heavy duty, PVC SWR pipes B-type, - 6 kg/cm2 pressure for soil and waste water drain including jointing with rubbering / solvent / solution and airtight joints, with necessary specials, couplers, elbow, equal tees, tail piece, adapter (both male and female), reducer (single stage, double stage and triple stage), end cap, fabricated bend, etc., and lubricant or jointing material, including testing, cutting, making good the wall, ceiling and floor etc. complete of the following nominal bore (NB) size: The rate shall include the cost of PP cowl for vertical downtake pipes., The pipes shall be having soundproofing charecterstices laid under floor / fixed on walls, and in pipe shafts etc. complete.
Part D: Solar System
Part D: Solar System
lvent joint. (This will cover Soil, waste pipe running from inside toilet area )
Part D: Solar System
Providing, fixing, jointing and testing PVC traps of self cleansing design with water seal not less than 50 mm.,jointing with rubbering / solvent / solution and airtight joints, with necessary specials, cutting chases / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing , etc. complete, as required. The trap shall be 'P' type, of following sizes: Temporary airtight PVC cover to be provided to prevent dirt entry.
110 mm dia outlet
160 mm dia outlet
15 mm CP sink cock / sink mixer table mounted / wall mounted
(S.S. Sink, sink cock / sink mixer, waste coupling fitting, bottle trap supplied by Owner. Rest including brackets by contractor.
Part D: Solar System
Providing and constructing R.C.C (mix 1:2:4) support pillars for G.I / C.I / PVC / PPR / CPVC, etc. pipes at ground level, service floor or over terrace complete with plastering as approved.
Part D: Solar System
110 dia. NB pipe.
Part D: Solar System
Part E: Ventilation System System
160 dia. NB pipe.
75 mm dia
50 mm dia
110 mm dia
Providing & fixing rain water `Khurras' required depth with lead flashing around the pipe with one piece lead sheet of 3 mm thick set on a layer of cold bitumen. Including Heavy duty CI/MS grating as per drawing complete as required.
EXTERNAL DRAINAGE AND RAIN WATER
Excavation by mechanical means for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, hard Murrum, soft & hard rock including removing the excavated material for all lift and lead with in the plot boundery,stacking, spreading as directed, including dewatering, fencing, lighting, watching, barricading, guarding, shoring, strutting, preparing the bed for foundation etc. complete as per specification,drawing and Instruction of engineering in charge.
From existing Ground level up to 500 m deep
Filling Work
Part D: Solar System
Providing , laying, jointing & testing NP2 class RCC pipes (IS 458) with mortise - tenon, jointed with cement and with RCC collar to cover and overlap the joints laid to correct levels below ground in trenches upto required depth including excavation in all kind of soil (including hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material, dumping it on site or carting away to lead of 100 meters as directed and making good the same complete as required. Price to include 150 mm thick PCC (1:4:8) haunches upto centre at the joints to cover the collar and 150 mm on bothsides and 400 mm wide cradles for intermediate supports at maximum 1 meter centre to centre in brick masonary (duly plastered 1:5 CM) on 100 mm thick PCC 1:4:8 over 230 mm rubble soling. The pipes shall be of following nominal bore (NB) size:
150 mm NP2 class RCC pipe.
Providing, fixing, jointing and testing salt glazed stoneware gully trap, class `A', of 100 mm. dia. inlet and 100 mm. outlet, including excavation in all soil types, bailing or pumping out water from trenches, shoring whenever necessary testing,refilling, in layers ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed, incl. embedding the trap in CC 1:2:4, construction of brick masonry chamber, internal clear size 300 mm. x 300 mm., in brick work 230 mm. thick, in CM 1:4, plastering inside, outside and all exp
osed surfaces with CM 1:3, 12 mm. thick, providing, fixing CI frame and cover 300 x 300 mm., weighing together not less than 12.5 Kg., painting of all CI items with 3 coats of approved bitumastic paint, etc. complete.
Part D: Solar System
Supply & fixing CI Manhole cover with frame ( LD )
Extra over and above item no. 4.04 beyond 1.5 m. depth, for every additional depth of 0.1 m. or part thereof, for brick masonry Inspection chamber.
Extra over and above item no. 4.06 beyond 1.5 m. depth, for every additional depth of 0.1 m. or part thereof, for brick masonry Inspection chamber.
0.6M x 0.60M and Upto 1.0M clear depth for sewer
0.9M x 0.60M and Upto 1.2M clear depth for sewer
Providing and fixing RCC manhole cover and frame of approved brand conforming IS 12592:2002 with lifting arrangement, including testing ,inspection of material sample and finished product at Manufacturer's work , etc. complete as specified and as directed by Engineer-in-Charge. (Inspection shall be as per guidelines of IS 12592) including fixing with M-30 concrete coping and locking arrangement ,as per specification etc. complete as specified and as directed by Engineer-in-Charge.
560mm internal dia and grade designation LD-2.5 as per IS-12592
Extra over and above item no. 4.10 beyond 1.5 m. depth, for every additional depth of 0.1 m. or part thereof, for brick masonry chamber.
Constructing conical manhole / inspection chamber for sewage, 1350mm dia at bottom & tapering upto 600mm dia at top in 450mm brick masonry in c.m. 1:5, with 230mm 1:3:6 plain cement concrete bedding, necessary benching in concrete (M-15) 20mm thick smooth cement plasters from inside (1:4) rough cement plaster from outside. Plaster (1:4) smooth finish inside & rough outside cast iron steps wherever necessarywith heavy type (175 kg) C.I. manhole cover & frame (Approved Make) incl. necessary excavation in all soil types, refilling sides in layers, ramming & consolidation, watering, curing removing away the surplus earth or dumping it on site as directed (Depth 1500mm to 3000mm to invert).
Extra over and above item no. 4.12 beyond 3.0 m. depth, for every additional depth of 0.1 m. or part thereof, for brick masonry manhole / Inspection chamber.
Providing and fixing, PVC heavy duty steps in manhole, water tank, septic tank, sumps, etc., of size 150 mm. x 100 mm. x 22.5 mm, including cutting, chasing the RCC / Brickwork and making good the same complete as required, etc.
Providing and fixing, PVC heavy duty rungs in RCC walls / brick walls of water tank, septic tank, sumps, etc., of size 150 mm. x 150 mm, including cutting, chasing the RCC / Brickwork and making good the same complete as required etc.
Charges for connection to main drainage from the local authority as per the local rules and regulations, including excavation in all kind of soil (including hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material dumping it on site or carting away to lead of 100 meters as directed and making good the same complete as required. Liasioning fees shall not be included in the rates. Piping paid as per respective items. (If in case of existing drain is available)
Sump Pit Pump
Water Supply Transfer pump
Supply, installation, testing & commissioning of Submersible single stage single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, electrical panel with in built level controller with operational mode as one pump working at low level, both pumps at high level with a hooter alarm and cut off at dry level as determined. The pump shall be provided with a lifting devise of pull chain including interconnecting piping with bypaas return line, Butterfly valves for all lines, 15 m cable etc. as per requirement complete in all respects. (Pumps shall be installed in a set of two pumps One working and One standby, with cascade operation).
(Pumps suitable to handle solids upto 8 to 10 mm size with C.I. body, SS 304 shaft, C.I. impeller with 15 mtrs cable, double mechanical seal).
Service : Water Supply Transfer pump
Each pump Flow rate : 2.7 LPS
Head :15 Mts
No of pump : (1w+1s)
Head :15 Mts
Rain Water Harvesting pit
Providing material and Constructing brick masonry circular type Rain water harvesting pit 3 m internal dia upto 5.0 m total depth (1.5 Effective depth), inside & outside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and finished with a floating coat of neat cement, 2 Nos. S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including Excavation, foot rests, centering, shuttering all complete all complete as per standard design : The rainwater harvesting pit sh
all be constructed according to the structure drawing.
Boring/drilling bore well of required dia for casing/ strainer pipe in All types of soil, by suitable method prescribed in IS: 2800 (part I), including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge.
300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC shallow well casing (CS) pipe of required dia including end cap, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (Make :- Supreme, Finolex, Ashirwad)
150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (Make :- Supreme, Finolex, Ashirwad)
Head :15 Mts
Supplying, fixing, jointing and testing of uPVC pipes conforming to IS 4985 class V (6 kg/cm2) including injection moulded fittings, all complete as per direction of Engineer -in-charge. (for vent) (Make :- Supreme, Finolex, Ashirwad)
110 mm nominal size dia
Supplying and wrapping 150 gsm geotextile cloth around the well screen pipe.
Part D: Solar System
Part E: Ventilation System System
Supplying, filling, spreading & leveling stone boulders of size range 50 mm to 200 mm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and lowering rounded & fully washed 3-6 mm pea gravel for packing of tube well construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & sizes as per actual requirement, all completed as per the direction of the Engineer-in-charge.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I).
Chemical Holding and Neutralization Tanks
Connections to RCC Water Tanks The Contractor shall provide all inlets, outlets, washouts, vents, ball cocks, overflows control valves and all such other piping connections including level indicator to water storage tanks as called for. All pipes crossing through RCC work shall have puddle flanges fabricated from MS/GI pipes of required size and length and welded to 6/8 mm thick MS plate. All puddle flanges must be fixed in true alignment and level to ensure further connection in proper order. Full way gate valves of a preferred make shall be provided as near the tank as practicable on every outlet pipe from the storage tank except the overflow pipe. Overflow and vent pipes shall terminate with mosquito proof grating. The overflow pipe shall be so placed to allow the discharge of water being readily seen. The overflow pipe shall be of size as indicated. A stop valve shall also be provided in the inlet water connection to the tank. The outlet pipes shall be fixed approximately 75mm above the bottom of the tank towards which the floor of the tank is sloping to enable the tank to be emptied for cleaning.
10000 Liters - Fire
Part D: Solar System
Part E: Ventilation System System
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
AUTOMATIC WATER SPRINKLER SYSTEM
200 mm dia
150 mm dia
Part D: Solar System
65 mm dia
50 mm dia
40 mm dia
32 mm dia
Supply, installation, testing & commissioning of conventional std coverage standard response quartzoid bulb type sprinkler with 15mm screwed end connection of K-factor of K80 & sprinkler bulb of size 5mm.
Pendent sprinkler of 68 deg.C
Upright sprinkler of 68 deg.C
Supply only of K80 Spare Sprinklers individually packed in polythene bags.
Supplying, installing, testing and commissioning of Quick response recessed sprinklers with Nickel chrome plated finish - K-80/ 68 deg.c (Pendent Type)
Supplying, installing, testing and commissioning of Ductile Iron OSY gate valve PN 16 rating. along with the supervisory switch, companion flanges, nut, bolt, washer and gaskets.
Supplying, installing, testing and commissioning of Water flow switch suitable for 150 mm dia with all its accessories shall be connected to fire alarm panel through cable. Cable shall be measured seperately in FAS BOQ
Supplying, installing, testing and commissioning of glycerine filled Pressure gauge (0-20bar) 150mm diameter with gauge cock and all its accessories
Test drain assemby generally complete as specified and as shown in the drawing. i) sight glass ii) ball valve 50 dia
Part D: Solar System
Part E: Ventilation System System
Supplying, installing, testing and commiss
Part D: Solar System
Part E: Ventilation System System
m dia. SCH-40, above 50mm dia. SCH-80 pipe considered)( This will cover water supply pipe running from Pump room to individual OHT + Pipe running at terrace level + vertical downtake piping in shaft )
Supplying, installing, testing and commissioning of 25mm dia GM air release valve with copper alloy globe valve.( Make: Leader)
FIRE HYDRANT SYSTEM
Supply, Installation, Testing & commissioning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the steel structural members. 10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bolts & washers & structural pipe support shall be one coat of zinc primer and two coats of fire red enamel paint Shed No.536 of IS 5: 1994 complete with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge. ( Pipe - JINDAL Make)
Supplying, erecting and commissioning of Landing Hydrants comprising of the following
Single headed hydrant valve as per IS 5290, made of gunmetal with 63 mm dia instantaneous outletof 80 mm dia fanged inelt ,Blank caps , chain and hand wheels etc complete.
2 lengths of 15 Mtr long, 63mm dia RRL hose as per IS:636 Type A with instataneuos couplings and Hoses shall be stored in side the hose cabinet.
Supply, Installation, Testing & commissioning of Mild Steel black pipes, ERW, Heavy grade conforming to IS:1239 up to 150 mm dia. and IS:3589 for pipes above 150 mm dia. complete with fittings, reducers, tees, high tech supports, structural clamps such as rods, channels, angles, nuts, bolts & washers, as required to be firmly mounted on the steel structural members. 10 % of all the welded joints shall be done rediographically tested and 50% of the joints radiographed shall be the "Field Joints" & hydrostatic testing for 2 hours at 150% of the system pressure, hook-up etc. Painting for piping, fittings, hanger support with U clamp, U bolt, threaded rods, nut, bolts & washers & structural pipe support shall be one coat of zinc primer and two coats of fire red enamel paint Shed No.536 of IS 5: 1994 complete with all accessories as per approved drawings, specification and direction of the Engineer-in-Charge. ( Pipe - JINDAL Make)
Single headed hydrant valve as per IS 5290, made of gunmetal with 63 mm dia instantaneous outletof 80 mm dia fanged inelt ,Blank caps , chain and hand wheels etc complete.
2 lengths of 15 Mtr long, 63mm dia RRL hose as per IS:636 Type A with instataneuos couplings and Hoses shall be stored in side the hose cabinet.
9U wallmountable Rack including all accessoriees i.e.fan,PDU,tray
Part D: Solar System
4 + 1 Co axial cable for camera through 25 MM PVC Casing N Caping and all required necessary accessories and hardware
Part D: Solar System
Erection of RCC/PCC Pole of Following Length in Brick Ballast & Ramming the Founation, Finishing with 150mm thick cement Concrete (1:3:6) Layer on top with Including Excavation & Refiling etc as required.
iii)Type: Single Head
I) Flow rate: 450 Ltrs/Min
Part D: Solar System
Part E: Ventilation System System
Above 6.5 Mtr & upto 8.0 Mtr
Supplying, installing and commissioning of Bourdon type Pressure gauge (150mm dial) with gauge cock - range 0-25 kg/sq.cm(g).
ABC Dry Powder type - 5Kg. Capacity as per IS:15683
CO2 type - 4.5 Kg. Capacity as per IS:15683
Sub-total of Fire Fighting System Cost : D
ENVIRONMENT MANAGEMENT PLAN (Fixes Cost)
Design and Preconstruction Phase
Regulatory Clearances/Permits like Tree Felling Permission and Compensatory Plantation
Regulatory Clearances/Permits like CTE/CTO, Authorization etc., Workman compensation insurance etc.
Lumpsum
Contractors Qualified Environment, Health and Safety Expert/s, PMC's and DSC's Qualified Environmental Experts,PIU and PMU level Qualified Environmental Expert
Baseline Monitoring: Ambient Air Quality
Number
Baseline Monitoring: Ambient Noise quality
Baseline Monitoring: Ground Water quality and Drinking Water
Baseline Monitoring: Surface Water quality
Baseline Monitoring: Soil Quality
Shifting of Utility (if applicable)
Construction Phase (1 Year)
Traffic management at worksite (signage, Warning Lights etc.)
Horticulture and Green Area Development
Waste and wastewater management
Monitoring: Ambient Air Quality
Monitoring: Ambient Noise quality
Number
Baseline Monitoring: Ambient Noise quality
Baseline Monitoring: Ground Water quality and Drinking Water
Monitoring: Ground Water quality and Drinking Water
Baseline Monitoring: Soil Quality
Monitoring: Surface Water quality
Monitoring: Soil Quality
Rainwater Harvesting structures
Noise Barrier near school and residential areas
Restoration of construction site
Water sprinkling during construction
Operation Phase (1year)
Regulatory Clearances/Permits like Fire NoC, etc.
Supplying & Laying of Following size DWC HDPE pipe ISI Marked along with all Accessories like Socket, bend,coupler etc. Conforming to IS 14930, part II Complete with Fitting & cutting, jointing etc.in the existing trench, complete as required.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.53 MB
BOQ_1972.xls
BOQ • 1.08 MB
Specifications.pdf
Additional Documents • 4.59 MB
SupplementaryInformationEHS.rar
Additional Documents • 32.53 MB
DrawingsCW06Lot01.rar
Additional Documents • 27.12 MB
Download all tender documents and submit your bid