| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC BUNGLOW NO 1 RAJPOOT VILLA BARARU ROAD PATKUYI BARARU SAGAR MP 470002 | SAGAR | SAGAR | MADHYA PRADESH | 470002 | L1 | Accepted-AOC aoc | |
| 2 | L2₹36.6 L+₹57,250 (1.59%)Rejected-Finance 5 21 SADAR BAZAR SAUGOR MP 470001 | SAUGOR | SAGAR | MP | 470001 | L2 | Rejected-Finance 2nd lowest bid | |
| 3 | L3₹36.7 L+₹62,232 (1.73%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest bid | |
| 4 | L4₹36.8 L+₹71,255 (1.98%)Rejected-Finance | L4 | Rejected-Finance 4th lowest bid | |
| 5 | L5₹37.0 L+₹95,125 (2.64%)Rejected-Finance H NO 114 A 10 GHAZI NAGAR RADDI CHOWKI GOHALPUR JABALPUR MP | L5 | Rejected-Finance 5th lowest bid |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
11 Jun 2022, 6:00 pmClosed
GE SAUGOR
GE SAUGOR
MISC REPAIR WORKS OF WATER PROOFING TREATMENT , ROOF SHEETS RELATED TO PREMONSOON MAINT WORKS AND CERTAIN B/R REPAIR, MAINT WORKS IN 108 TA INF BN, 372 SUPPLY AND OTHER UNITS UNDER GE SAUGOR
2022_MES_524310_1
GE/SGR/TOK-16 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
SAUGOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAUGOR
₹80,000
Yes
22 Jun 2022
18 May 2022
13 Jun 2022
18 May 2022
11 Jun 2022
2 Jun 2022
Amount
M&L for brickwork with subclass 'B' bricks, straright or curved on plan exc 6m mean radius built in cement mortar 1:6 including demolition of brick work with all qoins arches , pillars, etc built in cement mortar and removing rubbish from site complete all as specified and directed
M&L for stone walling of random rubble, uncoursed well bonded, bedded and solidly hearted built in cement -mortor 1 : 6 including demolition of rubbled stone masonry with all qoins arches , pillars, etc built in cement mortar and removing rubbish from site complete all as specified and directed
All as per Srl item No.2 but except stone. Note:-Serviceable stones obtained from demolition shall be re-used in this item.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and removing rubbish from site complete all as specified and directed .
M&L for rendering 20mm thick in cement mortar 1:6 on stone masonary fair faces / other than fair faces finished surfaces of brick wall finishing the surfaces even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 15mm thick in cement mortar 1:6 on brick wall / concrete surfaces of finishing the surfaces even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 15mm thick cement plaster on wall in cement mortar 1:4 on brick wall / concrete surfaces of finishing the surfaces even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling without using extra cement complete all as specified and directed . .
M&L for preparing the new plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
M&L for preparing the old decorated surfaces and applying two coats of white wash on walls complete all as specified and directed.
M&L for prepration of new wall surfaces & applying Birla / J. K. wall care white putty 2 mm thick for levelling the surfaces including properly making of 'V' shaped crakes and filling of all crakes with crakes seal of walls and applying two coat of interior emulsion distemper over a coat of wall primer incl. preparation of surfaces of walls complete all as specified and directed.
M&L for complete removal of existing treatment on wall and prepration of old surfaces & applying Birla / J. K. wall care white putty 2 mm thick for levelling the surfaces including properly making of 'V' shaped crakes and filling of all crakes with crakes seal of walls and applying two coat of interior emulsion distemper over a coat of wall primer incl. preparation of surfaces of walls complete all as specified and directed.
M&L for applying two coats exterior weather coat over one coat of exterior primer including preparation of surfaces of new walls etc complete all as specified and directed . Make:- Asian Ace or equivalent make as approved by GE
M&L for applying one coats exterior weather coat including preparation of surfaces of old walls etc complete all as specified and directed Make:- Asian Ace or equivalent make as approved by GE
M&L for applying three coats of white wash on new plastered ceiling surface including preparation of surface complete all as specified and directed..
M&L for applying two coats of white wash on old decorated Ceiling surface including preparation of surface. complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings not exc 15cm below or above ground floor and removing rubbish from site complete all as specified and directed .
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in plinth protection 75mm thick finishing cement concrete surfaces finished even & smooth without using extra cement joints to be filled with sealing compound grade 'A' complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in mass concrete as in foundation filling and mass concrete complete all as specified and directed.
M&L for cement - concrete 1: 2 :4, type B 1 (using 20 mm graded stone aggregates) as in surface channels and drain etc complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B1 (using 20 mm graded stone aggregates) as in sub base of floor to receive tiles or Kota stone complete all as specified and directed.
M&L for 50mm thick PCC 1:2:4, type B1 (using 20mm graded stone aggregates) as in floor, surface finished even and smooth without using extra cement complete all as specified and directed.
S&F Glass dividing strips, 3mm thick & inserted in position to confirm to design width of strip 38 mm complete all as specified and directed
Dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding and rubbish off the premises complete all as specified and directed.
M&L for coloured anti skid ceremic tiles 7 to 8 mm thick area of each tiles exc. 0.06 sqm and not exc. 0.11 sqm as in floor set & jointed in neat cement slurry and pointed in white cement mixed with pigment to match laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed coloured ceramic tiles of size 450mmx 300mm x 7 to 8mm thick , joint free (rectified) on vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed. .
M&L for coloured anti skid ceremic tiles 7 to 8 mm thick area of each tiles exc. 0.18 sqm and not exc. 0.36 sqm as in floor set & jointed in neat cement slurry and pointed in white cement mixed with pigment to match laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for coloured anti skid ceremic tiles 7 to 8 mm thick area of each tiles exc. 0.18 sqm and not exc. 0.36 sqm as in skirting, dado & jointed in neat cement slurry and pointed in white cement mixed with pigment to match laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for 600mm x 600mm x 8mm to10mm thick coloured vitrified tiles in floors set & jointed in neat cement slurry and pointed in white cement mixed with pigment to match the tiles laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for 600mm x 600mm x 8mm to 10mm thick coloured vitrified tiles in Skirting , dado & jointed in neat cement slurry and pointed in white cement mixed with pigment to match the tiles laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for coloured designer tiles exterior grade ( ENDURA or equivalent make as approved by GE ) 10mm thick laid over and including 15 mm thick cement mortor 1:6 set and jointed in floor and pointed in neat cement slurry with grey cement and pigment in floor complete all as specified and directed .
M&L for mirror polished machine cut Kota stone slab flooring 18mm to 20mm thick size not less than 550mmX550mm laid over and including 20mm thick screed in CM(1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
M&L for Kota stone slab 12mm to15 mm thick in skirting alid over and including 15mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
M&L for machine pressed precast cement concrete coloured chemically treated interlocking paver block any shape and size conforming to IS-15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment etc laid over and including 25 mm thick uniformly levelled surface of stone dust cushioning complete all as specified and directed..
M&L for 18mm to 20mm thick Granite of any shade ( table rubbed and polished ) in steps, jambs, pillars, windowcills, cooking plateforms and like laid over and including 15mm thick cement mortor 1:4 set jointed in neat cement slurry with fastners including pointing in white cement mixed with pigment to match shade of the slabs complete all as specified and directed.
M&L for rounding/ chamferring to edges of stone slabss one edge , such as in steps , cooking plateform and other similar situations complete all as specified and directed.
M&L for cement concrete 1:2:4, type B0 ( using 12.5 mm graded stone aggregates ) as in coping , apex stone , bed plate , kerbs including weathering , slightly rounded or chamferred angles and throating and incl. necessary form work complete all as specified and directed.
Cutting chases, pinning in, in brick wall for concealed water tubing and making good, in cement mortor 1:3 cutting not exceeding 10cm girth complete all as specified and directed.
S&F GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 15 mm dia GI tubing and connection complete all as specified and directed.
Taking down and refixing old 15mm GI tubing and connection in new or old position ( wall, floor, wall, etc ) complete all as specified and directed.
S&F GI tubing 20mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors including taking down 15 mm dia GI tubing and connection complete all as specified and directed.
Taking down and refixing old 20mm GI tubing and connection in new or old position ( wall, floor, wall, etc ) complete all as specified and directed.
S&F in repairs brass chromium plated 15 mm bore wall mixer for mixing Hot & Cold water with arrangement of head shower and with hand shower complete ,high pressure, screwed down for iron pipe complete all as specified and directed.
S&F in repairs 15mm bore brass chromium plated WHB mixer for mixing Hot & Cold water high pressure, screwed down for iron pipe complete all as specified and directed.
S&F in repairs 15mm bore C P bib taps, cast copper alloy fency type two way with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs chromium plated brass health jet foucet suitable for EWC including CP chord and brass nozzle and fixed to pipe complete all as specified and directed.
S&F in repairs PVC float valve assembly including assessories with float valve 20mm dia (Make -prayag or equvilent) complete all as specified and directed.
S&F in repairs soap dish brass chromium plated fixed to wall with brass chromium plated screw and wooden/ plastic plug complete all as specified and directed.
S&F in repairs 15mm bore C P bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs angular/ concealed stop valve , 15mm dia, cast copper alloy,CP with long shank and cup screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe complete all as specified and directed.
S&F in repairs Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S&F in repairs 15 mm bore bib tap standard of PTMT any colour high pressure screwed for iron pipe complete all as specified and directed.
S&F in repairs pillar taps, fancy type cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered “hot” or “cold” with long screwed shanks and fly nut screwed for iron pipe of 15mm bore, fixed in repairs complete all as specified & directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified & directed..
S&F in repairs PTMT PVC grating dome type of 100 mm dia. complete all as specified & directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified & directed.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste pipe including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified & directed.
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified & directed.
S&F in repairs vitreous China WHB white flat back size 550x400mm including S&F angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed.
S&F in repairs vitreous China squatting pan 'Orrisa pattern' size 580x440mm white with integral foot rests any pattern including provn of cement concrete bedding and making connection with & including 'P' or 'S' trap complete all as specified and directed.
S&F in repairs vitreous China wash down water closet pan (pedestal pattern), white including white seat cover complete all as specified & directed.
S&F in repairs vitreous China urinal bowl, flat back of size 465mmx355mmx265mm (minimum) white with grating and union for discharge pipe , waste pipe (excluding flushing cistern,flush pipe ) complete all as specified & directed.
S&F in repairs PVC low level flushing cistern of 10 Ltr capacity including flushing pipe, PVC bend, etc. , complete all as specified and directed.
S&F in repairs 75 mm size brass chromium plated shower rose with long body including fixing to steel pipe or union complete all as specified.
S&F in replacement 1000 ltr capacity of rotational moulded polyethyline water storage tank (Cylindrical vertical with closed type) three layered wall construction hoisted & fixed in position complete all as specified & directed.
S&F in replacement 500 ltr capacity of rotational moulded polyethyline water storage tank (Cylindrical vertical with closed type) three layered wall construction hoisted & fixed in position complete all as specified & directed.
S&F in repairs 110mm dia PVC(SWR) pipes single soketed in any length with adhesive joint fixed to wall including mild steel clamps complete all as specified & directed..
S&F in repairs 110mm dia PVC(SWR) pipes single soketed in any length with adhesive joint fixed to floor or trenches including fittings complete all as specified & directed.
S&F PVC (SWR) bends 110 mm dia complete all as specified and directed.
S&F in repairs for PVC (SWR) bends of bore 110mm with acess door complete all as specified and directed.
S&F in repairs PVC (SWR) 110 mm dia junction, single(single 'T') equal or unequal complete all as specified and directed .
S&F in repairs PVC (SWR) pipes 75mm bore single socketed, in any length with solvent joints laid in trenches or in floors with fittings complete all as specified & directed.
S&F PVC (SWR) bends 75 mm dia complete all as specified and directed.
S&F PVC (SWR) bends 75 mm dia with acess door complete all as specified and directed.
S & F in repairs for 75 mm dia PVC ( SWR) floor trap with grating including jointing with solvant complete all as specified & directed.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) not exc 1.5 sqm each complete all as specified & directed.
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.5 but not exc 4 Sqm each complete complete all as specified and directed .
Taking down shutters of any description not exc 1 sqm each complete all as specified and directed .
Taking down shutters of any description exc 1 sqm but not exc 2 sqm each complete all as specified and directed .
S&F second class hardwood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified & directed..
S&F 35mm thick second class hardwood factory made plain framed, penelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, size of rail and stile as per : IS 1003 (part I), kiln seasoned and chemically pressure treated. complete all as specified & directed.
S&F second class hardwood factory made glazed and skeleton shutters 35 mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc,sizes of members of shutters complete all as specified & directed.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood facepanels, commercial type on both sides, complete all as specified and directed (with double or single shutter).
S&F steel window with side hung shutter incl. box type hinges with steel handle, and steel peg stay ,25X3 mm ms flat 200 mm long hold fasts complete with glazing bar , dovetailed or welded complete all as specified & directed. .
S&F steel window with side hung shutter incl. box type hinges with steel handle and steel peg stay ,25X3 mm ms flat 200 mm long hold fasts complete without glazing bar , dovetailed or welded complete all as specified & directed.
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm thick wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with MS square tube complete all as specified & directed.
S&F factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face,incl 03 Nos of 100mm size stainless steel butt hinges for each shutter complete all as specified & directed.
S&F glazed (5.0 mm thick plain / coloured glass) aluminum door powder coated consisting of frame of 63mm x 38 mm size with shutter fixed on frame both side openable on pivotal arrangement with including necessary cutting holes in wall & floor Door shutter consists of top rail size is 83 x 44 mm , bottom rail & lock rail size is 110 x 44 mm & style of door shutter is 83mmx 44 mm with handles 2 Nos in each door , hinges has fitted on frame as required fixed with rubber gasket & aluminum beading any No of panels with aluminum handle , locking arrangemen,floor spring and floor door stopper incl. necessary joining cleats , glazing clips etc complete (Al. section thickness 2 mm } ) confirming to IS complete all as specified & directed.
S&F aluminium windows and ventilators sliding type three track powder coated consisting of frame 91.80 mm x 45 mm shutters 39 mm x 18 mm with rollers and locking arrangements with 4 mm thick plain glass with rubber gasket and aluminium beading , Al. handle,aluminium grill with fixing arrangement (wt. of grill not less then 2.50 kg/sqm),aluminium wire mess 0.45 mm dia etc including necessary cutting holes on wall and floor and confirming to IS complete all as directed by Engr-in- Charge (Al. section thickness 1.50 mm }
M&L for repairs of existing aluminium door with taking down and refixing in same location including all necessary fitment for repairs all as specified and as directed by Engineer-in-charge.
S&F in repairs floor spring for aluminium door ISI marked complete all as specified and directed.
Hacking out old broken glass (any tickness, size,quality or description) from wooden / steel framesglazed with oil putty or fixed with beads complete all as specified and directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed.
S&F 3 mm thick figured glass, pin head type and glazing with oil putty in squares not exc 0.5 sqm in each pane complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) as in filling of hold fast etc, complete all as specified and directed.
M&L for preparing surface of wood & wood based materials, steel & iron work, new or old, of any description & girth, not otherwise described, & treated with tar or coal tar black paint complete all as specified and directed..
All as per Srl item No. 97 as above but treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area not exc 0.1 sqm each complete all as specified and directed..
S&F mild steel hold fasts, plain angle cleats for securing purlins and similar small articles confirming to Fe 290 Gde E 165 complete all as specified and directed.
S&F framed work such as grills gratings, sunshed cover fixed with nut bolts incl,cutting drilling holes etc., with ends of bars shouldered and or riveted, similar work confirming to Fe 290 Gde E 165 complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.46 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repairs galvanised mild steel wire cloth, 0.46 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete including necessary wooden beading complete all as specified and directed
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F butt hinges of 100 mm size, Medium weight, cold rolled mild steel complete all as specified and directed.
S & F door stopper of aluminium alloy body and tongue 150 mm long , anodised fixed in door with screws complete all as specified and directed
S&F in repairs 150mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
S&F 200 mm size aluminium anodised, barrel tower bolts, of extruded section complete all as specified and directed
S&F 125mm long, Aluminium, anodised, barrel tower bolts of extruded section. complete all as specified and directed
S&F 150 mm aluminium anodised cast type handles and fixed complete all as specified and directed
S&F Aluminium alloy, anodised, sliding door bolt 250 mm long dia not less then 12 mm with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed
M&L for suspended false ceilling comprising of 4mm thick non asbestos fibre cement bulding boards of size 595mmx595mm, fixed or laid/inserted to powder coated GI frame work with screws over GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to sourrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fastners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm center to centre including hangers 4mmm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long incl dismantling of any type or ceiling boards in thickness incl cover fillets complete all as specified and directed. Make : Everest (Lake and Hill) or equivalent including dismantling of any type of ceiling boards in any thickness incl cover fillets etc.
Dismantling unframed timber scantlings 40 sq. cm & over in section, in any position complete all as specified and directed.
M&L for second class hardwood in scantlings , timber clean sawn framed and fixed complete all as specified and directed .
S&F rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins of squar pipe, tubular or angle where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe410-0 or Fe 310-0 complete all as specified and directed
S&F 6mm thick asbestos cement, corrugated or semi-corrugated shets in roofs fixed with L-type or J-type or cranked hook bolts including dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed
Taking down and re-fixing asbestos cement, corrugated or semi-corrugated shets in roofs complete all as specified and directed.
S&F 6mm thick asbestos cement serrated ridge or hip ridge for corugated or semi corugated sheets, fixed with L-type or J-type or cranked hook bolts including dismantling existing damaged AC sheet ridge/hip for corrugated or semi corrugated sheets from roof complete all as specified and directed
S&F 0.50 mm thick galvalume sheet profile pattern precoated coloured having tensile strength 550 Mpa as in roof covering, fixed with self driving screws including taking down old GI sheeting complete all as specified and directed
S&F 0.50 mm thick galvalume sheet precoated coloured profile ridge, fixed with self driving screws including taking down old GI ridge complete all as specified and directed
S&F mild steel for wind ties for roof including securing bolts, posts including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed..
S&F in repairs 25 mm bore SS Pipe curtain rods including stainless steel brackets & stainless steelecorative dome, suitable for door/widows curtain with fancy type powder coated SS dooms with ss brackets fitted to each end and making good the disturbed surfaces complete all as specified and directed
Dismantling timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section framed/unframed complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails , post, and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc including bending and welding angles, as necessary, gusset plates, riveting, bolting etc complete all as specified and directed
S&F MS plates (plain or chequered) channels square cut to or notched forming holes with riveted bolted or welded attachment for Fe-410W complete all as specified and directed.
Disconnecting existing tanks exc 250 but not exc 500 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning removing all scale and dirt etc from tanks and mouth of circulating pipes, etc. and hositing, reconnecting and re-fixing in position complete all as specified and directed.
S&F in repairs 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe (Minimum weight 210 gms) complete all as specified and directed
Uprooting completely tree/ plants (upto 30 cm girth) from wall or any part of building upto double story buildings, making good disturbed portion and filling holes in cement mortar (1:3)/PCC (1:2:4) to match with the existing surfaces complete all as specified and directed.
M&L for PCC (1:2:4), type B-1 (using 20 mm graded stone aggregates) on roof top as a leveling course / padding to maintain the slope,and roof kerbs,or mud stops, rounded or chambered on edges etc finished the surface even and fair complete all as specified and directed .
M&L for water proofing roof treatment to RCC roof with approved modified membrane of weighing not less than 3 kg/Sqm . The height of the roof may upto 9 m comprising with following items including taking down of old roof treatment of any description including mud phushka, lime, concrete,tiles , cement plaster, padding upto 30cm depth from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250m and not exc 500m from the roof of height 3m to 9m height complete all as specified and directed:-
(a) The surface of roof, parapet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting. (b) Applying 10mm thick plaster in CM 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab complete all as specified (Note : WPC shall be measured and paid separately) (c) Oil based Bitumen primer conforming to IS-3384-1986 @ 0.3 kg per sqm to be applied on prepared surface till the surface is properly impregnated. (d) Applying one coat of hot blown bitumen of 85/25 grade @ 1.20 kg/Sqm. (e) Laying of water proofing APP modified polymeric water proofing membrane of weight not less than 3 Kg / sqm composed of 100 micron (+10% ) high density polyethylene sheet (HMHDPE) as center core, which is sandwitched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps100 mm as per manufacture instruction (f) Applying one coat of hot blown bitumen of 85/25 grade @ 1.20 kg/Sqm. (g) Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces, complete all as specified and directed
M&L for water proofing roof treatment to RCC roof with approved modified membrane of weighing not less than 3 kg/Sqm . The height of the roof may upto 9 m comprising with following items including taking down of old roof treatment of any description including mud phushka, lime, concrete,tiles , cement plaster, padding upto 30cm depth from roof surfaces etc including cleaning, brushing and watering to joints and grooves and throwing the same to a distance exc 250m and not exc 500m from the roof of height 3m to 9m height complete all as specified and directed:-
(a) The surface of roof, parapet and gutters drain mouths etc over which water proofing treatment is to be applied shall be cleaned of all foreign matter such as fungus,mass dust etc by wire brushing and dusting. (b) Applying 10mm thick plaster in CM 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab complete all as specified (Note : WPC shall be measured and paid separately) (c) Oil based Bitumen primer conforming to IS-3384-1986 @ 0.3 kg per sqm to be applied on prepared surface till the surface is properly impregnated. (d) Applying one coat of hot blown bitumen of 85/25 grade @ 1.20 kg/Sqm. (e) Laying of water proofing APP modified polymeric water proofing membrane of weight not less than 3 Kg / sqm composed of 100 micron (+10% ) high density polyethylene sheet (HMHDPE) as center core, which is sandwitched between high quality polymeric bitumen mix having softening , high heat resistance and cold flexible protected on either side with a thin thermo fusible HMHDPE film with side and laps100 mm as per manufacture instruction (f) Applying one coat of hot blown bitumen of 85/25 grade @ 1.20 kg/Sqm. (g) M&L for cement concrete tiles 25cm x 25cmx 22 mm thick, machine pressed, set jointed and pointed with neat cement slurry on roof and cut and polished over and including 15 mm thick screed bedding in cement mortar (1:4) complete all as specified and directed
Supply only integral water proofing compound, completeall as specified and directed.
M&L for applying two coats of elastomeric-acrylic waterproof protective cum decorative coating on external surface of RCC, concrete panels, plastered surface of wall etc. over a coat of primer including preparation of surfaces all as per manufactures instructions complete all as specified and directed.. Make: Dr Fixit (Raincoat) or equivalent make as approved by GE
M&L for applying evenly a coat of blown type bitumen 85/25 at the rate of 1.50 kg per square metre over a coat of bitumen primer @ 0.30 to 0.50 kg per Sqm and blinding with clean dry sand @ 0.05 Cum. per sqm over roof surfaces including preparation of old surface complete all as specified and directed.
M&L for point wiring for the following with 1.5 Sqmm PVC insulated FR, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC Casing -n-caping /conduit of size not less than 20mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green including taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor complete all as specified and directed :- .
For one light point or fan point controlled by one switch
For one Call Bell point controlled by one push button switch
For 5Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
All as per Srl item No.135 here in before but for power point wiring using with 2.5 sqmm PVC FR insulated, unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated, unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth wire -ditto-
M&L for concealed point wiring for the following with 1.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate of suitable module with frame as per site requirement all fittings such as tees, bends, elbows, etc. all as per site requirements, PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green including taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor complete all as specified and directed :-
For one light point or fan point controlled by one switch
For one Call Bell point controlled by one push button switch
For 5Amp independent socket point controlled by one switch
For one 3 pin ,5 Amp socket point with other switch on the same board
All as per Srl item No.137 here in before but for power point wiring using with 2.5 sqmm PVC FR insulated ,unsheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,unsheathed, copper conductor stranded 1100 volt grade cable as continuous earth wire
S&F modular switch, one way,6 Amp 230, 1 module complete all as specified and directed .
S&F modular socket 6 Amp-2/3 pin combined 2 module complete all as specified and directed
S&F modular switch, one way,6 A/16 Amp 230, 1 module complete all as specified and directed
S&F modular socket 6 A/16-2/3 pin combined 2 module complete all as specified and directed.
S&F modular fan step regulator 120 Watt -2 module complete all as specified and directed
S&F modular bell push 6A one module complete all as specified and directed.
S&F switch piano type flush, single pole, one way 5 A, 230 V complete all as specified and directed.
S&F socket outlet, 5 pin, 5 Amp, flush type, 230 V complete all as specified and directed.
S&F switch piano type flush, single pole, one way 15 A, 230 V complete all as specified and directed .
S&F socket outlet 2 in 1,6 pin, 5/15 A, flush piano type 240 V.complete all as specified and directed
S&F ceiling rose, surface backlite, three terminal complete all as specified and directed .
S&F lamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed.
S&F in repair/replacement bell ding dong 230 V, single phase complete all as specified and directed.
S&F electronic double space rotary 5 speed type regulator 120-280 V complete all as specified and directed.
S&F bell push flush type one way 5Amp 240 Volt complete all as specified and directed
M&L for concealed sub main wiring with two single core PVC FR insulated unsheathed stranded copper conductor cable FR, 02 runs of 01 Single core of size 6 sqmm (for main current) drawn in & incl PVC conduit less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified including taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
M&L for sub main wiring with two single core PVC FR insulated unsheathed stranded copper conductor cable FR, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC Casing-n-caping of suitable size ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed
S&F in replacement testing and commissioning of MCB SP 240 volt 6 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in replacement testing and commissioning of MCB SPN 240 volt 16 Amp to 40 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed
S&F in replacement sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar complete all as specified and directed. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces shall be included in item quoted rate .
S&F in replacement double door metallic sheet metal enclosure for DB double door(IP-42/43) When MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete all as specified and directed. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces shall be included in the quoted rate .
S&F in replacement metallic sheet metal enclosure for DB Single door(IP-42/43) When MCBs to be used SPN 2 ways, 240 V with 200Amps rated bus bar complete all as specified and directed. Note :- Cutting and chasing in stone masonary and making good to disturbed surfaces shall be included in the quoted rate .
S&F in replacement LED Bulk head 13/10 watt designed for modern homes availave in PIR as well as non PIR sensor with premium quality diffuser for glarefree light and easy to install snapfit installer complete all as specified and directed
S&F in replacement TL fitting 20 watt for surface and wall mounted LED batten with ultra slim polycarbonate LED lighting fixture with high lumen output environmental friendly energy efficient complete all as specified and directed
S&F in replacement box type LED optic fitting 10/9 Watt 2 feet box type complete all as specified and directed
S&F in repair/replacement socket outlet multi purpose, 3 pin, 15 Amp & 3 pin 5 Amp combination complete all as specified and directed
S&F modular AC box enclosure with socket plug top and MCB SP 25 Amps flush mounting enclosure . complete all as specified and directed
S&F in replacement PVC insulated and unsheathed single core multi stranded copper conductor 1.5 Sqmm (Nominal Area) drawn in existing conduit / batten / surface complete all as specified and directed
All as per Ser item No 166.00 above but size 2.5 Sqmm
S&F in replacementy laminated super hylem sheet of size 8" x 5" white colour 3mm thick of sizes including fixing of switches, sockets as per existing pattern complete all as specified and directed
All as per Ser item No. 168.00 above but of size 5"x5"
All as per Ser item No. 168.00 above but of size 8"x10".
All as per Ser item No. 168.00 above but of size 8"x12".
All as per Ser item No. 168.00 above but of size 9"x11".
S&F in replacement PVC conduit of size 20mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site complete all as specified and directed
S&F in replacement PVC conduit of size 25/32 mm dia including fixing on wall/ceiling with suitable clamp/saddles for wiring wire all as required at site complete all as specified and directed.
S&F in replacement PVC casing caping of size 1" x 1/2" including fixing on wall/ceiling with clamp/saddles for wiring wire all as required at site complete all as specified and directed
pal enterprises
maharaja construction and suppliers
v k builder
HAFEEZ CONSTRUCTION
Pandey Construction and Engrs
anil kumar sahu
M K Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .